Loading...
HomeMy WebLinkAboutProduct Approval �.1�_��1T' •kl�'�xa i � E C L�Sv+s l % �a�r ��� 19 � EXTERIOR RESEARCH& DESIGN, LLC. 16 certificate of Authorization 0503 � � ry E®f� PERMITTliiIC= 353 CHRISTIAN STREET,UNIT013 St. Lucie County, L OXFORD,CT 06478 PHONE:(203)"262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R6 One Owens Corning Parkway FL10674-R11 Toledo,OH 43659" Date of Issuance:02/06/2012 Revision 6: 10/15/2015 SCOPE: This Evaluation Report ,is issued under Rule 61G20-3 and the applicable rules and "regulations governing the use of construction materials in the State of.Florida.The documentation submitted has been reviewed.by Robert Niemihen,.P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition.(2014)Florida,Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.. CONTINUED COMPLIANCE: This Evaluation Report is "valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation,,changes. Trinity requires a-complete _review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation" Report number preceded. by the-words, "TrinitylERD Evaluated" may be displayed 'in advertising literature. If any portion of the Evaluation Report'is,displayed;ten it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or,its distributors and•shall be avai"lable.for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages"1 through 7. Prepared by: y g�fi A, y tC r+ , The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M.Nieminen,P.E. •��s� x ��e„;\ sts•: P.E.on 10/15/2015.This does not serve as an electronically signed Florida Registration N0.59166,Florida DCA ANE1983 document Signed,sealed harcimpies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned,operated orcontrolled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor Will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does.not have,nor will acquire;a1inancial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity[ERD nor.Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. i �JTRINFY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,:R965.2.4 Physical Properties ASTM b3462 2009 1507.2.7.1,R905:2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Enttt Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453;Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/].3/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic'and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles. m 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireTM'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration®, Duration® Premium. Cool, TruDefinition Duration Designer Color Collection,TruDefinition®Oakridge, Oakridge and WeatherGuardo HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire® Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge Shingles,Pro-Edge Hip&Ridge Shingles and DuraRidgell Hip&.Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part, of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 Certificate of Authorization#9503 FL10674-Rll Revision 6:'10/15/2015 Page 2 of 7 TRINITY�ERD 5.4 Wind'Classification: 5.4.1 All. Owens Corning shingles noted herein.are Classified in accordance with FBC Tables. 1507.2.7.1 and R905.2.6.1 to ASTM D3161,,Class F and/or ASTM D7158,Cla"s"s,H,indicating the.shingles are acceptable for us in all wind zones up to Vasd=150 mph (V„It=194 mph).. Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens.Corning hip & ridge shingles, Starter Stripy Shingle. and Starter Strip Plus noted herein are. Classified in accordance with;FBC Tables 1507.2.7.1,and 8905.2.6,1 to ASTM D3161, Class f, indicating the shingles are acceptable for us in all wind-zones up to Vasd= 150 mph (V„It= 194 mph). Refer to Section 6 forinstallation requirement to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations; by a qualified design professional are required for conditions outside these limitations: Contact the shingle'manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corningpublished information,on wind resistance and'installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building .Code and F.A.C.Rule 61620-3. 6. INSTALLATION: 6.1 UnderlyY meat: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61620-3,per FBC Sections 1507.2.3,.1507.2.4 or R905.2.3. 6.2 Asphalt Shingles. 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: ➢ Berkshire®shingles require minimum five(5)nails pershingle. > WeatherGuard'HP shingles require minimum six(6)nails per shingle. ➢ DevonshireTM'shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five($)nails ped strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall.be.in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or 11905:2.5. Staples are not permitted. 6.2.4 Where the.roof slope exceeds 21 units vertical in 12 units.horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum.Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck Felt underlayment Deck Seg-adhered WeatherLock® Self-adhered underlayment WeatherLocks underlayment Drip edge II Dag Drip edge d9 Na7s located Nails located r-3'from cave 2"-3"from eave it Install first Self-sealing adhesive Sdhsealing adhesive Instal first Starter Strip Plus eave Starter Stti9 positioned along eave with6'removed Positionedalon g shingle with 6"removed r y Starter�p Plus overhangs eaves and rakes 1/4--3/4' Starter Strip shingle overhangs eaves and rakes/i_h" g Exterior Research and.Design,LLC. Evaluation Report 037940.02.12-R6 Certificate of Autharization#9503 F L10674-Rll Revision 6:10/15/2015 Page 3 of 7 c QOTRINITY]ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard ora Normal Mansard or Area para Wind Areas High Wind desvanes y Wind Areas High Wind desvanes y Area para vientos normates Areas vientos fuertes Area para vientos normales Areas vientos fuertes T. • z• (B z' t'l z" t. �r »• �zt 121 ° 5"Exposure •5 5/8"Exposure Expositidn Ex' osiet6n P 6.2.7 Minimum Nailing—Berkshire®: Sealant strip Sealant strip La tlra de Wader La tha da sellador t' A1A' hof 9Yf 8Vf t "gof 8 Y aof sof r r 2" Asphalt roofing cement Cemento de techo de asfalto 6.2.8 Minimum Nailing—Devonshire'": Nails r ire �.-. r✓r sa• _ _ _ w. Nails Ten 1"Spots of Asphalt Roof Cement Exterior Research and Design,LLC. Evaluation Report 637940.02.12-116 Certificate ojAuthodzotion#9503 FL10674-R11 Revision 6:10/15/2015 Page 4 of 7 �TRINI tl f (ERD II 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition Duration. Designer Color Collection: lArsardand Steep Stop@ 4 Nail Pattern INail fasten oehveen S.t, Esquema de 4 clavos Pattern areaandtop o cut out. ESquema mh sa b op MF.etes St4gUil°fastening ama width da 6 clavos as dasRnd�erthe el Area deelawsSumNalo dreaSueNaB rbparta ... —1 s�ariadelrauta SureNaB o \ SureNai(a 1' 1' tastem'n� � _ (adening area ti' area width _ �• "12' _ Araada r — \1 Amada. dams Su�reNaB® F 12' ` ^17';.. SuteNalp LE 5/e"Exposum Nails 53ea"Exposure 55h pulg.de exposicicn Clavus 5sh ping.de exposicTon 5sle"Exposure Nails 5%'Exposure 5%pulg.de erposkl6n Cfavos 5'h ping.de exposkio 6.2,.-10 Minimum Nailing.—TruD"efinition'Oakridge®,Oakridge°: 4 Nail Pattern 6 Nail Pattern Esquema con 4 clavos Esquema con 6 clavos V 1' 1• r 5 Ve"Exposure Nails 5.518"Exposum Nails- 5 5/8"Exposure Exposicl6ado65/8Pul9•, Clavus Exposkidn de 6 618pulg. 55/G"Exposure clavos Exposle46nde 5618pu/g. Eaposfcl6a de 5618pulg. 6.2.11 Minimum Nailing—WeatherGuard® HP: ■ Rlnpl.6lde ViewI� Z,=4 1/IsE�labral 1-2 s; { j• F"tMM 76tw IIYI ilir- aie 6.3 Hip&Ridge Shingles: m 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,WeatherGuard HP Hip and Ridge Shingles and PrciEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of.DuraRidgel Hip & Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation-limitations„including the use of hand-sealing for wind warranties. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6 Certffcvte ojAuthorizotion N9503 FL0/15/1015 Revision 6:10/15/2015 Page 5 of 7 1-RINI-ry I ERD 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6-or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 T Fig.2 — PnepaltlnDWlnd Direction A TopVlM sideView Nails Nails A Nails flails 4 1" Top Laminated 2" t Piece I I 4 I I. I I I I A I i I I I A I I I I I y i V r =i �posure mI VI I I I I I I 12' 1 1 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: em Fig. 2 - High Wind Fastening Pattem (4 Nails rim Shingle rEX --r d Discard - Cess 14P 711 Sealant -� Strip12" ' Fastening. 55/0 5"Exposure Distance 12 6.3.5 Minimum Nailing—Weatherduard® HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A 4v TopVWi preuaONg Wind �—Dlreelbn p A Nails A � � Halls Halls A I I 7'• I ri 2. I I A 1 I rsposure g' Exposure 17 Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 Certiflmte of Authorization 119503 F L10674-R11 Revision 6:10/15/2015 Page 6 of 7' '\,�TRINITYJERD 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind DirectionFastening Sealer�tStrip � Pattern fi°Exposure • 12° 1 Sealant Fasten 711 6"Exposure Cover Exposed 1 Fasteners with Roof Cement I•-12° 6.3.7 Minimum Nailing—DuraRidge m Hip.&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning.published installation,instructions for their minimurri.requirements. PrevailaiiWi d DirKidon Top View K—Diraaiondorninukocimnt We en plan Dinotd6nd■Ixi■n6opr■dornirenro I" Vlstasuperlor 1-y V N°tl s Clou p 2I' ■ 011ensCondng,SureNail' •. GbYO i X 1 1 - �I1b I I 8 sl�>`` C OM V F —I+12 — 1. 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2,7.1/R905.2.6:1. S. BUILDING PERMIT REQUIREMENTS: As requited.by the.Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625 (414)248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC: Evaluation Report 037940.02:12-R6 Certificate of Authorization#9503 FL10674-R11 Revision 6:10/15/2015 Page 7 of 7'