IKO Industries, Ltd
40 Hansen Road South
Brampton, NON -US L6W 3H4
(708)496-2800 Ext 200
rmetzOO1@tampabay.rr.com
Robert Metz
rmetzOO1@tampabay.rr.com
Bob Metz
REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727) 776-5261
rmetzOO1@tampabay.rr.com
Don Shaw
IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717) 579-6706
don.shaw@iko.com
Roofing
Underlayments
Test Report
PRI Construction Materials Technologies, LLC
Keystone Certifications, Inc.
06/26/2025
Zachary R. Priest, P.E.
VValidation Checklist - Hardcopy Received
1 of 2 3/1/2016 1:26 PM
BCIS Home Log In User Registration Hot Topics
Submit Surcharge Stats & Facts
Publications ; FBC Staff ; BCIS Site Ma
Business1
_
Professional
ttProduct
�*r USER: Public User
equiaton,
`
Product Approval Menu > Product or Aoolication Search > Aoolication
List > Application Detail
FL #
FL15529-R1
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Testing Lab
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
IKO Industries, Ltd
40 Hansen Road South
Brampton, NON -US L6W 3H4
(708)496-2800 Ext 200
rmetzOO1@tampabay.rr.com
Robert Metz
rmetzOO1@tampabay.rr.com
Bob Metz
REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727) 776-5261
rmetzOO1@tampabay.rr.com
Don Shaw
IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717) 579-6706
don.shaw@iko.com
Roofing
Underlayments
Test Report
PRI Construction Materials Technologies, LLC
Keystone Certifications, Inc.
06/26/2025
Zachary R. Priest, P.E.
VValidation Checklist - Hardcopy Received
1 of 2 3/1/2016 1:26 PM
Florida Building Code Online
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
http://www.floridabuildinc,.org/pr/pr app_ dtl.aspx?param=wGEVX...
FL15529 R1 COI FL12838 R2 COI PRI CMT Cert of Ind
FL15529 R1 COI FM - Certificate of Independence 3-25-2C
Standard
D1970
Method 1 Option B
06/29/2015
07/14/2015
07/23/2015
10/16/2015
FL # I Model, Number or Name I Description
15529.1 StormShield Standard Ice andI #7910033
Water Protector
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
Year
2009
Installation Instructions
FL15529 R1 II SShieldIW0806 Application
2012.pdf
Verified By: PRI Construction Materials Tech
Test Reports
FL15529 R1 TR IKO-081-02-01 Report AS
StormShield Standard Ice and Water Protect
PRI.pd
FL15529 R1 TR IKO-143-02-01 FBC 2014
FL15529.pdf
Back Next
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: $i
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records req
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wi
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. Ii
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if yo
Chapter 455, F.S., please click herr.
Product Approva I Accepts.
® Ek
secu ritv.,-, .;.
2 of 3/1/2016 1:26 PM
CONSTRUCTION MATERIALS
TECHNOLOGIES
Brad Grzybowski
Managing Director
July 9, 2015
Dear Sir/Madam,
PRI -CMT tested several products for IKO Industries and subsequently issued Laboratory Test Reports. These
reports have been utilized to support FL15529. This letter serves to establish compliance of legacy test reports
to FBC 2014.
FL15529 — StormShield Standard Ice and Water Protector
Product Specification
• Applicable product specification: ASTM D1970
• FBC 2014 referenced standard year: ASTM D1970-09
• Test Report: PRI Project/Report Number IKO-081-02-01 states compliance to ASTM D1970-08.
• Action: Establish equivalency between ASTM D1970-08 and ASTM D1970-09.
• Conclusion: Compliance to FBC 2014 established.
Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not
have nor plan to acquire a financial interest in any company manufacturing or distributing products for which
the test reports are issued.
Signed: Signed:
Brad Grzybo*ki Duc T N uyen
Managing Director Florida Regist6fed Professional Engineer
P.E. Number: 65034
Date: July 9, 2015 Date: July 9, 2015
I KO -143-02-01
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materiaistesting@pricmt.com WebSite: hfp://www.pricmt.com
APPLYING IKO'S STORMSHIELD
ICE & WATER PROTECTOR
Caution
• Read all instructions before proceeding with application.
• Membrane must always be covered by shingles or other roofing materials. It must not be left exposed
to the weather.
• This product is a vapour retardant. Space under roof deck must be properly ventilated to avoid
moisture condensation.
• In cool temperatures membrane should be tacked in place with mechanical fastenings.
• Installation is not recommended when air and substrate surface temperatures are less than 5°C (40°F)
APPLICATION DIRECTIONS
Surface Preparation
• The roof deck must be clean, smooth, dry and free of sharp protrusions.
• Metal and masonry surfaces must be primed.
Installation
1. Cut the membrane into 3 m to 4.5 m (10 ft. to 15 ft.) lengths.
2. Unroll and align with the lower edge of roof. Tack top edge with four equally -spaced temporary
fasteners.
3. Lift the lower half and remove the lower release film, exposing the adhesive surface.
4. Carefully reposition the membrane down onto the deck and press firmly in place. Avoid wrinkles.
Remove temporary fasteners.
5. Fold top half down and remove release film.
6. Carefully reposition the membrane up onto the deck and press firmly in place. Avoid wrinkles.
• If two courses are required, the top course should overlap the selvage tape on the lower course by
75 mm (3").
• End laps must be at least 15 cm (6") and rolled to ensure adhesion and should be located at least 61
cm (24°) from those in the previous course.
• Apply each course carefully.
• Best suited for low sloped roof areas. Cover entire area with StormShield Standard Ice and Water
Protector, lapped as outlined above, and then shingle as per normal shingle exposures.
Valleys and Ridges
• Cut the membrane into 1.2 m to 1.8 m (4 ft. to 6 ft.) lengths. In the valley, start at the low point and
work upwards, overlapping each sheet at least 15 cm (6"). Peel off the release film and centre the
sheet over the valley or ridge. Drape and press in place working from the centre outward toward the
edges.
• Membranes must not be left exposed in an open valley.
Ice Dam Protection
• Membrane must be applied to reach above the highest expected level of ice dams, and at least 61 cm
(24") up the roof from the vertical projection of the interior surface of the outside wall.
Drip Edge
• Drip edges must be located under the membrane at the eaves, and over the membrane at rake edges.
Note
Do not remove selvage tape.
Storage
• Store rolls in their carton until application. Store inside or under cover not over 40°C (104°F)
SShield]W 08-06
4.
SShieldlW 08-06