Loading...
HomeMy WebLinkAboutProduct Approval I From: 05/02/2096 07:55 #042 P.001/007 f EXTERIOR RESEARCH&DESIGN, LLC. t � i Certificate of Authorization#9503 ® 353 CHRISTIAN STREET,UNIT#13 -{ TRpe 8[�'�I�i Efe®s OXFORD,CT 06478 PHONE:(203)262-9245 EVALUATION REPORT FAX:(203)262-9243 Owens Corning Evaluation Report 037940.02.12-R6 One Owens Coming Parkway FL10674-RII Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 6: 10/15/2015 SCOPE: i This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed,by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CoNTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. j ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M.Nieminen,P.E. The facsimile seal appearingwas authorixedby Robert Nieminen, •���!��al. �d'� P.E.on 10/15/2015.(This does not serve as an electronically signed Florida Registration No.59166,Florida DCAANE1983 document,signed,seated hardcoples have been transmitted to the CERTIFICATION OF INDEPENDENCE: ' Product Approval Administrator and to the named client 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in Jany company manufacturing or distributing products it evaluates. I 2. Trinity(ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company,manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financlal interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen,P.E.are, in any way;the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting orl'design guidance unless retained specifically for that purpose. I i 05/02/2.016 07185 #042 P.002/007 From: TRINITY IRD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement- Owens Coming Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the Florida Building Code and Florida BuildinIg Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prom Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: ErWtv Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-82453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4796093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) F8C HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2451, Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic*and Supreme*are fiberglass reinforced,3-tab asphalt roof shingles, 4.1.2 Berkshire*are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshirel" are fiberglass reinforced,5-tab asphalt roof shingles. 4,1.4 Durations, TruDefinition* Durations, Duration' Premium Cool, TruDefinition Durationo Designer Color Collection,TruDefinition'Oakridgeo,Oakridge'and WeatherGuard HP are fiberglass reinforced,laminated asphalt roof shingles. 1 4.2 Berkshires Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard HP Hip & Ridge Shingles,ProEdge Hip&Ridge Shingles and DuraRldgelm Hip&Ridge Shinglesiare fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. WITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification Is not part of this Evaluation Report; refer to, current EApproved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RG Cerilfkate ofAuthodiaffan#9503 i FU0674-RII Revision 6:10/15/2015 Page 2 of 7 ............ I From: 05/02/2016 07:66. #042 P.003/007 TR8Ni1 ER® 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with!FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to V,,d=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter'.Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R90S.2.6.1 to ASTM D3161,Class F, indicating the les are acceptable for us in all wind zones u to V I' shingles P p ,:<t= 150 mph (V„It= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordince with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61620-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 installation of asphalt shingles shall comply with the manufacturer's cur rentpublished instructions, using minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: D Berkshire shingles require minimum five(5)nails per shingle. D WeatherGuarda HP shingles require minimum six(6)nails per shingle. D Devonshire'shingles require minimum six(6)nails per shingle: ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails i'per strip. Refer to Owens Coming published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or 8905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlaymeat —Deck Feb undeitvynieinI Deck Self-adhered-�•". Self-adhered undodayment WeatherLocka 'i WeatherLoWE �( underlayment d Drip_ Drip edge Drip.— Drip edge_ edge edge ..�'. Nails locatedNark located 2=3"from eave eave Install first Sell•sealin adhesive Sd(aeding edhos ve Starter Strip Install first Starter Strip PArs asition along eave wth6 removed__..- „ ,•'\ I, pasitionedalongcan shingle with ••, P g � 6"removed Starter Strip shingle overhangs eaves and rakes 4i'-?!i" Starter Strip Plus overhangs eaves and rakes 1/4-_314' b Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6 CerHJlmteoJAuthorlrar;onp93o3 I FL10674-R11 Revision 6:10/15/2015 Page 3 of 7 L f 05/02/2016 07:57 #042 P.004/OO7 From: ~1 TR INIT ' ERCP I _ 6.2.6 Minimum Nailing Classic®&Supreme: NorrrfoF Mensard or Area pore Norman A ons"or Area par* Wind Areas High Wind desvenes Y Wind Anes High Wind desvenas y Area tare vlentoo norma les A= v/orrtoe fuertes Arses pats vientos normetes Anae vlentos fuartas z•, 18 z' t. t ,_.�fAi� r r .2, (Bf z• r a12 S"Exposure S SW Exposure Expoatcldn Fxposicldn 6.2.7 Minimum Nailing—Berkshire": Sdabin strip Sealdl stdp LatbadorWada to t6 idoidladu f -�-!•4r-�► i E—�1 •t-��'!i if-��►i�f i e t---�-1 a�-�«+-iia t ow 3 Yr 9 Yf t#17 t � s Yt 8 of a'If 8!f r r. 2" AsphaRroot6ag cemoni Cement#ak techode a!tdN Q 6.2.8 Minimum Nailing—Devonshire'": s, �� •r--- �� Nails tt Y Nails Ten 1"Spots of Asphalt Roof Cement �4 d � �I � 1 Exterior Research and Design,LLC. I� Etaafuation Report O37940.02.12-RS Cerelfiante of Authorhatlon IISS03 FL10674-R11 Revision 6:10/1S/2D1s Page 4 of 7 ,i ` _— Hip_Ridge Shingles: From: 05/02/2016 0, i7:58 0042 P.006/007 J TRINITYI ERD 6.3.2 Fasteners shall be in accordance with the manufacturer's ublished require pi ants, but not less than FBC 1507.2.6 or R905,2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: ;I Fig.7 ;;-\� y�, Fig.2 p �— PmvdfmOWne /� xnm®n rj �., \�\,n� TapWaa • 5ldelflory WKS ---_._— , r TDP Lalinelal + Place ir \ i I I fxiwsure _ T� 1 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: em fig.2- ig r WkW Fastening Patwm K Nails rim Shing ie—+ nd Discard 2., 2" Excess ��� +� Sealant -----# Strip i� 12" I ' Fastening 5'/e" S"Exposure Distance 12 6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge: i Fig.C Hip&Ridge Shingle Fasteniing Fig.A DroVas rand `�.——4 4� — 70p Vkw '�j` \•� .o'. I i F.. Nails i iV. EVOSUM � • .. ESPOLUfe +r' i Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6 Certificate of Authorization#9503 EL10674 R11 Revision 6:10/15/2015 Page 6 of 7 �•..• m M M. r ............... From: 05/02/2016 0 1 7:59 ;F042 P.007/007 :ERD TRINITY : 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind Direction Sebryt Strip Fastening Pattern 6'Exposure 2-1 r r Sealant ................... Fmon 71W 7% I t 6"Exposure Coll Mt Roof Content 6.3.7 Minimum Nailing—DuraRidgel Hip&Ridge Shingles: "Wrements. Refer to Owens Note: The drawings below pertain to minimum, as-tested attachment req Corning published installation instructions for their minimum requirements. T. VM cf. CA— MA 2 Ve' Sib, Va v 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted 7.2 herein. ii Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order ly evaluate the installation of this product. 9. MANuFAcrURING PLANTS: Contact the named QA entity for information on which plants produce pro�lucts cov,&ed by Florida Rule 9N-3 OA requirements. 10. "QUALrryAssURANCEENTrry; ULLLC—QUA9625;(414)248-6409;karen.buchmann@ul.com END OF EVALUATION REPORT- Exterior Research and Design,ILLC. valuation Report 037940.02.12-R6 Certifkate afAuthorization M03 FL10674-RII Revision 6:10/IS/202S Page 7 of 7 7-