Loading...
HomeMy WebLinkAboutProduct Approval gppt - . Sales Contact: 5307 Inlet Way _Job.# Fort Pierce, FL 34949 Field Inspector: Miami/Dade Pitch Diagram (in/ft) In this diagram pitch values are shown in inches per foot, and arrows indicate direction. 3 t—3 j W I E Note:This diagram contains labeled pitches for facet areas larger than 20 square feet. In some cases, pitch labels have been removed for readability. Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates pitches of 2/12 or less. If present, "I"' indicates a flat facet (no pitch). ar�aJ'3'�Ltv�GYM Y y a (1€P3a!t IT3£fSrYC71 c ( } T.ECH.NQLOGIES Appt; . Sales Contact: 5307 Inlet;Way�:; Job#. Fort Pierce, FL 34949 Miami/Dade Field Inspector: Area Diagram Total Area:.998 sq ft, 2 facets The are 0 sq ft of roof with a pitch below 3/12 (See Gray facets on Pitch Diagram) Y 463 536 _ 3 i e - jqq 4 � W 7 N, 4 E -,Note: This diagram shows the square feet of each roof facet (rounded to the nearest foot). The total area in square feet, at the top of this page, is based on the non-rounded values of each roof . facet(rounded to the nearest square foot being totaled). . � �EP} C1HNL¢CLVO1tE1zisu Lft�£ 7 S� f Apr 04 2016 15: 08 PAUL STAHL 7726008099 p. 8` HOME IMPROVEMENT CONTRACT PLEASE READ THIS CONTRACT ROOFING SPECIFICATION SHEET DESCRIPTION OF WORK Customer Name: M/M Ward Meese Date: 3/3(112016 Branch Name: Miami Paul Job#: 8831331+ Sales Cons l ltant• Paul Stahl . Stahl �.a ;,ej x-.:...c' .i�:.::3 �as',�..:M�� _ L.S.>,:':F..:':.-.. ,-n:•:,' Hurricane Mitigation=No, Premium 10 Year,Atlas Pinnacle LT,Atlas Pinnacle LT=Desert Number of Squares(excluding Low Slope)=10.66, Number of Flat Roof Squares=0 Flashing ' Misc Linear Ft of Drip Edge to be Installed=150, Color of Drip Rigid Ridge Vent=Yes, Linear.Ft Ridge Vent to be Edge to be Installed=White Installed=36, Rigid Ridge Vent- Color=Black,Off Ridge Vent=No,jReplace Fascia=No, Hurricane Mitigation Inspection=No Pricing Includes: i Drip Edge--in 10ft Sgmts $170.00 Shingle Removal and Application $5,203:00 .Y Homeowner comments: located in Ocean Resorts, ii��_M1 IN ME WE If rotted o 1 damaged wood is discovered AFTER removing the existing roofing,or could not be identified at the time of sale,there will be an additional charge of$ 72 per sheet of 4x8 sheathing and/or$ 6 per linear ft,of dimensional lumber for decking. If additional layers of roofing are discovered AFTER removing the first layer,or could not be identified at the time of sale,there will be an additional charge per square to remove each additional layer based on product to.be removed: $ 21 for composition shingles,$ 55 for wood shingles. Low or flat roofs will be priced on a per job basis based on. complexity. i I 06!17114-SA i. Page 7 .or 8 - •- FloridaBuildingCode Online Page 1 of 2 IME .•t �1 1i lud'.a YE'(1 rEl`Of BCIS Home Log In User Registration i�Hot Topics x Submit Surcharge i Stats&Facts Publications FBC Staff BCIS Site Map 4 Links j Search Busines.%j Prof6sibrial $ I Pro Pct Approval Regulation Product Aooroval Menu>Product or Anolication Search>Application List>Application Detail f i hI FL# FL16305-R3 Application Type Revision Code Version 2014 Application Status Approved Comments Archived M Product Manufacturer Atlas Roofing Corporation Address/Phone/Email. 2000 RiverEdge Parkway Suite 800 Atlanta,GA 30328 (770)946-4571 mcol l ins@ atl asroof i ng.com Authorized Signature Meldrin Collins mcoll ins@atlasroofing.com Technical Representative Ed Todd Address/Phone/Email 2000 Riveredge Pkwy Suite 800 Atlanta,GA 30328 (770)933-4477 etodd@atlasroofi ng.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer R�' Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report j Florida License PE-74021 Quality Assurance Entity LIL LLC i Quality Assurance Contract Expiration Date 12/31/2020 i Validated By Locke Bowden Validation Checklist-Hardcopy Received Certificate of Independence FL16305 R3 COI ATL13002.3 2014 FBC Product Evaluation Shingles- Fin I f Referenced Standard and Year(of Standard) Standard Year ASTM D 3161 2009 ASTM D 3462 2009 ASTM'D 7158 2008 TAS 100 1995 TAS.107 1995 Equivalence of Product Standards Certified By hops:%/floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquJBMjgU1j3N1TGPI... ' 7/1/20151 i Florida'Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/19/2015 Date Validated 04/20/2015 Date Pending FBC Approval 04/22/2015 Date Approved 06/22/2015 Date Revised 06/28/2015 Summary of Products FL# Model,Number or Name Description 16305.1 Atlas Shingles Fiberglass reinforced laminated asphalt Shingles Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16305'R3 II ATL13002.3 2014 FBC Product Evaluation Approved for use outside HVHZ:Yes Shingles-Final.odf Impact Resistant:N/A Verified By: Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use Evaluation Reports FL16305 R3 AE ATL13002.3 2014 FBC Product Evaluation Shingles-Final.pdf iCreated by`Independent Third Party: Yes Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 - The State of Florida isan AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to section 455.275(1),Florida Statutes,effective October 1.2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to - supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: �'�•.i fCfltk JCcurit'HSI't v, I 1 i - I https://flo.ridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquJBMj gU l j 3N 1 TGPI... 7/1/2015 Certificate of Authorization No. 29824 C R E E 17520 Edinburgh Dr -` Tampa, FL 33647 Technical Services, LLC (813)480-3421 EVALUATION REPORT. 2014 FLORIDA BUILDING CODE Manufacturer: ATLAS ROOFING CORPORATION Issued April 19, 2015 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770)612-6267 Manufacturing Plants:. Hampton, GA Meridian, MS Dangerfield,TX Ardmore, OK Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: . Asphalt Shingles Code Sections: 1507:2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain -REFERENCES En ti Report No. Standard Year PR II Construction Materials Technologies(TST5878) ATL-079-02-01 ASTM D 3161 2009 TAS 107 1995 PRI Construction Materials Technologies(TST5878) ATL-083-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-086-02-01 Rev 1 ASTM D 3462 2009 PRI Construction Materials Technologies(TST5878) ATLA 04-02-01 ASTM D 3462 2009 PRII Construction Materials Technologies(TST5878) ATL-106-02-01 ASTM D 3161 2009 TAS 107 1995 PRII Construction Materials Technologies(TST5878) ATL-106-02-01 Rev 1 ASTM D 3161 2009 TAS 107 1995 PRI Construction Materials Technologies(TST5878) ATLA 07-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-107-02-01.1 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATLA 09-02-01 ASTM D 7158 2008d PRI Construction Materials Technologies(TST5878) ATLA 16-02-01 ASTM D 3462 2009 PRI Construction Materials Technologies(TST5878) ATL-118-02-01 ASTM D 3462 2009 . . PRI Construction Materials Technologies(TST5878) ATL-119-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-123-02-01 ASTM D 7158 2008d, PRI Construction Materials Technologies(TST5878) ATL-125-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-127-02-01 Rev 1 ASTM D 7158 2008d PRI Construction Materials Technologies(TST5878) ATL-132-02-01 ASTM D 3161 2009 TAS 107 1995 PRI Construction Materials Technologies(TST5878) ATL-133-02-01 ASTM D 3161 2009 j TAS 107 1995 PRI Construction Materials Technologies(TST5878) ATL-135-02-01 ASTM D 3462 2009 PRI Construction.Materials Technologies(TST5878) ATL-136-02-01 ASTM D 3462 2009 PRI Construction Materials Technologies(TST5878) ATL-137-02-01 Rev 1 ASTM D 7158 2008d PRI Construction Materials Technologies(TST5878) ATLA 38-02-01 Rev 1 ASTM D 7158 2008d PRI Construction Materials Technologies(TST5878) ATL-143-02-01 ASTM D 3161 2009 TAS 107 1995 PRI Construction Materials Technologies(TST5878) ATL-14-02-01 ASTM D 3161 2009 TAS 107 1995 PRI Construction Materials Technologies(TST5878) ATLA 51-02-01 ASTM D 3462 2009 PRI Construction Materials Technologies(TST5878) ATLA 62-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATLA 67-02-01 ASTM D 3161 2009 PRI Construction Materials Technologies(TST5878) ATLA 68-02-01 ASTM D 3161 2009 TAS 107 1995 PRI Construction Materials Technologies(TST5878) ATL-169-02-01 ASTM D 3462 2009 PRI Construction Materials Technologies(TST5878) ATLA 70-02-01 ASTM D 3462 2009 ATL13002.3 ' FL 16305-R3 Page 1 of 8 This evaluation report.is provided for State of,Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. - .This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. { d:EJQREE' KATLAS ROOFING CORPORATION Asphalt Shingles Technica I Services, LLC PRI Construction Materials Technologies(TST5878) ATL-171-02-01 ASTM D 3462 2009 PRI Construction Materials Technologies(TST5878) ATL-172-02-01 ASTM D 3462 2009 PRI Construction Materials Technologies(TST5878) ATLA 74-02-01 ASTM D 3462 2009 PRI Construction Materials Technologies(TST5878) ATLA 79-02-01 TAS 100 1995 PRODUCT.DESCRIPTION GlalssMaster@30 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, (Ardmore&Hampton) thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. i . Tough-Master®20 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, (Ardmore&Hampton) thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Pr -Cut@ Hip&Ridge ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle with a (Ardmore&Hampton) dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Pro-Cut@ Starter Strip ASTM D 3161, Class F fiberglass reinforced, starter asphalt shingle with a dashed, (Hampton) thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Pr LAMTm Architectural ASTM D 3161, Class F&ASTM D 7158, Class H fiberglass reinforced, laminated (Hampton&Meridian) architectural asphalt shingle with a dashed,thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Pinnacle®Pristine, ASTM D 3161, Class F&ASTM D 7158, Class H fiberglass reinforced, laminated Pinnacle®Pristine architectural asphalt shingle with two dashed,thermally-activated, self-sealing sealant Lifetime w/Scotchgard stripes that complies with ASTM D 3462. (Dangerfield, Hampton& Meridian) St I rmMaster@ Shake ASTM D 3161, Class F&ASTM D 7158, Class H fiberglass reinforced, laminated -(Dal ngerfield) architectural modified asphalt shingle with two dashed,thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. INSTALLATION GlassMaster@ 30& Basic Wind Speed(V„i,): Max. 194 mph Tough-Master@ 20 Basic Wind Speed (Vasd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the -Atlas Roofing "Corporation when installing at slope- greater than 21:12. . Installation(HVHZ): Installed with 5-5/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): : Installed with 5-5/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail ` Pattern"or"6 Nail Pattern"detailed below. I ATL13002.3 . FL 16305-R3 Page 2 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not . specificallyaddressed herein. f - - ATLAS ROOFING CORPORATION CREEK Asphalt Shingles Technica I Services, LLC I 3W NIoI WM oft MW am: UK own 12" r ■ ■ i 127 x '71 Figure 1. GlassMaster®30&Tough-Master®20 4 Nail Pattern (Non-HVHZ only) Mails 12" 12," —>�-12" — Jj- 12" d Figure 2. GlassMaster®30&Tough-Master®20 6 Nail Pattern i i i _ 1 ATL13002.3 FL 16305-R3 Page 3 of 8 This.evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not , specifically addressed herein. i = (,( ATLAS ROOFING CORPORATION W'' C'R E E I \ Asphalt Shingles Technica1.Services, LLC Pro LAMTM.Architectural Basic Wind Speed(V„u): Max. 194 mph Basic Wind Speed(Vasd): Max. 150 mph Deck(HVHZ):. In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new. construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in.plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with,FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation(HVHZ): Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's. published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. Alin,12 ga.gaWNzod roofing nail rriN min.3i8"hea0 _[ TYP 14' 1=1 ED [CD 0 0 0 oT g• B 1114" Figure 3. ProLAMTm Architectural Shingle 4 Nail Pattern (non-HVHZ only) i i IMtn.12 ga.gaNanlnd.dog Owk roofing ne8 i - I I w2hmin.318'head 112" T YP I z � T- 7 a y .__.._ .......... i- -� - -------.......... ,---- Figure 4. Pro-LAMTm Architectural Shingle 6 Nail Pattern AT,L13002.3 FL 16305-R3 Page 4 of 8 This-evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify-CREEK Technical Services,LLC of any product changes.or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not. specifically addressed herein. i I CREEK ATLAS ROOFING CORPORATION Asphalt Shingles ' Technica I Services, LLC Pinnacle.®Pristine& Basic Wind Speed(V it): Max. 194 mph StormMasterO Shake Basic Wind Speed(Vagd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation(HVHZ): Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be.attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 6in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. i 39 3/6' i 1 ............_.........__..__._._...__._—----------- ......— _:n 12 ga.gaNanlzatl r"oM9 ting . xglh mfn.3l6°heetl r 72,lt2 '— ' �TYP I Cy' L_J r= C7 14• ....... t._.7 (—) C". �rC_) U C.._.1 C_J C—J 6718' l I ) - f.. Figure S. Pinnacle®Pristine and StormMaster®Shake 4 Nail Pattern (Non-HVHZ only) -- 398x8` . 12 9".gakarared:ing Snank nag _._..m;n min.3t6'nada 71r� r CT i0 O t=) Oq CJ O O o o� O O O' O CI O .� O O D O tn. O O O Cl C-) O O. O O O O f� _O_ O O O O O 1 Figure 6. Pinnacle®Pristine and StormMaster®Shake 6 Nail Pattern AT-L13002.3 FL 16305-R3 Page 5 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ' I i CREEK ATLAS ROOFING CORPORATION K C Asphalt Shingles Technica I Services, LLC Pro Cut®Starter Strip Basic Wind Speed(Vuit): Max. 194 mph Basic Wind Speed(Vasd): Max:150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min.,19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at 'slope greater than 21:12. Installation(HVHZ): Installed in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached as shown below. Installation (Non-HVHZ): Installed in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached as shown below. - 36" i --i u• Ffa pton 12 ga.1.1/2"ring Shank nail Figure 7. Pro-Cut®Starter Strip I 1. I ATL13002.3 FL 16305-R3 Page 6 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report.is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. l I EiCREEK ATLAS ROOFING CORPORATION Asphalt Shingles Technica I Services,-LLC Pro-Cut®Hip&Ridge Basic Wind Speed(Vui,): Max. 194 mph Basic Wind.Speed(Vasa): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Installation(HVHZ and Installed with 5-5/8.inch exposure in accordance with RAS non-HVHZ): 115 (HVHZ only) and manufacturers published installation instructions. The direction of the exposed end shall be away from the prevailing wind. I----12" 12 ga.1-1/2"ring r shank nail i 12" - i G" j LlI Figure 7. Pro-Cut®Hip& Ridge i ATL13002:3 FL 16305-R3 Page 7 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC.of any.product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. , CREEK ATLAS ROOFING CORPORATION G C Asphalt Shingles m;. Technica I Services, LLC LIMITATIONS 1) Fire.Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 33-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting.at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products. evaluated herein.by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida . Building Code as evidenced in the referenced documents submitted by the named manufacturer. �R�rp��� No 74021 2015.04.1 * 9 14:10:16 STATE OF 04t00' 4 R 1�, ,� Zachary R. Priest, P.E. i,/,IONA\-'--%. Florida Registration No.74021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE i CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC'is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved.in the approval process of the product. END OF REPORT ATI-13002.3 FL 16305-R3 Page 8 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I I Florida Building Code Online Page 1 of 2 F'C da PynAkgJp..td BCIS Home Log In User Registration I Hot Topics i Submit Surcharge ' Stats&Facts ! Publications 's FBC Staff Busines i s;}Product Approval 6a1 USER: Public User r _ Product Approval Menu > Product or Application Search >Application List>Application Detail FL# FL6267-R9 Application Type Revision Code Version 2014 Application Status Approved Comments Archived :. Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (973) 872-4421 lindareith@trinityerd.com Authorized Signature Beth McSorley lindareith@trinityerd.com Technical Representative Beth McSorley (current) Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (973) 872-4421 bmcsorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part c ..Compliance Method Evaluation Report from a Florida Registered Ai Professional Engineer 0 Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity LIL LLC Quality Assurance Contract Expiration Date 01/27/2016 Validated By John W. Knezevich, PE s Validation Checklist- Hardcopy Received Certificate of Independence FL6267 R9 COI 2015 01 COI Nieminen.pdf Referenced Standard and Year (of Standard) Standard ASTM G155 J https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw..: 7/8/2015 i > Florida Building Code Online Page 2 of.2 TAS 100(A) TAS 110 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/06/2015 Date Validated 04/08/2015 Date Pending FBC Approval 04/12/2015 Date Approved 06/23/2015 Summary of Products F Model, Number or Name Description 6267.1 GAF Roof Ventilation Products Low profile roof ridge vents Limits of Use Instal lation.Instructions Approved for use in HVHZ: No FL6267 R9 11 2015 04 FINAL G Approved for use outside HVHZ: Yes Verified By: Robert Nieminen PE-5 Impact Resistant: N/A Created by Independent Third Par- Design arDesign Pressure: N/A Evaluation Reports Other: Refer to ER Section 5 for Limits of Use. FL6267 R9 AE 2015 04 FINAL R9.pdf Created by Independent Third Par Back Next Contact Us :: 1940 North Monroe Street.Tallahassee FL 32399 Phone: 850-487-182 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibili Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, pleE to Section 455.275(1), Florida Statutes, effective October 1,2012, licensees licensed under Chapter 455, F.S. must pr address if they have one.The emails provided may be used for official communication with the licensee. However emai do not wish to supply a personal address, please provide the Department with an email address which can be made av you are a licensee under Chapter 455, F.S., please click here.. Product Approval Accepts: 0 AN ` scxicril">nccuix . i I i i hops://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw..: 7/8/2015; EXTERIOR RESEARCH&DESIGN,LLC. B'- Certificate of Authorization#9503 TRI 353 CHRISTIAN STREET, UNIT#13 TY ER® OXFORD,CT 06478 . PHONE: (203)262-9245 FAX:(203)262-9243 EVALUATION REPORT GAF Evaluation Report 01506.02.06-119 1 Campus Drive FL6267-119 Parsippany, NJ 07054 Date of Issuance:02/28/2006 Revision 9:04/02/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. foi use of the product under the Florida Building Code and Florida Building Code, Residential.Volume. The products described herein have been evaluated for compliance with the 5t''Edition (2014) Florida Building Code sections referenced herein. DESCRI ION: GAF Roof Ventilation Products LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of.this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this_entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared Py:., . j. Robert 1.M.'Nieminen P.E. The facsimile seal appearing was authorized by Robert Nieminen, %'� r�,C�;;'.•!j � P.E.on 04/02/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 ,.',saiou��`�{.•55; document.Signed,sealed hardcopies have been transmitted to the ,e.1Jtq,"t't�sst Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for whjich the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5.. Ths'is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this'Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. I `` TRIO ERD ` ROOFING COMPONENT EVALUATION: 1.. !SCOPE' Product Category: Roofing. Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: GAF Roof Ventilation Products,as produced by GAF,have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1523.6.5.2.13 Wind Driven Rain TAS 100(A) 1995 1523.6.5.2.13:1 Physical Properties TAS 110 2000 2614.2 Weatherometer ASTM G155 2005 3. REFERENCES: Entity Examination Reference Date ATI(TST 1558) Physical Properties 01-49035.01 03/02/2004 ATI(TST 1558) Wind Driven Rain -01-44964.01 01/15/2004 ATI(TST 1558) Wind Driven Rain 60172.01-122-18 10/07/2005 ATI(TST 1558) Physical Properties 59665.02-106-31 09/16/2005 ATI(TST 1558) Wind Driven Rain 84608.01-106-18 11/12/2008 ATI(TST 1558) Wind Driven Rain A5250.01-109-18 02/18/2011 PRI(TST 5878) Weatherometer HBP-007-02-01 06/24/2004 PRI(TST 5878) Physical Properties HBP-002-02-01 06/06/2001 PRI(TST 5878) Wind Driven Rain HBP-01-02-01 11/02/2000 PRI(TST 5878) Wind Driven Rain. BRY-021-02-01 12/31/2003 PRI(TST 5878) Physical Properties BRY-025-02-01 09/17/2004 PRI(TST 5878) Physical Properties . GAF-138-02-06 02/09/2007 PRI(TST 5878) Wind Driven Rain' GAF-138-02-04 02/09/2007 PRI(FST 5878) Wind Driven Rain GAF-31.0-02-01 07/07/2011 ETC Labs(TST 2411) Physical Properties ETC-01-718-10379.0 01/16/2000 ETC Labs(TST 2411) Physical Properties ETC-03-718-14602.0 01/20/2004 ETC Labs(TST 2411) Physical Properties ETC-07-718-19959.0 09/27/2007 Miami-Dade(CER 1592) Various Various NOAs Current UL,LLC..(QUA 9625) Quality Control Inspection Report,R15072 01/27/2015 4: PRODUCT DESCRIPTION: 4.1 Cobra®Exhaust Vent is a low-profile attic ridge vent of mesh-construction for use in shingle roof systems. The product measures 101/2-inch wide supplied in 20 and 50 ft long rolls,and is supplied with 13/"coil nails or 2%"Smart Nails-. 4.2 -Cobra® Rigid Vent Ym is a plastic, low-profile attic ridge vent for use in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and.is supplied with 3-inch ring shank nails. 4.3 Cobra® Rigid Vent 3'"- 9" is�a plastic, low-profile attic ridge vent for use in shingle roof systems with 10-inch width ridge caps. The product measures 11'/2-inch wide supplied in 48-inch,long sections, and is supplied with 3-inch ring . shank nails. 4.4 Cobra®Snow Country'"is a plastic,low-profile attic ridge vent with filter for use in shingle roof systems. The product measures 13-13/16-inch wide supplied in 48-inch long sections 4.5 Cobra"Snow Country AdvanceclTM is a plastic,low-profile attic ridge vent with filter for use in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and is supplied with 3-inch ring shank nails. 4.6 . Cobra®Snow Country Advanced*"-9"is a plastic,low-profile attic ridge vent with filter for use in shingle roof systems with 10-inch width ridge caps. The product measures 11'/2-inch wide supplied in.48-inch long sections,and is supplied with 3-inch ring shank nails. 4.7 Cobra® Ridge Runner® is a polypropylene plastic, low-profile attic ridge vent for use in shingle roof systems. The product measures 111/2-inch wide supplied in 20 ft long rolls,and is supplied with 1%"coil nails. Exterior Research and Design,I.I.C. Evaluation Report 01506.02.06-R9 c.,tia.te o_(Authorization#9503 FL6267-119 Revision 9:04/02/2015 Page 2 of 8. TRINI` Y ERD 4.8 TruSlate@ Ridge Vent is a plastic, low-profile attic ridge vent for use in TruSlate®roof systems. The product measures 11.4-inch wide supplied in 48-inch long sections. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Minimum slopes are as follows: Product Minimum Slope Cobra®Exhaust Vent 2:12 Cobra®Rigid Vent 31" 3:12 Cobra®Rigid Vent 3"-9" 3:12 Cobra®Snow Country'" 3:12 Cobra®Snow Country Advanced" 3:12 Cobra®Snow Country Advanced"-9" 3:12 Cobra®Ridge Runner® 3:12 TruSlate®Ridge Vent 5:12 5.4 The maximum mean roof height for Cobra®Exhaust Vent,Cobra®Rigid Vent 3,Cobra®Rigid Vent 3—9",Cobra®Snow Country-, Cobra® Snow Country AdvancedT", Cobra® Snow Country Advanced T" — 911 , Cobra® Ridge Runner® and TruSlate®Ridge Vent shall be 33 ft. 5.5 Installation shall result in minimum net free ventilation area requirements set forth in FBC Sections 1203.2. When more . than one level of roof ridge existing over a single attic space,use ridge vents only at the high ridge. 6. INSTALLATION: 6.1 GAF Roof Ventilation Products shall be installed in accordance with GAF published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. i Exierior Research and Design,I.I.C. Evaluation Report 01506.02.067119 Certificate ofAuthorization#9503 FL6267-119 Revision 9:04/02/2015 . Page 3 of 8 i f ITRINITY1 ERD 6.2 COBRA®EXHAUST VENT: I 6.2.1 Chalk a cut-line 1-inch off each side of the ridge and cut a slot along the apex of the roof measuring 2-inch(for truss construction)or 3'/2-inch(for ridge pole construction). The slot should terminate 6-inches from each end and 12-inches from hip intersections or chimneys. Cut only the sheathing;do not cut trusses.Figure A. 6.2.2 Unroll the vent along the entire length of the ridge,covering uncut 6-inch sheathing area on both ends. Shorter lengths can be joined by caulking and butting the ends. Figure B. 6.2.3 Apply a bead of polyurethane roof sealant to the underside of the entire perimeter,of the vent and nail with min.2'h- inch galvanized roofing nails at each corner and 10-inch o.c. Do not use excessive roof cement, as it may result in shingle blistering. 6.2.4 Apply a bead of polyurethane roof sealant in the shape of a °C to the underside of the entire perimeter of the cap shingles,and install cap shingles directly over the vent using Smart Nails'""or 134 inch coil nails(supplied with the vent. Figure C. Do not use excessive roof cement,as it may result in shingle blistering. �- I 6.2.5 Cobra®Exhaust Vent(hand nail version)and Cobra®Exhaust Vent(nail gun version)have a 3/4-inch or 5/8-inch nominal thickness, respectively, to facilitate ventilation. Care shall be taken not to crush or compact the product during installation. Figure D. • - 3/4-. 5$.. . Hand-Nail Version Nail Gun Version Exterior Research and Design,LLC. Evaluation Report 01506.02.06-R9 Certificate o/Authoriration#9503 FL6267-R9 Revision 9:04/02/2015 Page 4 of 8 i j ll I . '\ITRINITYJERD 6.3 COBRA®RIGID VENT 3T"',RIGID VENT 3TM-9",SNOW COUNTRYT".SNOW COUNTRY ADVANCED'"'AND SNOW COUNTRY ADVANCEDT"-9": 6.3.1 Mark-off and cut the slot opening as follows,ensuring that the ends of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys. ➢ No Ridge Board:Cut a 7/8-inch opening on each side of the ridge(Figure A). ➢ With Ridge Board: Cut a 1-5/8-inch opening on each side of the ridge(Figure B). 7/8" 7/a v I I ' 1'3;4„ 3'/a" No Ridge Board With Ridge Board 6.3.2 Sealant: Apply a.bead of silicone caulking or roof cement to the underside of the outer baffle along both edges and at exposed ends,ensuring the outside edges where the vent meets the shingles are sealed with the caulk or flashing 'cement. 6.3.31 Vent Placement: Starting at one end of the slot,place,center and conform the Cobra°.rigid vent over the slot with the vent firmly against the roof surface,ensuring the vent extends past the slot opening by at least 6-inch. 6.3.4 Fasteners: For Cobra®Rigid Vent 3T",Cobra®Rigid Vent 3'"'-9",Cobra®Snow Country Advanced'"'and Cobra®Snow Country AdvancedTm-9"only,use the 3"ring shank nails(included). For Cobrae Snow Country'"',use nails at least I% inch or longer. Nails must always penetrate through plywood decks or at least 3/4-inch into wood planks. NOTE:GAF recommends 3-inch ring shank nails for increased uplift resistance. - .. 6.3.5 Spacing: Attach the vent section through the pre-molded nailing holes located at 3,12,24,36 and 45-inch from the start of each 48-inch vent piece. 6.3.6 Joints: Apply the subsequent Cobra®rigid vent sections over the length of the ridge using the overlap/underlap tabs. 6.3.7 Ridge Shingles: Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using nails detailed in 6.3.4. A nail line is inscribed on top of the Cobra®rigid vent to serve as a guide. j Exterior Research and Design,LLC: Evaluation Report 01506.02.06-R9 Certificate olAuthmiration#9503, FL6267-119 Revision 9:04/02/2015 Page 5 of 8 I I � ��� ERD - 6.4 COBRA®RIDGE RUNNER® I 6.4.1 Cut slot per 6.3.1. . 6.4.2 Tear a 1-foot section to be used as a template for laying the vent out(Figure E-G)and center the template/locator over the ridge cap shingles at the beginning of the vent slot.Note the location of the baffle(Figure H).Make sure to do this at both ends of the installation. I 6.4.3 Measure the distance from the edge of the roof slot to the exterior baffle(D).Establish a chalk line along one side of the ridge(Figure 1). Unroll the vent and use the included 1-3/4-inch pneumatic roofing nails to attach the first side of the ridge vent with the exterior of the baffle aligned with the chalk line (Figure J). Proceed with using the 1' interval EasyTear"system to custom size the vent to the appropriate length.If the EasyTearM system can not be utilized,use a utility knife to size the vent. Nail gun targets are,embossed on the part as a guide for property attaching vent to the roof.The vent should be fastened on 6-inch centers(Figure K). CHALK LINE 6.4.4 NOTE:When fastening the vent and cap shingles, be sure that the included 1 3/4-inch coil nails completely penetrate plywood or provide at least 3/4-inch penetration into wood planks.In the case they do not,you must use alternate nails that provide the required penetration. Proceed with attaching the other side of the vent.When beginning to nail down the second side, do NOT begin at the end; begin between the first and second one-foot sections and then return to fasten the first one-foot section.This will allow for proper fit. Exterior Research and Design,LLC. Evaluation Report 01506.02.06-R9 Certificate ofAuthorization#9503 FL6267-R9 Revision 9:04/02/2015 Page 69f 8 i ERCP TRI ITY� 6.4.5 Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using the nail-lines on top of the ridge vent for proper lapping. 6.5 TRUSLATER RIDGE TIENT: I 6.5.1 DO NOT use on hips. 6.5.2 Intall TruSlate®Ridge Vent before installing the field slates. 6.5.3 After determining the total length of TruSlate®Ridge Vent required(for proper ventilation), determine the necessary" slot opening. Mark-off and cut the slot opening, ensuring the ends of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys. 6.5.3.1 Roofs without a ridge board:Cut a 7/8-inch opening along the ridge on each side(Figure A). 16.5.3.2 Roofs with a ridge board: Cut a 1-5/8-inch opening along the ridge on each side(Figure B). Fig. A Fig. B (41 mm)17 ty8(41 mm) (22 mm)7/84 18"(22 mm) L1 Ui(82 mm) With Ridge Board [13/4°.(44 iron) No Ridge Board 6.5.4 Install an_18-inch.wide section.of ASTM D1970 self-adhering leak barrier(holding Florida Statewide Product Approval or Approved on a Local Basis)from the edge of the ridge slot extending down towards the roof deck on both side of the slot. 6.5.5 Place the TruSlate® Ridge Vent over the ridge slot, "peaked" and centered over the ridge slot, and attach using minimum 3-inch long ring-shank nails through the pre-molded nail holes on the vent,located 3-inch from the ends and 9-inch o.c. Fasteners shall penetrate through plywood decks or embed minimum 3/4-inch into wood plank decks. 6.5.6 Continue over the length of the ridge, utilizing the male/female connectors to connect units. Ensure the finished ends include the pre-molded end caps. Cover all exposed nail heads on the vent with silicone caulk. Intall a bead of exterior grade silicone sealant at the downslope leading edges of the ridge vent,at the junction of the leading edge and the leak-barrier below. 6.5.7 Install the top course of TruSlate® field slates, UnderBlock'" UV & Moisture Barrier and TruSlate_® trim slates in accordance with.GAF published installation instructions. Intall TruSlate® trim slates with 10-inch exposure using minimum 1-5/8-inch long deck screws through pre-drilled holes,through the ridge vent to engage the wood deck. jAa Z Paaf Uc%;k Prota:tio» 18414„ 257 mm ryszp, vewither WaldVF3 of Ston»Gaard(n)Leak Bonier Exterior Research and Design,LLC. Evaluation Report 01506.02.06-R9 Certircate of Authorization 09503 FL6267-R9 Revision 9:04/02/2015 " I Page 7 of 8 I ' Q�TRIN"JERD 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. H. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE.ENTITY: UL,LLC.—QUA9625;(847)664-3281 -END OF EVALUATION REPORT- E terior Research and Design,U.C. Evaluation Report 01506.02.06-119 certwcate of Authorization#9503 FL6267-119 t Revision 9:04/02/2015 Page 8 of 8