HomeMy WebLinkAboutBuilding Permit Application (2) i
A �
,gin.eering Consultants, Inc. Tel: 772-708 7785&772 828 2263
- 2237 Woods Edge Circle Orlando FL 32817
'I
STRUCTURAL INSPECTION CERTIFICATION
(WITH STRUCTURAL CEIMFICATION)
March 11, 2016
I
Project: Re-Roof Installation for Susan Troster Residence at:
90 Aqua Ra Dr, Jensen Beach FL
Permit for a new 5v Metal Re- Roof Cover
.i
Prepared for: St. Lucie County Building Department
I
Client: Onshore Roofing Specialist Inc. 4401 SE Commerce Ave. Stuart Fl.
Background.
On March 10, 2016, B & B Engineering, Inc. was requested by Onshore Roofing Specialist Inc. a Florida
License Roofing Contractor to visit the above site to visually inspect the structure as to its ability to support the
proposed new 5V Metal Roof Cover installation for the above residence.
_Certification:
& B Engineering, Inc. certifies that the existing roof support structure is in good shape and capable of support
-die new roof cover. It also meets the required wind loading as per ASCE 7-10, Exposure C with 165 mph. The
existing plywood deck will be re-nailed to the existing roof structure support using galvanized steel 8d ring
shank nails at 4"on center edge and 6"center field. The new underlayment, one layer of ASTM 30#base sheet,
will be mechanical attached with galvanize plastic cap as per manufacturer's "recommendations, and the 5V
26Ga. Metal Roof System FL Approval No.17022-1 also as per manufacturer"s recommendations, and 2014
FBC. The low slope portion of the roof structure will be cover with Polyglass SBS and APP Modified Bitument
as per evaluation report P9290.02.08-R141711654-R16. 11
To the best of our knowledge and professional ability, it is B & B Engineering Inc. opinion's that the work will
be properly done and the new roof cover will be structural sound, safe and in compliance with Codes and
Manufactures specifications.
Limitations.
Our professional services have been performed, our finding obtained and our opinions prepared in accordance
with general accepted structural engineering principles and practices. This Company is not responsible for the
conclusions, opinions or recommendations made by others based on our findings. The certification submitted in
this report is based upon the field inspection on March 10, 2016 and was intended to evaluate the existing roof
structure to assure the integrity of the proposed new roof cover.
Approved,
Oscar M. Berm E
FL Licens 1
.I