HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3
i
'I
��� �Iha���M�1�E� ��Si r /S' �}�Y•'3 � a r�„�` � �r .��'�� .� +�. ��
;b �;. ._, �;.,. ;ay �`.r x=.� L a-�" fy. A,; i ,,,� S,i:•�">>r6� � >l����t�"+"x
i
Florld'u Departmelltil SCIS Home j Log In User Registration Hot Topics I Submit Surcharge Stats&Fads PublicationsFBC Staff BCIS Site Map Links j Search j
Business
�_C ���"a°q Product Approval
ProfessiO al z u.rV.PublicUser
Regulation
Product Approval Menu>Product or Application Search>Application List>Application Detail
I VN FL# F1-140 -
�
Application Type A tion
Code Version CApproDved
14
Application Status
Comments
Archived ❑
Product Manufacturer JELD-WEN
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls,OR 976011
(800)535-3936
fbcl@jeld-wen.com
i
Authorized Signature Kaede McLaughlin
fbcl@jeld-wen.com
I
Technical Representative JELD-WEN Corporate Cu(tomer Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls,OR 97601
(800) 535-3936
customerserviceagents@jeld-wen.com
I
Quality Assurance Representative
Address/Phone/Email
Category fSilngle
ws
Subcategory Hung f
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&(Management Institute
Referenced Standard and Year(of Standard) Standard i Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
I
10I affirm that there are,no changes in the new Florida
Building Code which affect my product(s)and my product(s)
are In compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity
0 Yes O No, O N/A
I
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgtGLROI l MyCBy 1 Jk... 4/29/2016
Florida Building Code Online Page 2 of 3
Product Approval Method Method 1 Option A
Date Submitted 02/20/2015
Date Validated 02/20/2015
Date Pending FBC Approval
Date Approved 02/28/2015
Date Revised 02/26/2016
Summary of Products
FL# Model,Number or Name Description
14095.1 Premium Atlantic Vinyl Single Hung(8100)36"x 72"Insulated Glass(5/16 in PVB or SGP Lam-
1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R5 C CAC NI011567.04-R2.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 04/30/2017
Design Pressure:+65/-70 Installation Instructions
Other:Miami-Dade NOAs for Quanex FL14095 R5 II DP65-70 36x72 Impact Installation Instructions.pdf
Building Products,Inc PVC(12-1017.02 and FL14095 R5 II DP65- ,
13-0425.15). Miami-Dade NOAs for Dupont 70 36x72 Wood Through Frame Impact Installation Instructions PDF
SentryGlas(11-0624.02)and Butacite PVB Verified By: Hermes Norero, PE 73778 1
(13-0129.27)Interlayers.IG back bedded Created by Independent Third Party:Yes
with Dow 995. Evaluation Reports
FL14095 R5 AE PER3094.pdf
Created by Independent Third Party:Yes
14095.2 Premium Atlantic Vinyl Single Hung (8100)36"x 72"Insulated Glass(1/8 in-1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R5 C CAC NI011567 08-NI011567 09 pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 04/30/2017
Design Pressure:+65/-70 Installation Instructions
Other:Miami-Dade NOAs for Quanex FL14095 R5 II 36x72 DP65-70 Installation odf
Building Products,Inc PVC(12-1017.02 and FL14095 R5 II 36x72 DP65-70 Throuoh Frame Wood Installation PDF
13-0425.15).IG back bedded with Dow 995. Verified By: Hermes Norero,PE 73778d
Created by Independent Third Party:Yes
Evaluation Reports
FL14095 R5 AE PER3092.pdf
Created by Independent Third Party:Yes
14095.3 Premium Atlantic Vinyl Single Hung(8100)52 1/8"x 75"Insulated Glass(3/16 in-3/16 out
Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R5 C CAC NI011567.06-NI0!11567 07 pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 04/30/2017 i
Design Pressure:+65/-70 Installation Instructions
Other:Miami-Dade NOAs for Quanex FL14095 R5 II 52.125x75 DP65-70 Installation pdf
Building Products,Inc PVC(12-1017.02 and FL14095 R5 II 52.125x75 DP65- I
13-0425.15).IG back bedded with Dow 995. 70 Through Frame Wood Installation.PDF
Windows with insulated glass units wider than Verified By: Hermes Norero,PE 73778
36"require setting blocks. Created by Independent Third Party:Yes
Evaluation Reports j
FL14095 R5 AE PER3093.pdf I
Created by Independent Third Party:Yes
14095.4 Premium Atlantic Vinyl Single Hung(8100)52 1/8"x 75"Insulated Glass(5/16 in PVB or SGP Lam
-1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 RS C CAC NI011567 02-R1�pdf
Approved for use a HZ:Yes Quality Assurance Contract Expiration Date
Impact Resista :Yes 04/30/2017
Design Pressu e:+50/-60 Installation Instructions
Other:Miami-Da or Quanex FL14095 R5 II DP50-60 52 125x75 Impact Installation Instructions pdf
Building Products,Inc PVC(12-1017.02 and FL14095 R5 II DP50-
13-0425.15).Miami-Dade NOAs for Dupont 60 52.125x75 Wood Through Frame'JImpact Installation Instructionspdf
SentryGlas(11-0624.02)and Butacite PVB Verified By: Hermes Norero,PE 73778'
(13-0129.27)Interlayers.IG back bedded Created by Independent Third Party:Yes
with Dow 995.Windows with insulated glass Evaluation Reports
units wider than 36"require setting blocks. FL14095 R5 AE PER3091.odf
Created by Independent Third Party:Yes
1
14095.5 Premium Atlantic Vinyl Single Hung(8100)52 1/8"'x 75"Insulated Glass(5/16 in SGP Lam-3/16
out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 RS C CAC NI011567-NI011I567 01 odf
httDs://floridabuilding.org/nr/nr a.nn dtl.aSnx?naram=wCTF.VXOwtT)nt0T.R0/n7.hvC..Rv17k 4/?Q/?()16
r-1-��. NAIL FIN INSTALLATION
CORNERS 11/2°MIN.EMBEDMENT
t 2 2X WOOD FRAME
YIDSPAN MIN.DISTANCE
Of MIN.DISTANCE
FOR EDGE:3/4a FOR EDGE:3/4"
18.75'O.C.
NAI.TNRU 3 2X WOOD
SHIM
NAIL FINMAX 3
SHIM SPACE FRAME
22mm
-42mm 2 1/4"MAX
,3 3mm 3mm SHIM SPACE
9 11/2"MIN. O
° EMBEDMENT
fl
- —_ -- —
Em
_. 13.6mm-
g
aQ�
= I
VC
GLAZING DETAIL - - - - - -
FRAME SECTION(TYP) JAMB SECTION(TYP)
VERTICAL SECTION HORIZONTAL SECTION
NOTE:Cmdk6cnrcm NNling FWigc d Wand Opuung. NOTE:Caulk helween Nailing Flmge 8 Waod Opening.
1/4"MM SHIM
MAX
/�" SHIM SPACE 3
YIDSPAN mom MIN.DISTANCE
��RN FOR EDGE:3/4° PREMIUM ATLANTIC VINYL SH WINDOW
2 2X WOOD FRAME Max Frame I DP RATING IMPACT
WINDOW WIDTN(82 1/8'YAX.I 11/2°MIN.EMBEDMENT 52 1/8 x 75 1 +50/-60 1 YES
TYPICAL ELEVATION WITH FASTENER SPACING LARGE MISSILE IMPACT
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use#10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
1/2"into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by
project of installation. DuPont-3mm annealed.
Digitally signed by Hermes F.Norero,P.E. 4. Use structural or composite shims where required.
Reason:I am approving this document
Date:2014.09.19 16:25:32-04'00'
This schedule addresses only the fasteners required to anchor the 9®1 7 t AOB�
window to achieve the rated design pressure up to the size limitations
AN
noted. It is not intended as a guide to the installation process and does �m ie PROJECT ENGINEER: DATE:
not address he sealing consideration that may arise in different wall ewe Q` •a••"•• �F ®�� -- 08/13/2014 3737 Lakeport Blvd
% JELDVEN
conditions. For the complete installation procedure,see the instructions : ��,°�,� .�� i DRAWN BY: SCALE: Klamath Falls,OR.97601
packaged with the window or go too O 7 D.Vezo NTS Phone; (541)882-3451
eld-wen.com/resources/installation. ® CHECKED BY: TITLE:
www.jeld-wen.com/resources/i�nstallation.
J. Kantola
L APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window
DISCLAIMER:
This drawing and its contents are confidential and are not to be m�0,�•••.• O OP;•' ���� PART PROJECT No.:
reproduced or copied in whole or in part or used or disclosed to others Bio P E ��e® D608729
except as authorized by JELD-WEN Inc.
398 s D 61@p�Fi �i� Ee 338 INL21O'3H74- FBCNAME AND LOCATION: CAD DWG.No.: REV: 00 SHEET 1 OF 3