HomeMy WebLinkAboutEngineering BUILDING INFORMATION JOB INFORMATION
Design Wind Speed Nominal Mills, Short 8 Associates Client Northcott Residence-Flat Roof Only
Ultimate Wind Velocity(mph) 160
Nominal Wind Velocity(mph) 123.9
Exposure D Eight Hundred Eighth Street PHONE:772226.7282 Address 929 Jackson Way,Fort Pierce,FL
Internal Pressure Enclosed Vero Beach,Florida 32962 CA 030 a9snot1A6sedate&rant
CA fg698 Company Mills,Short&Associates
Height above ground z-(ft) 0.0 Job Number 16-3550
Standard Wall Hei ht- ft 8.0 ASCE 7-10 Pre arer Jason W.Short,P.E.
Mean Roof Hei ht(h - ft 12.0
Building Width ft 78.0
BuildingLength ft 63.0 Version 7.1 TOPOGRAPHIC FACTOR
Roof Slo a x:12 0.3 2004-2012© fill]Shape Flat-No Hill
Roof Angle(degrees) 1.19 11 ft 0.0
a Ede Strip(ft) 4.80 Building Permit Edition Ln ft 0.0
End Zone(ft) 9.60 x ft 0.0
Para et Along Roof Perimeter(ft) 0.00 Wind Load Program �, (ft) 0.0
WIND LOAD DESIGN INFORMATION
Nominal Wind Load Pressures
OPENING EFFECTIVE
WIDTH LENGTH� MAXIMUM MAXIMUM APPLYING WIND LOAD FOR: ZONE ELEVATION WIND AREA NOA Approval Number Max Pressure Per NOA Manufacturer Model Number
Z
(feet) (feet) (feet) (sgft) POSITIVE NEGATIVE
PRESSURE(psf) PRESSURE(pst)
Z Monoslo a -Monoslo a(0-10 de N/A 4.8 4.8 23 14.7 -37.9 FL 1654-R18 -82.5 PSF Polyglass USA System W-52
o Monoslo a -Monoslo a 0-10 de N/A 4.8 4.8 23 14.7 -57.2 FL 1654-1118 -82.5 PSF Polyglass USA System W-52
a Monoslo a -Monoslo a 0-10 de N/A 4.8 4.8 1 23 14.7 -78.3 FL 1654-1118 (-82.5 PSF) Polyglass USA System W-52