HomeMy WebLinkAboutProduct Review Affidavit Ii
Florida Building Code Online Page 4 of 5
Impact Resistant:N/A FL11651 R2 T 151 12 R2 Metal Roof Panel_Detall.Ddf
Design Pressure:+N/A/-156.SPSF Verified By:Dan Kuhn,P.E.75519�I
Other:-108.5 psf @ 12"o.c.fastener spacing.-156.5 Created by Independent Third Party:Yes
psf @ 6"o.c.fastener spacing.Install per Evaluation Reports
manufacturers details.For use in HVHZ Zones. FL11651 R2 AE 14FL11651 12 R2 265vCrimo 15-
32Plvwood HVHZ.odf "
Created by Independent Third Party:Yes
11651.13 26 Ga.SV Crimp 26 Ga.5V Crimp over 15/32"Plywood
Limits of Use Installation Instructions k
Approved for use in HVHZ:No FL11651 R2 II 14FL11651 13 R2 I 265vCrimo_15-
Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.adf !
Impact Resistant:N/A FL11651 R2 II 14FL1i651 13 R2 Metal Roof Panel Detail.Ddf
Design Pressure:+N/A/-131.PSF Verified By:Dan Kuhn,P.E.75519'1
Other.-94.25 psf @ 16"o.c.fastener pattern.-131.0 Created by Independent Third Parry:Yes
psf @ 16"o.c.fastener pattern.Install per Evaluation Reports i!
manufacturers details.Not for use In HVHZ Zones. FL11651 R2 AE 14FL11651 13 R2 265vCrimD 15-
32Plvwood NonHVHZ.Ddf 1
Created by Independent Third Party:Yes
11651.14 26 Ga.SV Crimp 26 Ga.5V Crimp Roof Panel over 1x4 Wood Purfins over 15/32"
Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R2 II 14FL11651 14 R2 265vCrimo 1x4 IS-
Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.Ddf j
Impact Resistant:N/A FL11651 R2 II 14FLII 51 14 R2 Metal Roof Panel Detail.odf
Design Pressure:+N/A/-156.SPSF Verified By:Dan Kuhn,P.E.75519 1
Other:-108.5 psf @ 12"o.c.fastener spacing.-156.5 Created by Independent Third Party:Yes
psf @ 6"o.c.fastener spacing.Install per Evaluation Reports 1 I,
manufacturers details.For use in HVHZ Zones. FL11651 R2 AE 14FL11651 14..R2 265vCrimo 1x4 IS-
32Plvwood NonHVHZ.r) ;1
Created by Independent Third Party:Yes
11651.15 26 Ga.Gulf Lok 26 Ga.Gulf Lok 16"Wide Roof Panel over 15/32"Plywood
Limits of Use installation Instructions '!
Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 15 R2'26GulfLok 16 15-
Approved for use outside HVHZ:Yes 32Plvwood HVHZ.pdf
Impact Resistant:N/A FL11651 R2 II 14FL11651 15 R2 Metal Roof Panel Detail.odf
Design Pressure:+N/A/-161.OPSF Verified By: Dan Kuhn,-P.E.755191
Other:-63.5 psf @ 5 3/16"o.c.fastener spacing. Created by Independent Third Party:Yes
-121.75 psf @ 5 3/16"spacing.-161.0 psf @ 5 3/16" Evaluation Reports
o.c.fastener spacing.Install per manufacturers details. FL11651 R2 AE 14FL11651 15 R2 26GulfLok 1615-
For use in HVHZ Zones. 32Plvwood HVHZ.odf
Created by Independent Third Party:Yes
11651.16 26 Ga.Gulf Lok 26 Ga.Gulf Lok 16"Wide Roof Pariel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R2 II 14FL11651 16 R2 26GUHLok 16 15-
Approved for use outside HVHZ:Yes 32Plvwood No HVHZ.Ddf I
Impact Resistant:N/A FL11651 R2 I1 14EL11651 16 R2 Metal Roof Panel Detail.odf
Design Pressure:+N/A/-63.5PSF Verified By:Dan Kuhn,P.E.755191
Other:-63.5 psf @ 5 3/16"o.c.fastener spacing. Created by Independent Third Party:Yes
-121.75 psf @ 5 3/16"fastener spacing.-161 psf @ 5 Evaluation Reports I 1
3/16"fastener spacing.Install per manufacturers FL11651 R2 AE 14FL11651 16 R2 26GulfLok 16 15-
details.Not for use in HVHZ Zones. 32Plvwood Not HVHZ.odf I
Created by Independent Third Party:Yes
11651.17 26 Ga.GulfPBR 26 Ga.Gulf PBR Roof Panel over 15/32"Plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11651 R2 II 17 R2 26GulfPB 15-32Plvwood NonHVHZ Ddf
Approved for use outside HVHZ:Yes FL11651 R2 II 17 R2 Metal Roof Panel Detafl.Ddf
Impact Resistant:N/A Verified By:Dan Kuhn;P.E.75519
Design Pressure:+N/A/-154.7PSF Created by Independent Third Party:Yes
Other:-59.25 psf @ 24"o.c.fastener pattern.-154.75 Evaluation Reports 11,
psf @ 12"o.c.fastener pattern.Install per FL11651 R2 AE 17 R2 26Gu1fPBR 15-
manufacturer details.Not for use in HVHZ 32Plvwood NonHVHZ.Ddf
Created by Independent Third Party:Yes
11651.18 26 Ga.GUIfPBR 26 Ga.GUIfPBR Roof Panel over 1x4 Wood Purlins over 15/32"
Plywood -i
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL11651 R2 II 14FL11651 18 R2 26GulfPBR 1x4 1S-
Approved for use outside HVHZ:Yes 32Plvwood HVHZ.Ddf !
Impact Resistant:N/A FL11651 R2 II 18 R2 Metal Roof Panel Detail.Ddf
Design Pressure:+N/A/-151.7PSF Verified By:Dan Kuhn,P.E.75519
Other:-100.5 psf @ 24"o.c.fastener spacing. Created by Independent Third Party:Yes
-151.75 psf @ 12'fastener spacing.Install per Evaluation Reports
manufacturer's details.For use in HVHZ Zones FL11651 R2 AE 14FL11651 18 R2 26GUIfPBR ix4 15
I
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2ffr... 1/20/2016
i
Florida Building Code Online Page 1 of 2
* � �. �- � -� r..>-R-� ��� a :;,.. -�•-�2 �
e� � c''tAa? �`` ' i� e l f��l#Y•.-t Xl-,# ������° 9-j �`�� •.
+3"'" � ,.. .� s.�-.i- •:..-�:.:._.�-,:rs.....-.v__. a�'�'T! •%��5'i��+�ST_J�.`�=�s^"'e" �s-z
SCIS Name Log In User Registration Hot Topics SubmiE Surcharge Stats°u Facts Publicatiom FEC Staff SCIS Site Map Links Search
Busines •,
Professional + USER:PupicUProdct ser al
Product APProyEd Menu>Product cr Aoulication Search>Application List>Application Detail
--ate c
k t M FL FL2569-R10
Application Type Revision
Code Version 2014
Application Status Approved
Comments
L
Archived
Product Manufacturer Soprema,Inc.(Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berrhmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggerty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M.Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W.Knezevich,PE
I
J Validation Checklist-Hardcopy Received
I
Certificate of Independence df
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6163 2000
ASTM D6164 2005
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
TAS 110 2000
http://w-ww.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 10... 8/19/2015
r�
.i
Florida Building Code Online i Page 2 of 2
�I
ij
i
I,
Equivalence of Product Standards
Certified By
Sections from the Code i
Product Approval Method Method 1 Option D
i
Date Submitted 06/29/2015 i
Date Validated 07/02/2015 ;
Date Pending FBC Approval 07/09/2015 .j
Date Approved 08/18/2015
summary of Products
i
FL# Model,Number or Description
Name
2569.1 Soprema Roof Self adhering roof underiayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVH2:No FL2569 R10 II 2015 06 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:Yes R10.odf
Impact Resistant:N/A Verified By:Robert Nleminen,P.E.PE-59166 j
Design Pressure:+N/A/-90 Created by Independent Third Party:Yes
Other.1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use.2.)The design pressure FL2569 R10 AE 2015 06 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
noted herein pertains to undedayment R10.odf
systems used beneath adhesive-set tile Created by Independent Third Party:Yes
systems.Refer to ER Section 5.6.4 for
details.
i
Back Next r�
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824'
The State of Florida is an WEED,employer.Co ivriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuantto
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the publi:!To determine if you are a licensee under
Chapter 455,FS.,please click here. j
Product Approval Accepts-
M1
II
sururitvnii
I
tjt
t!'
i
�I
,i
,I
I,
t;
�I
I
http://w-vw.floridabuildinor.org/nr/pr app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB10... 8/19/2015
„
'i
' I
• I
_ _ 1
ti. EXTERIOR-RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
Ti 353 CHRISTIAN STREET,UNIT#13
RINITY'•ER® OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT !
Soprema,Inc. Evaluation Report 518010.06.09-R8
1640 rue Haggerty ! FL2569-R10
Drummondville,Quebec 12C 5P8 Date of Issuance:06/15/2009
Canada i' Revision 8:06/29/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code,'!Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
I
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if�the product changes or the
referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle. i,
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityiERD Evaluated" may be displayed in
advertising literature. if any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M.Nieminen P.E. ••J4_ The huimileseal appearing was authorized byRobert Nieminen,
Nieminen, 'P'F=:v^t0,`t.•.`r;-�i� P.E.on 06/29/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 C:!���ip ;•k° docume�Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named diets
CERTIFICAmoN OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued. 1
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
I
S. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen,P.E.are,in,any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
I
i
{ `S
{ f TRINITY;ERD
i
4.8 Lastobond is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen Eroof underlayment.
4.9 Lastobond Eco is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced;]SBS modified bitumen roof
underlayment.
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,
with a 36-inch sheet width.
i
4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified
bitumen roof underlayment,with a 36-inch sheet width. I .i
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified,'bitumen roof underlayment,
with a 44-inch sheet width.
4.14 Colphene FR GR is a self-adhering,fiberglass reinforced,granule-surfaced,SBS modified bitumen roof underlayment.
4.15 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
5. LIMITATIONS: j
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E.are, in any way,the Designer of
Record for any project on which this Evaluation Report,or previous versions thereof;;is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
i
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE 1:ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile' Metal Wood Shakes& Slate
Shingles Shingles
Lastobond TU HT Yes Yes Yes Yes 1, Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N/ Yes No No No I Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes I Yes Yes
Lastobond/Lastobond 195 Yes No No No Yes Yes
Lastobond ECO/RESISTO LB1236,
Grip-Rite Eave&Valley Protector/ Yes No No No Yes Yes
RESISTO LB1244
VI Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes Yes No Yes Yes
See 5.5.1
Unilay(e) Yes Yes Yes No' No No
Batten Only See 5.5.1 i
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion/1long term aging data from an
accredited testing laboratory is provided.
Underlayment Adhesive(s)
3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBondTM Roof
Lastobond TU HT Tile Adhesive(FL717)
t
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
�i
Exterior Research and Design,LLC. Evaluation Report S18010.06.09-R8
CerhTicate ofAathoraaBan#9503 ,i FL2569-R10
Revision 8:06/29/2015
Page 3 of 6
TRINITY"ER®
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-S
applied to:
➢ Plywood,ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave &Valley Protector,
RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;ASTM D41 primed structural concrete_
Colphene FR GR applied to:
➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates,Soprema recommends priming with
Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
• Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S or Colphene FR GR applied to:
➢ DensDeck DuraGuard;DensDeck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S or
Colphene FR GR applied to:
➢ ASTM D226,Type 1 or II felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems,base layer shall be attached in accordance with
FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on the systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocol Stick or Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
I
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-RS
CertiTicate o/Authorization 719503 FL2569-R10
Revision 8:06/29/2015
Page 4 of 6
I
i
,,J: TRIM ERa
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AH1.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c,at the 4-inch laps and 6-inch o.c.in three,equally spaced rows in the
center of the sheet.
Underlayment: Colphene FR GR,self-adhered
5.6.4.4 Maximum Design Pressure=-90.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AH1.
Underlayment: Unilay(e)mechanically attached with Soprafix Polymer Batten Bari(PBB)or Soprafix Metal Batten
Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c.l within the 5-inch wide, self-
adhering side laps. End laps are 6-inch wide and sealed using either heat-welding or hot-air
welding techniques.
5.7 Exposure Limitations:
5.7.1 Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond, Lastobond 195,Lastobond Eco,
Lastobond Smooth Seal HT, RESISTO LB1236,Grip-Rite Eave&Valley Protector or R i ISTO LB1244 shall not be left
exposed for longer than 30-days after installation.
5.7.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation.
5.7.3 Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate with Elastocol Stick or Elastocol 600c(if applicable).
6_3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S,Lastobond,Lastobond 195 Lastobond Eco Lastobond Smooth Seal HT RESISTO LB3236 Grip-
Rite Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the
type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover
is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release
film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using
either heat-welding or hot air welding techniques.
When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of the sheet
at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge.Drape and press sheet into place,working from the center of the valley or ridge in each direction. For
valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For Colphene FR GR in foam-on tile applications, reference is made to Section 5.I.4 herein for wind resistance
limitations.
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment.
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R8
Certificate ofAuthoraation#9503 FL2569-R10
Revision 8:06/29/2015
Page 5 of 6
i
TRINITY ERD
6_4 Unila e:
6.4.1 Non-Tile Applications or Nail-On,Battened Tile Applications:
Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if applicable).
Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope,mechanically attach
the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap(nails spaced 36-inch o.c. Apply
the second course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-
granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile (if applicable) shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
6.4.2 Foam-On Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein.
Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope,mechanically attach
the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar(PBB)or Soprafix Metal Batten Bar
(MBB)with Soprema#15-EL fasteners spaced 6-inch o.c. Apply the second course ir 'a water-shedding manner with
self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a
watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-
granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile shall be loadeand staged in a manner that prevents tile slippage and/or damage t
do the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,U.C. Evaluation Report S18010.06.09-R8
Certificate of Authorization#9503 FL2569-R10
Revision 8:06/29/2015
Page 6 of 6