HomeMy WebLinkAboutDrawing if
_. 0 J_s
=_=___------! f
i
2
1-4
72" X 80"
I
I
I
Ii
53" X 80,
13
32"
32" X 80"
REPLACE DOOR&SIDELIGHT IN 1 OPENING AND
DOORS IN 2 OPENINGS ONLY. JJ�II
OPENINGS HAVE EXISTING HURRICANE PROTECTION INSTALLED
UNDER PERMIT# SLC-1604-0201 PER HOMEOWNER. j
� 1
i I'I
I
II
I I'
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES i COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. I NEG. II
1 53 80 29.44 4 35.5 -38.7 FL15255.10 60.0 -70.0 y FRONT ENTRY-LSMI
2 72 80 40.00 5 34.4 -43.8 FL10976.1 50.0 -50.0 iI( DINING ROOM-LSMI
3 32 80 1 17.78 1 5 1 36.8 -48.6 1 FL15255.9 1 75.0 1-75.0 ill UTILITY/LAUNDRY ROOM-LSMI
FL15255.10 - DOOR U-FACTOR:0.15
FL15255.10 - SIDELIGHT-U-FACTOR:0.21, SHGC:0.07
FL10976.1 - U-FACTOR:0.32, SHGC:0.20 i
FL15255.10 - DOOR-U-FACTOR:0.15
�II
REPLACE EXISTING DOORS&SIDELIGHT AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOOR&SIDELIGHT.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. l I
I ;li
DOOR FRAME#2 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS'.
DOORS&SIDELIGHT IN OTHER OPENINGS TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRET
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOICUMENTSI.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES,
MEAN ROOF HEIGHT= 10 FT 8 IN Ii!
I li
I II
SAMUELS RESIDENCE
207 N. 39TH STREET DOOR R :PLACEMENT PLAN
FORT PIERCE, FLORIDA
I �'I
!�iA