HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC.
806 Delaware Avenue,Fort Pierce, Florida 34950
PHONE(772)460-7751 FAX(772)460,4244
EMAIL cookmenard@yahoo.com
May 2, 2016 FILE Copy
Saint Lucie County Building Department
Attn: Roof Permit Plan Review RECEIVED MAY 0 5 2016
2300 Virginia Avenue -
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the Fort Pierce Building Dept.for the structure located at, 703
W. Weatherbee Rd. Fort Pierce, Florida
Manufacturer: CertainTeed Corporation-Roofing
Profiles: Flintastic Modified Bitumen Roof System, FL#2533.1
Code: FBC 2014;Section, 1504.3.2, 1504.7
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: B
Mean Roof Height: 20' Maximum
Pitch- Y4-/12
Required Design Pressure: Zone 1: -42.1 Zone 2:-50 Zone3: -88.5
Maximum Uplift Pressure: Zone 1: -52.5 psf, Zone 2-52.5 psf, Zone 3 -90
Fasteners: Zone 1&Zone 2-Simplex Maxx Cap @ 9" o.c. at 2-inch lap and 12"o.c. in two,
equally spaced,staggered center rows
Zone 3-Simplex Maxx Cap @ 6"o.c. at 2-inch lap and 6" o.c. in two, equally
spaced,staggered center rows
Underlayment: One ply of Glasbase; Flexiglas, Flintastic Base 20;All Weather/Empire Base; Poly
SMS Base,Yosemite mechanically fastened
Membrane: One ply of SBS-AA,SBS-TA or APP-TA torch adhered to base/ply sheet
The above approved, as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the
manufacturer's recommendations.
ktfolly"Submitted,
lac
Peter&�Cob
.'Architecture, Inc.
Florida Registration No. AA0003494, NCARB Certification No. 31789