HomeMy WebLinkAboutProduct Approval (2) 7/1/2015 Florida Building Code Online
17
mow -
HIM-
t} R
Fiariva��'c�1?E�TI`t rit BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts j Publications FBC Staff BCIS Site Map ( Links i Search I
Busines. )
!1 #1 Product
Professi �I � .N� USER:Public User
Regulation
Produrt Approval Menu>Product or Andication Search>Application List>Application Detail
FL# FL1844-R19
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer PGT Industries
Address/Phone/Email 1070 Technology Drive
Nokomis, FL 34275
(941) 486-0100 Ext 22318
druark@pgtindustries.com
Authorized Signature Jens Rosowski
jrosowski@pgtindustries.com
Technical Representative Jens Rosowski
Address/Phone/Email 1070 Technology Drive
Nokomis, FL 34275
(941)486-0100 Ext 21140
jrosowski@pgtindustries.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Horizontal Slider
Compliance Method Certification Mark or Listing
Certification Agency Keystone Certifications, Inc.
Validated By Steven M. Urich, PE
f' Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2011
AAMA/WDMA/CSA 101/I.S.2/A440 2005
AAMA/WDMA/CSA 101/I.S.2/A440 2008
ASTM E-1886 2005
ASTM E-1996 2012
ASTM E-283 2004
ASTM E-330 2002
Equivalence of Product Standards
Certified By
https.-//floridabuilding.org/prlpr_app dtl.aspx?param=wGEVXQwtDgsGsvRHsb6W7CihkBPFyPwC4%2fEUoadW9fJWgOXUIODlbg%3d%3d 1/3
7/1/2015 Florida Building Code Online
Product Approval Method Method 1 Option A
Date Submitted 06/11/2015
Date Validated 06/19/2015
Date Pending FBC Approval
Date Approved 06/27/2015
Summary of Products
FL# Model,Number or Name Description
1844.1 HR-210 Aluminum Horizontal Roller Window with Slip-On Nailing Fn
Limits of Use Certification Agency Certificate
Approved for use In HVHZ: No FL1844 R19 C CAC Certification HR-210.12df
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 01/10/2016
Design Pressure:N/A Installation Instructions
Other: Please see the Installation Instructions for design FL1844 R19 II HR-210.odf
pressure, size and anchorage information. Verified By: A. Lynn Miller, PE 58705
Created by Independent Third Party: No
Evaluation Reports
FL1844 R19 AE HR-210 Evaluation.pdf
Created by Independent Third Party: No
1844.2 HR-410 Vinyl Horizontal Sliding Window
Limits of Use - Certification Agency Certificate
Approved for use in HVHZ: No FL1844 R19 C CAC HR-410 Certification.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 01/29/2016
Design Pressure: N/A Installation Instructions
Other: Please see the Installation Instructions for design FL1844 R19 II HR-410.odf
pressure,size and anchorage information. Verified By: A. Lynn Miller, PE 58705
Created by Independent Third Party: No
Evaluation Reports
FL1844 R19 AE HR-410 Evaluation.odf
Created by Independent Third Party: No
_.y__---
....__................._—...__.._ .__....._....._... _.. __. ............
1844.3 HR-510 WinGuard Vinyl Horizontal Sliding Window
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1844 R19 C CAC [JR-510 Certification odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 11/19/2015
Design Pressure: N/A Installation Instructions
Other: Please see the Installation Instructions for design FI.1844 R19 11 HR-51.0.)d
pressure, size and anchorage information. Verified By: A. Lynn Miller, P.E. 58705
Created by Independent Third Party: No
Evaluation Reports
FLIS44 R19 AE HR-510 Evaluation.odf
Created by Independent Third Party: No
1844.4 HR-2110 Vinyl Horizontal Roller with Integral Nailing Rn
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL1844 R19 C CAC Certification HR-2110.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 02/21/2016
Design Pressure: N/A Installation Instructions
Other: Please see the Installation Instructions for design FL1844 R19 II HR-2110.odf
pressure, size and anchorage information. Verified By: A. Lynn Miller, P.E. 58705
Created by Independent Third Party: No
Evaluation Reports
FL1844 R19 AE HR-2110 Evaluation.odf
Created by Independent Third Party: No
1844.5 HR-2210 7Vinyl Horizontal Roller
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FLIS44 R19 C CAC Certification.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 10/22/2015
Design Pressure: N/A Installation Instructions
Other: Please see the Installation Instructions for design FL1844 R19 II HR-2210Qdf
pressure, size and anchorage information. Verified By: A. Lynn Miller, P.E. 58705
Created by Independent Third Party: No
Evaluation Reports
8L1844 R19 AE HR-2210 Evaluation.odf
Created by Independent Third Party: No
https://fforidabuilding.orgtpr# app M.aspx?param=wGEVXQwtDgsGsvRHsb6W7CihkBPFyPwC4%2fEUoadWgfJWgOXUIODlbg%3d%a3d 213
GENERAL NOTES: ANCHOR_LOCATIONS i
&SPACING
1)THE ANCHORAGE METHODS SHOWN HAVE
BEEN DESIGNED TO COMPLY WITH THE FLORIDA 73"MAX.BUCK(XO/OX) 73"MAX.BUCK(XO/OX)
BUILDING CODE FOR THE DESIGN PRESSURES _-• 110"MAX.BUCK-(XOX) --- --
LISTED. 110"MAX.BUCK(XOX)
2)WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 6-1/4" )
1-112"THICK.1X WOOD BUCKS ARE OPTIONAL IF — MAX
UNIT IS INSTALLED DIRECTLY TO SOLID i
CONCRETE.WOOD BUCKS DEPICTED AS 2X ARE I 1�O.C. I
1-1/2"THICK OR GREATER.ATTACHMENT METHOD I
OF WOOD BUCKS SHALL BE DONE BY OTHERS. —1-
3)SEE TABLES FOR MINIMUM EDGE DISTANCE IMAX."
FROM CENTER OF ANCHOR TO SUBSTRATE EDGE
(EXCLUDING FINISH OR STUCCO). 62"MAX. O.C. 62"MAX.
UC
4)SHIM EACH ANCHOR LOCATION WHERE THE BUCK BK
PRODUCT IS NOT FLUSH TO THE SUBSTRATE, I
USING SHIMS CAPABLE OF TRANSFERRING I
APPLIED LOADS. —
5)ANCHORS SHALL BE COATED OR CORROSION ^ �`
RESISTANT AS APPROPRIATE FOR SUBSTRATE
MATERIAL.DISSIMILAR MATERIALS SHALL BE
PROTECTED AS REQUIRED TO PREVENT
REACTIONS.ALUMINUM SHALL BE PROTECTED
FROM DISSIMILAR MATERIALS AS SPECIFIED IN I 1_3/8• '
THE FLORIDA BUILDING CODE. M1 —� 6-1/8"MAX.O.C. 1-3/8"MAX. {
12-1/4"MAX.O. 6-118-MAX MAX.
6)ADHESIVE SEALANT SHALL BE USED BETWEEN
SUBSTRATE AND FLANGE OR FIN.OVERALL FLANGE FRAME,XO INTEGRAL FIN FRAME,XO
SEALING/FLASHING STRATEGY FOR WATER
RESISTANCE OF INSTALLATION SHALL BE DONE TABLE 2:ANCHORS FOR F
BY OTHERS. TABLE 3:ANCHORS FOR FIN WINDOWS
Min.Edge. Min. Min.Edge Min.
7)MATERIALS USED FOR ANCHOR EVALUATIONS Anchor Substrate Distance Embedment Anchor Substrate Distance Embedment
WERE SOUTHERN PINE,2.7 KSI CONCRETEAND _
CONCRETE MASONRY UNITS COMPLYING WITH P.T.Southern Pine(SG=.55) 112' 1-/8" 2-1/2"x.113"Box Nail P.T.Southern Pine(SG=.55) 5116" 2-7/16"
ASTM C-90.GLAZING COMPLIES WITH ASTM E1300. #10 Sheet Metal Screw, Aluminum,6063.75 min. We" 118" 2-112"x.131"Common Nail P.T.Southern Pine(SG-.55) 318" 2-7116" t
G5 Steel or 410
8)THE 113 STRESS INCREASE WAS NOT USED IN Stainless Steel Steel Stud,Gr.33 min. 318" 0.0346(20 ga) 2-1lT'x.145"Roofing Nail P.T.SouthernPine(SG=.55) 3/8" 2-7l16"
THIS ANCHOR EVALUATION.THE 1.6 LOAD A36 Steel 318" 1/8" P.T.Southern Pine(SG=.55) 1/2" 1-318"
DURATION FACTOR WAS USED FOR THE P.T.Southern Pine(SG=.55) - 1/2" 1-318" Aluminum,6069-T5 min. 3!8" 1/8'
EVALUATION OF WOOD SCREWS. 3/16"Steel Ult2con Concrete(min.2.7 ksi) 1" 1:, #10 Steel SMS Steel Stud,Gr.33 min. 318" 0.0346(20 ga) -
9)IF THE EXACT PRODUCT SIZE IS NOT LISTED IN UngTouted CMU,(ASTM C-90) 1" 1-114" A36 Steel 318" 1/8"
THE TABLES,ALWAYS ROUND UP TO THE NEXT NOTE:FOR ALL METAL SUBSTRATES.SCREW EMBEDMENT SHALL BE MIR 3 THREADS BEYOND INSIDE FACE OF NOTE:FOR ALL METAL SUBSTRATES,SCREW EMBEDMENT SHALL.BEMitt 3THREADS BEYOND INSIDE FACE OFMATERIAL.
LARGER VALUE. MATERIAL.
r
t
(MEET DESIGN PRESSURE y XO SHOWN,SPACING ALSO
Window Buck Size Frame 4.n &190456
APPLIES TO OX AND XOX
Width Height Type Configurat110" 82" FiNFlange XDX(114.112 ;.i. ••.�„ D=wler o:ro,; avma¢ UEf0MWnaKvvM WrAa A=
��:•'��,i:`1fic J.ROSOWSKI 06/22/11 VINYLx®egacumEFRWwrroFwT
amusmrsv.Lw NXS'Peae c>xmaseue
:;:/% Rerm BYr Qa9: RelSrlvx: ANOiRgMIETARY.1pfORTxlllOF7H9
BoawanwruEusmaxRenourmw I
' ::D.:':S i r)J MYrdPe'MD:CU111e<EBR6StD NR(Ra1'
' PEFA'RWY6"➢DrCMlRE3.
^,v,: 1070 TECHNOLOGY DRIVE I
_••, -i�,;
EU NOKOMIS,FL 34275
:'"•�`•.,•%:/OF;1c!';.•.,, j;_�' FLCERT.OF AUTH.:29296 HORIZONTAL ROLLER INSTALLATION I
>1 •i.!i,,:l •� A•Lynn Miller,P.E. Dres*+vMa R°. 1
P.E.#56705 HR-410 NTS 1 of 3 1062211JR
{
EDGE DISTANCE INSTALLATION WITH FLANGE FRAME
— SUBSTRATE EDGE DISTANCE -- �I
EMBEDMENT / 1 � ' SUBSTRATE Q
—�� ,1X WOOD EMBEDMENT EXTERIOR ��
1
\W\ .......
/ �Cl /
SHIM /
O � I
a a
i
FLANGE FRAME,
EXTERIOR JAMB INSTALLATION
EXTERIOR (USING 1X BUCKSTRIP) ;
i
FLANGE FRAME, FLANGE FRAME,
HEAD INSTALLATION HEAD INSTALLATION
(USING 1X BUCKSTRIP) (DIRECTLY TO SUBSTRATE)
EXTERIOR
'
EXTERIOR r EXTERIOR —�
FLANGE FRAME.
JAMB INSTALLATION
(DIRECTLY TO SUBSTRATE)
SHIM SHIM
/�g !,/
SUBSTRATE
/ SUBSTRATE FLANGE FRAME, ,;, •.
SILL INSTALLATION n,,.,,er- m�: M,r�n,r MFBtfG2WrR11f C6Rh'PRaTALgl7At
FLANGE FRAME, (DIRECTLY TO SUBSTRATE) J.ROSOWSKI 06/22/11 VINYL
SILL INSTALLATION � � offi "^"+ a a smrIrsmoa� v
(USING iXBUCKSTRIP)
r�saava7crw.smrs
INSTALLATION NOTES:
w i
1)SEE SHEET 1 FOR SPACING REQUIREMENTS. 1070 TECHNOLOGY DRIVE
2)SEE TABLE 2 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS. NOKOMIS.FL 34275 r e
3)MAX.SHIM THICKNESS TO BE 1/4'. - FL CERT.OF AUTH.:29296 HORIZONTAL ROLLER INSTALLATION
4)GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN REQUIREMENTS, A.Lynn Miller,P.E.
5)FIN AND/OR FLANGE MAYBE REMOVED.FOR EQUAL-LEG FRAME APPLICATIONS,USE FLANGE INSTRUCTIONS. P.E.#58705 HR-410 NTS 2 of 3 1062211JR e
i
INSTALLATION H FIN FRAME
EMBEDMENT
EDGE SUBSTRATE
DISTANCE EXTERIOR
z z
SHIM
EDGE pa❑
DISTANCE
j
EXTERIOR
0
FIN FRAME.
HEAD INSTALLATION
HIM
rt FIN FRAME.
JAMB INSTALLATION SUBSTRATE
IF
�
SHIM it '%
SUBSTRATE
J.ROSOWSKI 06/17/111 VINYL
FIN FRAME,
SILL INSTALLATION
INSTALLATION NOTES: 1070 TECHNOLOGY DRIVE
NOKOMIS,FL 34275
1)SEE SHEET 1 FOR SPACING REQUIREMENTS. I FLCERT.CFAUTH.:29296 HORIZONTAL ROLLER INSTALLATION
2)SEE TABLE 3 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS, A.Lynn Miller,P.E.
3)MAX.SHIM THICKNESS TO BE 1W. P.E.#58705 HR-410 NTS 3 of 3 1062211JR