Loading...
HomeMy WebLinkAboutProduct Approval 2016 Florida Departments BCIS Home I Log In User Registration Hot Topics l Submit Surcharge I Stats&Facts Publications I FBC Staff I BCIS Site Map Links Search l Busines d L "` N Product Approval „''` Y Professi I USER: Public User Regulation Product Approval Menu>Product or Application Search>Application List>Application Detail • FL# FLl •r7-R1 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived J Product ManufacturerEaster rfti aura ys ems Address/Phone/Email 15341 DorreStl Ave. Ft. Myers, FL 33912 (800)432-2204 Ext 4314 thoard@easternmetal.com Authorized Signature Timothy Hoard thoard@easternmetal.com Technical Representative Timothy]. Hoard Address/Phone/Email 10030 Bavaria Road Fort Myers, FL 33913 (800)432-2204 Ext 4314 thoard@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Wi ws Subcategory ulJions Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications, Inc. Validated By Keystone Certifications, Inc. Referenced Standard and Year(of Standard) Standard Year AAMA 450 2010 TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 03/24/2015 Date Validated 04/02/2015 Date Pending FBC Approval Date Approved 05/08/2015 Summary of Products FL# Model,Number or Name Description 17472.1 HVHZ Clipped Aluminum Bay/Bow HVHZ Clipped Aluminum Bay/Bow Mullion Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL17472 R1 C CAC 622-104CAR.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/22/2018 Design Pressure: N/A Installation Instructions Other: See drawing set for mullion size, angle and design FL17472 R1 II PA-0004 HVHZ SS 2015-02-28.Ddf pressure rating Verified By: Hermes F. Norero, P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL17472 R1 AE PER3286 HVHZ SS 2015-02-28.pdf Created by Independent Third Party: Yes 17472.2 ,HYlI 'lipped A'lui iintlm ubeHVHZ Clipped Alu inum be Mullion Vertical, Horizontal,T Mullion and X Configurations Limits of U3 TERM on Agency Certificate Approved for use in HVHZ:Yes dF 7�472"RS C CAC 622r.10j AR:Ddf Approved for use outside HVHZ:Yes FL17472 R1 C CAC 622-102CA'R pd Impact Resistant:Yes _T —F�17472Ra1CaIC�AC622�103CAR.Pdf Design Pressure: N/A _� ,tiwat o+ ��FL17472R1�C'aCAC 622-SOSCAR.p f Other: See drawing sset.f ,ullionfslzd,configuration and FL17472 R1 C CAC 622-106CAR.pdf design pressure-ra�Ying- Quality Assurance Contract Expiration Date 07/18/2018 PInstallation Instructions - FL17A72RII�P4000 FiVHZ:SS 2015-02-28.pdf Verified By: Hermes F No'�reiio E473778 Created by Independent Third Party" YeS Evaluation Reports �I FL17472 R1 AE PER3285 HVHZ 5 2015-02-28.pdf Created by Independlen,-t0fid'Party: Yes Back Next Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement:: Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: WN® ECheck sccuritvst r:mics• Document Title: Doc No: FRM B1-02 Structural Performance Rev No: 7 Page: 1 Of: 1 "YS'TONg! Certification C6RTI�PICATION/B.I NCx 1� Authorization Report Required By: PRO B1-03 CAR & Product ID Number: 622 - 101.0 Issue Date: 1/16/2015 Revision Date: 4/1/2015 Expiration Date: 7/18/2018 Company Code: 622 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc. (KCI)after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. Licensee Information: Product Information: Eastern Architectural Systems Model Name: 1"x3-1/8" Light Alum Mullion HN/T/X 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Configuration: No Reinforcement Max. Width: See Table Max. Height: See Table Referenced Standard: Product Rating: AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-3010W-4A/5A Test Report Expiration: 7/18/2018 Authorized Signature: Keystone Certifications, Inc. 564 Old York Road, Suite 5 Digitally signed by Steven M.Urich Etters, Pennsylvania 17319 p1 qer cn=Steven M.Urich,o=Keystone CertiFlcations,lnc.,ou, Phone: 717-932-8500 email=surich@keystonecerts.com,c=US Fax: 717-932-8501 Date:2015.04.01 10:53:43-04'00' W W W.KEYSTONECERTS.COM Appendix n d i x 1 CAR No:622-101.0 yCERTIRICATtON6.INC. p p Expiration Date:7/18/2018 Ste{ Eastern Architectural Systems 10030 Bavaria Road Fort Myers, FL 33913 Load Tables for the: 1"x3-1/8" Light Aluminum Mullion, Horiz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION: 1"x 3-1/8" (LIGHT)-ONE-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 181.0 158.0 143.3 134.3 129.8 129.3 127.6 72 161.6 123.7 101.5 87.3 77.7 71.1 67.2 66.7 63.8 84 101.0 76.9 62.7 53.5 47.1 42.6 39.7 39.3 36.9 96 67.4 51.1 41.5 35.2 30.8 27.6 25.6 25.2 23.5 108 47.2 35.7 28.9 24.4 21.3 19.0 17.5 17.2 15.9 DESIGN PRESSURE LIMITS FOR MULLION: 1"x 3-1/8" (LIGHT) -TWO-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 191.4 167.5 151.3 148.9 134.0 48 200.0 200.0 200.0 167.5 143.6 125.6 113.5 111.7 100.5 60 200.0 200.0 160.8 134.0 114.9 100.5 90.8 89.3 80.4 72 157.6 118.2 94.5 78.8 67.5 59.1 53.4 52.5 47.3 84 99.2 74.4 59.5 49.6 42.5 37.2 33.6 33.1 29.8 96 66.5 49.9 39.9 33.2 28.5 24.9 22.5 22.2 19.9 108 46.7 35.0 1 28.0 23.3 20.0 17.5 15.8 1 15.6 14.0 Impact Ratings ASTM E1996-Wind Zone 4,Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant Keystone Certifications, Inc. 564 Old York Road,Suite 5 Etters, PA 17319 Phone:717.932.8500 www.keystonecerts.com Document Title: Doc No: FRM B1-02 Structural Performance Rev No: 7 Page: 1 Of: 1 ,kF-YSTONtl Certification CQitTIRIC/�TIONS. NC.g lll����ff Authorization Report Required By: PRO B1-03 CAR & Product ID Number: 622 - 102.0 Issue Date: 1/16/2015 Revision Date: 4/1/2015 Expiration Date: 7/18/2018 Company Code: 622 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI)after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. Licensee Information: Product Information: Eastern Architectural Systems Model Name: 1"x3-1/8" Heavy Alum Mullion HN/T/X 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Configuration: No Reinforcement Max. Width: See Table Max. Height: See Table Referenced Standard: Product Rating: AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-3010W-6A/7A Test Report Expiration: 7/18/2018 Authorized Signature_ : Keystone Certifications, Inc. 564 Old York Road, Suite 5 Digitally signed by Steven M.Urich Etters, Pennsylvania 17319 4 L n, / DN:cn=Steven M.Urich,o=Keystone Certifications,Inc.,ou, Phone: 717-932-8500 email=surich@keystonecerts.com,c=US Fax: 717-932-8501 Date:2015.04.01 10:59:24-04'00' W W W.KEYSTONECERTS.COM KEYS?ONCAR No:622-102.0 CERTI\FICATION/6.INCA: Appendix 1 Expiration Date:7/18/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers, FL 33913 Load Tables for the: 1"x3-1/8" Heavy Aluminum Mullion, Horiz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION: 1"x 3-1/8" (HEAVY)-ONE-WAY MULLIONS SPAN V TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 191.4 176.7 167.5 162.2 161.6 159.4 72 200.0 154.5 126.8 109.1 97.1 88.9 84.0 83.3 79.7 84 126.2 96.1 78.4 66.8 58.9 53.2 49.6 49.1 46.1 96 84.2 63.9 51.8 44.0 38.5 34.5 31.9 31.5 29.3 108 58.9 44.6 36.1 1 30.5 26.6 23.7 21.8 21.5 19.9 DESIGN PRESSURE LIMITS FOR MULLION: 1"x 3-1/8" (HEAVY)-TWO-WAY MULLIONS SPAN V TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 191.4 167.5 151.3 148.9 134.0 48 200.0 200.0 200.0 167.5 143.6 125.6 113.5 111.7 100.5 60 200.0 200.0 160.8 134.0 114.9 100.5 90.8 89.3 80.4 72 196.8 147.6 118.1 98.4 84.4 73.8 66.7 65.6 59.1 84 124.0 93.0 74.4 62.0 53.1 46.5 42.0 41.3 37.2 96 83.0 62.3 49.8 41.5 35.6 31.1 28.1 27.7 24.9 108 58.3 43.7 35.0 29.2 1 25.0 1 21.9 19.8 19.4 17.5 Impact Ratings ASTM E1996-Wind Zone 4, Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant Keystone Certifications, Inc. 564 Old York Road,Suite 5 Etters, PA 17319 Phone;717.932.8500 www.keystonecerts.com Document Title: Doc No: FRM B1-02 r� Structural Performance Rev No: 7 Page: 1 of. 1 K�YSATI OTOIti[ Certification CEiQTIPICNB.1 NG. Authorization Report Required By: PRO B1-03 CAR & Product ID Number: 622 - 103.0 Issue Date: 1/16/2015 Revision Date: 4/1/2015 Expiration Date: 7/18/2018 Company Code: 622 This Certification Authorization Report(CAR) is issued by Keystone Certifications, Inc. (KCI)after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. Licensee Information: Product Information: Eastern Architectural Systems Model Name.___ ___1"x4 Alul� nu ,Mull on, '4' ; , 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Configuration: No Reinforcement Max. Width: See Table Max. Height: See Table Referenced Standard: Product Rating: AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-3010W-8A/9A Test Report Expiration: 7/18/2018 Authorized Signature: Keystone Certifications, Inc. Digitally signed by Steven M.Urich 564 Old York Road, Suite 5 DN:cn=Steven M.Urich,o=Keystone Etters, Pennsylvania 17319 Certifications,Inc.,ou, Phone: 717-932-8500 email=surich@keystonecerts.com, -c--US' Fax: 717-932-8501 Date:2015.04.01 11:02:39-04'00' W WAV.KEYSTONECERTS.COM KAY ONc, Appendix 1 CAR No:622-103.0 C6RTIFICATON6.INC. Expiration Date:7/18/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers, FL 33913 Load Tables for the: ff- 1"x4"Aluminum-Mullion,H --iz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION: 1" x 4" -ONE-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 72 200.0 200.0 200.0 181.5 161.6 147.9 139.7 138.6 132.6 84 200.0 159.9 130.4 111.2 98.0 88.5 82.5 81.7 76.7 96 140.1 106.3 1 86.3 1 73.2 1 64.1 57.4 1 53.1 1 52.5 48.8 108 98.1 1 74.2 1 60.1 1 50.8 1 44.3 1 39.5 1 36.3 1 35.9 33.1 DESIGN PRESSURE LIMITS FOR MULLION: 1"x 4" -TWO-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 198.5 48 200.0 200.0 200.0 200.0 200.0 186.1 168.1 165.4 148.8 60 200.0 200.0 200.0 198.5 170.1 148.8 134.5 132.3 119.1 72 200.0 200.0 196.6 163.8 140.4 122.9 111.0 109.2 98.3 84 200.0 154.7 123.8 103.2 88.4 77.4 69.9 68.8 61.9 96 138.2 103.7 82.9 69.1 59.2 51.8 46.8 46.1 41.5 108 97.1 72.8 1 58.2 1 48.5 41.6 36.4 1 32.9 32.4 29.1 Impact Ratings ASTM E1996-Wind Zone 4, Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant Keystone Certifications, Inc. 564 Old York Road,Suite 5 Etters, PA 17319 Phone:717.932.8500 www.keystonecerts.com Docunent Title: Doc No: FRM 131-02 V— �� 7 Structural Performance Rev No: Pace: 1 Of:1 1 ikEYSTONk, Certification CCIxrIPICATON9.INC. Authorization Report Required By: PRO B1-03 CAR & Product ID Number: 622 - 105.0 Issue Date: 2/11/2015 Revision Date: 4/1/2015 Expiration Date: 7/18/2018 Company Code: 622 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. Licensee Information: Product Information: Eastern Architectural Systems Model: 2°x4"Aluminum Mullion HN/T/X 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Config: No Reinforcement Max Width: See Table Max Height: See Table Referenced Standard: Product Rating: AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-3010W-8A/9A Test Report Expiration: 7/18/2018 Authorized Signature: Digitally signed by Steven M.Urich Keystone Certifications, Inc. DN:cn=Steven M.Urich,o=Keystone 564 Old York Road, Suite 5 :,Certifications,Inc.,OU, Etters, Pennsylvania 17319 email=surich@keystonecerts.com, c=us Phone: 717-932-8500 r' Date:2015.04.01 11:06:34-04'00' Fax: 717-932-8501 W W W.KEYSTONECERTS.COM K YSTOiti[ ', Appendix 1 CAR No:622-105.0 cERr"'�"''o^'B•'^'�• Expiration Date:7/18/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers, FL 33913 Load Tables for the: 2"x4" Aluminum Mullion, Horiz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION: 2"x 4"-ONE-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 1 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 72 200.0 200.0 200.0 200.0 200.0 197.0 188.0 186.8 180.1 84 200.0 200.0 195.1 166.4 146.6 132.5 123.5 122.2 114.8 96 200.0 159.0 1 129.1 109.5 95.9 85.9 79.5 78.5 73.0 108 146.7 111.1 1 89.9 1 76.0 1 66.2 1 59.1 1 54.4 1 53.7 49.5 DESIGN PRESSURE LIMITS FOR MULLION: 2"x 4"-TWO-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 1 24 30 36 42 1 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 197.0 178.0 175.1 157.6 60 200.0 200.0 200.0 200.0 180.1 157.6 142.4 140.1 126.1 72 200.0 200.0 200.0 175.1 150.1 131.3 118.7 116.7 105.1 84 200.0 200.0 180.1 150.1 128.7 112.6 101.7 100.1 90.1 96 200.0 155.1 124.1 103.4 88.6 77.6 70.1 68.9 62.0 108 145.2 108.9 87.1 72.6 62.2 54.5 1 49.2 1 48.4 1 43.6 Impact Ratings ASTM E1996-Wind Zone 4, Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant Keystone Certifications,Inc. 564 Old York Road,Suite 5 Etters, PA 17319 Phone:717.932.8500 www.keystonecerts.com Doument Title: Doc No: FRM 131.02 -7 Structural Performance Rev No: 7 Page: 1 of: 1 KEYSTONkl Certification CERTIF,CATIONB.INC. U Authorization Report Required By: PRO B1-03 CAR & Product ID Number: 622 - 106.0 Issue Date: 2/11/2015 Revision Date: 4/1/2015 Expiration Date: 7/18/2018 Company Code: 622 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone. Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. Licensee Information: Product Information: Eastern Architectural Systems Model: 2"x6"Aluminum Mullion HN/T/X 10030 Bavaria Road Operator Type: Mull Fort Myers FL 33913 Config: No Reinforcement Max Width: See Table Max Height: See Table Referenced Standard: Product Rating: AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-3010W-8A/9A Test Report Expiration: 7/18/2018 Authorized Signature: Digitally signed by Steven M.Urich Keystone Certifications, Inc. DN:cn=Steven M.Urich,o=Keystone 564 Old York Road, Suite 5 Certifications,Inc.,ou, Etters, Pennsylvania 17319 email=surich@keystonecerts.com, Phone: 717-932-8500 c=US' Date:2015.04.01 11:26:48-04'00' Fax: 717-932-8501 WWW.KEYSTONECERTS.COM 11'EY ONS'! Appendix 1 CAR No:622-106.0 {CHRTIFCATIONB.INC.¢ Expiration Date:7/18/2018 5�am.v�mm�w3 Eastern Architectural Systems 10030 Bavaria Road Fort Myers, FL 33913 Load Tables for the: 2"x6" Aluminum Mullion, Horiz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION: 2"x 6"-ONE-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 72 200.0 200.0 200.0 200.0 200.0 197.0 188.0 186.8 180.1 84 200.0 200.0 200.0 191.0 171.5 157.6 148.7 147.5 140.1 96 200.0 200.0 186.8 161.6 144.1 131.3 123.0 121.8 114.6 108 200.0 197.0 162.7 140.1 124.2 112.6 104.9 103.8 97.0 DESIGN PRESSURE LIMITS FOR MULLION: 2"x 6"-TWO-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 197.0 178.0 175.1 157.6 60 200.0 200.0 200.0 200.0 180.1 157.6 142.4 140.1 126.1 72 200.0 200.0 200.0 175.1 150.1 131.3 118.7 116.7 105.1 84 200.0 200.0 180.1 150.1 128.7 112.6 101.7 100.1 90.1 96 200.0 197.0 157.6 131.3 112.6 98.5 89.0 87.6 78.8 108 1 200.0 175.1 1 140.1 116.7 1 100.1 1 87.6 79.1 1 77.8 70.0 Impact Ratings ASTM E1996-Wind Zone 4, Missile Level D PA/TAS 201/203-Large Missile and Small Missile compliant Keystone Certifications, Inc. 564 Old York Road,Suite 5 Etters, PA 17319 Phone:717.932.8500 www.keystonecerts.com EASTERN ARCHITECTURAL SYSTEMS HVHZ CLIPPED ALUMINUM TU NZONS GENERAL NOTES: �'Wl' 4 WZ r'WI'—r'W2'1 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE 2010&5th EDITION I/ FLORIDA BUILDING CODE,INCLUDING THE HIGH VELOCITY HURRICANE ZONE. 3. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FORTHIS PRODUCT IN WIND BORNE DEBRIS REGIONS. MULL INDIVIDUAL UNITS ATTCHED TO MULLIONS MUST BE IMPACT RATED. �\\ / / SPAN'L' 4. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY AND 2X FRAMING AS A MAIN WIND FORCE NCHOR CLIP, RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE TYP %/ % / / FOUNDATION 15 THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF / INSTALLATION. V 1 TICAL SPAN S. 1X AND 2X BUC KS(WH E N US ED)SHALL BE DESIG N ED AN D ANC HORED TO PROP ERLY TRANS FE R ALL LOADS TO VERTICAL MULL STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF R CORD 4 SPAN'L' MULSPAN LL' FOR THE PROJ ECT OF INSTALLATION. MULLION 6. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS F RA TYP SPECIFIC SITE.IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED EREIN, 'W2' A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DO,'- MENT IN NON-HVHZAREAS.IN HVHZ AREAS,ONE TIME PRODUCT APPROVAL TO BE OBTAINED FROM MIAMI-DADI.P RA. / 7. MULLION&CLIP MATERIAL:ALUMINUM 6005-TS&6063-T6(AS NOTED) 8. MULLIONS MAY BE USED WITH ANY APPROVED FENESTRATION PRODUCT,UNDER SEPARATE APPROVAL. / Wl 9. SEE SHEETS 5-9 FOR INSTALLATION ANCHOR REQUIREMENTS FOR SPECIFIC ANCHORING REQUIREMENTS,M ION CONFIGURATIONS,AND DESIGN LOAD CAPACITIES. ANCHOR CLIP, A 10. IN ACCORDANCE WITH THE 2010&5TH EDITION FBC,DISSIMILAR METALS INCLUDING FASTENERS THAT MAY CO TYP 4 INTO CONTACT WITH ALUMINUM UNIT FRAMING SHALL BE PROTECTED AS DEFINED IN SEC 2003.8.4. TYPICAL MULLION ASSEMBLY HORIZONTAL"T" MULL SPAN MULL INSTRUCTIONS: SPAN'L'r 1. ETERMINE REQ-MI IMDESIG� RE FD PENI G. / 2. CHOOS AMULUOUMAAT-PP-ROPERLY'FITS HE FENESTRATION PRODUCT. 'W2' TABLE OF CONTENTS 3. DETERMINE WHETHER ASSEMBLY REQUIRES ONE-WAY OR TWO-WAY MULLIONS: / • ASS EM BLIES CONSISTING OF STACKED OR SI DE-BY-SIDE UN ITS REQUIRE USE OF SHEET REVISION SHEET DESCRIPTION ONE-WAY MULLIONS. / • ASSEMBLIES CONSISTING OF MULTIPLE UNITS MULLED TOGETHER WITH MULTIPLE MULLIONS REQUIRE USE OF TWO-WAY MULLIONS. ] - GENERAL NOTES,INSTRUCTIONS,AND ELEVATIONS • SEE SHEET 11 FOR ASSEMBLY AND LOAD EXAMPLES. / Wl' 2 - MULLION DETAILS • IF ASSEMBLY TYPE CANNOT BE DETERMINED USE TWO-WAY MULLION CHART. 4. VERIFY THAT MULLION DESIGN PRESSURE MEETS OR EXCEEDS REQUIRED DESIGN 3 - ANCHOR CLIP DETAILS PRESSURE OF OPENING USING CHARTS ON SHEETS 6-10. / 4 - MULLION SECTIONS S. QUALIFIED CLIP TYPES APPEAR ON SHEETS 6-10.MULTIPLE ANCHOR TYPE/SUBSTRATE/CUP COMBINATIONS WITHIN AN OPENING ARE ALLOWED. 5 - TYPICAL MULLION&CLIP A55EMBLIES 6. THE LESSER DESIGN PRESSURE OR MULLION OR FENESTRATION PRODUCT WILL HORIZONTAL SPAN GOVERN OVERALL ASSEMBLY DESIGN PRESSURE RATING. 6 - V X 3-1/8"(LIGHT)MULLION DESIGN LOAD TABLES 7 - 1"X 3-1/8"(HEAVY)MULLION DESIGN LOAD TABLES 8 - V X 4"MULLION DESIGN LOAD TABLES `IIII111111REVISIONS EABTERN aacRrtEcruRAL srsrENs 9 - 2"X 4"MULLION DESIGN LOAD TABLES F. /// : Eastern eAsiE NMseuSr y 30 - 2°X 6"MULLION DESIGN LOAD TABLES �`�lv�••;•• ;�.P'�� „ r�o" oo.-_-eeoa RF�.MT- m K � MULLION ASSEMBLY AND LOAD EXAMPLES �'•• Z ' HVHZ CLIPPED ALUMINUM TUBE MULLIONS * = VERTICAL AND HORIZONTAL CONFIGURATIONS v T T r = GENERAL AND INSTALLATION NOTES DAM'ORAWNft. PREPAREDew. Digitally signed by Hermes F.Norero,P.E. : o� [ oP. �� oz 05/13 TJH Reason:I am approving this document /,`�pQ �'Nq�Rpa�'���`� DRAMONQ 5� FBDVEING DROPS.CERTMCATEOF Jlpd��7��3J p(11�YiB % PA-0003 N.T.S. ® AUTHOWATION NO.29578 Date:2015.02.28 12:45:10-05100' FSE DAN ABFACR BLVD Z BY I ESCRIPTION REV 5 t GF 11 REV: -+{ 2.000" 0.250" -� �- 1.000" � 2.000" �-- �-- 1.000" --� �-- 1.000" 0.250" 0.250" 6.000" 0.125 0.125 4.000" 4.000" 3.125" 3.125" -1 d j j 0.375" 0.625" 50" 0.250" 0.250" 1"X 3-1/8"(LIGHT) 1"X 3-1/8"(HEAVY) 1"X 4" 2"X 4" 2"X 6" MULLION MULLION MULLION MULLION MULLION SEE SHEET 6 FOR SEE SHEET 7 FOR SEE SHEET s`FOR SEE SHEET 9 FOR SEE SHEET 10 FOR QUALIFIED CLIPS QUALIFIED CLIPS Q0ALIFYEO CLIeS QUALIFIED CLIPS QUALIFIED CLIPS �"mo NOTE:SEE SHEET 3 FOR SPECIFIC CLIP TYPES AND DIMENSIONS. ```���Illllllff�ff'' REVISIONS ���� TE�MomsioNOF SYSiEM9 ES F. o Eastern E 91Ew NETA 3Y y �`/•C_�• ��,''� • �A��oM w..on A o o'oovo FORTMYEitS.FL°wDA 33913 7 = n u HVHZ CLIPPED ALUMINUM TUBE MULLIONS - * = VERTICAL AND HORIZONTAL CONFIGURATIONS fl T T r = MULLION CROSS SECTIONS S : <[/� onTe oruwN°v: vNErnNEo ev: OT 2��: . . . G� � DRAW NG NOS 3 P]�j TJH HORIIZATIONBUMDING NO.2939ePA-03 ® AUTHORIIATIONN0.29578 FBPE CEU..a NQ 29578 �4R� �4..� �511� �5 � 0 0 2.25" p 2.25" o �-o 0 l< 2.25" 1.75" 2.625" 3.375" 0 2.25" ° 0 225" 0 4.625" 5.375" 0 0 10.12 2" 0.125" 2" 0.125" 2' t—O 0 }T T—X 5" X 2 1/4" L-CLIP o.l2" X 5" X 13/4" L-CLIP 2.z5" 2" z�5 2" X 4" X 3 3/8" L-CLIP ALUMINUM 6063-T6 ALUMINUM 6063-T6 " -1 z ALUMINUM 6063-T6 2" X 4" X 5 3/8" L-CLIP 10.46" ALUMINUM 6063-T6 2.50" 0.722"- I� 2.25" 0 0 2.25" � � 0-1 � 0.722"--1 f —. 10.46" C/\ .(\ o 2.25' 2.25' 0 1.75" p 2.25" p ° 2.25" 2.335" 2 25" ° 0.188" o .25' o .25" 0 1.25" 2.125" 2.125" 0.188" T -T10 15/32" X 2 1/4" H-CLIP 2 1/4" U-CLIP 13/4" U-CLIP ALUMINUM 6063-T6 ALUMINUM 6005-T5 ALUMINUM 6005-T5 �� 1015/32�� X 13/4 H-CLIP ALUMINUM 6063-T6 8.25" 2.25"—t2.25" 2.25"— 0 0 0 0 2.625" ``llllllll/!/��' REVISIONS EASTERNARCHRECTURALSYSTEMS �- Eastern ADN�DNDF 0 0 0 0 �SES F. O ��� EA9TERN METAL SYPPLY .. un+.Hu o ooY� I0 BAVARIAROAD 0.125" I ♦ (4: .A i FORT MYERS,FLORIDA 33913 1y �Z: • • :/O y .. j 7 = n HVHZ CLIPPED ALUMINUM TUBE MULLIONS 0.875" _L * * _ VERTICAL AND HORIZONTAL CONFIGURATIONS zr_ CLIP DETAILS 11 11 ';. T T ' 1(f DATE:DRAWN BY: PREPARED BY: 81/4 X 3 3/8 H-CLIP ?o� 02/05/13 r�H ' DMWINONO: SCALE Y~ BVILDIN6 DRDP5,INC. ALUMINUM 6063-T6 �� OF r'AtiRE C� O PA-0003 N.T.S. �� FDPE CERTIFICATE OF ` AUTHORRATION NO.29578 398 EASEARN'fkN9��1[F�cEx ��o aeB7e By DATE DescRIPnDN �' BH3 OF 11 ' INSTALLATION INSTALLATION INSTALLATION ANCHOR(SEE NOTES 2 1/2"MIN. ANCHOR(SEE NOTES 11/2"MIN. ANCHOR(SEE NOTES HORIZONTAL SHEETS b-10) EDGE DIST. SHEETS 6-10) EMBEDMENT SHEETS 6-10) MULLION,TYP. CONCRETE OR e MASONRY BY OTHERS ° c• °'• CAULK BETWEEN ° a a. ° 11/4"MIN. 3/4"MIN. v v EXTERIOR MULLION CLIP CONCRETE/MASONRY G 1X G a .° EMBEDMENT EDGE DIST. o TYP. WOOD BUCK BY OTHERS U'CLIP c TYP. 1 X WOOD BUCK CONCRETE OR ° EXTERIOR INTERIOR BY OTHERS MASONRY BY OTHERS CAULK BETWEEN ° I I MULLION CLIP CONCRETE/MASONRY d 2X VERTICAL TYP. WOOD BUCK BY OTHERS v MULLION,TYP. I I I I 2X WOOD BUCK EXTERIOR I I INTERIOR BY OTHERSa. MULLION INTERIOR TYP. HORIZONTAL SECTION I MULLION TYP 4 T-MULLION INTERSECT DETAIL HORIZONTAL SECTION SIDE VIEW g VERTICAL SECTION 4 JAMB-ZX WOOD BUCK 4 HEAD-CONCRETE/MASONRY SIDE VIEW-HORIZONTAL SIDE VIEW-VERTICAL INSTALLATION ANCHOR(SEE NOTES SHEETS 6-10) HORIZONTAL MULLION,TYP. EXTERIOR i I INTERIOR MULLIONNOTE EXTERIOR INTERIOR TYP DETAILS SHOWN ARE TYPICAL FOR ® ® MULLION CLIP ALL MULLION A CLIP ASSEMBLIES. VERTICAL I I SEE SHEETS 6-10 FOR ALLOWABLE MULLION CONFIGURATIONS,SIZES, MULLION,TYP. I I MULLION CLIP AND DESIGN PRESSURES. I I TYP. HORIZONTAL SECTION A" :n °. X-MULLION INTERSECT DETAIL a dl ° ° SIDE VIEW 11/4"MIN. d, ° EMBEDMENT PRECAST SILL e ° %IUIIJJJJ REVISIONS _ EASTERNARCHRECURALSYSTEM BY OTHERS �����$F. O'ZZ��i� . EABTERNMSEOALSY—Y pI Eastern _ � � ' F J A��eM'w,uo..a�o o�owa BURT MYERS,FLORIDA3]91S INSTALLATION r x.` ANCHOR(SEE NOTES 2 1/2"MIN. 7 ?�_ ~ TRS HVHZ CLIPPED ALUMINUM TUBE MULLIONS SHEETS 6-10) EDGE DISTANCE _`* . ;* _ VERTICAL AND HORIZONTAL CONFIGURATIONS VERTICAL SECTION T T INSTALLATION DETAILS DATE DRAWN BY: PPEPMED BY: 02 O5 13 TJH 4 SILL-CONCRETE MASONRY Z CERTIFICATE INC. CONCRETE/ �I E4 C.NDIQJ20 �y �� DRAWING NO: SCALE: AUTFOPE HORIZATION NO.29578 SIDE VIEW-VERTICAL 798,,D 'L PA-0003 1 1 N.T.S. FUM DDa � a 2BSTe L.A� DescwvnoN REY SH4 OF 1 1 REv VERTICAL MULLION U—CLIP TO MULLION CONNECTION HORIZONTAL MULLION H—CLIP SUBSTRATE BY OTHERS SUBSTRATE VARIES, SEE NOTES SHEETS 6 — 10 H—CLIP ANCHORS ALL INSTALLATION HOLES MUST HAVE AN ANCHOR INSTALLED IN THEM MULLION AND CLIP ASSEMBLY TYPICAL ASSEMBLY SHOWN WITH V x 3 1/8"MULLION AND H-CLIP.OTHER MULLIONS AND CLIPS ARE APPROVED. SEE INDIVIDUAL MULLION SHEETS f l fo,f ' REVISIONS ��� EASTeA.to GF RYsreMs Eastern n o.V.NYL 19D30 BAVARIA ROAD \\\\��� • �/Q',�I v*e•� _ _ _ _ FORT MYERB,FLORIDA 33913 •�• • •O 999-03b9261 7 n E HVHZ CLIPPED ALUMINUM TUBE MULLIONS VERTICAL AND HORIZONTAL CONFIGURATIONS v • T T r = MULLIION AND CLIP ASSEMBLY DETAILS DATE:DRAYM BY: PREPARED BY: .c� ............ _ 02 OS 13 TJH �I G\ \\ DRAWINGNO: SCALE f AA BUILDING DROPS,INC. ���\ PA-0003 N.T.S. w1R AUTHOR ICZATTIIONANO.O.29576 798 338 FBPE CER-OF AU N0.2078 BY DATE OESORIP110N REV S S OF 1 1 • �I F� DESIGN PRESSURE LIMITS FOR MULLION: x 3-1/8"(LIGHT)-ONE-WAY MULLIONS 1.000"ONS I I MULLION MULLION SP N.) TRIBUTARY WIDTH'W(I48 I (IN.) 18 48 24 30 36 42 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 -200.0 200.0 200.0 0.125" 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 3.125" 60 200.0 200.0 1810 158.0 143.3 134.3 179.8 129.3 127.6 {- -11- 72 1616 123.7 101.5 87.3 77.7 71.1 67.2 66.7 63.8 84 101.0 76.9 62.7 53.5 47.1 42.6 39.7 39.3 36.9 96 67.4 511 415 351 30.8 27.6 25.6 25.2 23.5 ONE-WAY MULLION DIAGRAMS 108 47.2 35.7 28.9 24.4 21.3 19.0 17.5 17.2 15.9 0.375" DESIGN PRESSURE WITS FOR MULLION:1"x3-1/9' LIG -TWO-WAY MUWONS 1" X 3-1/8" (LIGHT) MULLION SPAN'L' TRIBUTARYWIDTH'w IN. ALUMINUM 6005-T5 MULLION (IN.) 18 24 30 36 42 48 53.125 54 60 MULLION 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 LE=Q] 36 200.0 200.0 200.0 '200.0 1914 167.5 151.3 148.9 134.0 48 200.0 200.0 200.0 167.5 143.6 125.6 113.5 1117 100.5 60 200.0 200.0 160.8 134.0 114.9 100.5 90.8 .89.3 80.4 W1+W2 72 157.6 118.2 94.5 78.8 67.5 59.1 53.4 52.5 47.3 TRIBUTARY WIDTH= 84 99.2 74.4 59.5 49.6 42-5 37.2 33.6 33.1 29.8 96 66.5 49.9 39.9 33.2 285 24.9 22.5 22.2 19.9 I II 108 46.7 35.0 280 23.3 20.0 17.5 15.8 15.6 14.0 TWO-WAY MULLION DIAGRAMS TABLE NOTES: 1. SEE SHEET I FOR INSTRUCTIONS ON USING TABLES.SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS&CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS I5 ALLOWED. QUALIFIED ANCHOR CLIPS 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CLIP DIMENSIONS. 5. ANCHOR REQUIREMENTS: •WOOD:#14 WOOD SCREWS •CMU:1/4"ITW TAPCONS 0 0 •CONCRETE:1/4"ITW TAPCONS ° •METAL:1/4"SELF-DRILLING SCREWS(GRADE 5) 6. INSTALLATION SUBSTRATES: ° •WOOD ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/2"$EDGE DISTANCE OF V.WOOD SHALL BE MIN.5.G.=0.55. o ° 0 ° •HOLLOW CMU ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/4"d EDGE DISTANCE OF 2-1/2".HOLLOW CMU SHALL 0 BE MEDIUM WEIGHT CONFORMING TO ASTM C 90. 2" X 5" X 2 1/4" L-CLIP •CONCRETE ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-3/4"d EDGE DISTANCE OF 2-1/2".CONCRETE SHALL BE 2 1/4" U-CLIP ALUMINUM 6063-T6 MIN.4000 PSI. ALUMINUM 6005-Tb **MUST BE USED IN PAIRS •METAL ANCHORS SHALL HAVE A MIN.(3)THREADS PENETRATION BEYOND METAL STRUCTURE.STEEL SHALL BE MIN. 18 GA.(0.045"THICK)33 KSI YIELD.ALUMINUM SHALL BE MIN.1/8"THICK ALUMINUM 6063-T3. U-CLIP FOR USE ONLY IN MULLION-TO-MULLION CONNECTIONS ``��� L I I �7A7j REVISIONS �P EASTERN ARORREc uRAL sysTEL s ` Eastern AOM810N OF 0 0 0 `�� SES F• Q ��i ■ EASTERN 11lErAL svcFLT /,_• tOatOBAVMI O oo�"e n..-000-n FORT LITERSFL ,FLORIRI DA 3]91] -.K-i%'' w�.. n 800432-12M NOTE:SEE SHEET FOR SPECIFIC o 0 0 _ 7 ' E HVHZ CLIPPED ALUMINUM TUBE MULLIONS CLIP TYPES AND DIMENSIONS. * 3 * VERTICAL AND HORIZONTAL CONFIGURATIONS 1015/32" X 2 1/4" H-CLIP = T T 1" x 3 1/8" LI HT MULLION ALUMINUM 6063-T6 ���A p.' OATS DRATm er. RRErARED aw. c.n_ �G� `� oaA-ON05 13 3�TJH , FIDPECE DROPS, !'n�jb�TDW/�Bs°yj�ie PA-0003 N.T.S. AUTHORuwnONNO.Z9sre 39E EA9TANA t Ml53DM er OATS DESCRIPTION REV sHEEf: REy: FSE CERT.OF A OR1 WN Na 29578 6 OF 11 DESIGN PRESSURE LIMITS FOR MULLION:1"x3-1/8"(HEAVY)-ONE-WAY MULLIONS MULLION SPAN'L' TRI BUTARY WIDTH'W'(I N.) 1.000" MULLION (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 -200.0 200.0 200.0 200.0 0.125" 60 200.0 200.0 200.0 191.4 176.7 167.5 162.2 161.6 159.4 72. 200.0 154.5 126.8 109.1 97.1 88.9 - 84.0 83.3 79.7 3.125" I ^ II o -84 126.2 96.1 76.4. 66.8 58.9 53.2 49.6 49.1 46.1 96 84.2 . 639 51.8 44.0 38.5 34.5 31.9 31.5 29.3 ONE-WAY MULLION DIAGRAMS 108 58.9 44.6 . 36.1 30.5 26.6 23.7 - 21.8 21.5 '19.9 DESIGN PRESSURE UMITS FOR MULLION:Y"x 3-1/8"(HEAVY)-TWO-WAY MULLIONS 0.625" SPANT TRIBUTARY WIDTH"W' IN. 111 X 3-1/811 (HEAVY) MULLION--� (IN.) 18 24 30 36 42 48 53.125 54 00 MULLION 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 ALUMINUM 6005-T5 MULLION 36 200.0 200.0 200.0 200.0 19L4 167.5 151.3 148.9 134.0 48 200.0 200.0 200.0 167.5 143.6 125.6 113.5 111.7 100.5 60 200.0- 200.0 160.8 134.0 114.9 100.5 90-8 89.3 80.4 72- 196.8 147.6 118.1 98.4 84.4 73.8 66.7 65.6 59.1 W1+W2 84 124.0 93.0 74.4 62.0 53.1 46.5 42.0 41.3 37.2 TRIBUTARY WIDTH- 2 96 83.0 62.3 49.8 41.5 35.6 3,1 28.1 27.7 24.9 108 583 43.7 3E. 29.2 25.0 21.9 19.8 19.4 17.5 TWO-WAY MULLION DIAGRAMS TABLE NOTES: 1. SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES.SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS,&CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. QUALIFIED ANCHOR CLIPS 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CLIP DIMENSIONS. 0 5. ANCHOR REQUIREMENTS: o •WOOD;#14 WOOD SCREWS •CMU:1/4"ITW TAPCONS 0 •CONCRETE:1/4"ITW TAPCONS •METAL:1/4"5ELF-DRILLING SCREWS(GRADE 5) 13/411 U-CLIPo 0 6. INSTALLATION SUBSTRATES: ALUMINUM 6005-T5 •WOOD ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/2"&EDGE DISTANCE OF V.WOOD SHALL BE MIN.S.G:0.55. •HOLLOW CMU ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/4"A EDGE DISTANCE OF 2-1/2".HOLLOW CMU SHALL 0 o 0 o BE MEDIUM WEIGHT CONFORMING TO ASTM C 90- U-CLIP FOR USE ONLY IN •CONCRETE ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-3/4"&EDGE DISTANCE OF 2-1/2".CONCRETE SHALL BE MULLION-TO-MULLION 211 X 511 X 13/4" L-CLIP MIN.4000 PSI. CONNECTIONS •METAL ANCHORS SHALL HAVE A MIN.(3)THREADS PENETRATION BEYOND METAL STRUCTURE.STEEL SHALL BE MIN. ALUMINUM 6063-T6 18 GA.(0.045"THICK)33 KSI YIELD.ALUMINUM SHALL BE MIN.1/8"THICK ALUMINUM 6063-T5. ""MUST BE USED IN PAIRS `\1111111/I/// REVISIONS _ _ FAS-RIARCHDECRIHAL61-S �`` // '• Eastern AONISION OF ES F. O /// (I EAST ADWISIALSYPPLY O O O \\\\���•••• ���''�� 4 Amu w�INuw�Awo Vlwvl_ 10030 BAVARNROAD ` •. •• •• 0 •d'nn.v.w...vawv....v ovowa 800432-2XkS,FLORIDA 33813 NOTE:SEE SHEET FOR SPECIFIC 7 = HVHZ CLIPPED ALUMINUM TUBE MULLIONS CLIP TYPES AND DIMENSIONS. 0 0 0 `* . ;* _ VERTICAL AND HORIZONTAL CONFIGURATIONS a T T r = 1" x 3 1/8" HEAVY MULLION 11 /1 i M '• • �I \ - DATE:DRAWN DY: PREPARED BY: 1015/32 X 13/4 H-CLIP . . c e:��.41 oz os 13 TJH ALUMINUM 6063-T6 •55..N G�\\� DRAWING NO: SCA E POPE DcERTIFIinreo /R1pUSK RJ91 \�` PA-0003 N.T.S. ® AUTHORIZATION NO.29578 398 EAST�Rfli 9EAC SY Rte: PT3PE CQ2T.ADCC [(AUTON N0.29578 I OATS DESCRIPf10N REV SR 7'OF 11 MULLION DESIGN PRESSURE UMITS FOR MULLION:1"x4"-ONE-WAY MULLIONS 1.000" MULLION SPAN'L' TRIBUTARY WIDTH'W'(IN.)_ _.(IN.) 18 24 30 36 42 48 53.1251 54 60 24 200.0 1 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 0.250" 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 ^ I I q I 72 .200.0 200.0 200.0 181.5 161.6 147.9 139.7 138.6 132.6 4.000" 84 200.0 159.9 130.4 111.2' 98.0 88.5 82.5 81.7 76.7 96 140.1 106.3 86.3 73.2 .64.1 57.4 53.1 52.5 48.8 ONE-WAY MULLION DIAGRAMS 108 98.1 14.2 60.1 50.8 44.3 39.5 36.3 35.9 33.1 DESIGN PRESSURE UMITS.FOR MUWON:1"x4"-TWO-WAY MULLIONS I •� SPANT TRIBUTARY WIDTH'W(IN.) MULLION (IN. 18 24 30 36 42 48 53.125 54 60 0'25 _ MULLION 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 1`° X 4" MULLION A 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 198.5 -""'>";�ALUMll M'60005aT5 - 48 200.0 200.0 200.0 200.0 200.0 186.1 -168.1 165.4 148.8 - ,�._'-, - 60 200.0 200.0 -200.0 198.5 170.1 148.8 134.5 132.3 119.1 72 200.0 200.0 196.6 163.8 140.4 122.9 111.0 109.2 98.3 84 200.0 154.7 123.8 103.2 88.4 77.4 69.9 68.8 61.9 TRIBUTARY WIDTH= Wl-W2 96 138.2 103.7 82.9 69.1 59.2 51.8 46.8 46.1 4L5 2 -�I - 108 97.1 72.8 58.2 48.5 41.6 36.4 TWO-WAY MULLION DIAGRAMS TABLE NOTES: 1. SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES.SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS G CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CLIP DIMENSIONS. 5. ANCHOR REQUIREMENTS: •WOOD:#14 WOOD SCREWS •CMU:1/4"ITW TAPCONS QUALIFIED ANCHOR CLIPS •CONCRETE:1/4"ITWTAPCONS •METAL:1/4"SELF-DRILLING SCREWS(GRADE 5) 6. INSTALLATION SUBSTRATES: •WOOD ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/2"6 EDGE DISTANCE OF 1".WOOD SHALL BE MIN.S.G:0.55. •HOLLOW CMU ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/4"&EDGE DISTANCE OF 2-1/2".HOLLOW CMU SHALL o o o o BE MEDIUM WEIGHT CONFORMING TO ASTM C 90. 0 O o o •CONCRETE ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-3/4"6 EDGE DISTANCE OF 2-1/2".CONCRETE SHALL BE MIN.4000 PSI. •METAL ANCHORS SHALL HAVE A MIN.(3)THREADS PENETRATION BEYOND METAL STRUCTURE.STEEL SHALL BE MIN. 18 GA.(0.045"THICK)33 KSI YIELD.ALUMINUM SHALL BE MIN.1/8'THICK ALUMINUM 6063-T5. 0 0 0 o tt 11 tt O O O O ``,``,S. rtrr'i���i REVISIONS _spa eAs*ERN AOMIOc`uRA�m,m+s 2 X 4 X 3 3/8 L-CLIP g 1/4" X 3 3/8" H-CLIP �sE o Eastern EA9TERNNETALBYPP�r ALUMINUM 6063-T6 ALUMINUM 6063-T6 `�/e F'RieAMyi �"FLoM=13 ""MUST BE USED IN PAIRS r �0 x-..` B9aa32-aoa 7 = T HVHZ CLIPPED ALUMINUM TUBE MULLIONS e k = VERTICAL AND HORIZONTAL CONFIGURATIONS D: 1" x 4" MULLION NOTE:SEE SHEET FOR SPECIFIC r � ` DATE:Ow.wn sr: ERevAREO er. �t� '• 11 CLIP TYPES AND DIMENSIONS. ' _4 02/05 13 TJH �i cc ..............�j� �� RA9ANa xo swE BUILDINBDRO 'lw. O FBPE CERTIF2CATE OF ase �s3e PA-0003 N.T.S. �� AU THORRAnONN0.29578 s" FBPEa 28s78 ar DATE DEBCRIPnON REv 8 O 11 REv- DESIGN PRESSURE LIMITS FOR MULLION:2'x4"-ONE-WAY MULLIONS MULLION SPAN'L' - TRIBUTARY WIDTH'W(IN.) (IN. 1S 24 30 36 42. 48 53.125 54 60 2 0� I~ MULLION 24 200.0 200.0 200.0 200.0 -200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0- 200.0 200.0 200.0- 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.6 200.0 0.250" 72 -200.0 200.0 200.0 200.0 200.0 197.0 188.0 186.8 84 200.0 200.0 195.1 166.4 146.6 132.5 123.5 122.2 114.8 96 200.0 159.0 129.1 109.5 95.9 85.9 79.5 78.5 73.0 4.000" 108 146.7 111.1 89.9 76.0 66.2 59.1 54.4 53.7 49.5 ONE-WAY MULLION DIAGRAMS DESIGN PRESSURE UMITS FOR MULLION:2"x 4"-TWO-WAY MULLIONS SPAN T TRIBUTARY WIDTH'W'(IN. (IN.) 18 24 30 36 42 48 53.125 1 54 60 MULLION 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 0.250" MULLION 36 200.0 200.0 200.0 200.0 200.0 -200.0200.0 200.0 200.0 2" X 4"MULLION 48 200.0 -200.0 200.0 200.0 200.0 197.0 178.0 175.1 157.6 60 200.0 200.0 200.0 200.0 180.1 157.6 142.4 140.1 126,1 ALUMINUM 6005-T5 72 200.0 200.0 -200.0 175.1 750.1 131.3 118.7 116.7 105.1 84 200.0 200.0 - 180.1 150.1- 128.7 112.6 101.7 100.1 90.1 96 200.0 155.1 124.1 103.4 88.6 77.6 - 70.1 68.9 62.0 W1,W2 108 145.2 108.9 87.1 72.6 62.2 54.5 49.2 48.4 43.6 TRIBUTARY WIDTH= 2 I n I I v I TWO-WAY MULLION DIIA-GR-IAI-MS-I TABLE NOTES: 1. SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES.SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS&CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS I5 ALLOWED. 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CLIP DIMENSIONS. 5. ANCHOR REQUIREMENTS: QUALIFIED ANCHOR CLIPS •WOOD:#14 WOOD SCREWS •CMU:1/4"ITW TAPCONS •CONCRETE:1/4"ITW TAPCONS •METAL:1/4"SELF-DRILLING SCREWS(GRADE 5) 6. INSTALLATION SUBSTRATES: 0 0 0 0 •WOOD ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/2"&EDGE DISTANCE OF V.WOOD SHALL BE MIN.S.G:0.55. •HOLLOW CMU ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/4"&EDGE DISTANCE OF 2-1/2".HOLLOW CMU SHALL BE MEDIUM WEIGHT CONFORMING TO A5TM C 90. •CONCRETE ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-3/4"&EDGE DISTANCE OF 2-1/2".CONCRETE SHALL BE MIN.4000 PSI. •METAL ANCHORS SHALL HAVE A MIN.(3)THREADS PENETRATION BEYOND METAL STRUCTURE.STEEL SHALL BE MIN. 0 0 0 0 18 GA.(0.045"THICK)33 KSI YIELD.ALUMINUM SHALL BE MIN.1/8"THICK ALUMINUM 6063-T5. 2" X 4" X 3 3/8" L-CLIP ALUMINUM 6063-T6 `��� �i�� REVISIONS ��►� EASTER" ADMSIONOF 3 **MUST BE USED IN PAIRS `�J��rGS F. 0 � Eastern EA9TERNMETAL9YPPLT "ROAD ROAD FORT RS,FLORIDA 33913 • -O 7 TDE HVHZ CLIPPED ALUMINUM TUBE MULLIONS NOTE:SEE SHEET 3 FOR SPECIFIC -* ' * = VERTICAL AND HORIZONTAL CONFIGURATIONS v . T T i G = 2" x 4" MULLION CLIP TYPES AND DIMENSIONS. A =• DATE:DRAWN BY: PREPARED BY: OT•., ( P;'�<U`� LMW 5 13 TJH \ BumbulG DROPS,INC. G`�\ SCALE FBPE CERTIFICATE OF 393 EA51"QpyA •••• ,333 003 N.T.S. ,I'Q AUTHORRATION N0.295]8 FBPE cFRDa oN Na 295Ta By ogre DEscRiRnoN 11 REv. DESIGN PRESSURE LIMITS FOR MULLION:2"z 6"-ON E-WAY MULLIONS 2.000" MULLION SPAN'L' TR13UTARYWIDTH'W(IN.) MULLION (IN.) is 24 30 36 42 48 53.125 54 . 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 0.250" 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 I II I- 72 200.0 200.0 200.0 200.0 200.0 197.0 188.0 186.8 180.1 I-•,-II-o-I 84 200.0 200.0 200.0 191.0 171.5 157.6 148.7 147.5 140.1 % 200.0 200.0 186.8 161.6 144.1 13L3 123.0 121.8 114.6 ONE-WAY MULLION DIAGRAMS 108 200.0 197.0 162.7 140.1 124.2 1 112.6 1 104.9 103.8 97.0 6.000" DESIGN PRESSURE LIMITS FOR MUWON:2"x 6"-TWO-WAY MULLIONS MULLION SPANT' TRIBUTARYWIDTH'lM IN.) MULLION (IN.) 18 24 30 36 42 48 153.1251 54 60 LN 24 200.0 200.0 20D.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 2000 200.0 200.0 197.0 178.0 175.1 157.6 60 200.0 200.0 - 200.0 200.0 -180.1 157.6 142.4 140.1 126.1 72 200.0 200.0 200.0 175.1 150.1 131.3 118.7 116.7 105.1 0.250" 84 200.0 200.0 180.1 150.1 128.7 112.6 101.7 100.1 90.1 I_n_II v I % 200.0 197.0 L57.6 13L3 112.6 98.5 89.0 87.6 78.8 2" X 6"MULLION 108 200.0 175.1 140.1 116.7 100.1 87.6 79.1 77.8 70.0 ALUMINUM 6005-T5 TWO-WAY MULLION DIAGRAMS TRIBUTARY WIDTH= Wl+W2 2 TABLE NOTES: 1. SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES.SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS S CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. QUALIFIED ANCHOR CLIPS 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CLIP DIMENSIONS. S. ANCHOR REQUIREMENTS: •WOOD:#14 WOOD SCREWS •CMU:1/4"ITW TAPCONS o o 0 o •CONCRETE:1/4"ITW TAPCONS •METAL:1/4"SELF-DRILLING SCREWS(GRADE 5) 6. INSTALLATION SUBSTRATES: •WOOD ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/2"G EDGE DISTANCE OF P.WOOD SHALL BE MIN.5.G.=0.55. •HOLLOW CMU ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-1/4"6 EDGE DISTANCE OF 2-1/2".HOLLOW CMU SHALL BE MEDIUM WEIGHT CONFORMING TO ASTM C 90. •CONCRETE ANCHORS SHALL HAVE A MIN.EMBEDMENT OF 1-3/4"d EDGE DISTANCE OF 2-1/2".CONCRETE SHALL BE MIN.4000 PSI. •METAL ANCHORS SHALL HAVE A MIN.(3)THREADS PENETRATION BEYOND METAL STRUCTURE.STEEL SHALL BE MIN.18 GA.(0.045" THICK)33 KSI YIELD.ALUMINUM SHALL BE MIN.1/8'THICK ALUMINUM 6063-T5. o 0 0 0 2" X 4" X 5 3/8" L-CLIP REVISIONS EASTERN AAM SIONOF SYO EM9 Eastern AD'R DP ALUMINUM 6063-T6 F � ��i' romy EA.sTERN METu srvP�Y A LUMINo....ovunuRw \ IMUST BE USED IN PAIRS \ !p .P � ,„a „•O -rev 000.132 TN1 7 - = Tr HVHZ CLIPPED ALUMINUM TUBE MULLIONS VERTICAL AND HORIZONTAL CONFIGURATIONS NOTE:SEE SHEET 3 FOR SPECIFIC = fl -_ T T G 2" x 6" MULLION CLIP TYPES AND DIMENSIONS. ��O '.• ( pP;' <4� DATE Duvet er. PREPARED OY a _ 02/05 13 TJH SCALE FBPE UILDCER'DECATE OF WItJC. 380 AN/LCNyB NDA' % PA-0003 N.T.S. ®� AUTHORIZATION NO.2957e FTiPEOi'AU�Af95T8 BY DATE DESCRIPTION REV 01 0 OF 11 R EXAMPLES OF TWO-WAY MULLION ASSEMBLIES EXAMPLES OF ONE-WAY MULLION ASSEMBLIES MULL MULL SPAN'L' 'WI' � 'W2' � � SPAN'L' MULL T SPAN'L' 1 'Wl' W l' ' MULL W2' SPAN'L' 'W2' 'W2' FA FA FA / HORIZONTAL MULLION HORIZONTAL MULLION / TRANSOM OVER MULTIPLE UNITS MULTIPLE UNIT ASSEMBLY VERTICAL MULLION HORIZONTAL MULLION 'Wl' 'W2' _ MULL MULL SPAN'LSPAN'L' 1Wl.� i MULL SPAN'L' 'W2' 'W2' Z-7 L L VERTICAL MULLION HORIZONTAL MULLION HORIZONTAL MULLION HINGED DOOR W/5IDELITE \\\``n,,S111FF1REVISIONS Eastern STERN ARCHDIVIITECTURAL SYSTEMS G�S F. O/,''�i�' .- EAST RNEfANL S�YPPLY NOTES: \\\ Q\\ CC iii I-ROAD ROAD 1. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND CONFIGURATIONS NOT `. !v • .Q FORT MYERB,FLOR DA 3]9I] SPECIFICALLY SHOWN MAY BE EXTRAPOLATED FROM TH05E SHOWN. \ 7 _ nom` TVHVHZ CLIPPED ALUMINUM TUBE MULLIONS 2. IF THE LOADING TYPE CANNOT BE DETERMINED,USE TWO-WAY =* : "� _ VERTICAL AND HORIZONTAL CONFIGURATIONS ASSEMBLY CONFIGURATION VALUES. v T T MULLION ASSEMBLY AND LOAD EXAMPLES 3. FENESTRATION PRODUCTS SHALL BE ANCHORED AS APPROVED. ;lO OP: ` DATE DRAWN BY: PREPARED BY: 1� ,yC �_\� DRANNON05 13 8 TJH BUILDING DROPS,INC. �I F.�O�R�,�G \\ FSPE CERTIFICATE OF ' �b77••••••7sOe ��\ PA-0003 N.T.S. '®( AUTHORIZATION NO.29578 398 335 SHEET: REN FBPE OERT.OFA W.29578 BY DATE DEScm"oN REv _11 OF 11 ach Blvd. BUILDING DROPS 398 EastDaniaB Suite 3 8 Dania Beach, FL 33004 A Perfect Solution in Every Drop 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of Eastern Architectural Systems, Inc. HVHZ Clipped Aluminum Tube Mullions for Florida Product Approval FL# FL17472 Report leo. 3285 Florida Building Code 2010 & 5th Edition Per Rule 61G20-3 Method: 1 —A (Certification) Category: Windows Sub — Category: Mullions Product: HVHZ Clipped Aluminum Tube Mullions Material: Aluminum 6005-T5 & 6063-T6 Prepared For: Eastern Architectural Systems 10030 Bavaria Road Ft Myers, FI. 33913 1%J111ii1111� ��ES F. Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer#73778 - * 7 Date: 02/27/15 - -v T T -0 Contents: ��i ��•''••......•••'• �� �� Evaluation Report Pages 1—4 Digitally signed by Hermes F.Norero,P.E. Reason:I am approving this document Hermes F. Norero, P.E. Date:2015.02.28 12:40:59-05'00' Florida No. 73778 ./J/T6A\\ BUILDING DROPS FL#: FL17472 A Perfect Solution in Every Drop Date: 02/27/15Report No: 3285 Certificate of Authorization:29578 Manufacturer: Eastern Architectural Systems, Inc. Product Category: Windows Product Sub-Category: Mullions Compliance Method: State Product Approval Rule 61G20-3 Product Name: HVHZ Clipped Aluminum Tube Mullions Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for Eastern Architectural Systems, Inc. based on Rule Chapter No. 61620-3, Method 1a of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the 2010&5th Edition Florida Building Code. See Installation Instructions PA-0003,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the 2010& 5th Edition Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the 2010&51h Edition Florida Building Code and does not require an impact resistant covering. Individual window units must be impact rated where applicable. 4. Site conditions that deviate from the details of drawing PA-0003 require further engineering analysis by a licensed engineer or registered architect. 5. All configurations shown in installation instructions PA-0003 have been qualified as required by section 1715.5.5 of the 2010 FBC and section 1710.5.3 of the 5th Edition FBC. 6. See Installation Instructions PA-0003 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No.73778 Page 2 of 4 ./(/ BUILDING DROPS FL#: FL17472 A\\ Date: 02/27/15 AM A Perfect Solution in Every Drop Report No: 3285 Certificate of Authorization:29578 Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code and Rule 61G20-3 for manufacturing under a Certification Agency through Keystone Certifications, Inc. (FBC Organization M CER1523). Referenced Code Sections: 1. 1715.5.5 of the 2010 FBC 2. 1710.5.3 of the 5th Edition FBC Referenced Data: 1. Product Testing performed by: Certified Testing Laboratories (FBC Organization M TST1577) Report#: CTLA 301OW-4 Report Date:07/18/14 Report M CTLA 3010W-4A Report Date:07/18/14 Report M CTLA 301OW-5 Report Date:07/18/14 Report M CTLA 3010W-5A Report Date:07/18/14 Report M CTLA 301OW-6 Report Date:07/18/14 Report M CTLA 3010W-6A Report Date: 07/18/14 Report M CTLA 301OW-7 Report Date:07/18/14 Report M CTLA 3010W-7A Report Date:07/18/14 Report M CTLA 301OW-8 Report Date:07/18/14 Report M CTLA 3010W-8A Report Date:07/18/14 Report M CTLA 301OW-9 Report Date: 07/18/14 Report M CTLA 3010W-9A Report Date: 07/18/14 2. Certification Agency Keystone Certifications, Inc. (FBC Organization M CER1523) Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 BUILDING DROPS FL#: FL17472 AL A Perfect Solution in Every Drop Date: 02/27/15 Certificate of Authorization:29578 Report No: 3285 Installation: 1. Approved anchor types and substrates are as follows: A. For two by(2X)wood frame substrate, use#14 Wood Screw type wood frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood framing. B. For concrete or masonry substrate where one by(1X), non-structural,wood bucking is employed, use 1/4"diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete or masonry substrate where wood bucking is NOT employed, use 1/4" diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. D. For metal stud substrate, use 1/4" Grade 5 self-drilling screw type metal frame anchors of sufficient length to achieve a minimum three threads penetration beyond metal structure. Refer to Installation Instructions (PA-0003)for anchor locations, design load tables, and further details of the installation requirements. Design Pressure: See drawing PA-0003 for mullion desing pressure tables,mullion profiles,and installation details. Hermes F. Norero, P.E. Florida No.73778 Page 4 of 4