Loading...
HomeMy WebLinkAboutEngineering FLC) A - ENGINEERING & TESTING, INC. Phone: (866) 781-6889 oFax: (866) 784-8550 -www.foi idaengineeringandtesting.com 250 S.W.13`h Avenue Pompano Beach,FL 33069 DATE: 5/24/16 JOB ORDER#: 16-1620 CLIENT: Freedom Roofers, LLC ADDRESS: 5575 US 1 - Suite# 1 &2 Vero Beach,FL 32967 PROJECT: Kelly Casson Sloped Roof Deck(Slope: 5/12) ADDRESS: 868 Noa Street Fort Pierce,FL FBC 2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Height=<15' Exposure: C Basic/Ultimate Wind Speed: V,dt=170 mph Length= 60' Category: II Nominal Wind Speed: Vasd=Vi1t*.0.6 Width= 58' Slope: 5/12=22.6° (asd=allowable strength design) Parapet Wall: N/A Residential KZ=0.85, Kzt= 1.0, Kd=0.85 Design Calculations: Velocity Pressure: q=0.00256*KZKztKdV2 Velocity Pressure (,dt): q=0.00256(0.85)(1.0)(0.85)(170)2] =53.45 psf Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(170*.0.6)2] =32.07 psf Width of Pressure Coefficient: 0.1(58') = 5.8' 0.4(15') = 6.0' } use: 6'0" Effective Wind Area: <10ft2 External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -0.9 1) GCP; = 0.18 2) GCP2 = -1.7 3) GCP3 = -2.6 Design Pressures Based on Vasd: 1) Field P1 = 32.07*[(-0.9)—(0.18)] =-34.6 psf 2) Perimeter P2 = 32.07*[(-1.7)—(0.18)] =-60.3 psf 3) Corners P3 = 32.07*[(-2.6)—(0.18)] =-89.2 psf 'v'Q v Quality`'4 Aye.4awrance Page 2,5/24/16,Job Order#16-1620 iWreedom Roofers,LLC-Kelly Casson Residence FTso 1� Sloped Roof Deck(Slope:5/12) 868 Noa Street;Fort Pierce,FL: Attachment Requirements: Based on the requirements of Florida Product Approval # 17796.6, Table A with maximum design pressures of -108.5psf and -156.5psf; the following are our recommended fastening patterns to attach the 26 ga.. 5V Crimp Roof Panel to the minimum 15/32 or greater thick plywood decking utilizing#9-15 x 1-1/2" WoodZac with Zac Head with sealing washing through panel rib with 1/4" minimum penetration through plywood at the following fastener patterns and fastener spacing: Zone(s) Field(1) , Perimeter(2) & Corners (3) Max. Total Uplift -108.5 psf Design Pressure Fastener Pattern Panel Rib Fastener Row Spacing 12" o.c. Notes: Corners and perimeter (edge, hip, &ridge) area dimension shall not be less than a = 60" (Zone 2: Perimeter is a 6'0" wide strip, Zone 3: Corners are 6'0" x 61011) Our engineering attachment analysis is limited to uplift resistance only, therefore, it does not include waterproofing or aesthetic concerns as applicable. Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE 7-10, FBC 2014 and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer(or authorized } representative) or a building department inspector to verify compliance with specifications bar m ,p s 'Mak A Mesiano" Flonda Erigineermg&Testing, Inc. > r� F�'londa Reg:No 48;202 ,Certificate of Authorization No. 6923 � Err �trrl inrrtict n` .< .. Florida Bw1ding Code Online http://www. oridabtakling.org/pripr_app ad aVx?pmam--wGE... ASTM D3909 1997 ASTM D4869 2005 ASTM D6164 2005 ASTM D6380 2003 FM 4474 2004 FkSA/TRI April 2012(04-12) 2012 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 12/17/2015 Date Validated 12/17/2015 Date Pending FSC Approval 12/21/2015 Date Approved 02/10/2016 Date Revised 04/18/2016 Summary of Products fL# Model,Number far Name Description 10450.1 Taroo Roof Underiayments Roof underiayments for use in prepared roof assemblies Limits of use Installation Instructions Approved for use In HVHZ:No 115t 2 FINAL ER_TARCO UNDERt_aYMENTS F11045Q- Approved for use outside HVHZ:Yes R7.odf Impact Resistant:N/A Verified By:Robert Nleminen PE-59166 Design Pressure:+N/A/-217.5 Created by Independent Third Party:Yes Other.1.)The design pressure herein pertains Evaluation Reports to one particular bonded underlayment EL104M R7 AE 2015 12 FINAL R TARCO UNDERILAYMENTS 1"22- appiication for use beneath adhesiveset tile R7R7=odf systems.Refer to ER Section 5.6.2 for details, Created by Independent Third Party:Yes and other bonded underlayment systems.2.) Refer to ER Section 5 for Limits of Use. Back Nmtt Con Us::1440 North Monroe Street.Tanahassee R 32399 Phone:850487-1929 The State of Florida is an AA/M employe'. rnrieht;007-2013 State of Florida.::.Privacy Statement:;gmegisibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mall address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any Questions.Please contact 950.487.1995."Pursuant to section 455.275(1I Florida statutes,effective October 1,2012,licensees licensed under chapter 455,F.S.must provide the Department with an email address if they have one.The emalis provided may ire used forefftcial communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please cikk bp=. ProductAppre»r Aceepbs: Ej WR ECtY.I Im >,yurity':i Ii,ti s C �VL 2 of 2 4/19/16,10:03 AM