HomeMy WebLinkAboutProduct Approval 1/8/2016 Florida Building Code Online
i
RECE1VED MAY5 � q
i
a � l - -
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links Search
BusinesC
,
ffi Product Approval
USER:Public UserProfessi8'nal
... v P
ProdU&Approval M-e a.Product pr Aonucatton SearchD � � `>Application Detail
FL# FL10674-Rll
Application Type Revision
Code Version c2014=�
Application Status Approved
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Coming Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email j_j ns_Coming PKWY
°Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Ash:phalt=Shingles��..---
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Nam who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL10674 R11 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2p08
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
http:llwmnufloridabuilding.org/pr/pr app d8.asp)(?pararrr=wGEVXQvADgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6i)EAOdgbUj3osQ%3d0/o3d 1/2
118/2016 Florida Building Code Online
Date Submitted 10/1512015
Date Validated 10/19/2015
Date Pending FBC Approval 10/20/2015
Date Approved 12/15/2015
Summary of Products
'FL#
Model,Number or Name Description
10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab, 5-tab,laminated,starter and hip&ridge shingles
Shingles and Starters
Limits of Use I Installation Instructions
Approved for use in HVHZ: No FL10674 R11 11 2015 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R11.Dd
Impact Resistant: N/A Verified By: Robert 1. M. Nierninen PE- 59166
Design Pressure:N/A Created by Independent Third Party: Yes
Other:Refer to ER, Section 5. Evaluation Reports
FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT
SHINGLES FL10674-RI Lod
Created by Independent Third Party:Yes
Contact us 1940 North Monroe street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility statement::Refund statement
Under Florida law,email addresses are public records.If you do not vent youre-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter455,F.S.must provide the Department with an email address if
they have one.The emajis provided may be used for official communication with the licensee.However email addresses are public record.If you do not Wsb to
supply a personal address,please provide the Department with an email address vAilch can be made available to the public.To determine if you are a licensee
under Chapter 455,F.S.,please click here
Product Approval Accepts;
OU Fc-P EH M
hdp://vwm.floridabuilding.org/pr/pr-fipp A.aspx?param--mGE\IXQvADqtBNbEYSV%2boQT%2b6w7ahReglCQ8ucR6i)EAOdgbdJi3osQ%3d%3d 212
Cz,
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section PropertV Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'" are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration', TruDefinition' Duration', Duration' Premium Cool, TruDefinition' Duration' Designer Color
Collection,TruDefinition'Oakridge,Oakridge and WeatherGuard'HP are fiberglass reinforced, laminated"
asphalt roof shingles.
4.2 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge
Shingles, ProEdge Hip &Ridge Shingles and DuraRidgeTm Hip&Ridge Shingles are fiberglass reinforced, hip
and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R6
Certificate of Authorization#9503 FL10674-Rll
Revision 6:10/1512015
Page 2 of 7
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for
us in all wind zones up to Vasd=150 mph (V„lt= 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasd= 150 mph (V,,lt= 194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire shingles require minimum five(5) nails per shingle.
➢ WeatherGuard'HP shingles require minimum six(6)nails per shingle.
➢ Devonshire'"shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC"
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlaynient Dora Felt underlayment -!��, Deck Selfadhered
4YeatherLecki.
=• 5211-adher?d '_. underlaymcni
Drip edge
Drilr� Drip edge Drip—.
edge q;. edge
_ Naits located
--Nails located -2--3-from cave
2'-3"from ex
Selfaealing adhesive
IDstallfirst / S21f•s2alingadhesive Instal]first Starter Strip Plus positioned along cave
Y iter Siri r posdicdred along eave I with 6 removed — ---
Shingle%'.-flit \ \
6"removed Stoner Strip Plus overhangs eaves and rakes 1y4'-3l4'
Starter Strip shingle overhangs eaves and rakes
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6
Certificate of Authorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 3 of 7
6.2.6 Minimum Nailing—Classic'&Supreme:
Normal Mansard or Aroa para Normal Mansard or Area para
Wind Areas High Wind desvanes y Wind Areas High Wind desvanes y
Area para vientos normales Areas vientos fuertes Area para vientos normales Areas vientos fuertes
ri„ z'Z lBl `z. t" ��,. (A} !'Z `t. z.Z IBIS rz. t.
.—ir it ni i t27
5"Exposure 5 5!B"Exposure
Exposicidn Exposition
6.2.7 Minimum Nailing—Berkshire®:
Sear m Drip Sealant strip
La lira rla taBador La tva de xdtador
�&t--!ee� -9 ® 4---i a f—i• of--- ----------a -- 0 e •a ` .'0
R''d' 9 Vy' :1 VP R 9<" R
B
e -
` \ Asphalt roofing cemeni
cemento de!""de 64aho
6.2.8 Minimum Nailing—Devonshire':
i Nails
� z
Nails Ten t"Spots of Asphalt Roof Cement
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate ojAuthorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 4 of 7
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition�
Duration'Designer Color Collection:
4 Nail Pattern 6 Nail ��;:.r.a.;:c..nuraia il
Eaquema de 4 clavos PatternEs "en3
u1•"•
SU*TbiPbSteningarwwidth de6clavos _-v
Area declatosSureNail' • • • "",r.hM1;.',
�Is..i
12" —s <— 12'—x► FIJJe 1" �T
d3ws
dn!�
t
LE
59e'Exposurej
5`6`Expo ure
1
Nails
r. ping.de exposition Cfavas SS;pufn.de exposition
"Exp!eur•� Naik 5'c'Exprsure
5i;Pufg,de expos"rbin Cfav!K 5f"lung.de ogh)sida"n
6.2.10 Minimum Nailing—Tru Definition'Oakridge®,Oakridge®:
4 Nail Pattern 6 Nail Pattern
Esquema con 4 clavus Esquema torr 6 clavos
r r
r r
12'�l
lam— 12" 12"
5 518"Exposure
Nails 5 518"Expo-,uNails
s 5 518"ExPoFiPosid&r de 55/8 uig. Clauos Ex osfcion de 5 S/6 pulg. 558Exposure Clav
Exposicln
e
de 65/8pula. Exposiclon de 55/6pula.
6.2.11 Minimum Nailing—WeatherGuard'HP:
11-1 no 0 51111119 WOW
risterwr7Frnrgltl Ndl Lltar
Cia..w e.Ks.. i+Me{ie
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire'Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,WeatherGuard®HP
Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles
shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer
to Owens Corning published information on wind resistance and installation limitations, including the use
of hand-sealing for wind warranties.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate of Authorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 5 of 7
'
6-3z Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FB[
15072.6orR905.2S. Staples are not permitted.
83.3 Minimum Nailing—8erkshireOHip&Ridge and High Ridge:
7.
6.3.4 Minimum Nailing—Hip&Ridge with Sealant:
f4 Nails)
Strip 12"
12
6.3.5 Minimum Nailing—VVcatherGward'DHPHip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A
TOPVkW
VOnd
NUS
Expasum
Exterior Research and Design,I.I.c ' Evaluation Report oa7y 0.0212-w6
o,tifiate«yAuthorization msm FL10674-nll
Revision s'10Y1s/2ozs
Page oofr
^
,
�3.6 Minimum Nailing PmEdgeHip&Ridge Shingles:
7revaifinu Standard
!Wnd Di - Fastening
YeCtIo" -- allant Strip Pattern
Sealant
711j"
Fasten 71jV 6"'Exposure
Cover Imposed
Fasten.wit
63J Minimum Nailing—DuraRXdge" Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, a,-tested attachment requirements. Refer to Owen,
Corning published installation instructions for their minimum requirements.
Top vl
Ch
2 VC
Sam
ri,-NASi L
7' LABELING:
71 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507z.7.1/nso5.z.61
Q' BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named CIA entity for information on which plants produce products covered by Florida Rule 9N'3 QA
requirements.
lQ' QUALITY ASSURANCE ENTITY:
U_L LLC—QWx9625;(414)248'6409;
- END OFEVALUATION REPORT'
Exterior Research and Design,LLC. Evaluation Report uyno«v.oz.z2-xo
puoor+nz�
u,w�"*�A"m"�"�"v��
Revision 6:10/15/2015
Page zmrr