Loading...
HomeMy WebLinkAboutEngineering ECEIV770 MAY 10 7Oa6 PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -9888 Email pwelchinc@aol.com May.6,2016,2016 Re: Graff Re-Roof 10725 S. Ocean Drive Unit 228 Jensen Beach,FL 34957 SCOPE:OF WORK: Remove existing roofing and install new 5-V Crimp Metal Roof(Gulf Coast Supply& Manufacturing FL# 11651.13)at above referenced residence address over new underlayment and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT=9'-0" A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=3:12 SHAPE=PITCHED GABLE RVIPROTANCE FACTOR= 1.00 WIND VELOCITY V uit= 165 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=D ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (nsf): ZONE 1 (Field)=-44.7 ' ZONE 2(Perimeter/Ridge)_-75.5 _ _ \\,, ` 1�';�r i,�,fi✓ ZONE 3 (Corners)_-110.8tb > �r Paul-'Welch Inc. Pat l 4Velc_h P.E. Reg:No. 29945 - �, .'G '• _ � May 6,2016 10725 S.Ocean Drive Unit 228 Jensen Beach,FL 3.4957 :�' f ! '.�'� 1 of 3 ATTACHMENTREQUIREMENTS: Metal roofing to be attached with#9- 15 x 1 V2"long(minimum 1/4"penetration through plywood sheathing)Woodgrip screws with weather sealing washers spacing as follows: ALL FASTENERS IN THE FLAT OF THE PANEL ZONE I (Field): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 2 (Perimeter/Ridge): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 3 (Corners): Fasteners adjacent to ribs both side(Type 2 per product approval) at 16" O.C. Zones 1 &2 Design uplift Pressure: -94.25 psf Zone 3 Design uplift Pressure: - 131.0 psf Zones 1 &2: 94.25>75.5>44.7 Therefore O.K. Zone 3: 131.0> 110.8 Therefore O.K. NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. UNDERLAYMENT(oution#1): Underlayment shall be Polyglass USA, Inc.FL#5259.1 "Polystick TU Plus". Polystick TU Plus shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Section 1507. All seal-lap seams must be firmly rolled with a minimum 281b. hand roller to ensure full contact and adhesion. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4"O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL# 11651.13), (FL# 5259.1), manufacturer's specifications,and the Florida Building,.Codel2Q�4`% �` 01,G U^f� rrffl L �! .; Paiil-Welch Inc. Reg:No.29945 z _ Mav 6 2016 10725 S.Ocean Drive Unit 228 Jensen Beach,FL 34957 = ''!r,, .`r ,`� 2 of 3 r a 4j + or 10 I 's L OPE ' i v70,VQ I r • :: II ROOF ZONE PLAN A=3' ZONE DESIGNATION('TYPICAL) NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. -'-4i lfWelch Inc. = Paul Welch P.E.geg.No. 29945 - May 6-,2016 10725 S.Ocean Drive Unit 228 Jensen Beach,FL 34957 _ =� 3 of 3