HomeMy WebLinkAboutProduct Approval Florida Building Code Online Pagel of 3
Rusiness&Prokssionall Regulation
Florida Deparnentof SCIS Home Log In i User Registration Hot Topics ( Submit Surcharge Stats&Facts Publications FBC Staff i BCIS Site Map I Emla Search
Bus'nes
k I a
E r !, sl product Approval
USER:Public User
Regulation
Product Approval Menu>product or Application Search>Application Us t>Application Detail
FL# FL5891-R5 R E C:%p
Application Type Revision
Code Version 2014
Application Status Approved MAY 16 �01�
PER.AITTiNG
Comments 51. Lucie County, FL
Archived El
Product Manufacturer Therma-Tru Corporation
Address/Phone/Email 118 Industrial Drive
Edgerton,OH 43517
(419)298-1740
rickw@rwbldgconsultants.com
Authorized Signature Rick Wright
rickw@rwbldgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
RJ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J.King,P.E.
J Validation Checklist-Hardcopy Received
Certificate of Independence FL5891 R5 COI Certificate of Indeoendence.pdf
Referenced Standard and Year(of Standard) Standard Year
SSTD 12 1999
TAS 202 1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquw6mPIZhp%... 5/16/2016
R W R W Building Consultants, Inc.
B Consulting and Engineering Services for the Building Industry
C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197
Florida Board of Professional Engineers Certificate of Authorization No.9813
Evaluation
Date: Januarr 29, 2015
Product Sub Category Manufacturer Product Name
Category
Swinging Therma Tru Corporation TO"x V8"
Exterior Exterior Door 118 Industrial Drive "Smooth Star"
Doors Assemblies Edgerton,OH 43517 Fiberglass Single Door
Phone 419.298.1740 Inswing i'Outswin "Impact"
Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E.for Therma Tru
Corporation based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval,Department of
Business&Professional Regulation.
RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
UmHations.
1. This product has been evaluated and.is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements
excluding the"High Velocity Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in areas requiring wind bome debris protection this product complies with Section 1609.1.2 of the FBC and does not
require an impact resistant covering.This product meets missile level T"and excludes Wind Zone 4 as defined in ASTM E1996 and
Section 1609.1.2.2 of the FBC.
4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of drawing FL-5891.2 require further engineering analysis by a licensed engineer or
registered architect.
6. See drawing FL-5891.2 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Sinned by
ETC 01-741-10700.0 TAS 202-94 ETC Laboratories Wendell W.Haney,P.E.
CTLA 98OW SSTD 12-99 Certified Testing Laboratories Ramesh Patel,P.E.
2. Drawing No. Prepared by Signed&Sealed by
No.FL-5891.2 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E.
3. Calculations Prepared by Signed&Sealed by
a°`'E'n"'''�p
Anchoring RW Building Consultants,Inc.(CA#9813) ko 3�v,� r,l � r„ Lyndon F.Schmidt,P.E.� Y
4. Quality Assurance oa°���.��. •�.`. :�1 �dgr
Certificate of Participation issued by National Accreditation and
Management Institute,certifying that Therma Tru Corporation is
manufacturing products within a quality assurance program that complies
with ISO/IEC 17020 and Guide 53. rJ r
`�. Lyndon F.Schmidt,P.E.
y`' B s, .,.;• +. FL PE No.43409
1/29/2015
Sheet 1 of 1
THERMAITRU L—
37.59"MAX.OA.
FRAME WIDTH
THERMA TRU DOORS ;�>•••.. � a^
1 18 INDUSTRIAL DR., ED[3ERTON, OH 43517
I�----PANg MAX
E
30 2 °ZU
t tt X6tt
8 t E 9 0=a
\ ' 2.2 L
"SMOOTH STAR" ® ® a�
FIBERGLASS SINGLE DOOR
OOR
INSWING/OUTSWING N
"IMPACT" m R50 z
Y QU
o O �
GENERAL NOTES O 2 d ��
• �1I � �y
1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building o o z
Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 0. a a
2. Product anchors shall be as listed and spaced as shovm on details.Anchor embedment to base 'm
N material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with Section
v
3 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets missile N
level MO and excludes Wind Zone 4 as defined in ASTIM E1996 and Section 1609.1.22 of the FBC. rn
W p O
N
4. For 2x stud framing construction,anchoring of these units stall be the some as that shown for 2x N
N buck masonry construction.
S. Site conditions that deviate from the details of this drawing require further engineering analysis R
by a ficersed engineer or registered architect.
$ I °
TAME OF CONIENIS
SHEET I DESCRIP110N N
1 Typical elevations,design pressures b general notes OVERAI[ !)ESIGN PRESSURE(PSFj -m
2 Door panel details SW/NG I kAlNE N—z
13
3 Horaontolcross sectim ;' b111AENSfOA1_ P05111t/E ; NEGAT►VE:_ DU 4 23 08 1.0
5 Buck�dframeorktroiv�q-21(buck masonry corshucflon INSWING 37.59"x8219' +67.0 -67.0 � N.T.S. 9
M.Err. AL m'
6 Raw orxboring-IXbuck masorvycorshvation OUMMNG 37.59"x80.69" +67.0 -67.0 ��. CFS 3
7 Bi of Mafeft b 8 Components
onAworo'ro.: rt
FL-5891.2 a
o ��� 7
O
9
Rlaknts\Themv Tru PSIMANBModda Pmdud AppmuMR-S891\Dmvtngs\Cunent\R•5891dwg.22
d
� m
q
ND
Tim
I ::.j
T0I-0 -Mm
7n0
H
1.54"+{ Z
rn
Dom' s
- _ at
pt
w
22
A
FA
H Z
22
` s '
N0.43400
/W/� J
S PRODUCT: Deoum.rrt.Pr%W-d BYs .z .80QLOF
THERMA—TRU Lyndon F. Schmidt ��i� '.;401Ed,.•'f ,����
IN I a` FIBERGLASS DOOR P.E. No. 43400
2 kDATE
UPDATE TO STH ED. 2014 FBC (.F'S PART OR ASSEMBLY: BUILDING CONSULTANTS,
Iv N � y p� 1 REVISED TO 2010 FBCJK DOOR PANEL DETAILSP•0. eor 230, VDlrlco, FL 33808
NO BY Phon. No.: 813.880.0107
REVISIONS FBPE C.A. No. 0813
C 2008 R.W.OUILDIND CON.ULTANM INC.
R\Oients\Themu Tru PERMANENT\Florida Product ApprowlsW.-SB91WraMngs\Current\FL-S891.dwg.32
Z
v m
. v
w�
v �
nO a
0 n
r$ pq
$g yr V
rWH7s N A
O Go V G
O D.
m
A_ A
O O A A ® ® 13
® A N
A A
D
W W W N
Z
W W 700 IA
=:C
x i G O V
O
Q A O •O
n 7O
>T
T A n o
O ? > x
M M
v
wN O O •.m
A A • • m
Z
O O
O
7
oPK
O •O
N
T
n O
O
Z
O �
m 4 v
e . `4
a ,"4 • -.
? No.49409 i
1
$y 4 PRODUCT: Doeummta Pnvor+dMys �p{7{Ol000
• �,r
THERMA-TRU Lyndon F. Schmidt /i/ •'ti!;101EDR•'
i. FlBERGLASS DOOR P.E No. 43409 /// '••' ���
�
Ip, y W 2 1 28 15 UPDATE TO 57H ED. 2014 F8C LFS PART OR ASSEMBLY: BUILDING CONSULTANTS tWtt
5n o •1 6 11 12 REVISED 70 2010 FBC JK P.O. Elox 230,Valrleo, FL 33696
I� N Co NO DATE BY HORIZONTAL Phone No.: 6/3.669.9797
REVISIONS CROSS SECTION F9PE CA No. 9613
0.2008 R.W.6UILOINO OONOULTAW.INO.
0041MAlhenna Tru PERMANENTWodda Product Approvals\FL-5891\DraAngs\Cunent\FL-589Ldwg,42
v M
w
• IM A
A W o A r
�7fgi •a �fi
n i^• r0 n
7^ ?r
N •. tqo
A N � am V
N 7O—O M
o'
7C
1-1/4"MIN.
EMB.(TYP.)
m
M
$ m $
ER z
71
• A 7D `o
• Q N�
x^
n P A
s
.o.: -4 m c o
W V
v.Q
•O
1-1/4•MIN.
EMB.(TYP.)
zz
L•
(� -*1j• No.43409
TJ2�
iAgf
PRODUCT: Documents Prepar d Byn y •q foGeOF
THERMA–TRU fid No F.�ChOmldt •°•e;�Lq��.••' ,����
I� I FIBERGLASS DOOR
14 rOp y W 2 1 28 15 UPDATE TO 5TH ED. 2014 FOC LFS PART OR ASSEMBLY: OUILDINO CONSULTANTS
!/1 O 1 6 11 12 REVISED TO 2010 FOC JK P.O. Bok 230, Valrloo, FL 33898
I� N tb NO–PAM
RCTCROSSSECTIONS Phone No: 813.689.0197
REVISION
POPE C.A, No. 0813
O 2DOB R.W.BnILDINO CONBnLTANTS INC.
eg
JAW-Z
i5,
ZO
11♦♦ IT
o IWO z
p aN•;
2 .ZU
MASONRY TYP.H�& — MASONRY #mpg 9 m 1 a
OPENNG JAMBS OPENING d 1 m a 1112
4
G
gE o=
B 3a
FRAMEK Nz
_ Pn TYP.HEAD&
Od •n JAMBS FQ U WW O O
z 0 �o 6v;
2X BUCK o r-: > m�
2X BUCKS, s
— tF-W W O
Q3 O
�j fY
O Y
W mm
m
O
'-40
z
g SUCKANCHORING SIRIKEJAMS FRAME ANCHORING HINGEJAMB w o
Masonry 2X buck comtruct'ion Nch
CONCRETE ANCHOR NOTES: �+
1.Concrete anchor locations at the comers maybe adjusted to maintain the min. pc rr
edge distance to mortar joints. Ln
ly
2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to
maintain the mh edge distance to mortarjoints,additional concrete anchors =
t may be required to ensure the MAX.ON CENTER"dimension are not exceeded. 9 ^
3.Concrete anchor table: K n=a
MIW-JC kItAA1GE. MIC1.CAE CRANCE: m o
`o 1N NQR.:AIjIGHOIt::: :Nl......::::::i:;;:i; .. ..;..
EMBEDMENT TOMASOfJRY.i;:t::.'::;::'TO,jIDl11C"ME o 'z
.. .. ..................................
ELlGE...:'::i<3 :;:':ANCHOR:= �0 K
HIN27 asc
PC ® 1/4" 1.1/,' r 4 4 N.T.S.08
TA�CON scut:: N.
ELCO DY&W. AL 'm
ULTRACON 1/4" 1-1/4" 1" 4° aoc W. LFT 3
WOOD SCREW INSTALLATION NOTES: MW.G iz d
1.Maintain a minimum 5/8"edge distance,I"end distance,d 1"o.c.spacing HINGE DETAIL LATCH L DFADBOLT DETAIL FL-5891.2 °a
of wood screws to prevent the splitting of wood. n
o sir 5 or 7 O
0
R1°Ielns\Thmna Tru PIAMANENI\Plodda Product Apmmis\FL•5891\DraMrlgACurrma\FL-S89Ldwg,62
� N —
g3 :::::::. 0,0
5.S 39.38"
y iiiisa °I `
isl' a �
49 CR 0
.
CL ' ( ' Froz
EL
Q `8 x
� g a n °$
14"MAX.
O.C.PYP.)
x
29.2.7
m
HING O NGE 10.13"
r V N
x
= M
G
T
ram q
O
O
V7 V7
O
Q PRODUCT: Dti Prqmfsd slr % •5••evaeGr
FIBERGLAS DOOR P Ed No 43409mfdt �i� .;ZowD!;.•_
2 i 28 15 UPDATE TO 5TH ED.T2010 FRC LFS PART OR ASSEMBLY: 7�/BUILDING CONSULTANT5/1�� 1f1
U1 O 1 6 11 12 REVISED TO 2010 FRC JK YY P.O. Box 230,Valrleo, FL 33595
I-4 N CD NO DATE BY FRAME ANCHORING IX BUCK Phone No.: 813.559.9197
REVISIONS MASONRY CONSTRUCTION FBPE CA No. 9813
0 2008 R.W.Ia UILCINM=N\ULTANTO IND.
BILL OF MATERIALS
REM Dt3CRiPRMATERIALON �* �
A 1XBUCKSG>=0.55
WOOD $ 1 '� a
B 2XBUCKSG>=0.55 WOOD �-456' –� %N•: •*�� 00
C MAX 1/4"SHIM SPACEWOOD 'moi �'•., ��� z o v
D 1/4"X 2.3/4"PFH ELCO OR RIN CONCRETE SCREW
E CON
MASONRY-3.000 PSI MIN.CONCRETE CONFORMING TO ACI CRETE
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 a
G 3/16"X 3-1/4"PFH ITW CONCRETE SCREW STEEL c .�� h $ o=v
H 1/4"X3-1/4"PFH ITW CONCRETE SCREW STEEL o 09L
STEEL
J 1/4"X 33/4°PFH UW CONCRETESCREW °1 c_
K #8 X 2-1/2"PFH WOOD SCREW S 19 M aSlDE ` a
L #10X2"PFH WOOD SCREW STEEL
7 SHORT REACH COMPRESSION WEATHERSTRIP FOAM
8 LONG REACH COMPRESSION WEATHERSTRIP FOAM
9 4"X4°HINGE.097°THK. STEEL
10 #10 X 3/4"PFH WOOD SCREW STEEL
17 KWIKSET SIGNATURE SERIES PASSAGE LOCK STEEL o -+
18 LOW PROFILE OUTSWING BUMP FACE THRESHOLD ALUM/WOOD2�"
I� i
19 HEADER JAMB PINE,S.G.>=0.42 WOOD � � > �o
20 SIDE JAMB PINE,S.G.>=0.42 WOOD sir ao
21 KWIKSETSIGNATURE SERIES 780 DEADBOLT STET
27 LATCH STRIKE PLATE STEEL 4.67 m
I � ca
28 DEADBOLT PLATE o
STEEL o
14 32 DOOR BOTTOM SWEEP PVC z <
33 SELF ADJUSTING INSWING SADDLE THRESHOLD ALUM.COMP. 1C TAWPtOAlEOU1SWINGlUMPFACE a a
40 FlBL RGLASS DOOR PANEL-SMOOTH STAR _ m
SS DOOR SKIN.070"MIN.THK FIBERGLASS BY
41 THERMA-TRU WITH YIELD STRENGTH Py(MIN.)=6.000 PSI SMC
42 TOP RAIL COMPOSITE
3 43 LATCH STILE LVL WOOD
0
44 HINGE STILE WOOD o 4 tn
z
$ 45 BOTTOM RAILCOMPOSRE a o
., 46 POLYURETHANE FOAM CORE-1.9 LBS.DENSITY FOAM 5.75 ir$
147 LOCK BLOCK REINFORCEMENT WOOD i o
NOTE:WOOD/LVL COMPONENTS(PINE,SG>=0.42) I L o 91in
Ee
rc z
c j !2^
$ _w i
s N^Q F
• m z
Z
�1 S(3F ADJUSBNG SADDLE TNR6d10lD "''-Z �
D
4123108 °z_
MTS. °
2 u0m er. AL c
aoc er. LFS 3
g DRAWM tJD: a
6
FL-5891.2 °n
6 sacr 7 ov 7
Florida Building Code Online Page 2 of 3
Date Submitted 06/13/2015
Date Validated 06/28/2015
Date Pending FBC Approval 07/05/2015
Date Approved 08/18/2015
Summary of Products
FL# Model,Number or Name Description
5891.1 a."FiberClassic" 6'8"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL5891 R5 II Inst 5891.1.ndf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 5891.1 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.1.pdf
specific Model and for any other additional use limitations Created by Independent Third Party:Yes
and installation instructions. (For FiberClassic doors,this
product approval requires the use of"Y'part numbers for
these doors,which have been stained or painted within six
months of installation.)
5891.2 b. "SmoothStar" 6'8"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5891 R5 II Inst 5891.2.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 5891.2 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.2.odf
specific Model and for any other additional use limitations Created by Independent Third Party:Yes
and installation instructions.(For SmoothStar doors,this
product approval requires the use of"]"part numbers for
these doors,which have been stained or painted within six
months of installation.)
5891.3 c. "ClassicCraft" 6'8"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL5891 R5 II Inst 5891.3.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 5891.3 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.3.pdf
specific Model and for any other additional use limitations Created by Independent Third Party:Yes
and installation instructions.
5891.4 d. "FiberClassic" 8'0"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL5891 R5 II Inst 5891A,odf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 5891.4 for Design Pressure Ratings by FL5891 R5 AE Eval 5891A.odf
specific Model and for any other additional use limitations Created by Independent Third Party:Yes
and installation instructions. (For FiberClassic doors,this
product approval requires the use of'7"part numbers for
these doors,which have been stained or painted within six
months of installation.)
5891.5 e. "SmoothStar" 8'0"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL5891 R5 II Inst 5891.5.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 5891.5 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.5.pdf
specific Model and for any other additional use limitations Created by Independent Third Party:Yes
and installation instructions.(For SmoothStar doors,this
product approval requires the use of"]"part numbers for
these doors,which have been stained or painted within six
months of installation.)
5891.6 f. "ClassicCraft"
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquw6mPIZhp%... 5/16/2016
Florida Building Code Online Page 3 of 3
8'0"Impact"Opaque Fiberglass Single Door(X)Inswing or
Outswing Configuration
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL5891 R5 II Inst 5891.6.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 5891.6 for Design Pressure Ratings by FL5591 R5 AE Eval 5891.6.Ddf
specific Model and for any other additional use limitations Created by Independent Third Party:Yes
and installation instructions.
Back Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 _
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement;:Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click he=.
Product Approval Accepts:
sCLVnt METRICS
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquw6mPlZhp%... 5/16/2016