Loading...
HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online http://www.floridabui lding.org/pr/pi_app_dtl.aspx?param=wGEVX... BCIS Home !: Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications !, FBC Staff BCIS Site Ma Business,' Professional 1 : �*rUSER:PublicUssProduct e�roval s �• Product ADDroyal Menu > Product or Aoolication Search > Aoolication List > Application Detail FL # FL15529-R1 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Testing Lab Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By IKO Industries, Ltd 40 Hansen Road South Brampton, NON -US L6W 3H4 (708)496-2800 Ext 200 rmetzOO1@tampabay.rr.com Robert Metz rmetzOO1@tampabay.rr.com Bob Metz REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 (727) 776-5261 rmetzOO1@tampabay.rr.com Don Shaw IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 (717) 579-6706 don.shaw@iko.com Roofing Underlayments Test Report PRI Construction Materials Technologies, LLC Keystone Certifications, Inc. 06/26/2025 Zachary R. Priest, P.E. V Validation Checklist - Hardcopy Received 1 of 2 3/1/2016 1:26 PM Florida Building Code Online http://www.floridabuildinc,.org/pr/pr app_ dtl.aspx?param=wGEVX... Certificate of Independence FL15529 R1 COI FL12838 R2 COI PRI CMT Cert of Ind FL15529 R1 COI FM - Certificate of Independence 3-25-2C Referenced Standard and Year (of Standard) Standard Year D1970 2009 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option B Date Submitted 06/29/2015 Date Validated 07/14/2015 Date Pending FBC Approval 07/23/2015 Date Approved 10/16/2015 Summary of Products I FL # Model, Number or Name 15529.1 StormShield Standard Ice and Water Protector Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Description #7910033 Installation Instructions FL15529 R1 II SShieldIW0806 Application 2012.pdf Verified By: PRI Construction Materials Tech Test Reports FL15529 R1 TR IKO-081-02-01 Report AS StormShield Standard Ice and Water Protect PRI.pd FL15529 R1 TR IKO-143-02-01 FBC 2014 FL15529.pdf Back Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Cnnvrinht 2007-2013 State of Florida.:: Privary Statement :: Arrpcgihility Statement :: g Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records req electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487. Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wi they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. I1 supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if yo Chapter 455, F.S., please click herr. Product Approva I Accepts. owic Niftd ®Check security. .,,r 2 of 2 3/1/2016 1:26 PM CONSTRUCTION MATERIALS TECHNOLOGIES Brad Grzybowski Managing Director July 9, 2015 Dear Sir/Madam, PRI -CMT tested several products for IKO Industries and subsequently issued Laboratory Test Reports. These reports have been utilized to support FL15529. This letter serves to establish compliance of legacy test reports to FBC 2014. FL15529 — StormShield Standard Ice and Water Protector Product Specification • Applicable product specification: ASTM D1970 • FBC 2014 referenced standard year: ASTM D1970-09 • Test Report: PRI Project/Report Number IKO-081-02-01 states compliance to ASTM D1970-08. • Action: Establish equivalency between ASTM D1970-08 and ASTM D1970-09. • Conclusion: Compliance to FBC 2014 established. Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Signed: Brad Grzybo*ki Managing Director Date: July 9, 2015 I KO -143-02-01 ri Signed: r� �` �; L �. f �,.�, Duc T.,N uyen Florida Registered Professional Engineer P.E. Number: 65034 Date: July 9, 2015 PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materiaistesting@pricmt.com WebSite: http://www.pricmt.com APPLYING IKO'S STORMSHIELD i ICE & WATER PROTECTOR r' Caution • Read all instructions before proceeding with application. • Membrane must always be covered by shingles or other roofing materials. It must not be left exposed to the weather. • This product is a vapour retardant. Space under roof deck must be properly ventilated to avoid moisture condensation. • In cool temperatures membrane should be tacked in place with mechanical fastenings. • Installation is not recommended when air and substrate surface temperatures are less than 5°C (40°F) APPLICATION DIRECTIONS Surface Preparation • The roof deck must be clean, smooth, dry and free of sharp protrusions. • Metal and masonry surfaces must be primed. Installation 1. Cut the membrane into 3 m to 4.5 m (10 ft. to 15 ft.) lengths. 2. Unroll and align with the lower edge of roof. Tack top edge with four equally -spaced temporary fasteners. 3. Lift the lower half and remove the lower release film, exposing the adhesive surface. 4. Carefully reposition the membrane down onto the deck and press firmly in place. Avoid wrinkles. Remove temporary fasteners. 5. Fold top half down and remove release film. 6. Carefully reposition the membrane up onto the deck and press firmly in place. Avoid wrinkles. • If two courses are required, the top course should overlap the selvage tape on the lower course by 75 mm (3"). • End laps must be at least 15 cm (6") and rolled to ensure adhesion and should be located at least 61 cm (24") from those in the previous course. • Apply each course carefully. • Best suited for low sloped roof areas. Cover entire area with StormShield Standard Ice and Water Protector, lapped as outlined above, and then shingle as per normal shingle exposures. Valleys and Ridges • Cut the membrane into 1.2 m to 1.8 m (4 ft. to 6 ft.) lengths. In the valley, start at the low point and work upwards, overlapping each sheet at least 15 cm (6"). Peel off the release film and centre the sheet over the valley or ridge. Drape and press in place working from the centre outward toward the edges. • Membranes must not be left exposed in an open valley. Ice Dam Protection • Membrane must be applied to reach above the highest expected level of ice dams, and at least 61 cm (24") up the roof from the vertical projection of the interior surface of the outside wall. Drip Edge • Drip edges must be located under the membrane at the eaves, and over the membrane at rake edges. Note Do not remove selvage tape. Storage • Store rolls in their carton until application. Store inside or under cover not over 40°C (104°F) SShield]W 08-06 SShieldlVV 08-06 Florida Building Code Online http://www.floridabuilding.org/pr/pr�_app _dt1.aspx?param=wGE VX. _. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) IKO Industries, Ltd 40 Hansen Road South Brampton, NON -US L6W 3H4 (708) 496-2800 Ext 200 rmetzOOI@tampabay.rr.com Robert Metz rmetzOO1@tampabay.rr.com Bob Metz REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 (727)776-5261 rmetzOO1@tampabay.rr.com Don Shaw IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 (717) 579-6706 don.shaw@iko.com Roofing Asphalt Shingles Certification Mark or Listing FM Approvals - CER Locke Bowden -' Validation Checklist - Hardcopy Received Standard ASTM D3161 modified to 110 mph ASTM D3462 ASTM D7158 Class H ASTM E108 Year 2009 2009 2008 2007 1 0f 3 7/13/2015 12:06 PM f ' rk BCLS Home Log In User Registration - Hot Topics Submit Surcharge Stats & Facts Publications FRC Staff ? BCLS Site Map j Links Search Business Professional _. -; pprOVa9 i `' USER: ProdPCb1AUser App6ot5on DetaN FL # FL7006-R9 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) IKO Industries, Ltd 40 Hansen Road South Brampton, NON -US L6W 3H4 (708) 496-2800 Ext 200 rmetzOOI@tampabay.rr.com Robert Metz rmetzOO1@tampabay.rr.com Bob Metz REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 (727)776-5261 rmetzOO1@tampabay.rr.com Don Shaw IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 (717) 579-6706 don.shaw@iko.com Roofing Asphalt Shingles Certification Mark or Listing FM Approvals - CER Locke Bowden -' Validation Checklist - Hardcopy Received Standard ASTM D3161 modified to 110 mph ASTM D3462 ASTM D7158 Class H ASTM E108 Year 2009 2009 2008 2007 1 0f 3 7/13/2015 12:06 PM Florida Building Code Online Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval http://www.floridabuildin,a.org/pr/pr_app_dtl, aspx?param=wGEVX... Method 1 Option A 06/28/2015 06/30/2015 Date Approved 07/06/2015 Summary of Products _ I FL # Model, Number or Name I Description 7006.1 Cambridge, Cambridge HD and CRC i Laminated architectural fiberglass asphalt shingle Biltmore AR manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.; Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants 4 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 7006.2 Hip and Ridge 12 Cap fiberglass shingles Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure. N/A Other: Certification Agency Certificate &7D06 R9 C CAC FM Letter -,ASTM d3161 letter - '4-15_2015�df r- -6--R 9 v .4C : 1 ctL ._AST^r' o2 -tat c FL 7, 06 Rte. C., rtvAC nt� E �e f Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: This is a 12" x 12" fiberglass asphalt shingle used to cover the hip and/or ridge of an asphalt shingle roof system manufactured in Toronto, Ont. and Brampton, Ontario Certification Agency Certificate R-7006 R9 C CAC FM Letter - ASTM d3161 letter - _4-15-2015 .[)df 7 Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.3 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at Starter Strip ! the bottom of a roof system manufactured in Brampton and I Hawkesbury, Ontario plants Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Certification Agency Certificate FL7006 Ra C C^C_F.i _Letter_: AS1N d31E1 I_erter 4-15-20L-5 .p f 3 Quality Assurance Contract Expiration Date 2 of 3 7/13/2015 12:06 PM Florida Building Code Online 7006.4 http://www.floridabuilding.org/pr/pi _app_dtl.aspx?param=wGEVX... 12/31/2020 Installation Instructions .i: _ dF l " Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: Marathon 25 AR, CRC Superglass 3 tab fiberglass asphalt shingle manufactured at IKO's M25AR Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.; Sylacauga, AL and Kanakakee, IL plants Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design pressure: N/A Other: Certification Agency Certificate P1,7006 RO C CAC =Ni wetter - ASTi i d3151 leiter- 7 - 5_ nc _ _.._ - 2.. . --.,'S . - Quality Assurance Contract Expiration Date 12/20/2020 Installation Instructions Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: ;Back- :Next Contact tis :: 194n North Monroe Street Tallahassee FL 12399 Phone: 850-487-1824 The State of Florida 5 an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Priy Statement :: Acressibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaits provided may be used for official communication with the licensee. However email addresses are public record. N you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here-. Product Approval Accepts: L7--:]- 0i_f * .;43,7 3 of 3 7/13/2015 12:06 PM rm-Avorova FM Approvals ember r , FM 1151 Boston -Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781 762 9375 www.finapprovals.com May 3, 2015 Mr. Donald Shaw IKO Industries, Ltd. 40 Hansen Road South Brampton, Ontario L6W 3H4 Canada Customer ID: 1000000686 Subject: IKO Industries Ltd.'s FM Approved asphalt roof shingles Dear Mr. Shaw, This letter is being written following in regards to your recent inquire regarding verification of the ASTM D3161 testing of IKO Industries Ltd's asphalt roof shingles. IKO's shingles that are FM Approved have been tested in accordance with ASTM D3161 (reports 3040947 and 3038510). FM Approved products: IKO Industries Ltd. I Crowne Slate, Cambridge, Hip & Ridge 12, Marathon 25 AR, Marathon Ultra AR, Cambridge IR, Leading Edge Plus, Cambridge HD, Marathon 25, Hip & Ridge Plus, Dynasty with ArmourZone Canroof Corporation, Inc. Biltmore, Hip & Ridge 12 (CRC), Superglass 25 M AR, Superglass Ultra AR, (CRC) Hip & Ridge Plus Please be advised that shingles noted above tested to previous versions of ASTM D3161 continue to meet the test criteria of the current version of ASTM D3161. If you have any questions please do not hesitate to contact me. Very truly yours, David L. Alves Senior Engineer - Materials Group FM Approvals 1151 Boston -Providence Turnpike Norwood, MA 02062 T: 781 255 4856 C ct<@> APPROVED .ate Phillip J. Smith Principal Engineer - AVP FM Approvals <@>U1 --- APPROVED ( D <1 FM Aurovals, FM Approvals 1151 Boston -Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781 762 9375 www.finapprovals.com May 6, 2015 Mr. Donald Shaw IKO Industries, Ltd. 40 Hansen Road South Brampton, Ontario L6W 3H4 Canada Customer ID: 1000000686 Subject: IKO Industries Ltd.'s glass reinforced asphalt roof shingles Dear Mr. Shaw, This letter is being written following in regards to your recent inquire regarding verification of the ASTM D3462 monitoring IKO Industries Ltd's glass reinforced asphalt roof shingles. IKO's shingles that are FM Approved and/or Specification Tested Listed are monitored by FM Approvals for compliance with ASTM D3462. They continue to meet this standard. If you have any questions please do not hesitate to contact me. Very truly yours, r ./ /� David L. Alves Senior Engineer - Materials Group FM Approvals 1151 Boston -Providence Turnpike Norwood, MA 02062 T: 781 255 4856 E: 0,?vid,ak -,_ _r itttt$)pt ii < � S APPROVED Phillip J. Smith Principal Engineer - AVP FM Approvals APPROVED rm Aoorovals- FM Approvals 1151 Boston -Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781762 4300 F: 781 762 9375 www.fmapprovals.com April 15, 2015 Mr. Donald Shaw IKO Industries, Ltd. 40 Hansen Road South Brampton, Ontario L6W 3H4 Canada Customer ID: 1.000000686 Subject: IKO Industries Ltd.'s FM Approved and Specification Tested asphalt roof shingles Dear Mr. Shaw, This letter is being written following in regards to your recent inquire regarding verification of the ASTM E108 testing of IKO Industries Ltd's asphalt roof shingles. IKO's glass and organic shingles that are FM Approved and Specification Tested have been tested in accordance with ASTM E108. I have arranged the shingles by category. FM Approved products: IKO Industries Ltd. Cambridge, Cambridge HD, Marathon 25, Marathon 25 AR, Marathon Ultra AR, Superglass Ultra AR, Crowne Slate, (IKO) Hip & Ridge 12, Hip & Ridge Plus, Dynasty with ArmourZone, Cambridge IR, Leading Edge Plus Canroof Corporation, Inc. Biltmore, Biltmore AR, Superglass 25 M AR, Superglass Ultra AR, (CRC) Hip & Ridge 12, (CRC) Hip & Ridge Plus Specification "Tested products: IIS® Industries Ltd. I Cambridge AR Dual Black, Royal Estate, Marathon 20, Armour Starter, Armourshake, Roofshake HW Canroof Corporation, Inc. Biltmore AR Dual Black, Superglass 20, Biltmore AR Please be advised that shingles noted above tested to previous versions of ASTM E108 continue to meet the test criteria of the current version of ASTM E108. If you have any questions please do not hesitate to contact me. Very truly yours, r I L12" David L. Alves Senior Engineer - Materials Group FM Approvals GY) APPROUEO CA. Phillip J. Smith TTM - AVP FM Approvals APPROVED