HomeMy WebLinkAboutProduct Approval (3) lits;; ���, ����rr•�
APR ? a1�
PERfY?1TT1NC
MIAMI•IJADE Si. Lucie Counly, EL N-11AMI-DADIC COUNTY
c PRODUCT CONTROL SECTION
11805 SW 26 Slreet, Room 208
Dlsl'AR'I iV(IsN'1'OI RIsGULA'l'ORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMiNISTRATION DIVISION T(786)315-2590 F(79 6)31525-99
NOTICE OF ACCEPTANCE (NOA) 1vw.v.m is nlidad e.rroylee()1I of11y.
CertainTeed Corporation
1400 Union Meeting Road, P.O. Box 1100
Blue Bell, PA. 1,9422-0761
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
dOCUMentatiOn submitted has been reviewed and accepted by Miami-Dade County IZER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. if this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. IZ1✓R reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida i3uilding Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over-Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise rioted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur atter the expiration date or if there has been a revision or change in the
materials, use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, than it shall be done
in its entirely.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA#13-0204.03 and consists of pages 1 through M.
The submitted docurnentation was reviewed by Alex Tigera.
l
MIAMI•DADE COUNTY
NOA No.: 14-0224.03
• 1 Expiration Date: 06/19/18
\ Approval Date: 04/10/14
1 J a 1 Page I of 16
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Type: Wood
Maximum Dcsign Pressure: -60 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
All Weather/Empire Base 36" x 65'10"; ASTM D 4601 Type Asphalt coated, fiberglass reinforced
Sheet Roll weight: 86 lbs. Il base sheet
(2 squares) UL Type 15
Flex-l-GlasTM Base Sheet 36" x 98'9'; Roll ASTM D 4601,Type Modified Bitumen coated fiberglass
weight: 90 lbs. II base sheet.
(3 squares) UL Type G2
Flex-l-GlasTm FR Base Sheet 39 3/8" x 50; Roll ASTM D 6163, Modified Bitumen coated fibergtass
weight: 90 lbs. Grade S,Type I base sheet.
(1.5 squares)
FlintglasOO Ply Sheet Type IV 36" x 164'7"; Roll ASTM D 2178 Type Fiberglass, asphalt impregnated ply
or VI weight: 40/55 lbs. IV or VI sheet.
(5 squares) UL Type G 1
Flintlastic STA 39 3/8" x 33; Roll ASTM D 6222, Smooth surfaced APP Modified
weight: 90 lbs. Grade S,Type II Bitumen membrane with non-woven
(1 square) polyester that reinforcement for torch
application.
Flintlastic GTA,GTA-FR 39 3/s" x 33'3"; Roll ASTIVI D 6222, Granule surfaced APP Modified
weight: 105 lbs. Grade G,Type 11 Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application.
Flintlastic GMS, 39 3/8" x 34'2"; Roll ASTM D 6164, Granule surfaced SBS Modified
GMS Premium weight: 100/105 lbs. Grade G,Type II Bitumen membrane with non-woven
(I square) polyester mat reinforcement for mop
application.
Flintlastic FR, 39 3/8" x 34'2"; Roll ASTIVI D 6164, Fire resistant,granule surfaced SBS
FR-P Premium weight: 105 lbs. Grade G,Type I Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop application.
Flintlastic FR Cap Sheet 39 3/8" x 34'2"; Roll ASTM D 6163, Fire resistant, granule surfaced SBS
weight: 90 lbs. Grade G,Type 1 Modified Bitumen membrane with
(I square) fiberglass mat reinforcement for mop
applications.
NOA No.: 14-0224.03
MIAMI•DADE COUNTY
Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 2 of 16
TRADE NAMrS Or PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TAI;[,1..I
Test Product
Product Dimensions Specification Description
Flintlastic FR Cap T 39-3/8"x 34'2"; Roll ASTM D6163 Granule surfaced SBS Modified
weight: 8I lbs. Bitumen membrane with fiberglass
(1 square) mat reinforcement for torch
application.
Flintlastic FR Base T 39-3/8"x 33'; Roll ASTM D6163 Modified Bitumen, coated fiberglass
Weight: 81lbs. base sheet for torch application.
(1.0 squares)
Flintlastic FR Cap CoolStar 39 3/8" x 34'2"; Roll ASTM D 6163 Fire resistant, granule surfaced SBS
weight: 90 lbs. Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic FR Cap T CoolStar 39%" x 34'2"; Roll ASTM D 6163 Fire resistant,granule surfaced SBS
weight: 90 lbs. Modified Bitumen membrane with
(I square) fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic GTA,GTA-FR 39 3/8" x 33'3"; Roll ASTM D 6222 Granule surfaced APP Modified
CoolStar weight: 1.05 lbs. Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application. Covered with reflective
CoolStar Coating.
Flintlastic GMS/GMS 393/8" x 34'2"; Roll ASTM D 6164 Granule surfaced SBS Modified
Premium CoolStar weight: 100/105 lbs. Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for mop
application. Covered with reflective
CoolStar Coating.
Flintlastic FR-P/FR-P Premium 39 3/8" x 34'2"; Roll ASTM U 6164 Fire resistant,granule surfaced SBS
CoolStar weight: 105 lbs. Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop application.
Covered with reflective CoolStar
Coating. Covered with reflective
CoolStar Coating.
Ultra Poly SMS 36"x 64'4" ASTM D 6164, Smooth surfaced SBS Modified
(2 squares) Grade S,Type l Bitumen Membrane with non-woven
polyester mat reinforcement for mop
applications.
NOA No.: 14-0224.03
MIAMIDAD;
.0UNTY15NNW Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 3 of 16
r
ilasBascT"' Base Sheet 36" x 98'9"; Rol! ASTM D 4601 Asphalt coated, fiberglass base sheet.
weight: 69 lbs. UL Type G2
(3 squares)
PolySMS Base Sheet 39 3/e" x 64'4"; Roll ASTM D 4601, Modified Bitumen coated polyester
weight: 90 lbs. Grade S,Type 11 base sheet.
(2 squares) UL Type G2
YosemiteO Buffer Base Sheet 36" x 3210"; Roll ASTM 133909 Mineral Surfaced fiberglass reinforced
weight: 90 lbs. ASTM D 4897 buffer sheet.
(I square) UL Type 30
Black Diamond"' Base Sheet 36" x 68'7"; Roll ASTM D 1970 Sell:-adhering fiberglass reinforced
weight: 78 lbs. modified bitumen base sheet
(2 squares)
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
FIintBoard ISO Polyisocyan u rate foam insulation CertainTeed Corporation
ACFoam -11 Polyisocyanurate foam insulation Atlas Roofing Corporation
High Density Wood Fiberboard Wood fiber insulation board Generic
Perlite Insulation Perlite insulation board Generic
DensDeck, DensDeck Prime Water resistant gypsum board Georgia Pacific Gypsum LLC
1-I-Shield Poly isocyanu rate foam insulation Hunter Panels LLC
ENRGY 3, ENRGY 3 25 PSI Poly isocyanu rate foam insulation Johns Manville Corp.
Multi-Max FA-3 Poly isocyanu rate foam insulation RMax Operating, LLC
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. None N/A None N/A
NOA No.: 1.4-0224.03
MIAMI•DADECOUNTY Expiration Date: (16/19/18
Approval Date: 04/10/14
Pare 4 of 16
EVIDENCE SuBmi TED:
Test Agency/Identifier Name Report Da to
Factory Mutual Research Corp. FMRC 4470 J.1. 3Y8A 1.AM 03/23/96
FM.RC 4470 J.I. OD3A3.AM 04/01/97
FMRC 4470 J.I. 2DOAO.AM 12/23/98
FMRC 4470 J.I. ID7A4.AM. 11/09/98
Underwriters Laboratories, Inc. UL 790 R1 1656 01111/13
United States Testing Company ASTM D 5147 97457-4 06/03/88
ASTM D 5147 97-457-2R 12/02/87
Momentum Technologies, Inc. ASTM D 4601 AX31G8D 09/05/08
ASTM D6164 AX31G8F 06/05/09
ASTM D6222 AX31G8G 06/05/09
ASTM D 3909/D 4897 AX31G8C 09/05/08
TrinitylERD TAS I I4(J) #3504.06.01-1 06/05/01
TAS 117 (B) 3503.10.06 10/10/06
TAS 117(I3) 06490.04.07-RI 06/27/07
TAS 114(H) Letter 04/OS/06
"rAS 114 3533.01.06 01/06/06
TAS 114 3521.07.04 07/29/04
TAS 117(B)/ASTM D 6862 C8SOOSC.11.07 11/30/07
TAS 114 C8370.08.08 08/1.9/08
ASTM Physical Properties C10080.09.08-R4 03/25/10
ASTM D6164/134798 C31410.01.11-2 O 1/10/l I
ASTM D4601 C40050.09.12-1 09/28/12
ASTM D 1970 C40050.09.12-2 09/28/12
ASTM D5147/134798 C31410.10.10-R I I 1/01/t2
ASTM D5147/D4798 C31410.01.11-1-R1 11/01/12
ASTM D4798 C31410.01.11-2A-R 1 02/21/13
ASTM D4798 C31410.12.13 12/05/13
ASTM D6222 C400SO.12.13 12/05/13
PRI Construction Materials ASTM D6163 CTC-032-02-01 01/22/08
Technologies LLC ASTM D6163 CTC-066-02-01 08/09/11
ASTM D6164 CTC-068-02-01 08/09/11
ASTM D6222 CTC-070-02-01 08/09/11
ASTM 136164/134799 CTC-093-02-01 08/09/11
ASTM D2178 CTC-122-02-01 03/13/12
ASTM D2178 CTC-123-02-01 03/13/12
ASTM D4601 CTC-127-02-01 03/13/12
ASTM D6163 CTC-128-02-01 06/11/12
ASTM D6163 CTC-129-02-01 06/11/12
ASTM D6164 CTC-132-02-01 06/11/12
ASTM D6164 CTC-162-02-01 05/09/13
ASTM [36164 CTC-161-02-01 OS/09/13
ASTM D6162 CTC-183-02-01 10/02/13
ASTM D6164 CTC-190-02-01 12/02/13
NUA No.: 14-0224.113
QADI•DECOUNTY Expiration Date: 06/19/18
Approval Date: 04/1.0/14
Page 5 of 16
Membrane Type: APP Modified
Deck Type II: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank
System Type E(l.): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet, Glas Base or Flintglas Premium Ply Sheet (Type
VI) mechanically attached as detailed below.
Fastening: Base sheet shall be lapped 4" and fastened with l I ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: (Optional ) One ply of All Weather/Empire Base Sheet, Ultra Poly SMS, Glas Base, F lex-I Glas
Base, Flex-I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet(Type IV) or
Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 IUs./sq. or one ply of Black Diamond Base Sheet
self-adhered or Flintlastic STA torch adhered.
Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or GTA-FR CoolStar torch
adhered to base/ply sheet.
Surfacing: (Optional)Any coating, listed below, used as a surfacing, must be listed within a current NOA.
Install one of the following:
1. 400-1b./sq.gravel or 300-Ib./sq.slag in a flood coat of approved mopping asphalt at an
application rate of 60 Ib./sq.
2. Karnak(#97 AF) Fibrated Aluminum Roof Coating, FlintCoat A-150, APOC #212
Fibrated Aluminum Roof Coating at an application rate of 1 '/2 gal./sq
Maximum Design
Pressure: -52.5 psf. (See General Limitation 97)
NOA No.: 14-0224.03
MIAMI•DAD;COUNTY Expiration Dale: 06119/18
Approval Date: 04/10/14
Page 12 of 16
i`
WOOD DECK SYSTEM LIMITATIONS:
I. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and ata rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three roNvs, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested,are below
275 lbf insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required,as determined by the Building Oficial, a revised fastener spacing,
prepared,signed and sealed by a Florida registered Professional Engineer, Registered Architect,or,Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General. Limitation 0 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
J. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,
perimeters,and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones(i.e. perimeters,extended cornets and corners). (When this limitation is specifically
referred within this NOA,General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61020-3 of the Florida Administrative Code,
END Or THIS ACCEPTANCE
NOA No.: 14-0224.03
MIAM4DAD;eouNTY Expiration Date: 06/19/18
Approval Date: 04/10/14
Page 16 of 16