HomeMy WebLinkAboutProduct Approval (3) Florida Building Code Online. Page. 1 of 4
lit?dd Iftne t,4' ,BCIS Home; i Login User Registration Jio[TOPI S f SULxNt Surchdrge Stats&'Facts Publicatlms °FBCSWff SCIS SA.Mep Unks Search
BUslnes ,�, nn ,
0-10�roductApproval
d6ssi USER:Public User
Regulation
.. ,. :E.iaCltsk F'-.fX'.Cs.'.{al Mrnu?E 45114.CGrPBNIcs��4!1/.-;[4h.>c�A L19>;Application Detail �a�Aga, 1 �l1V
M
N.I
FL.# FL1956-R12
MAY
Application Type Editorial Change PER�AiTTI lG
Code Version 2014 St,Lucie County,FL
Application Status Approved'
*Approved;by,QBPR,Approvals by DBPR.shall be reviewed and
ratified by the'POC and/or the Co_mmisslon if necessary..
Com men is
Archived )_
Product-Manufacturer TAMKO Building Products,Inca
Address/Phone/E mall PO.Box.1404
Joplin,,MO.44804
(417j 624-6644 Ext 2305.
kerri_edeh @tamkb.com
Authorized Signature.: Keni Eden
keni—pden,@tamko.com
Technlcal,Represent4bye Kern Eden
Address/Phone/Email PO Box 1404,
Joplin,.MO 64802'
(417y,,,624-6644 Ext 2305
kerr1_eden:@ta mko.co m
Quality Assurance Representative
Address/Phone/Email'
Category Roofing
Subcategory Aspha)t Shingles
Compllanpa',Method' Certification Mark or Listing
Certification!Agency U L;LLC.
Validated.By Robert 7.;M.Nleminen,PE:
FG Validation Checklist-Hardcopy Received
Referenced,Standard and Year(of'Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of:Product Standards
Ceitihed:'By'
Product,Approval'.Method Method 1 Option A
Date:SubrnItted 09/17/2015
http://www.flond6uilding.org/pr/,pr_app_dtl.aspx?param=wGE VXQwtDgs%2fmGFoyT6... 1/1:4/2016
Florida Building-Code OrAiiw Pap 1 of 4
Dat67Validat4d 10/0612015
Date Pending FBC Approval
Date Approved
ci/pq/zols
untima :01prdducts
FLV Modelj Number Description
or'Name
1956.1 j.IEllbe:Gkw-S6al A three tab-asphalt'Otingib.
Limits-of Use Certification Agency ate
Ceif'c
,Approved foriuse.in F1-1456 Rig:CAC J`1-1656 Ril.&C-A6. farnko'sery Coni FLA956 72615.pdf
HVHZ:No EU1956 R12 C-,,,CAC'.ILL certification -11-1 f
Approved for use outsideQua,' ity Assurance Contract Expiration Date
HVHZ:'-Yes 09117/20:1.9:
Impact Resistant N/A I nsta Ila tio-wl nstructidns
Design Or.essure::h/A 'FLi-56 k12 II Gigs, Seal Elite Glass-1 Seal I aj2p Instodf
Other:#7phal'tshlng'les Verified By:Robert Nlemlnen.59166
shall be udedonly'on roof Creaked.by'Independent Third Party: No.
slopes of 2=or greater. Evaluation.Reports
Nalls.must be.used.as,the Created.by,Independent Third.Party:Party:
method of attachment.
--------..................... ...........................——-----
1956.2 ;Glass-Seal A three tab,asphaltshingle.
Limits of Use Certification Agency Certificate
I . I
40roVecl for use'lin h1956 K12 Ri956:Rli:C CAC Tarml6tery t6riffl-1956 4615'pdf
HVHZt No FU956 R12 C, -CAC UL certification:'IomllAzxdf
HVHZ;
for use outside Quality,4ssurante Contract Expiration Date
HVHZ::'�es
Impact R.esi I's.ta nt. N/A 'Installation Instructions.
De.-gn. ressure: N/A FLIM R12 11 Glass Seal Elite Seal apo Inst 6df
Other::Asphaltsh Ing les, Verifled By:Roberf.Niemlnen'PE 59166
shall be used only on'roof Cr.L-aWd'by:Independedt7hird.Party:No.
slopes of 2:12 or:grea ter. Evaluation
Ev luali o
a P-Reports%
Nalls.must be used.,as the Created,by Independent Third Party:
metfi8d`of,attach men"f.
1956:3 i Heritage A:dimpn's*lo*nal.asp'fiA shingle.
Limits of"Use Cbrtifi66tf6rfAge'ncV Certificate
Appkived for•6se,in FUM R12 0,CAC PL1956 111,1'c CAC Taml6.Sery C,6nf FL 1956 201jS]'kd-f
HVHZ:No . FL1956 R12�CCAC UL certifications 10-1:1-12.p�d
HVHZ:
for.use.outside Quality Assurance.Contract Expiration Date
HVHZ.Yes 05/17/2:01.8
Impact'Resistant:-N/A instillationinstructions:
Pe$ign,Rnjssur.e:'N/A FLf956 1112 11 Heritage D F I P app instgid
Other., FL R12�Jlerit,a_qeF app InsEpof,
Asphalt'sjhlngles� �j7 1956
FL
shallbe used only.on,roof 19�56 R H aDry lirsf.o&
slopes of 2A2'.or-gre'a'ter, Vekified:By;Robert1. M.Nie mln(iftFL 59166
Nalls'mu'st,be iused.as the CriMt)ed.'by-Irid'e*p'e'ndentl'hir.d Party:No
method of-attachment. Eyziluatiolin-Repofts-
Created'.by IjnOiepenoentThird Party:
1956:4 'Heritage 30 �A dlm�e..Ional asphalt shingle.
Limks,c4 Use .Cer.tifi I cation'Agency Cer.tificate
.Approved for use.in CACTamko Serv.Conf FL'i956 1415
pd f
HV,HZ.:No, FL1956 R12'C-CAC UL-6erh'flqatldK 10-11-12.0d
Approved for.use outside Quality,AssOrdnce-Contract Expiration Date
HVHZ'Yes: 09[17./2018.
Impact Resistant:N/A Installatiorr,Irstructions.
besignpressure:N/AFL11496 Rig it heri I tacie 30 app I I nst-:aUM 10.Rdf
Ciihie-r-Aip'haitw6g'les' FLA956 R12 Ir:heritage.:30 aiq2Inst f abril'16.pdf
shall be-.us6d.pniy on:roof Verified By,.Robert,Nleffifrien,PE 59166
slopes of 2:12 or greater. Created by,Independ.ent'Third..Party;arty:No
Nalli,mus t.be used as the fivaivaiio n.Repo rt s:
method 61"6tiaclimehf. Created 6y Ificli"
�pdiiderrt Th I rd Tarty:
1956.5
956�Ae�oge SQ A-0-I.mensional.asphal.t,shingle.
Limits of Usii Certifica!ioh Agency Certificate
Approved for-Ose in hi956 i4i2-C,-CAC FL1956.P11"g- Ta mlo:�Sery:gonf FL 1956 2015.odf
HVHZ:No Ftfg 56 R12'C,;CAC. UL"' certification -10-11-12,12df;
,Approved(pr,use,outsideua'i'Vsurance:.Contract Expiration Date
HVHZ:Yes /i7/
Installation
Impact
Resistant:914 Ins
De Oirbssu're---,N/A "SO ab6"InWabril 10.ridf
Other:Asphalt.shingles FLOSS R1 H�hhrerltaqe So 66pjnst 1`3 apell 10.odf
erifled.By��o ;Nlemlnen PE 59166
shall be used only,pn;-of t
slopes of 2;12 or greater.. Created,
by1ndepencieni'"ThIrd'.Party:No
Nails-must be used'as'the Evaluation Reports
method ofattacKment.; Cr
eated by Independent Third,Party,
.http://www.flondkuilding..,org/prl,pr_ap ,,p_Otl.aspx,?paranl=wC-rEVXQ.wtDqs,%2fmGFoyT.6... 1/14/2016.
Florida Building-.Code Online, Page.3 of 4
,
1956:6 Heritage Premium A dimensional asphalt'shingle
Limits of Use Certification Agency Certificate
Approved for use in FLi956 R12 C CAC FLi956•R11 C CAC Tamko Sere Cont FL 1956 2015 odf
HVHZ:No FL1956 R12 C'•CAC UL'cerdficatlon 10-11-12.odf
Approved for use outside Quality Assurance Contract Eicpieation Date
HVHZ:Yes 09/17/2018_
Impact Resistant:N/A Installation Instructions:
Design;Pressure:;Q4 FL R12`II Heritage Premium D' P.app Inst0f.
Other:Asphaltshingles FLi956 R12 II Heritage Premium.F�apo instlodf,
shall be`used only on'roof FL1956 R12 II Heritage Premlum:T°ago Inst pdf
slopes of`2;12'.or:greater. Verlfled.By:Robert Nleminen 59166
Nalls.must.b9%used as.the' Created;;by Independent Third'Party;No
method of attachment.: Evaluation Regorfs:
Created`tiy Independent'Th led.Party:
1956.2 Heritage Vintage A heavy welghkdlmenslonal asphaltshingle:
Limits of'use Certification Agency Certificate
Approved for.use in FL1956 R12 'C'CAC FL1956 Rid C.CAC Tamlko.Sen Conf FL 1956 201S.odf.
HVHZ.No FJL1_g_S�-,RiZ_C_CAU "I
_ -s e-matrjg1Pdf
.Approved for use;outside Quality Assuranc.9 Contract Expitation Date
HVHZ:Yes 09/17/201@;
Impact Resistant:N/A Installation,Instructions
Design;Pressure::N/A' FL1956 Rig-II Herilade Vintage.*apo inst.odf.
Other:Asphalt shingles: VerLfied;By:Robert]i,:M.Nieminen MS9166`
shall be used only.on roof; Created.by Independent Third'Party: No
slopes of 2•:12'or,greaten, Evaluation Reports
Nalls'mustbe,usedas'the Created'by.Independent'Third.Party:
method,of attachment:
1956.8 Hrltage Vlntage Hlp:and Hdgeshlndles
124'121-11parid
Rldge
Limrts of"Use Certification Agency Certificate
Li
Approved for use in F956 Rig C CAC' FLi956 R11 C CAC Tartiko Sery Conf FL i956 2015 odf
HVHZ:No FL1956 Rig'C-CAC;ULshingle matrixtpdf:
.;Approved for use,outside Quali_ty.Assurance�Contract Expiration Date
HVHZ:"Yes 09/17./2018,
Impact Resistant:,.N[A Installation Instructions; .
Design Pressure:..N/A FL1956 Rig II TAh1KOna HerltaoeA 112 x 12 Rio and: Ridge Appllcation InstrVctlont.pdf
Othec:.Asphalt shingles, VerlfledBy:.Roben:.7; M.Nieminen PE59166
shall be used only.on.roof Created bydndependeni'*rd'Party:No:
slopes of 2:12 or,greater. Evaluation Reports
Nalls musf;be used as theCreated liy IndepehdenbThird Party:
method oflattach'ment.•
1956.9 Heritage A dimensional asphalt shingle.
Woodgate
Limits of:Use Certification Agency Certificate
Approyed.for,use in FLi956 R22 C CAC FLi956 I C'CAC Tamko Sery Conf FL 1956 2015 odf
HVHZ:No FL1556 R12 C-CAC UL certiflcatlan 10 q i:_12,odf,
Approved for use outside Q'ualltyrAssurance contract Expiration Date
HVHZ:Yes. 09/17/2018'
Impact Resistant:.N/A Installation'Instructions
Design,Pressure:;N/A FLi956 Rig II HeHtage-Woodgate D_app nst.pdf
Other 'Asphalt shingles FU-956 R12 II Heritage NJoddgate;F.aop 116st udU
shall be'used only,:on roof Verified•By Robert Nleminen 59166,
slopes of 2:12 or greater.. Created bydndependent'Third.Party:No
Nails must be used:as tfie Evaluafioh Reports:
method of attachment.: Created:by IndependentThlyd,Party;
1956:10'Heritage XL 'A dimensional as shingle:
Limits of:Ilse Certrfication,Agency Certificate
Approved foruse in FLi956 R12 C-CAC FL956R11'C CAC Tamko Sery Conf FL 1956' 015 pdf
HVHZ:No , FU956 R12'C"CAC UL certificatlon1Q-11.12 pdf'
:Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes , 09/17/201e;
Impact Resistant::N%A Installation Instructions;
Design Pressure; N/A FL1956 R12'II herltaae xl app Inst'd abdl 1.0.odf
Other.Asphalt.shingles, ;FLi956 R12 II:heritage xl 'app Inst-f apni 10.0f.
shall be usedonly.on,roof verified-13y:Robert:Nleminen PE 5916.6
slopes of 2112 or greater. Created;byIndependentThlrd:Party; No
Nails must-be used as.the Evaluation Reports:
method of`attachment.: Created'by+Independent'Thlyd".Party:
1956.11 Hip and Rldge; Hip andridge,s.hingles;
ShIngli
Cimits'of:Use Certification AgencyCertificate
Approved for use,.in FLi956 Rig C"CAC FL1956 Rli C CAC Tamkg Seru Conf FL 1956 2615.pd
HVHZ;No ,FL1956_R12't-CAC UL_certification 10-11=12 odf
http://www.flondabuilding.org/prl,pr_app_dtl.aspx?paratn=wGE VXQwtDgs%2fmGFoyT6... 1/14/2016.
Florida Building:.Code;Online. Page.4 of 4
Ap'proVed for'use outside Quality:Assurance•Cootract Expiration Date
HVHZ:-Yes: 09/17/2018
Impact Resistant:N/A Installation Tn'sttuctions_
Design Pressure:..N/A FL1956 R12 II 12.2SxI12 'Hip and Ridge pdf
Other:Hip and Ridge FL1956 R12 II. Q x 12 Hip Ridge ApplicatJon Insttuctions`odf
shlogles shall,be used only F11956 R12 II_12_-1-4'xi2 HipRi e Sealant-Dab Illustrations_.pdf
off roof'slopes of2:12or FU956 R12 II 12;12 HIPPJdge Sealant'Dab Illustrations'odf;
gena*r.halls.must,be;used 'VeHfied'By:-Robelt`Nleminen_59166.-
as the method of Created by Independent Third Party: No
attachment. Evaluation Reports
created-by IndependentWrd Party.:
flack next
Colit
ar Us::'1940 North Monroe Street.Tallahassee FL 32399 phone:8so-487-1824
The state'&Florida is.an Aq/EE0:employer:Coovnght 2007-2013 State of Florida r 2rivacv stAement::AcceSsibilib 5tatement::'Refund Statement
'Under Florida law,email addresses are public records Ifyou donnot wantyourre-mall address released in response to a public-records request,do not send
electronic mall to this entity.Instead,.contact the office-by'ph9ne or by:traditlonal mail,If you have any questions,please contact 850!487.1395.*Pursuant to.
Section 455.275(1),Florida Statutes,.effective'6&c8er 1,2012,'licensees.11censed under'chapter 455,F.S.must provide the Deparhnent wlt i:an email:ad�nss if
they have,'one:The emails provided may be used for official-ccrnmunici tion with the Ifcensee:However email addresses are public recdd.If you do notwish m
a ,
pply apersonel address,please:provide wlth-en erne!!address whirh�can;be.madeaYailatile to the If;you'ere a licensee tinrkr
Chapce(45$F.S.,please click:here'.' -
`ProductApproval'A'cceptsi-
zQlect
SCcurl A1itYitt#:f;
http://www.floridbuilding.orL,/nr/pr apl3,dt.l.aspx?paratn=wGEVXQ.wtDgs%o2fmGFoyT6... 1/14/2016
® Application Instructions for FORMERLY HERITAGE&30
TAMKO HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM
FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY
AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles.
1.ROOF BECK S.FASTENERS
These shingles are for application to roof decks consisting of plywood WIND CAUTION: Extreme wind velocities can damage these
or sheathing boards capable of receiving and retaining fasteners,and shingles after application when proper sealing of the shingles does
to inclines of not less than 2 in.per foot.For roofs having pitches 2 in. not occur.This can especially be a problem if the shingles are applied
per foot to less than 4 in.per foot,refer to special instructions titled in cooler months or in areas on the roof that do not receive direct
"Low Slope Application".For roofs having pitches greater than 21 in. sunlight.These conditions may impede the sealing of the adhesive
per foot,refer to special instructions titled"Mansard Roof or Steep strips on the shingles.The inabilityto seal down maybe compounded
Slope Roof'.Shingles must be applied properly.TAMKO assumes no by prolonged cold weather conditions and/or blowing dust.In these
responsibility for leaks or defects resulting from improper application, situations,hand sealing of the shingles is required.To insure quicker
or failure to properly prepare the surface to be roofed over. sealing, apply 4 quarter-sized dabs of TAM-PRO@ SBS Flashing
Cement,TAMKO or TAM-PROD Plastic Roof Cement, or TAMKO
NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, Tam-Seal Adhesive,meeting ASTM D 4586,Type 1,on the back of
dry and free from warped surfaces.It is recommended that metal the shingle 1 in.(25mm)and 13 in.(330mm)in from each side and
drip edges be installed at eaves and rakes. 1 in.(25mm)up from the bottom of the shingle.Press shingle firmly
PLYWOOD: All plywood shall be exterior grade as defined by into the adhesive.For maximum wind resistance along rakes,install
any TAMKO starter shingle including sealant or cement shingles to
APA - The Engineered Wood Association. Plywood shall be a the underlayment and each other in a 4 in.(102mm)width of TAM-
minimum of 3/8 in.thickness and applied in accordance with the PRO@ SBS Flashing Cement,TAMKO or TAM-PROD Plastic Roof
recommendations of APA-The Engineered Wood Association. Cement,or TAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin
SHEATHING BOARDS: Boards shall be well-seasoned tongue- uniform layer of adhesive less than 1/8 in.(3mm)thick.Excessive
and-groove boards and not over 6 in,nominal width.Boards shall amounts can cause blistering of the shingles and may soften the
be a 1 in. nominal minimum thickness. Boards shall be properly asphalt in certain underlayments resulting in the asphalt flowing,
spaced and nailed. dripping and staining.Shingles must also be fastened according to
the fastening instructions described below.
R.VENTILATION Correct placement of the fasteners is critical to the performance of
the shingle.If the fasteners are not placed as shown in the diagram
Inadequate ventilation of attic spaces can cause accumulation of and described below,this will result in the termination of TAMKO's
moisture in winter months and a build up of heat in the summer, liabilities underthe Limited Warranty.TAMKO will not be responsible
These conditions can lead to: for damage to shingles caused by winds in excess of the applicable
1.Vapor Condensation mph as stated in the Limited Warranty.See Limited Warranty on the
2.Buckling of shingles due to deck movement. wrapper or tamko.com for details.
3.Rotting of wood members. FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from
4.Premature failure of roof. the bottom edge of the shingle,penetrating through the common
bond,and located horizontally as follows:
To insure adequate ventilation and circulation of air,the ventilation 1)Standard Fastening Pattern.(For use on decks with slopes 2
system must include inlets and outlets.This may be accomplished with in.per foot to 21 in.per foot.)One fastener 1 in.from each end and
a combination of ridge and soffit vents or by using gable end vents. one 13-1/2 in.from each end of the shingle for a total of 4 fasteners.
FHA minimum property standards require one square foot of net free (See Standard Fastening Pattern illustrated below).
ventilation area to each 150 square feet of space to be vented.This
may be reduced to one square foot of ventilation area per 300 square STANDARD FASTENING PATTERN
feet if at least 40%and not more than 50%of venting is provided FASTENERS NAIL ZONE
not more than 3 feet below the ridge or if a Class I or II vapor barrier COMMON
BOND
is installed on the warm in winter side of the ceiling in climate zones
6,7,and 8 as recommended by the 2012 International Residential 6-1/811 EXPOSURE 5-5/8'.
Code.For more information consult your design professional.If the
ventilation openings are screened,the total area should be doubled. y .I 12-1/2-1—+—12-3/8"—+— 12-1/2'� �1"
IT IS PARTICULARLY IMPORTANT TO PROVIDE
ADEQUATE VENTILATION. (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8866 1
® (CONTINUED from page 1) FORMERLY HERITAGE@ 30
LTIAIMKOIHICRITAGC®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for
greater than 21 in.per foot.)One fastener 1 in.from each end and reroofing thus allowing a minimum deck penetration of 3/4 in.The
one fastener 8-1/2 in.from each end and one fastener 16 in.from Properly Driven Improperly Driven
each end for a total of 6 fasteners per shingle.(See Mansard and underdriven overdriven crooked
High Wind Fastening Pattern illustrated below.) I. H
MANSARD AND HIGH WIND WARRANTY FASTENING PATTERN —Asphalt
_ Shingles
FASTENERS NAIL ZONE E NI ^—Decking
COMMON
BOND
s a" FEXPCSURES-5/d° crown of the staple must be parallel to the length of the shingle.
The staple crown should be driven flush with the shingle surface.
to+j (.a-trz .jr -irza�r a a +h z-�rzr�-�rz
141-11^ Staples that are crooked,underdriven or overdriven are considered
3)High Wind Warranty Fastening Pattern.(For High Wind Warranty improperly applied.
Application requirements)One fastener 1 in.from each end. One CAUTION: ALL FASTENERS MUST BE DRIVEN INTO THE
fastener 8-1/2 in.from each end and one fastener 16 in.from each NAIL ZONE COMMON BOND AS SHOWN IN THE FASTENING
end for a total of six(6)fasteners per shingle. In addition to this PATTERN DIAGRAMS.
shingle fastening pattern requirement for High Wind Application,
TAMKO also requires the use of TAMKO starter shingles including 4.UNDERWIYMENT
sealant strip at eaves and rakes.Alternatively,along rakes,cement UNDERLAYMENT: An underlayment must be applied over the
shingles to the underlayment and each other in a 4 in. (102 mm) entire deck before the installation of TAMKO shingles.Failure to add
width of TAM-PRO@ SBS Flashing Cement,TAMKO or TAM-PRO@ underlayment can cause premature failure of the shingles which is
Plastic Roof Cement,or TAMKO Tam-Seal Adhesive.Caution:Apply not covered by TAMKO's Limited Warranty.
ONLY a thin uniform layer of adhesive less than 1/8 in.(3mm)thick.
Excessive amounts can cause blistering of the shingles and may Products which are acceptable for use as underlayment are:
soften the asphalt in certain underlayments resulting in the asphalt AAs halt Saturated Felt Underlayments:
flowing,dripping and staining.
• SuperX 30TM Underlayment
High Wind Application is offered on new construction or complete • TAMKO No.15 Asphalt Saturated Organic Felt
tear-off applications only. It is not offered for recover applications. • Any TAMKO non-perforated asphalt saturated organic felt
If High Wind Application requirements are not followed, the High . A non-perforated asphalt saturated organic felt which meets
Wind Application Warranty MPH,as stated on Table I in the Limited ASTM:D226,Type I or II or ASTM D4869
Warranty,reverts to the.Standard Application Wind Warranty MPH
limit. (See Mansard and High Wind Fastening Pattern illustrated Specialty Underlayments:
above.) • Tam-Shield@' Synthetic Underlayment or Synthetic Shield
Underlayment
NAILS:TAMKO recommends the use of nails as the preferred method . TAMKO TW Metal and Tile Underlayment,TW Underlayment
of application. Standard type roofing nails should be used. Nail and Moisture Guard Plus@ (additional ventilation may be
shanks should be made of minimum 12 gauge wire,and a minimum required. Contact TAMKO's Technical Services Department
head diameter of 3/8 in.Nails should be long enough to penetrate for more information.)
3/4 in,into the roof deck.Where the deck is less than 3/4 in,thick, . A self-adhesive underlayment designed for use with asphalt
the nails should be long enough to penetrate completely through shingles which meets ASTM D1970.
plywood decking and extend at least 1/8 in.through the roof deck.
Drive nail head flush with the shingle surface. For Asphalt Saturated Felt Underlayments:
Apply the felt when the deck is dry.On roof decks with slopes
Properly Driven Improperly Driven 4 in:per foot and greater apply the felt parallel to the eaves
afmin diameter unaerdriven everariven crooked lapping each course of the felt over the lower course at least
Asphalt 2 in.Where ends join,lap the felt 4 in.If left exposed,the felt
Shingles
EI s� Decking may be adversely affected by moisture and weathering.Laying
of the felt and the shingle application must be done together.
114•nominal
straight,good penetration, Inadequate lea deep,cuts inadequate For All Other Specialty Underlayments:
and gush with shingle surface pana,rellan Intoshingle anchorage On roof decks with slopes 4 in. per foot and greater apply
the underlayment parallel to the eaves in accordance
STAPLES:If staples are used in the attaching process,follow the with underlayment written application instructions. The
above instructions for placement.All staples must be driven with underlayment should not be left exposed for a longer period of
pneumatic staplers.The staple must meet the following minimum time than is specified in the underlayments written application
dimensional requirements.Staples must be made from a minimum instructions.The final roof covering must be installed before
16 gauge galvanized wire.Crown width must be at least 15/16 in, the structure is exposed to adverse weather conditions,such
(staple crown width is measured outside the legs).Leg length should as wind driven rain,high wind,hail,ice storms,etc. (Continued)
Central District 220 West 4th St., Joplin,MO 64601 800-641-4691 09i19n4
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701.. 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2
® (CONTINUED from page 2) FORMERLY HERITAGEO 30
TAMKO HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
In areas where ice builds up along the eaves or a back-up of water of shingle to start the fourth course and use the remaining 10-3/8
from frozen or clogged gutters is a potential problem, TAMKO's in.piece to begin the fifth course.Continue up the rake in as many
Moisture Guard Plus°, TW Metal and Tile Underlayment or TW rows as necessary using the same formula as outlined above.
Underlayment.(or any specialty eaves flashing product) may be The butt of the shingle should be aligned with the top edge of the
applied eaves,rakes,ridges,valleys,around chimneys,skylights sawtooth of the underlying shingle for a 5-5/8 in. exposure (see
Te dormers
rs to help prevent water damage. Contact TAMKO's shingle application drawing illustrated on this panel). When you
Technical Services Department for more information. make your final cut at the roof's edge,flip any pieces that are 8 in.or
Substitute products as shingle underlayment should not be used. longer back onto the roof.These pieces can be worked in anywhere
S.APPLICATION INSTRUCTIONS without creating zippers or color variations.
NOTE:Do not align joints of shingle courses when working in cut
STARTER COURSE:A starter course may consist of TAMKO Shingle pieces.Joints should be no closer than 4 in.from one another.
Starter,TAMKO 10-inch Starter or self-sealing 3-tab shingles.If self-
sealing 3-tab shingles are used,remove the exposed tab portion and
install with the factory applied adhesive adjacent to the eaves.Attach �Cutyour 5rslcourseshingle toMake 23'and a10313•
length.Cul a second shingle to make a 23'and
the starter course with approved fasteners along a line parallel to a16313•leagth. _
and 1.5 in.to 3 in.above the eaves edge.The starter course should _ -
a
overhang both the eaves and rake edges 1/4 in.to 3/8 in.if drip edge
flashing is not used along the eaves or rakes.If drip edge flashing
is present,install shingles even with the drip edge.
For nwndmum wind resistance alongmkes,install any
TAMKO starter shingle lndudmg sealard or cement shingles '
T umeday Se and each Cherth. A KOmm)M' of -
TAA4ER0S SBS Flashing Cement,TA eaf or TAM-PROS
Elastic Roof Cement,or TAMKO Tem5eal Adhesivo. Undedaymeid Cock \�\
E..
s ve It sti
or
ang
asphalt saturated les
—c
unp
Begin application with a full length mingle.
edge _ _________________________________________________ Then lay your 29',23•,15313•and 10 39°lengths.
\_ As you can sea,rinse shingles with wsm cob
Rake`� make five courses.
Fasteners \
located/-I2"Io 3' Cantlnue working your way across the roof.Wnan you make your
from rake edge --- 3.final at at the root's edge,flip any pieces that are B°or longer
1 back onto p e root.These pieces Can be vro ketl m anywhere without
\ rearing o nets or n joint.variations.
NOTE:Do not align tolnis of shingle eoureps when working In
Start fust strip Wdh l2 shingle Starter strips aveffiang Scif.seating Save Fasteners Ddp edge cut pluses.Joints should be no closer than 4'tram one another.
moved,then foUow with fn' and rakes atlhern- located
shape In order to.Reel with the 1/4'to 313°d no drip edge posdoned 1.12'to 3-
lust shingle course. gashing Is Wesent.If drip along ea1Ks from save edge
edge ga'glc.s—witpresent, or rake edge 6.LOW SLOPE APPLICATION
drip a mingles oven with
tlnp edge.
SHINGLE APPLICATION:Start the first course with a full size shingle On pitches 2 in.per foot to 4 in.per foot cover the deck with two
and overhang the rake edge 1/4 in.if drip edge is not present.If layers of underlayment. Begin by applying the underlayment in a
drip edge is present,align shingle edge with drip edge flashing.Cut 1/2-sheet width along the eaves and overhanging the drip edge
10-3/8 in.from a full shingle to form a shingle 29 in.long.Use this by 1/4 to 3/4 in. Place a full-sheet width over the 1/2-sheet width
to start the second course(see diagram below).Cut a 23 in.long starter piece,completely overlapping it.All succeeding courses will
shingle to start the third course.Use the remaining 16-3/8 in.piece be positioned to overlap the preceding course by 1/2-sheet width.
If winter temperatures average 25aF or less, thoroughly cement
the laps of the entire underlayment to each other with TAM-PRO
or TAMKO Plastic Roof Cement from eaves and rakes to a point
repeat of a least 24 in. inside the interior wall line of the building.As an
eoumea t6 3/8^. a"I ernative,TAMKO's Moisture Guard PlusO,TW Metal and Tile
23 Underlayment, or TW Underlayment self-adhering underlayment
z _ may be used in lieu of the cemented felts.
rake > t 7.MANSARD ROOF OR STEEP SLOPE ROOF
M If the slope exceeds 21 in.per foot(601,each shingle must be sealed
5th course 1 , with TAM-PRO® SBS Flashing Cement, TAMKO or TAM-PRO®
;; 2a 7s ate
4th Bourse Plastic Roof Cement, or TAMKO Tam-Seal Adhesive immediately
163/8 �°"
upon installation.Quarter-sized dabs of cement or adhesive must
3rd.purse be applied to shingles with a 5-5/8 in.exposure,use 6 fasteners per
2ndepurse mss ,. , shingle.See Section 3 for the Mansard Fastening Pattern.
I st course ... "...11. 10.3/8"
fea'e (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3
TAM K ® (CONTINUED from page 3) FORMERLY HERITAGE®30
OHERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
8.RE-ROOFING 9.VALLEY APPLICATION
Before re-roofing,be certain to inspect the roof decks.All plywood shall Over the shingle underlayment,center a minimum 36 in.wide sheet of
meet the requirements listed in Section 1. Moisture Guard Plus",TW Metal&Tile Underlayment,or a minimum
It is not recommended to install laminated asphalt shingles directly 50 Ib. roll roofing in the valley. Nail the underlayment only where
over existing laminated shingles due to the unevenness of the existing necessary to hold it in place and then only nail the outside edges.
multi-layered shingles.The performance of the sealant feature may be IMPORTANT:PRIOR TO INSTALLATION WARM SHINGLES TO
compromised,preventing the shingles from sealing properly.It is PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING
acceptable to install laminated shingles over existing three-tab strip SHINGLES TO FORM VALLEY.
shingles which are flat and essentially intact.Nail down or remove curled
or broken shingles from the existing roof.Replace all missing shingles After valley flashing is in place:
with new ones to provide a smooth base.Shingles that are buckled Apply the first course of shingles along the eaves of one of the
usually indicate warped decking or protruding nails.Hammer down all intersecting roof planes and across the valley.
protruding nails or removethem and refasten in anew location.Remove
all drip edge metal and replace with new. Note:For properflow of water overthe trimmed shingle,always
If re-roofing over an existing roof where new flashing is required to start applying the shingles on the roof plane that has the lower
protect against ice dams(freeze/thaw cycle of water and/or the backup slope or less height.
of water in frozen or clogged gutters),remove the old roofing to a point Extend the end shingle at least 12 in.onto the adjoining roof.
at least 24 in.beyond the interior wall line and applyTAMKO's Moisture Apply succeeding courses in the same manner,extending them
Guard Plus TW Metal and Tile Underfayment,or TW Underlayment. across the valley and onto the adjoining roof.
Contact TAMKO's Technical Services Department for more information.
Measurements will vary when nesting over an existing 5 in.exposure • Press the shingles tightly into the valley.
single roof:Call TAMKO Technical Services for further information. • Use normal shingle fastening methods.
The nesting procedure described below is the preferred method for Note:No fastener should be within 6 in.of the valley centerline,
reroofing over existing metric size shingles with a 5-5/8 in.exposure. and two fasteners should be placed at the end of each shingle
See description below: crossing the valley.
Starter Course:Remove the tabs and an additional portion from the To the adjoining roof plane,apply one row of shingles vertically
head of a full size shingle so that its height is equal to the exposure of facing the valley and 2 in.back from the valley centerline.
the existing shingles.Position the resulting strip over the existing roof
edge(with the factory-applied adhesive strip along the eaves). Cut Note: For a neater installation, snap a chalkline over the
approximately 6 in.from the rake end and apply the remaining portion at shingles for guidance.
the eaves.Continuethe starterstrip byapplying full length shingle strips To complete the valley, apply shingles on the adjoining roof
b
cut to height as above,evenly along the existing roof at the eaves.The plane by positioning the tip of the first shingle a each
existing roof should overhang the eaves far enough to carry water the 2 point from the centerline where the edge of the vrow ertical at
off into the gutter.If this is not the case,cut and apply the starter shingle has been applied,covering the vertical shingle.
strip so that it will provide sufficient overhang for proper drainage.
EnsLng h gIe
Minimum 36°wide sheet Valley centerline
55 s of Moisture Guard Plus I
/ ,� TW Metal& + Extra nail in
0. 131/a \ Tile or 50 Ib.or
ll t'iend of shingle
@, /4 heavier roll roofing - Extend end shingle
00 C
12'-18'beyond
..� valley centerline
Drip edgo
drip edge
New shingles Undedayment .�� No fasteners within
6'of contedine
55/8, 3 5/a'evp—e /
,Xposufe
First Course:Remove an amount from the butt edge of afull-size shingle
so that the remaining portion of the shingle fits between the butts of the /
existing third course.This course must also be applied evenly along the
eaves edge of the new starter strip. Place tip of shingle on the edge of
the vertical shingle,2 inches back
Second and Succeeding Courses:Remove 10-3/8 in.from the rake from valley centerline and covering
end of the first shingle in the second course, and continue with full the vertical shingle.
width shingles for the remainder of the course,placing the top edge of
each new shingle against the butt edge of the old shingle in the course FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
above.This method should create an exposure of 5-5/8 in.afterthe f irst MKO'S TECHNICAL SERVICES DEPARTMENT AT
TA
ACT
course.When beginning the succeeding courses continue to follow the CONTACT
800-641-4691.TTA
Heritage application instructions.(See section 5).
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09119/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4
® (CONTINUED from page 4) FORMERLY HERITAGE@ 30
TAMKO HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
19-111111P AND RIDGE FASTENING DETAIL
Apply the shingles with a 5-1/8 in.exposure beginning at the bottom
of the hip or from the end of the ridge opposite the direction of the
prevailing winds.Secure each shingle with one fastener on each side,
5-5/8 in.back from the exposed end and 1 in.up from the edge.
TAMKO recommends the use of TAMKO Hip & Ridge shingle
products.Where matching colors are available,it is acceptable to
use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces.
Fasteners should be 1/4 in.longer than the one used for shingles
IMPORTANT: PRIOR TO INSTALLATION, CARE NEEDS TO BE
TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
BENDING SHINGLE IN COLD WEATHER.
Direction of prevailing wind
Start 5-1/8"exposure
here— 1
ynl" q
� Fastener
-r -5/8"
)Fn] ,
Start
5-1/8"exposure
THESE. ARE THE MANUFACTURER'S APPLICATION
INSTRUCTIONS FOR THE ROOFING CONDITIONS
DESCRIBED.TAMKO BUILDING PRODUCTS,INC.ASSUMES
NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW
THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE
UNDER THE LIMITED WARRANTY. SEE THE LIMITED
WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS
REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE
CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
800-641-4691.
Information included in these application instructions was current at time of printing.To
obtain a copy of the most current version of these application instructions,visit us online
at tamko.com or call us at 800-641-4691.
TAMKO®,Moisture Guard Plus®,Tam-Shield®,TAM-PRO®and Heritage®are registered
trademarks and SuperX 30 is a trademark of TAMKO Building Products,Inc.
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09119/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701. 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 5
JP69909