Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 RECEIVED APR 18 2036 L =r.1?:Y�°at 14.:67 SCIS Home 'Log In User Registration Hot Topics Submit Surcharge - Stats&Facts Publications FBC Staff i BCIS Site Map Links - Search Business '�productApproval Professioriai J USER:Public User Product Aooroval Menu>product or Aooliwtlon Search>Application List>Application Detail FL# FL10674-R10 �,......_._._:. _. Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Coming Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Rooting Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich,PE �! Validation Checklist-Hardcopy Received Certificate of Independence FI 10674 R10 COI 2015 O1 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections tram the cOcie http://w-ww.floridabuil dinc,.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 9/15/2015 Florida Building Code Online Pa1_7 ? of 2 Product Approval Method Method 1 Option D Date Submitted 04/22/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-Cab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R10 II 2015 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES &10674-R10.pdf Impact Resistant:N/A Verified By: Robert].M. Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other: Refer to ER,Section 5. Evaluation Reports FL10674 R10 AE 2015 04 FINAL ER OC ASPHALT SHINGLES FL10674-R10_pdf Created by Independent Third Party:Yes Bock F. Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.if you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395.`Pursuant to Section 4SS.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: http://www.floridabuildin�.org/pr/pr_apptD _dtl.aspx?param=wGEVXQwgtBNbEY5V%2... 9/15/2015 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 353 CHRISTIAN STREET,UNIT#13 ERD OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-RS One Owens Corning Parkway FL10674-R10 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 5: 04/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: :rte -'• ' Robert J.M.Nieminen P.E. �ry�v+�•:..:.•y .;: The facsimile sea[ This does not serve authorized by Robert Nieminen, , .,h,`�irJt_�t-�t 4 P.E.an 04/22/2015.This does not serve as an electronically signed '�+�,huigrrriN Florida Registration No.59165,Florida DCA ANE1983 document.Signed,sealed hardmpies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity[ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ui �!'� ED ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Eaiipl Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireT1 are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration', TruDefinition' Duration', Duration' Premium Cool, TruDefinitioe Duration® Designer Color Collection, TruDefinitioe Oakridge',Oakridge and WeatherGuard HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeT" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roofshingles. ' 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to Vasa=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(V„1t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization 119503 FU0674-R10 Revision 5:04/22/2015 Page 2 of 6 INI 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: > Berkshire shingles require minimum five(5)nails per shingle. > WeatherGuard HP shingles require minimum six(6)nails per shingle. > Devonshire"'shingles require minimum six(6)nails per shingle. > Starter Strip Plus requires minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Classic°&Supreme: F5" 7'A"reasHigh ansard or Area para Normal Mansard or Area para Wind desvanos y Wind Areas High Wind desvanes y reas vientos fuerresArea para vientos normales Areas vientos fuertes T. z•l (B) posure 55(8"Exposure posieion Exposieion 6.2.6 Minimum Nailing—Berkshire®: Sealant strip Sealant strip La Lira de sellador La tira de Wlador t--►a 't--iC a e —y c<--s o eF >o a=te o • ----------->0$ )o Tr- R Y" 4 V:r' 9 Y41 R Vi" t 8 r/:' 8'?" R y:" 8?'_•• e e t - 2.. Asphalt roolingcement Cemenio de lecho de astaho Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R5 Certificate of Authorization#9503 FU0674-R10 Revision S.04/22/2015 Page 3 of 6 � ����� ���r�� � � ��, 6.2J Minimum Nailing—Devonshire'": als Nails Ten 1"Spots of Asphalt Roof Cement 6.2.8 Minimum mai|inm—ouratmno'nmoefinmon°Duration,ou,ation° Premium cou| orrmDefinmon~Duration~Designer Color Collection: Esquerria SuteMail"t3stening area width 12. Ara3da Nails 6.2.9 Minimum Nailing—Tmopfinuion~oakndue° Oakridge": 4 Nail Pattern 6 Nail Pattern 5 518"Experute Flails 5 519"Exposure Nails Fxposici'6n de 55IGputy. clavos Exposid6a da 66,618 pufg. 5 518"Exposure Claws 5 5JS"Exposu 8.I.I0 Minimum Nailing—VveatherGuandmHP: I Singl side view F:;:- Exterior Research and Design,LLC. Evaluation Report osryoo.0o.12-mS oerty1cate ofAuthorizatio"#9503 ru0674-RIO Revision s:no/az/zo1s Page 4oro f ' TRINITY ; 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard�HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4)nails per shingle. Installation of DuraRidge'"Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 �— PiinpWnd . 44 Q;? ., Fig.2 Oir.dlon TopVst SWeVw A flails Hals g4 I tl \t ¢1>�z TopLmulalal im. I vl w r o- `I �losme u1 J 1 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: ttem Fag. 2 -High W hd Fastening Pattern (4 Nails) Man Shin gle—+� s-d 21P Exc; �IP �tt Sealant D Strip v G 12" ' Fastening S'1," 5"Exposure DiiinC-- 1 2 �r 6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge: e 6 — Fig.C Hip&Ridge Shingle Fastening Fig.A Top Mel Prevalling Vllnd l''',• I I Halls Halls A''* A' �•, I I ,' I , ,' 1 1 � o-]-c + d tl I" Eryosure 11 g• Exposure a �. DIY ,2 DI Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate ojAuthorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 5 of 6 .���� i��"�^ 6.3.6 Minimum Nailing'pmcdmeHip Ridge Shingles: Prevailing Standard Wind Direction Fastening Sealant Strip Pattern 6'Exposure 1111-1 12, Sealant Vi Fasten 7112" Exposure Cover Exposed Fasteners with Roof Cement 6.3.7 Minimum Nailing—ouramdme"'Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. ProvailsigWim!Diroction Top Vi,'. 7A C UZ Irv,ATEA I 7. Lxocums: 7.1 Labeling shall beinaccordance with the requirements the Accredited owa|hvxssuranceAmenn/notedhenun. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in pacTab\e 1507.2.7.1/n905'2.6.1. Q' BUILDING PERMIT REQUIREMENTS: x,required bvthe Building Official orAuthority Having Jurisdiction inorder toproperly evaluate the installation ofthis product. g' MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule ym'aCIA requirements. 10' QUALITY ASSURANCE Emrnr: UL LLC—QUx3525;(414)248'5409; - END opEVALUATION REPORT' Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R5 `Certificate wAuthorization x95m pc10674-mm Revision s.uw2z/20zs Page 6o,s