Loading...
HomeMy WebLinkAboutDrawing if _. 0 J_s =_=___------! f i 2 1-4 72" X 80" I I I Ii 53" X 80, 13 32" 32" X 80" REPLACE DOOR&SIDELIGHT IN 1 OPENING AND DOORS IN 2 OPENINGS ONLY. JJ�II OPENINGS HAVE EXISTING HURRICANE PROTECTION INSTALLED UNDER PERMIT# SLC-1604-0201 PER HOMEOWNER. j � 1 i I'I I II I I' OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES i COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. I NEG. II 1 53 80 29.44 4 35.5 -38.7 FL15255.10 60.0 -70.0 y FRONT ENTRY-LSMI 2 72 80 40.00 5 34.4 -43.8 FL10976.1 50.0 -50.0 iI( DINING ROOM-LSMI 3 32 80 1 17.78 1 5 1 36.8 -48.6 1 FL15255.9 1 75.0 1-75.0 ill UTILITY/LAUNDRY ROOM-LSMI FL15255.10 - DOOR U-FACTOR:0.15 FL15255.10 - SIDELIGHT-U-FACTOR:0.21, SHGC:0.07 FL10976.1 - U-FACTOR:0.32, SHGC:0.20 i FL15255.10 - DOOR-U-FACTOR:0.15 �II REPLACE EXISTING DOORS&SIDELIGHT AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOOR&SIDELIGHT. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. l I I ;li DOOR FRAME#2 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS'. DOORS&SIDELIGHT IN OTHER OPENINGS TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRET WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOICUMENTSI. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES, MEAN ROOF HEIGHT= 10 FT 8 IN Ii! I li I II SAMUELS RESIDENCE 207 N. 39TH STREET DOOR R :PLACEMENT PLAN FORT PIERCE, FLORIDA I �'I !�iA