HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC.
806 Delaware Avenue, Fort Pierce, Florida 34950
PHONE(712)460-7151 FAX(772)460-4244
EMAIL cookmenard@yahoo.com
May 12,2016
MAY 13 26%
Saint Lucie County Building Department PEPMd;irriNc
Attn:Shutter Permit Plan Review St. Lucie Ccun;y, FL
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Shutter specification prepared for the Fort Pierce Building Dept.for the structure located at,
321S S. Lakeview Circle, Fort Pierce, Florida
Manufacturer: Impact Technology, Inc.
Profiles: Accordion Shutter, FL#12549-115
Code: FBC 2014;Section, 1609.1.2
Wind Speed: 165 MPH; Ultimate Design Wind Speeds
Exposure: C
Mean Roof Height: 20' Maximum
Required Design Pressure: Zone 4-61.7, Zone 5 -74.1
Maximum Uplift Pressure: +/-75
Fasteners: %" ITW Tapcon w/1-3/4"embedment @ 6.4" o.c.
The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code,and the
manufacturer's recommendations.
Respectfully Submitted;
f
o
✓ l�ti s. t, vt r , t t, zt 1"iy-�`r
Jfv P6ter.B:'CO`ok
t 'Cook;& Menard Arch�tecture; lnc.
Florida Registration No. AA0003494, NCARB Certification No. 31789