HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential J
PERMIT APPLICATION FOR: Plumbing III
�PROPOSEDIMPROVEMENT'LOCATION:
Address: 9421 BRIARCLIFF TRCE - PORT ST LUCIE, FL 34986
Legal Description: BRIARCLIFF AT PGA VILLAGE - LOT 16 (OR 2772-1036)
Property Tax ID q: 3322-801-0021-000-0 Lot No. 16
Site Plan Name: Block No.
Project Name:
Setbacks Front Back: Right Side: Left Side:
DETAILED DESCRIPTION OF WORK:
Replace Failed Electric Water Heater in Garage with New 50 Gallon Electric Water Heater
CONSTRUCTION INFORMATION:
CONTRACTOR:
Name Ernesto KEANEY
Name: Robert W. LUDLUM
wor to
a erorme un ert
is permit —c hecka
appy:
City: PORT ST LUCIE State: FL
Zip Code: 34984 Fax: 772-708-5499
Phone No. 772-871-9494
II��mIona
I_IHVAC
Gas Tank
❑Gas Piping
_Shutters
❑Windows/Doors
Electric
❑✓_Plumbing
❑Sprinklers
❑Generator
❑Roof
Total Sq. Ft of Construction:
SFt. of First Floor:
Cost of Construction:
$ 975.00
Utilities: Sewer 11 Septic
Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name Ernesto KEANEY
Name: Robert W. LUDLUM
Address: 9421 BRIARCLIFF TRCE
Company: BENJAMIN FRANKLIN PLUMBING
City: PORT ST LUCIE State: FL
Zip Code: 34986 Fax: We
Phone No. 772-708-5499
Address: 1631 SW SOUTH MACEDO BLVD
City: PORT ST LUCIE State: FL
Zip Code: 34984 Fax: 772-708-5499
Phone No. 772-871-9494
E -Mail: Na
Fill in fee simple Title Holder an next page ( if different
from the Owner listed above)
E -Mail: permits@benfranklinplumber.com
State or County License: CFC1426801
n vaiue or construcrion is ocouu or more, a ncwnueu Nonce or commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
FRONT
DESIGNER/ENGINEER:
Name:
Not Applicable
MORTGAGE COMPANY:
Name:
Not Applicable
Address:
MANGROVE
Address:
COUNTER
City:
Zip: Phone:
State:
City:
Zip: Phone:
State:
FEE SIMPLE TITLE HOLDER:
Name:
_ Not Applicable
BONDING COMPANY:
Name:
_Not Applicable
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie Counttyy makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws oran covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrenty, review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection if you intend to obtain financing, consult with lender or an attorney before
STATE OF FLORIDASE.. STATE OF FLORIDA
COUNTYOF COUNTY OF a
Theff�ogg���ing instrument was acknowledged before me
thisa qday of C1426:!A 20 (fsby
(Name of person acknowledging I
11
(Signature of Notary Publiti lhate,fJlorlda I
Personally Known _" OR Produced Identification
Type of Identification Prod d
,p✓'°' ;. ONDA I tFcERT
Commission No. E M1(9Ba{tM15'oi --LJ4s
aark.,; EXPIRES January 0E, 201
Revised 07/15/2014
The forgoing instru ent was acknowledged before me
this4l& Day of , 20 L.J. by
(Name of person acknowledging I
&mdf
(Signature of Notary PubiU State q
Florida )
Personally Known c- OR Produced Identification
Type of Identification Produced
No. y "y,- RHRW LAFFERTY
}µI ,_j lay COMMISSICN': ud,,5237
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEATURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
Ce Smith. Residential Electric
Water Heaters
ENHANCED HEATING ELEMENTS
• Dual 4500 watt elements for fast recovery
and reliable operation.'
CODE COMPLIANCE
• Meets UBC and ICC National Codes and
listed with CEC.
• Incoloy stainless steel lower element lasts • Complies with the Federal Energy
longer than a standard copper element. Conservation Standards effective
DYNACLEAN' DIFFUSER DIPTUBE April 16, 201 S, In accordance with the
Energy Policy and Conservation Ad
• Helps reduce lime and sediment buildup (EPCA), as amended.
and maximizes hot water output. Made
from long-lasting PEX cross-linked
polymer.
HIGH ENERGY FACTORS
• Eco -friendly non -CFC foam insulation,
heat [raps and other features combine
to yield a higher Energy Factor that
maximizes savings on operating costs.
COREGARD'"ANODE ROD
• Our anode rods have a stainless steel
core that extends the life of the anode
rad allowing superior tank protection far
longer than standard anode rods.
BLUE DIAMOND' GLASS COATING
• Provides superior corrosion resistance
compared to industry standard glass
lining.
ENHANCED -FLOW BRASS DRAIN VALVE
• Our residential water heaters have a solid
brass, tamper resistant, enhanced -Row,
hall type, drain valve.
• Uses a standard female hose fitting that
allows for fast and easy draining during
maintenance.
• Designed for easy operation, this valve
includes an integral screwdriver slot that
features a'h turn (open/close) radius,
which not only permits full straight -
through water flow but also a quick and
positive shut off.
'Model muo has a tingle element.
APPROVED FOR MANUFACTURED
HOUSING
• All residential electric water heaters are
compliant with HUD Standards for mobile
homeslmanufactured housing.
CERTIFIED TO UL 174 FOR HOUSEHOLD
ELECTRIC WATER HEATERS
CSA CERTIFIED AND ASME RATED T&P
RELIEFVALVE
DESIGN -LISTED BY UNDERWRITERS
LABORATORIES
• Certified at 300 psi test pressure and 150
psi working pressure.
• Listed according to UL 174 standards
governing storage tank -type electric water
heaters.
6 -YEAR LIMITED TANK AND PARTS
WARRANTY
• For complete information, consult written
warranty or go to horwateccom.
GO - UL
0 febmary 2016 A. 0. Smith Corporation. All rights resened. Page 1 011
wwwbolwater.am 190652]-1953Ta11-free USA IA. U. Smith corporation 1500 Tennessee Walta Parkway I Avland City, TN 37015 AOSEES0602
CeSmith.
Residential Electric
Water Heaters
` Model
Nu bet
Gallon
(zpaclt9
Ffeet Hour
If a
Patin
Sr'Hour
She
Fa ttor
Recovery SO
90 F P se
Gallhe Per
Element'Vil 240V
r .'Olmensions
in In e5
Air....
9hlppIng
We l(I
Stan daed Maximum A- B
6
-rTali.hloEels -
Still
ENT40T
4500006
-
1-re4
3 P4
118
•
50
70
'195
21
4500
6000
60.114
51-1/4
21
131
Fill
ENT -501
50
]1
0.95
23
4500
6000
60.112
51-114
R
134
ENT -551
55
76
0.94
21
45C0
6000
56-112
48-112
24
145
ENSB-30• 1
30
48
095
21
4500
6000
39
30-112
20
1 95
ENB-301
30
49
0 95
21
4500
6000
39314
30-1/2
22
94
Eri
40
55
0.95
21
4500
6000
50
40314
201
109
EN&501
50
62
095
21
4500
6000
49314
40.318
23
161
Ell
19.5
NIA
NSA
21
4500
6000
30
21114
20
65
EN LB -30'
28
40
0.95
21
4500
6000
30
21-314
22
96
ENId Ot
28
43
0.95
-----T-0
6000
31-114
21314
24
115
ENLB-40'
38
46
0.95
31
4500
6000
31314
24
24
118
ENL -401.
38
44
GAS
2l
4500
6000
33412
24
26
My
ENLB-50't
48
51
0.95
21
4500
6000
34
25
26IS
1)2
Male 314' water conne;tlons 11 8. cemer.
Nodelvblp romsupplied insulation bhnket.
trot 10 par tank and 6 year pans warmn, change 'E 11-P In the mSd,ll numb..lea mple_11130b ...... ENT 301.
HopiSE option not available on this model
rNL20 is a single all mnfigurshan only
Optional AP location 121s used on the Ell ENNU, ENT 55, ENS 40 and ENS 50
Top TAP it not availahle on @e 10 year model INLB-50.
Dimensions and 1110 codons vothers to Edi author notice in accordance henna our po4ry oLnntin000s pmdea lmptmement.
T&P VALVE
ACCESS
PANEL
ACCESS
PANEL
DRAIN
VALVE
ANODE (OR OPTIONAL
T&P LOCATION #1)
OPTIONALT&P
° LOCATION #2
JUNCTION
ROX
T&P VALVE
For technical information call eol A, a Smith Corporation reserves the right to make pradutt changes or improvements without prior notice.