HomeMy WebLinkAboutProduct Approval COATING
MIAMI, MIAMI-DADE COUNTY
• PRODUCT CONTROL SECTION
H 805 SW 26 Sti•ect,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33 175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.lov/economy
LAPOLLA Industries,Inc.
15402 Vantage Parkway East, Suite 322
Houston,TX 77032
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County
Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade
County) reserve the right to have this product or material tested for quality assurance purposes. If
this product or material fails to perform in the accepted manner, the manufacturer will incur the
expense of-such testing and the Al-IJ may immediately revolve, modify, or suspend the use of such
product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it
is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of rue Florida Building Code.
DESCRIPTION: : Therm-O-flex TF 1000 Series Elastomeric Roof Coating
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of due product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 1 1-0801.01 and consists of pages I through 3.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 12-0726.04
MIAMI•DADECOUNTY Expiration Date: 08/09/16
"'• ' �� Approval Date: 09/20/12
Page I of 3
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Cement-Adhesive-Coatings
Material: Elastomeric
SCOPE:
This approves "THERM-0-FLEX TF 1000 Series Elastomeric Roof Coating" as a maintenance roof
coating as manufactured by LAPOLLA Coatings, as described in this Notice of Acceptance, designed to
comply with the Florida Building Code, High Velocity Hurricanes Zone.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Underwriter Laboratories, Inc. R14353 UL 790 12/15/11
Factory Mutual Research Corp. 3023796 Class 4470 10/02/05
PRI Construction Materials LPII-013-02-01 ASTM D 6083 01/10/12
Technologies, LLC TT-C-555B
MANUFACTURING LOCATION:
1. Houston, TX.
PHYSICAL PROPERTIES OF COMPONENTS
Trade names: THERM-0-FLEX TF-1001(White), TF-1002(Grey),TF-1003(Tan)
Thickness: Wet Film per Coat : 24 mils
Dry Film per Coat : 13.2 mils
Specifications: ASTM D 6083
Description: A water-based elastomeric coating membrane applied at an application rate of,
• Galvanized Metal Roofs: Apply Base Coat at a rate of 1.5 to 2 gal/1.00 f12
and Finish Coat at a rate of 1.5 to 2 gal/]00 f12.
a SBS Modified Bitumen Granule Surfaced Membranes: Apply Base Coat at a
rate of 1.5 to 2 gal/100 f12 and Finish Coat at a rate of 1.5 to 2 gal/100 ft2.
a E.PDM Single Ply Membranes: Apply Base Coat at a rate of 1.5 to 2 gal/100
ft2 and Finish Coat at a rate of 1.5 to 2 gal/100 ft2.
S Spray Polyurethane Foam Roof Systems: Apply Base Coat at a rate of 1.5 to
2 gal/100 ft2 and Finish Coat at a rate of 1.5 to 2 gal/100 ft2.
• Concrete Decks: Apply Base Coat at a rate of 1.5 to 2 gal/100 f>2 and Finish
Coat at a rate of l.5 to 2 gal/100 .ft2.
Container Size: 5, 55 and 275 gallons. Note all precautions on container.
Systems Approvals: ]Methods of application and quantities shall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
NOA No.: 12-0726.04
MIAMI•DADECOUNTY Expiration Date: 08/09/16
"' 411Approval Date: 09/20/12
Page 2 of 3
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following.-
1.
ollowing:1. This Notice of Acceptance
2. Any other documents required by the building official or the Applicable Building Code in order to
properly evaluate the installation of this system.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire rating of this product.
2. THERM-O-FLEX TF 1000 Series Elastomeric Roof Coating shall not be applied in inclement
weather conditions.
�. The products listed herein are components of roof assemblies and are approved for use with roof
assemblies that list any of the products listed herein as part of their roof assemblies Notice of
Acceptance.
4. All products listed herein shall have an unannounced follow-up quality control program fi-om an
approved listing agency. Follow up test results shall be made available to Mianu-Dade Product
Control upon request.
5. Change in materials, use, or manufacture of any of the products listed herein shall be cause for
termination of this Notice of Acceptance.
6. THERM-0-FLEX TF 1.000 Series Elastomeric Roof Coating shall be used as a roof maintenance
coating system in accordance with applicable Building Code. THERM-O-FLEX TF 1000 Series
Elastomeric Roof Coating is not approved for use as a recover system.
7. THERM-0-FLEX TF 1000 Series Elastomeric Roof Coating shall be applied in accordance with
manufacturer's published application instructions.
8. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 9N-3 of the Florida Administrative Code.
9. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the
imprint or identifiable marking of the manufacturer's name or logo and following statement:
"Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal
as shown below
MIAMI•DADE COUPJTY
•e s
END OF THIS ACCEPTANCE
NOA No.: 12-0726.04
MiAMi•DADecouNTr Expiration Date: 08/09/1.6
Approval Date: 09/20/12
Page 3 of 3
SINCE The Treasure Coasts oldest
1970 applicator of G1 veled and
Members of FRSA& SPFA Coated foam roof systems.
P.O. Box 1908, Palm City, FL 34991
772-223-1215 phone, 283-5969 fax; CGC-003349; whitingconstruction.com; wci@whitingconstruo,tion.com
PROPOSAL SUBMITTED TO: Date: 4126/16. Phone: 286-4365, 341-3423 cell
Name: J. Griffin Development Inc. Job: Pelican Plaza/East building
Street: 1321 SE Riverside Drive Street: 10540 - 10558 USI
City: Stuart City: Port St. Lucie
State: FL 34996 Attn: Jim Griffin
We hereby submit specifications and estimates for: jimgriffinJ(:tpaol.com
RECOATING OF FLASHING AREAS ON WHITING SPF (Spray Polyurethane Foam) ROOF
SPF roof installed Dec. 2005
CONTRACTOR TO:
1) Pull gravel back from all flashing areas and parapet walls.
2) Pressure clean ail flashing areas and parapet walls.
3) Make any necessary minor repairs to all flashing areas and parapet walls.
4) Inspect the rest of the roof and make any necessary minor repairs.
5) Coat all flashing areas and parapet walls with an elastomeric coating.
6) Respread gravel as needed to assure proper coverage of the SPF roof.
ACCEPTING PARTY TO PROVIDE:
1) Water for pressure cleaning.
It has been 9 years since this Whiting SPF roof was installed. The roof is currently in good shape
with no apparent problems other than some areas of exposed SPF from aging of the coating on
the flashing areas. It is necessary to recoat the flashing areas approximately every 8 - 10 years to
prevent any deterioration of the SPF. Minor maintenance on a regular schedule is always more
cost effective than major repairs or replacement due to neglect.
A well maintained Graveled foam roof is sustainable and should remain in service indefinitely.
FIVE YEAR WARRANTY AGAINST LEAKS UPON FULL PAYMENT
Job value: $2,400.00.
Existing roof is a Whiting SPF roof system installed Dec 2005.
This is normal scheduled maintenance for a Whiting SPF roof.
Approx. 20 gallons of elastomeric coating will be used.