HomeMy WebLinkAboutProduct Approval m `® � 8 � ® n 0 ® � A �• G _
Florida alpavant! SCIS Home f Log In User Registration Hot Topics Submit Surcharge i Stats&Facts j Publications f FBC Staff BCIS Site Map j Links l Search
Busines (
Product Approval
SuuliccUser
Regulation
Product Aooroval Menu>Product or Aoolication Search>Aoolication List>Application Detail
FL# FL10674-R1 l
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Gl Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R11 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
i
Product Approval Method Method 1 Option D
Date Submitted 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/20/2015
Date Approved 12/15/2015
Date Revised 04/18/2016
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R11 II 2015 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R11.odf
Impact Resistant:N/A Verified By:Robert J.M.Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R11.odf
Created by Independent Third Party:Yes
Back Ne#
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850487-1824
The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-rewrds request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275
(1),Florida Statutes,effective Ober 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
secu ri t 1'.N Iir It i QS*
t
`4 EXTERIOR RESEARCH&DESIGN,'LLC.
r' %d
Certiftate of Authorization#9503
STREETUNIT#13
,,' TRINITY�ER® 353 CHRISTIANOXFORD,,CT 06478
G PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R6
One Owens Corning Parkway FL10674-R11
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 6: 10/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT- The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by: ti;ttrrrr,. —
"%��• • The facsimile sealappearingwas authorized Robert Nieminen,
Robertl.M.Nieminen,P.E. /e'yV1�j��♦L���•`�. P.E.on10/15/2015This does not serve asanelectroni:allysigned
:'A,bgnrr��•'
Florida Registration No.59166,Florida DCAANE1983 document.Signed,seated hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,R.E.does not have,nor will acquire,a financial interest in any other entity_ involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen,P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
-,ITRINITY!ER®
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard. Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Entitv Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'"'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition' Duration', Duration" Premium Cool, TruDefinition Duration' Designer Color
Collection,TruDefinition*Oakridge', Oakridge and WeatherGuard'HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard� HP Hip & Ridge
Shingles,ProEdge Hip&Ridge Shingles and Dura Ridge'""Hip&Ridge Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any.project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-116
Certificate of Authorization#9503 FL10674-RII
Revision 6:10/15/2015
Page 2 of 7
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for
us in all wind zones up to Vasd=150 mph(Vkdt= 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasd= 150 mph (Valt= 194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
D Berkshire shingles require minimum five(5)nails per shingle.
t WeatherGuarda HP shingles require minimum six(6)nails per shingle.
r DevonshireT"'shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Pius:
Felt underla ent —Deck Deck W-adhered
ym Fehuaderhyment fi Weathertock&
"L Self-adhered ?G undedaymeat
�%% NleatherLockn •''!
(uty underlayment �.
Drip—, Dnp edge
edge �q r/Drip edge Drip-- ;
edge
Nails located Nals located
2—3'tmm eave
2-r tram eave
Install first Self-sealing adhesive Self-sealing adhesive
Starter Strip wits!first Starter Strip Plrs
shingle with Positioned along eave positonedalongeave
\ with6-removed •
6"removed Starter Strip shingle overhangs eaves and rakes Yr=}k^ Starter Stip Plus overhangs eaves and rakes 1W-314"
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6
CerfWcvte of Authorizotion#9503 FL10674•Rll
Revision 6:10/15/2015
Page 3 of 7
\,,.J TRINrryER®
6.2.6 Minimum Nailing—Classic°&Supreme:
Normal Mansard or Area para Normal Mansard or Area pare
Wind Areas High Wind desvones y Wind Areas High Wind dasv&nes y
Ama para vientos normales Areas viontos fuorres Area para viontoa normal&& Areas vientos fuertas
r n" (A) sr1q (t" z"' 16) r s Z siz t (A) �12y t"� fit" t"11
5"Exposure 5 5/8"Exposure
Exposieidn Exposieidn
6.2.7 Minimum Nailing—Berkshire®:
Sealant strip Sealantstrip
La t8a do soRM& La Ika do mlkdor
�t—►•�—s • t—s •e--t.•
04 064— -0.• ----•
t" 8 Vx' 9 VP 9 YP R h" } L 8 N 87/P A I, ",I, 1
ir t" J
t
t
T' Asphaft rooRngeemeni
Conanto do ttchoda astatto
6.2.8 Minimum Nailing—Devonshire'"':
i Nails
I 4 �4v :� f.•:
Nails Ten 1"Spots of Asphah Roof Cement
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116
Certificate cl Authorization 89503 FL10674-R11
Revision 6:10/15/2015
Page 4 of 7
1
6.2.9 Minimum Nailing — Duration", TruDefinition" Duration, Duration° Premium Cool & TruDefinition'
Duration'Designer Color Collection:
4 Nail Pattem 6 Nay 9h sartam35fe.p SU
S1sUU Mreeen Stlt<Y.tn
Esquema do 4 davos Pattern arraandrro dtato�.
Esquema erb apxdsc
sure"393tWeningareawRilh do6davos Pc4afnrmlat ed
Arta de dim;SwetlaaD • • • 1 75meN1?gmlxt:
'y er errc4Y rsaU.
SUn1aYa \ Sle'X:{Y�
11• Ci�:rN � ,Mxli
arcain nawt�n
tbr74
17.
59a"Exposure Naas 5$b'B(pasure
95 pulp.de exposicidn pavos S-Apufg.de exposfefdn
M .Exposure Naas SA Exposure
SSSpulg.deerposkldn Clavas 5%pufg.deexposiddri
a
6.2.10 Minimum Nailing—TruDefinition Oakridge",Oakridge":
4 Nail Pattern 6 Nail Pattern
Esqueina con 6 clavos. Esquerra con 6 clavos
r r
r r
IE— 1r —>I lt— 1c—>►I 17"
A -,
5518"Exposure flails 5 5W Exposure Nails
Exposid6vde66/Bp+dg• clavas Exposfddade6618pufg. 55f8'Exposuie clavos 55f8 Exposure
Exposiddn de 66/8 pulg Exposfd"vn de 66/8 ping.
6.2.11 Minimum Nailing—WeatherGuAW11 HP:
no ado View
Ciww•w 1•list dr f;slh
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,WeatherGuard'HP
Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current.
published instructions, using four(4) nails per shingle. Installation of DuraRidge'm Hip & Ridge Shingles
shall comply with the manufacturer's current published instructions,using two(2) nails per shingle. Refer
to Owens Corning published information on wind resistance and installation limitations,including the use
of hand-sealing for wind warranties.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate of Authodration 119503 F L10674-R11
Revision 6:10/15/2015
Page 5 of 7
j ER®
�.�TRINITY
I
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire°Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
t-- Difwlinq bllntl �^ +i
Oireabn \ IUP�ew S4foNc�
Haiti-------�—)4 \ \\A\ i Mals tails
top Lanftm Z•�,
Pi¢e
\A \ .o i ,•
Expos e
\ r it >�
6.3.4 Minimum Nailing—Hip&Ridge with Sealant:
em Fig. 2 High Wind Fastening ft"em
(4 Nails)
rim Shingle—+�
nd Mmard 2„
Excess ,Il,
Sealant -1
Strip F 12"
'Fastening 5%11 V Exposure
Distance i
44 12 ,x.
6.3.5 Minimum Nailing—WeatherGuard"HP Hip and Ridge:
Fig.C Hip&-Ridge Shingle Fastening.
Fig.A ropVL,W
vRwagingtrl� �\
MRS Uts
7'
s/4� I 1 � � 1•� I 1•
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate of Authorization il9503 FL10674-R11
Revision 6:10/15/2035
Page 6 of.7
''-1!TR1N1-rY ERD
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard
Wind Direction Sealant Strip Fastening
Pattern
Z°.
A-` V Exposure
t2' 1 Sealant
Fasten 7'h' I 11h, 6'Exposure
Cover Exposed li
Fasteners with
Roof Cement
6.3.7 Minimum Nailing—DuraRidgel" Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens
Corning published installation instructions for their minimum requirements.
e--FYasaJtng Wind Diradcn vue en'p4n
Diroai21.imnc.drvmc 11- Viswsup_riw I'I
Dirocdondol rimodor
in prniranca
4-ti � Nail
CA
l
\`\ 2/i � OVRn3Can(rn95um1J3,7' �.� C:u+o
1
I
I
alae
efiLya U Inc
I A.
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409; karen.buchmann@ul.com
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 637940.02.12-R6
Cenifimte of Authorization 49503 FL10674-R11
Revision 6:10/15/2015
Page 7 of 7
S `
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
` 353 CHRISTIAN STREET,UNIT#13
111. 1 ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Soprema,Inc. Evaluation ReportS18010.06.09-R9
1640 rue Haggerty FL2569-R1i
Drummondville,Quebec J2C 5P8 Date of Issuance:06/15/2009
Canada Revision 9: 10/12/2015
SCOPE:
This Evaluation Report is issued under Rule'61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5`h Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION:. Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This,Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire.Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
ttirn!crr,, --
Robertl.M.Nieminen,P.E. . .r-, T.E.on im3-2/20 5,Thisngwaztserve
asanelebyRoberticaiiOen,
g 'c,'S•r^ Wit.%�.•`�,•- document.Signed,seated haarrdwt les have been t nsm'itted oothe
Florida Re Registration No.59166,Florida DCAANE1983 � s P
.d....... rtr Product Approval Administrator and to the named cEent
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,.a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E..are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
Y
.' TRINITY ER®
ROOFING COMPONENT EVALUATION:
2. SCOPE:
Product Category: Roofing
Sub-Category: U nderlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8, Physical Properties ASTM D1970 2009
1507.2.9.2,1507.4.5.1,
1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TAS 110 2000
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Kafty Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 'S13190.02.09-111 04/01/2010
ERD(T5T6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 S40540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two.widths; 36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
Exterior Research and Design,LLC. Evaluation Report 538030.06.09-R9
Certificate of Authorization 119503 FL2569-Rll
Revision 9:10/12/2015
Page 2 of 7
t� -
TRINITYIRD
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.6 Lastobond Pro HT-S is a self-adhering,'woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.8 Lastobond is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.16 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen
roof underlayment.
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment,with a 36-inch sheet width.
4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width.
4.13 RESISTO LB1244 is a self-adhering, giass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment,with a 44-inch sheet width.
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
4.15 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. if not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE 1: ROOF COVER OPTIONS
Asphalt Nail-On Foam-On Metal Wood Shakes& Slate
Underlayment Shingles Tile Tile Shingles
Lastobond TU HT Yes Yes See es Yes Yes Yes
5.Lastobond Shield/Pro HT-N/ yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Lastobond/Lastobond 195 Yes No No No Yes Yes
Exterior Research and Design,LLC. Evaluation Report 538010.06.09-R9
Certificate of Authorization#9503 FL2569-R11
Revision 9:10/12/2015
Page 3 of 7
3 `
' TRINITY ER®
TABLE 1: ROOF COVER OPTIONS
Asphalt Nail-On Foam-On Metal Wood Shakes& Slate
Underlayment Shingles Tile Tile Shingles
Lastobond ECO /RESISTO
LB1236,Grip-Rite Eave&Valley Yes No No No Yes Yes
Protector/RESISTO LB1244
Lastobond Smooth Seal HT qe No No Yes Yes Yes
Colphene FR GR Yes Yes No Yes Yes
See S.5.1
Unilay(e) Yes Yes No No No
Batten Only See 5.5.1
5.5.1 "Foam-On Tile"is limited to use of the following adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond"°Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
i Plywood;ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
'r Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
S While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR applied to:
➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on the systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-119
Certificate of Authorization#9503 FL2569-Rll
Revision 9:10/12/2015
Page 4 of 7
TRINITY ERD
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector, RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR applied to:
r ASTM D226,Type I or II felt;Sopra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on the applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocol Stick or Elastocol 600c
Underlayment: Lastobond TU HTor Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps(FBC-1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c. in three,equally
spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.4 Maximum Design Pressure=-90.0 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PBB) or Soprafix
Metal Batten Bar(MBB)with Soprema#15-EL fasteners spaced 6-inch o.c.within the 5-
inch wide, self-adhering side laps. End laps are 6-inch wide and sealed using either
heat-welding or hot-air welding techniques.
5.7 Exposure Limitations:
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave &
Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer than 180-days after
installation.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R9
Certificate of Authorization 119503 FL2569-1111
Revision 9:10/12/2015
Page 5 of 7
6 9``
TRINITY?ER®
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or
Elastocol 600c(if applicable).
6.3 Lastobond TU HT Lastobond Shield Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40 Lastobond Shield
HT.Lastobond Pro HT-S,Lastobond,Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT,RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final
roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile_Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications,reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
6_4 Unila e:
6.4.1 Non-Tile Applications or Nail-On,Battened Tile Applications:-
Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if applicable).
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope,
mechanically attach the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-
nails spaced 36-inch o.c. Apply the second course in a water-shedding manner with self-adhering side-
laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight
application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course
below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R9
Certificate of Authorization 49503 FUS69•1111
Revision 9:10/12/2015
Page 6 of 7.
TRINITY 1 ER®
Tile(if applicable)shall be loaded and staged in a manner that prevents the slippage avid/or damage to the
underlayment.
6.4.2 Foam-On Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual,Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and,.starting at the eave with the selvedge-edge upslope,
mechanically attach the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar(PBB)or
Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second
course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to.the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course
below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entityfor information on plants covered under Rule 61G20-3 QA
requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R9
Ceztficate of Authorization#9503 FL2569-R11
Revision 9:10/1212015
Page 7 of 7