Loading...
HomeMy WebLinkAboutInspection Docs (2) Apr 22 2016 2: 34PM HI '\- SERJET FAX P• 1 2300 Virginia Ave- Fort Pierce, FL 34982 772462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: SLC1604-0397 JOB ADDRESS: 102 Ddu Airoso Blvd. , Port St Lucie BUILDER/CONTRACTOR: Design Concrete. . PEST CONTROL CONTRACTOR: Patrick Exterminating PEST CONTROL LICENSE #: 4864 We, the undersigned, hereby certify that we have pretreated'the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: 360 Chemicals used: Cyper TG Percentage of solution: •25% Total gallons used: 36 Date of Treatment: 4/22/16 Time of Treatment: 1 :0 0 Footing Slab 1s'Treatment P Treatment Re-Treat Re Treat Driveway Pools 1st Treatment P Treatment Re-Treat , Re-Treat x Other. Patio' Perime r for'FnaI I•spection 1s`Treatment ,� J Re-Treat Signature of Exterminator Note.-There must be a completed form for each required treatment or re-treatment and this form must be on the job site.to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and are-inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites. A weatherresistantjobsite posting board shall be provided to receive duplicate Treatment Cenftatas as each required protective treatment is completed, providing a copy for the person the permit rs issued to and another copy For the building permit files. The Treatment Certlfrote shall provide the product used, identity of the applicator, time and date of the treatment, sfte location, area treated, chemical used,percent concentratfon and number ofgallorls used,-to establish a verifiable record of protective treatment: if the loll chemical barrier method for tennite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listingall the treatments and dates of applications. Volumetric Concrete Dispenser Mix Design Worksheet OWNER Mobil Crete Technologies Unit Serial# N91-83R YOUR MIX DESIGN (This sheet must be filled out for each mix design) MIX DESIGN 3000 Regular Date 4/27/2016 (max 8 characters) Materials of one cubic yard: Cement 500 LBS. 100% Cement Discharge Speed 44 Counts per Bag of Cement (In Percent) Cement 5.3 BAGS 1.66 Cubic Yard Discharge Time(Minute) Aggregate Pounds of Aggregate Name #Desired Aggregate Name Aggregate (enter 1,2,3,or 4) 1 Pea Rock Aggregate 1 1 Pea Rock 1450 2 Ortona Sand Aggregate 2 2 Ortona Sand 1601 3 Rock#67 4 0 Color OUNCES Fiber Chopper Pounds per Yard Low, Mid, or High Sys Dilution Oz/bag t� f IIQ��1 ' L Admix#1 [1�_ -- Ez H Admix#2 MY 10 2016 Admix#3 PERMITTING (Mid Range available on 130,150,&200 Series units only) St. Lucie County, FL 1. Determine the count per cubic yard. l 5.3 bags/cubic yard x 44 counts per bag = 234 count per cubic yard. �J v 2. AGGREGATE 1: Divide the lbs. of fine aggregate per cubic yard by the count per cubic yard. 1450 lbs.fine aggregate divided by 234 counts per cu. yd.= 6.20 lbs. per count. GATE SETTING(from graph) 5.1 3. AGGREGATE 2: Divide the lbs. of coarse aggregate per cubic yard by the count per cubic yard. 1601 lbs. coarse aggregate divided by 234 counts per cu. yd.= 6.85 lbs. per count. GATE SETTING (from graph) 4.1 Description 3000 Regular Total 234 Counts/Cubic Yard Cement 2.14 lbs./Count Dial Aggregate 1 6.20 lbs./Count Setting Oz/Min Aggregate 2 6.85 lbs./Count Admix#1 ERROR 0.0 *Water 2.07 lbs./Count Admix#2 ERROR 0.0 Aggregate 1 Gate 5.1 Admix#3 ERROR 0.0 Aggregate 2 Gate 4.1 Color #DIV/0! 0.0 Water Meter 35 Fiber Chopper #DIV/01 0 At this point we recommend that you run a 1/4 yard yield test.You must have a box that is 1/4 cubic yard. You can build one with internal dimensions of 36"x 36"x 9".You start the unit producing concrete. Stop both the conveyor and mixer at the same instant. Set the 1/4 cubic yard yield box under the discharge. Start the mixer and conveyor at the same time. Run the unit to the amount indicated for 1/4 cubic yard(1/4th of the meter count per cubic yard from step 1). Shut off the mixer and conveyor at the same instant.The box should be full. It may be necessary to adjust the aggregate gates slightly to adjust the yield. 1/4 Yard Count 58 If you have a water recording meter your lbs./Count will be approximately 1.0425. SRM 08-10 2300 Virginia Ave- Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #:J6011- 0387 JOB ADDRESS: /Na iwo A vy BUILDER/CONTRACTOR: *_OEs�cw\ C.ancrA� PEST CONTROL CONTRACTOR: v t?PzFR' ic.C , PEST CONTROL LICENSE #: y 5 og We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: (00 Chemicals used: eyWC TC Percentage of solution: 01-5�� Total gallons used: Date of Treatment: `l - XL I Co - -- Time of T reetment Footing Slab 1t Treatment 1st Treatment Re-Treat Re-Treat - ---Driveway Pools 1st Treatment 1st Treatment Re-Treat Re-Treat Other SL ��x Ltd or {{ Perimeter for flinal Inspection _1't Treatment Re-Treat Signature of Exterminator Note. There must be a completed form for each required treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re-inspection fee charged. FBC104.2.6 Certificate of.Protective Treatment for p�`evention of termites A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each regared protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used,percent concentration and number of gallons used,-to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval, St Lucie County_requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of.a lications.