HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online
http://www.floridabui lding.org/pr/pi_app_dtl.aspx?param=wGEVX...
BCIS Home !: Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications !, FBC Staff BCIS Site Ma
Business,'
Professional 1 : �*rUSER:PublicUssProduct e�roval
s �• Product ADDroyal Menu > Product or Aoolication Search > Aoolication List > Application Detail
FL # FL15529-R1
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Testing Lab
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
IKO Industries, Ltd
40 Hansen Road South
Brampton, NON -US L6W 3H4
(708)496-2800 Ext 200
rmetzOO1@tampabay.rr.com
Robert Metz
rmetzOO1@tampabay.rr.com
Bob Metz
REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727) 776-5261
rmetzOO1@tampabay.rr.com
Don Shaw
IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717) 579-6706
don.shaw@iko.com
Roofing
Underlayments
Test Report
PRI Construction Materials Technologies, LLC
Keystone Certifications, Inc.
06/26/2025
Zachary R. Priest, P.E.
V Validation Checklist - Hardcopy Received
1 of 2 3/1/2016 1:26 PM
Florida Building Code Online
http://www.floridabuildinc,.org/pr/pr app_ dtl.aspx?param=wGEVX...
Certificate of Independence FL15529 R1 COI FL12838 R2 COI PRI CMT Cert of Ind
FL15529 R1 COI FM - Certificate of Independence 3-25-2C
Referenced Standard and Year (of Standard) Standard Year
D1970 2009
Equivalence of Product Standards
Certified By
Product Approval Method
Method 1 Option B
Date Submitted 06/29/2015
Date Validated 07/14/2015
Date Pending FBC Approval 07/23/2015
Date Approved 10/16/2015
Summary of Products
I
FL # Model, Number or Name
15529.1 StormShield Standard Ice and
Water Protector
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
Description
#7910033
Installation Instructions
FL15529 R1 II SShieldIW0806 Application
2012.pdf
Verified By: PRI Construction Materials Tech
Test Reports
FL15529 R1 TR IKO-081-02-01 Report AS
StormShield Standard Ice and Water Protect
PRI.pd
FL15529 R1 TR IKO-143-02-01 FBC 2014
FL15529.pdf
Back Next
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Cnnvrinht 2007-2013 State of Florida.:: Privary Statement :: Arrpcgihility Statement :: g
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records req
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wi
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. I1
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if yo
Chapter 455, F.S., please click herr.
Product Approva I Accepts.
owic
Niftd ®Check
security. .,,r
2 of 2 3/1/2016 1:26 PM
CONSTRUCTION MATERIALS
TECHNOLOGIES
Brad Grzybowski
Managing Director
July 9, 2015
Dear Sir/Madam,
PRI -CMT tested several products for IKO Industries and subsequently issued Laboratory Test Reports. These
reports have been utilized to support FL15529. This letter serves to establish compliance of legacy test reports
to FBC 2014.
FL15529 — StormShield Standard Ice and Water Protector
Product Specification
• Applicable product specification: ASTM D1970
• FBC 2014 referenced standard year: ASTM D1970-09
• Test Report: PRI Project/Report Number IKO-081-02-01 states compliance to ASTM D1970-08.
• Action: Establish equivalency between ASTM D1970-08 and ASTM D1970-09.
• Conclusion: Compliance to FBC 2014 established.
Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not
have nor plan to acquire a financial interest in any company manufacturing or distributing products for which
the test reports are issued.
Signed:
Brad Grzybo*ki
Managing Director
Date: July 9, 2015
I KO -143-02-01
ri
Signed: r� �` �; L �. f �,.�,
Duc T.,N uyen
Florida Registered Professional Engineer
P.E. Number: 65034
Date:
July 9, 2015
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materiaistesting@pricmt.com WebSite: http://www.pricmt.com
APPLYING IKO'S STORMSHIELD
i
ICE & WATER PROTECTOR
r'
Caution
• Read all instructions before proceeding with application.
• Membrane must always be covered by shingles or other roofing materials. It must not be left exposed
to the weather.
• This product is a vapour retardant. Space under roof deck must be properly ventilated to avoid
moisture condensation.
• In cool temperatures membrane should be tacked in place with mechanical fastenings.
• Installation is not recommended when air and substrate surface temperatures are less than 5°C (40°F)
APPLICATION DIRECTIONS
Surface Preparation
• The roof deck must be clean, smooth, dry and free of sharp protrusions.
• Metal and masonry surfaces must be primed.
Installation
1. Cut the membrane into 3 m to 4.5 m (10 ft. to 15 ft.) lengths.
2. Unroll and align with the lower edge of roof. Tack top edge with four equally -spaced temporary
fasteners.
3. Lift the lower half and remove the lower release film, exposing the adhesive surface.
4. Carefully reposition the membrane down onto the deck and press firmly in place. Avoid wrinkles.
Remove temporary fasteners.
5. Fold top half down and remove release film.
6. Carefully reposition the membrane up onto the deck and press firmly in place. Avoid wrinkles.
• If two courses are required, the top course should overlap the selvage tape on the lower course by
75 mm (3").
• End laps must be at least 15 cm (6") and rolled to ensure adhesion and should be located at least 61
cm (24") from those in the previous course.
• Apply each course carefully.
• Best suited for low sloped roof areas. Cover entire area with StormShield Standard Ice and Water
Protector, lapped as outlined above, and then shingle as per normal shingle exposures.
Valleys and Ridges
• Cut the membrane into 1.2 m to 1.8 m (4 ft. to 6 ft.) lengths. In the valley, start at the low point and
work upwards, overlapping each sheet at least 15 cm (6"). Peel off the release film and centre the
sheet over the valley or ridge. Drape and press in place working from the centre outward toward the
edges.
• Membranes must not be left exposed in an open valley.
Ice Dam Protection
• Membrane must be applied to reach above the highest expected level of ice dams, and at least 61 cm
(24") up the roof from the vertical projection of the interior surface of the outside wall.
Drip Edge
• Drip edges must be located under the membrane at the eaves, and over the membrane at rake edges.
Note
Do not remove selvage tape.
Storage
• Store rolls in their carton until application. Store inside or under cover not over 40°C (104°F)
SShield]W 08-06
SShieldlVV 08-06
Florida Building Code Online
http://www.floridabuilding.org/pr/pr�_app
_dt1.aspx?param=wGE VX. _.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
IKO Industries, Ltd
40 Hansen Road South
Brampton, NON -US L6W 3H4
(708) 496-2800 Ext 200
rmetzOOI@tampabay.rr.com
Robert Metz
rmetzOO1@tampabay.rr.com
Bob Metz
REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727)776-5261
rmetzOO1@tampabay.rr.com
Don Shaw
IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717) 579-6706
don.shaw@iko.com
Roofing
Asphalt Shingles
Certification Mark or Listing
FM Approvals - CER
Locke Bowden
-' Validation Checklist - Hardcopy Received
Standard
ASTM D3161 modified to 110 mph
ASTM D3462
ASTM D7158 Class H
ASTM E108
Year
2009
2009
2008
2007
1 0f 3 7/13/2015 12:06 PM
f
' rk
BCLS Home Log In User Registration -
Hot Topics Submit Surcharge Stats & Facts Publications FRC Staff ? BCLS Site Map j Links Search
Business
Professional
_. -;
pprOVa9
i `' USER: ProdPCb1AUser
App6ot5on DetaN
FL #
FL7006-R9
Application Type
Revision
Code Version
2014
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
IKO Industries, Ltd
40 Hansen Road South
Brampton, NON -US L6W 3H4
(708) 496-2800 Ext 200
rmetzOOI@tampabay.rr.com
Robert Metz
rmetzOO1@tampabay.rr.com
Bob Metz
REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727)776-5261
rmetzOO1@tampabay.rr.com
Don Shaw
IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717) 579-6706
don.shaw@iko.com
Roofing
Asphalt Shingles
Certification Mark or Listing
FM Approvals - CER
Locke Bowden
-' Validation Checklist - Hardcopy Received
Standard
ASTM D3161 modified to 110 mph
ASTM D3462
ASTM D7158 Class H
ASTM E108
Year
2009
2009
2008
2007
1 0f 3 7/13/2015 12:06 PM
Florida Building Code Online
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
http://www.floridabuildin,a.org/pr/pr_app_dtl, aspx?param=wGEVX...
Method 1 Option A
06/28/2015
06/30/2015
Date Approved 07/06/2015
Summary of Products
_ I
FL # Model, Number or Name I Description
7006.1 Cambridge, Cambridge HD and CRC i Laminated architectural fiberglass asphalt shingle
Biltmore AR manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.;
Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants 4
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
7006.2 Hip and Ridge 12 Cap fiberglass
shingles
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure. N/A
Other:
Certification Agency Certificate
&7D06 R9 C CAC FM Letter -,ASTM d3161 letter -
'4-15_2015�df
r- -6--R 9 v .4C : 1 ctL ._AST^r' o2 -tat c
FL 7, 06 Rte. C., rtvAC nt� E �e
f
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
Verified By: Duc T Nguyen 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
This is a 12" x 12" fiberglass asphalt shingle used to cover
the hip and/or ridge of an asphalt shingle roof system
manufactured in Toronto, Ont. and Brampton, Ontario
Certification Agency Certificate
R-7006 R9 C CAC FM Letter - ASTM d3161 letter -
_4-15-2015 .[)df
7
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
Verified By: Duc T Nguyen PE 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
7006.3 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at
Starter Strip ! the bottom of a roof system manufactured in Brampton and
I Hawkesbury, Ontario plants
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
Certification Agency Certificate
FL7006 Ra C C^C_F.i _Letter_: AS1N d31E1 I_erter 4-15-20L-5 .p f
3
Quality Assurance Contract Expiration Date
2 of 3 7/13/2015 12:06 PM
Florida Building Code Online
7006.4
http://www.floridabuilding.org/pr/pi _app_dtl.aspx?param=wGEVX...
12/31/2020
Installation Instructions
.i: _ dF
l "
Verified By: Duc T Nguyen PE 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
Marathon 25 AR, CRC Superglass 3 tab fiberglass asphalt shingle manufactured at IKO's
M25AR Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.;
Sylacauga, AL and Kanakakee, IL plants
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design pressure: N/A
Other:
Certification Agency Certificate
P1,7006 RO C CAC =Ni wetter - ASTi i d3151 leiter-
7
-
5_ nc _ _.._ - 2.. . --.,'S . -
Quality Assurance Contract Expiration Date
12/20/2020
Installation Instructions
Verified By: Duc T Nguyen 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
;Back- :Next
Contact tis :: 194n North Monroe Street Tallahassee FL 12399 Phone: 850-487-1824
The State of Florida 5 an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Priy Statement :: Acressibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emaits provided may be used for official communication with the licensee. However email addresses are public record. N you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here-.
Product Approval Accepts:
L7--:]- 0i_f
* .;43,7
3 of 3 7/13/2015 12:06 PM
rm-Avorova
FM Approvals ember r , FM
1151 Boston -Providence Turnpike
P.O. Box 9102 Norwood, MA 02062 USA
T: 781 762 4300 F: 781 762 9375 www.finapprovals.com
May 3, 2015
Mr. Donald Shaw
IKO Industries, Ltd.
40 Hansen Road South
Brampton, Ontario L6W 3H4
Canada
Customer ID: 1000000686
Subject: IKO Industries Ltd.'s FM Approved asphalt roof shingles
Dear Mr. Shaw,
This letter is being written following in regards to your recent inquire regarding verification of the ASTM
D3161 testing of IKO Industries Ltd's asphalt roof shingles. IKO's shingles that are FM Approved have
been tested in accordance with ASTM D3161 (reports 3040947 and 3038510).
FM Approved products:
IKO Industries Ltd. I Crowne Slate, Cambridge, Hip & Ridge 12, Marathon 25 AR, Marathon
Ultra AR, Cambridge IR, Leading Edge Plus, Cambridge HD, Marathon
25, Hip & Ridge Plus, Dynasty with ArmourZone
Canroof Corporation, Inc. Biltmore, Hip & Ridge 12 (CRC), Superglass 25 M AR, Superglass
Ultra AR, (CRC) Hip & Ridge Plus
Please be advised that shingles noted above tested to previous versions of ASTM D3161 continue
to meet the test criteria of the current version of ASTM D3161.
If you have any questions please do not hesitate to contact me.
Very truly yours,
David L. Alves
Senior Engineer - Materials Group
FM Approvals
1151 Boston -Providence Turnpike
Norwood, MA 02062
T: 781 255 4856
C ct<@> APPROVED
.ate
Phillip J. Smith
Principal Engineer - AVP
FM Approvals
<@>U1 ---
APPROVED ( D
<1 FM Aurovals,
FM Approvals
1151 Boston -Providence Turnpike
P.O. Box 9102 Norwood, MA 02062 USA
T: 781 762 4300 F: 781 762 9375 www.finapprovals.com
May 6, 2015
Mr. Donald Shaw
IKO Industries, Ltd.
40 Hansen Road South
Brampton, Ontario L6W 3H4
Canada
Customer ID: 1000000686
Subject: IKO Industries Ltd.'s glass reinforced asphalt roof shingles
Dear Mr. Shaw,
This letter is being written following in regards to your recent inquire regarding verification of the ASTM
D3462 monitoring IKO Industries Ltd's glass reinforced asphalt roof shingles. IKO's shingles that are FM
Approved and/or Specification Tested Listed are monitored by FM Approvals for compliance with ASTM
D3462. They continue to meet this standard.
If you have any questions please do not hesitate to contact me.
Very truly yours,
r ./ /�
David L. Alves
Senior Engineer - Materials Group
FM Approvals
1151 Boston -Providence Turnpike
Norwood, MA 02062
T: 781 255 4856
E: 0,?vid,ak -,_ _r itttt$)pt ii
< � S
APPROVED
Phillip J. Smith
Principal Engineer - AVP
FM Approvals
APPROVED
rm Aoorovals-
FM
Approvals
1151 Boston -Providence Turnpike
P.O. Box 9102 Norwood, MA 02062 USA
T: 781762 4300 F: 781 762 9375 www.fmapprovals.com
April 15, 2015
Mr. Donald Shaw
IKO Industries, Ltd.
40 Hansen Road South
Brampton, Ontario L6W 3H4
Canada
Customer ID: 1.000000686
Subject: IKO Industries Ltd.'s FM Approved and Specification Tested asphalt roof
shingles
Dear Mr. Shaw,
This letter is being written following in regards to your recent inquire regarding verification of the ASTM
E108 testing of IKO Industries Ltd's asphalt roof shingles. IKO's glass and organic shingles that are FM
Approved and Specification Tested have been tested in accordance with ASTM E108. I have arranged the
shingles by category.
FM Approved products:
IKO Industries Ltd. Cambridge, Cambridge HD, Marathon 25, Marathon 25 AR, Marathon
Ultra AR, Superglass Ultra AR, Crowne Slate, (IKO) Hip & Ridge 12,
Hip & Ridge Plus, Dynasty with ArmourZone, Cambridge IR, Leading
Edge Plus
Canroof Corporation, Inc. Biltmore, Biltmore AR, Superglass 25 M AR, Superglass Ultra AR,
(CRC) Hip & Ridge 12, (CRC) Hip & Ridge Plus
Specification "Tested products:
IIS® Industries Ltd. I Cambridge AR Dual Black, Royal Estate, Marathon 20, Armour Starter,
Armourshake, Roofshake HW
Canroof Corporation, Inc. Biltmore AR Dual Black, Superglass 20, Biltmore AR
Please be advised that shingles noted above tested to previous versions of ASTM E108 continue
to meet the test criteria of the current version of ASTM E108.
If you have any questions please do not hesitate to contact me.
Very truly yours,
r I L12"
David
L. Alves
Senior Engineer - Materials Group
FM Approvals
GY)
APPROUEO
CA.
Phillip J. Smith
TTM - AVP
FM Approvals
APPROVED