td2D12 t�uctureslntemaltot�aE LLG �' '� a -;Conforms withA5CE730
DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING
Design Data Building Data
Wind Velocity(mph) 160 Mean Roof Height 12
Risk Category 2 Building Width(ft) 95
Exposure Category D Building Length(ft) 36
Directionality Factor 0.85 Roof Slope (x:12) 3
Internal Pressure Coefficient+/- 0.18
Design pressures listed below are: Allowable Stress
OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE
MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF)
1,2,3 3 AC 86-DH's Mulled 4 5 110 49 37.1 -40.6
4&5 2 AC 86-DH's Mulled 5 5 73 49 38.2 -49.6
6 AC 86-DH 5 5 36 49 40.1 -53.3
7 AC 12-SH 4 5 18 37 40.6 -44.1
8 AC 12-SH 4 5 18 37 40.6 -44.1
9 AC 86-DH 4 5 36 49 40.1 -43.5
10 AC 86-DH 5 5 36 49 40.1 -53.3
11 AC 86-DH 5 5 36 49 40.1 -53.3
12&13 2 AC 86-DH's Mulled 4 5 73 49 38.2 -41.7
14,15,16 3 AC 86-DH's Mulled 5 5 110 62 36.5 -46.2
17 AC 86-DH 4 5 36 37 40.6 -44.1
18 AC 86-DH 4 5 36 37 40.6 -44.1
Width of End Zone(a)in feet= 3.6
5 h RECEIVED
s 5 MAY 0 2 1016
PER:JIITTINC
Si. Lucie County, FL
I L P- Y
STRUCTURES INTERNATIONAL,LLC
..Pamszlang StmEds S�+G.^st3 fis i"X','3x�sY I tt C4Frr�`
4/27/201612:42 PM
Jack Miller,#9180898
12951 S Indian River Dr.
Jensen Beach, FL 34957
Replacing 18 windows size for size(16 impact&2 non-impact).
Homeowner has existing storm panels for the 2 non-impact windows.
The cost of the job is 7.1% of the structures' assessed value.