Loading...
HomeMy WebLinkAboutProduct Approval i r Florida Building Code Online Pape 1 of 2 :Z) �2 ies�•4rs-�7i�x� aj.t j,�`F� "� x �{� �W, _ �-��^r;rn+`r>r..�. srarF..�,'i•..,r..;,a-+Yet;��.��'':aY;`��i.'t�rr�2.��c'�.�..rsa` iT _3at 'ass..,.,. $s�a_.ti'.anrti.�':+:�9�:+mm>-,� ,4.� ._.r�E�...�.,a,..�M,..._ SCIS nnme. Loll in user Registratxtn trot Topic% ` submit Survtarge Stats h Fitts Vublfctions rile Staff RelS Site I'tap tmnl f-atrh $tJsiine(s(5 ,', - ProfeSJI6t aI �zi USER:Nblit User @I >tk tJ at.i�C.ttSf>APpli—Van Detatt L... y ' FL _ Fu0674R.1Y E _f7`iif '� I- ' '' Application Type Revision Code Version 2014 % ��p�! � Application Status Approved _ / 12 2016 PERrqIITTlr\IG Comments St. Lurie County, FL Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keelert,@owenstorning.com Authorized Signature Greg Keeler greg.keeler@awenScorning.Com Technical Representative Met Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owr FILt Quality Assurance Representative Ad dress/Phone/Ern a it Category ` Roofing } SubcategoryCompliance Method Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Narne who developed the Robert I.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Quality Assurance Contract Expiration Date06/2012017 Validated By j`�.__�.70Wi VT Kr�i-ze vich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 RID CQt 2015 01 L.Ql NE mtnnn.o!J( Referenced Standard and Year(of Standard) S wndaed y-QU ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 20011 Equivalence of Product Standards Certified By Sections from the Code hops:r/floridabuilding.org/pr/pr_app_dtl.aspx7param=wGEVXOvADgIBNbEY5V%2buOT%2b6w7ahRegiCG8ucR6ixEAoifvlt=KNJKxfv#w°l,3ri°r„3d July i,2015 Florida Building Code Online Pace Z o17. Product Approval Method Method 1 Option D Date Submitted 04/2212015 Date Validated 04/2312015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Summary of Products FL iii Model,Number or Name 'Description 10674.1 'Owens Corning Asphalt Roofing 4 3-tab,4-tab,5-tab,laminated,starter and hip F,ridge shingles Shingles and Starters Limits of use installation Instructions Approved for use In HVHZ:No j X115@'4__P_7SL]J 'U1 5!'J_ �L�I ?STS A ( iftT Approved for use outside HVHZ:Yes ;SIIILE1J 7-1-8.1.0.pail Impact Resistant:N/A Verified By: Robert J.M.Nieminen PE-591 GG Design Pressure:N/A Created by independent Third Party:Yes Other:Refer to ER,Section S. j Evaluation Reports S.LiICISiLGS_fLlt}SrZ ftI9 Ad! Created by Independent Third Party: Yes r ED rnntnrt us;;t44a NoaU12jui—h-51t> 7:,n.,h„•.•;:•,•n „ny ppm•-hsn..fx7-ltf: The State att fforida n an AA1EE(l employer.Qn.,tatit 2nn,gni t 5twrr,nI nn la's-;:pny y slawnnnt;;Fltac�.n.urty 5Luculcut;:h..?��,e.�%switf=l, under nonda taw,email addresses are public records,if you do not want your e•mad addfr:s•:rele35ed to rCLpCnSC to a pubd.c•reccinu request,do not santf LfC�tr✓n,^, mal to this entity.Instead,Contact the office by phone or by traditional rail.if you have any questions,piaase contact It50.4a.,.1395.'Putt.uant to Section 455.275{11,Florida Statutes,effective October 1,2412,licensees licensed under Chapter 45S,r.S.must provide ttre Department with alt ema+i addret5;f they I,ave one.The emails provided may be used for ofticibl communication with the licensee.However coni)addresses are public record.If you do not-1!,to su;:ply a PCrSond! address,please provide the Department with an email address which can be made available to the publ,c.To determine if you art a i,censet under chi titer.SS,r.5.. please cbc4 tuc=. Product Approval Accepts: mr-I ®E3 Q ht1ps:llfloridabuddirvg.org/pr/pr apii dtl.aspx?param=wGEVXQwlDgIBNbEY5V%2boQT°/a2b6w7ahRegiCOBucR6ixEAoihteKNJKxMw%3d'%3d July 1.2015 EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate ofAuthoriiation#9503 353 CHRISTIAN STREET,UNIT 013 TRINTY ERD OXFORD,CT 06478 PHONE.(203)262.9245 FAX:(203)262-9243 EVALUATION REPORT 7Owens Corning Evaluation Report 037940.02.12-R5 One Owens Corning Parkway FL10674-RI0 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 5; 04/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the Sill Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.F. if the product.changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature, If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. - INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages I through 6. Prepared by: the b(IlitWe'sem sprin,m)'. 'Ah'l hot 1'e Duh—rt Robert J.M.Nieminen,P.E. SS..... P4 V- P E. Florida Registration No,59166,Florida OC4 ANE19S3 . ......... d(K—cm,!-iped,se.lrtl I--be,"tl--aw�tothr P-d.ct Apponal Ad,,vo-vi,lwo,wid to live n."v,d,t+.i CERTIFICAIION OF INDEPENDENCE: 1. 1 rinity I E RD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is riot owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4, Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of tile product, S. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless temined specifically for that purpose, ;r, TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through to stint; in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. Z. STANDARDS. Section Prove Standard Year 1507,2.5,R905.2.4 Physical Properties ASTM 03462 2009 1507.2.7,1,R905.2.6.1 Wind Resistance ASTM D31GI 2009 1507-2.7.1,R905.2.6-1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Ent(ty Examipskl rt Beference Date UL LLC(CER9626) Physicals&Wind Resistance File 82453,Vol.3 02./1512007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2022 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 Ut.LLC(TS79628) Wind Resistance IICA34308 02/18/2012 Ut LLC(TST9678) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02113/2014 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various. UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/2012017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1,1 Classic'and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4,1,2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire—are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration', Duration Premium Cool, TruDefinition Duration Designer Color Collection, TruDefinition Oakridge,Oakridge and WeatherGuard*HP are fiberglass reinforced,laminated asphalt roof shingles, 4.2 Berkshire Hip & Ridge Shingles, High Ridge, flip & Ridge with Sealant, WeatherGuard, HP Hip & Ridge Shingles, ProEdge Hip& Ridge Shingles and OuraRidge'" Hip& Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record far any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings oFthis product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.71 and R905.2.6-1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to V„d= 150 mph(V,,,,=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F.indicating the shingles are acceptable for us in all wind zones up to V,,,,=150 mph(V,,,,=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design,U.C. Evaluation Report 037940.02.12-RS Certificate of Authodrotion 99503 FL10674-RIO Revision S:04/22/2015 Page 2 of 6 TRINIIFY ERD 5.4.3 Classification by ASTM 07158 applies to exposure category B or C and a building height of 60 feet or less. Calculation,, by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5,4.4 Refer to Owens Corning published information on wind resistance and installation limitations. S.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule.61G20.3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3r per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using;minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: Berkshires shingles require minimum five(5)nails per shingle. X WeatherGuard'HP shingles require minimum six(6)nails per shingle. r Devonshire"shingles require minimum six(6)nails per shingle. y Starter Strip Plus requires minimum five(5)nails per strip. Refer to Owens Coming published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing–Classic"&Supreme: 7Emposicl6n Mansard or Area para Normal Mansard or Area pare Nigh Wind d•avanes y Wind Arose High Wind desvonea y tos nermaloa Areas vitiates fwrres Area para viontas normalos Areas viontos fuarros 5 Mr Exposure Exposieldrs 6.2.6 Minimum Nailing–Berkshire": S.-ahtx.uil• Sa�brx+hq• is!kr dr trtlula tt!kt rtt ultufrr r --►s 4---r a ---+ • s e •r- ----r a.---_-^a e s+—.–,—r a...... -• Rh" 0Yl' 9 W RYy` r t•.J t» w 1 com-010&N,rhu Ia 6,1640 Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS CM111rore 01 Authortronon x9503 FL10674-R10 Revision 5:04/22/2015 Page 3 of 6 TRINITY ERD 6.2.7 Minimum Nailing–Devonshire'": Nails t gaits _j Ion r Spots of As;hal,,Roof Cement 6.2.8 Minimum Nailing–Duration®,TruDefinitionO Duration, Duration",Premium Cool&TruDefinition Duration Designer Color Collection: 4 WA Fitton 6 Nal EbqUallia do 4 clava., Pattern Svollair,blwing 4m vidth d#64:1 4:14vos k.,,dims Su,.UaV' V 1.)el 1."XI: Ir w Fft�N t L F =AJ 5W Ex"m Nil, 5r'fapmure 5s put;.do t*pDtitbo euvos Exr.more 5ii1rdfi.di,opffskhill (low" "k IX:hr.fie cxjwnhiw 6.2.9 Minimum Nailing–TruDefiniflon*Oakridge",Oakridge": 4 N;A1 Pdtwn 6 NJI Nnorn 6guma call C Claw Esqurma tar 6 clavos v V.,--)Pl I F—A Expow D jail, Evppsirivn et 551$pz(q, clpw bpojid6n do 6 S/Sping &Sff EXPOU10 CL)W EWv �_ w Fspo4van do 6 G/P pvlq flpoct4an do 5 r'1fP;e4 6.2.10 Minimum Nailing–WeatherGuard'HP: 11111200 Gkb View Vbw Aeft"I FamnarThrewo NO Uma Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS CerflProle of Authoriturion 99SO3 FL10674-AI0 Revision S:04/22/2015 Page 4 of 6 TRINITY ERD 6.3 Hip&Ridge Shingles: 6.3.2 Installation of Berkshire Hip and Ridge Shingles, High Ridge,Hip&Ridge with Sealant,WeatherGuatd.HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4)nails per shingle. Installation of DuraRidge'"Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)mails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 2507.2.6 or R90S.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire,'Hip&Ridge and High Ridge: Fla.t FIp.2 l li t t�.v�tnnwna , c i InpN— tit�NrN .. i 1 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: em Fig.2"HighWind Fastening Pattern (4 Nails) rim ShingleA2" Ind Discardeccess ScalantStrip 12" 'Fastening 5-,,. 5"Exposure Distance 12" 6.3.5 Minimum Nailing—WeatherGuard"HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A Paver/tgYlY+e ..X,, •t IA , s rxprt."ry �._—,--- Elp�suro s I Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization 0930.9 FL10674•RIC Revision 5:04172/2015 Page S of 6 TRINITY ERD 6.3.6 Minitnum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard --11' ----� Wind DirectionFaetening { Swtent5ttip . Pattern I $'Exposure �'ry F- 1 "I �•{ i.! 'x 72 t 5catsnt Fasten 711'' 7'G' ti Exposure CowtEspoad Fasteners with Roof Cement 6.3.7 Minimum Nailing—DuraRidger"Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. P+.giine Wltd Oascdan Sot.Yir. ~ Doom" Wo"t.&J""t ,r,s 1. vnia iu0erix !'f> [ri+rcd6nd.f.i«ear pr.do[nient• ttalV•«, ._..„1._ nMtfM t a[I�fYn$NICr{JJ Iota L aI4� &Z N h 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FISC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;kjUe!�Irurhmanni`�ul.carti? END OF EVALUATION REPORT- Exterior Research and Design,U.C. Evaluation Report 037940.02.12-RS Certs/irate ojautbor{totran 119503 FL10674-R10 Revision 5:04/22/201S Page 6 of 6