Loading...
HomeMy WebLinkAboutbuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 j Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT APPLICATION FOR: Roof I PROPOSED.:IMPROVEMENT LOCATION Address: 10851 S OCEAN DR #59 Legal Description: WINDMILL VILLAGE BY -THE -SEA CONDOMINIUM NO 1 UNIT 59 AND PRO -RATA SHARE IN COMMON ELEMENTS (OR 459-1637) Property Tax ID #: 4511-810-0066-000-8 Lot No. Site Plan Name: Block No Project Name: REGAN RESIDENCE Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORK: REROOF/REMOVE EXISITNG SHINGLE ROOF AND INSTALL A NEW SHINGLE ROOF PITCH 4/12 1800SQFT 4,500$ CONSTRUCTION INFORMATION: Additional work RGas Tank Gas Pip[ check all _ Shutters Wind C ork to be ertormed under this permit — the _ _ ❑ p g Windows/Doors 11 Electric ❑ Plumbing 11 Sprinklers FIGenerator 1-7 Roof Total Sq. Ft of Construction: 1800 Sq. of First Floor: Cost of Construction: $ 4,500 Utilities: L _I Sewer Septic Building Height: OWNER/LESSEE: Name JEAN HALEY Address: 3916 GATWICK DR, City: TROY State: Ml Zip Code: 48083 Fax: Phone No. 248-709-9281 E -Mail: Fill in fee simple Title Holder on next page (if different from the Owner listed above) CONTRACTOR: ' , � Name: JOSEPH KOLINOSKI Company: ONSHORE ROOFING SPECIALISTS, INC Address: 4401 SE COMMERCE AVE I City: STUART State: FL Zip Code: 34996 Fax: Phone No. 772-283-1505 E -Mail: INFO@ONSHOREROOFING.COM State or County License: CCC1328994 if value of construction is $2500 or more, a RECORDED Notice of Commencement is required. ENTALtONSTRLI C®SVS EN LAW INFORMATION-. CTIC��i LI - DESIGNER ENGI pp MORTGAGE COMPANY: _ Not Applicable / NEER: _ Not Applicable cable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and ted on the jobsite before the first inspectl.ot�,„1f_.you intend to obtain financing, consult with len t oat torney before commencing work or rotor rng�yaur Notice of Commencement. Ir'f / Agent The forgoing instrument was acknowledg d before me tl i ay of 201 by (Name of person acknowled in ) dd �i (Signature of Notary Public:,5taf-e of Florida ) Personally Known OR Produced Identification Type of Identification Produced Commission No.(Seale"j``l��9 Mors? %U!J Revised 07/15121014_"`^ REVIEWS FRONT ZONING COUNTER REVIEW DATE COMPLETE INITIALS - s Signature of / 'ydc cense Holder The orgoing instrum nt was acknowledged before me thi day of 20 by _ C (d A (N me�f p_rs n acknowledgidl� (Signature of Notary Public State of Florida ) Personally Known OR Produced Identification Type of Identification Produced - Commission No. (Se�l!)'u 'a_,w G ;-1 i.° SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE REVIEW REVIEW REVIEW REVIEW REVIEW MIS [ : , ` 1' ""`"" MIAMI-iDADE COUNTY PRODUCT CON'T'ROL SECTION (DEPARTMENT OF RE, GULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 TICS OF ACCEPTANCE (NOA) itiivw.miamidade.Eiov/economv Iko Industries Ltd. 40 Hansen Tad. S. Brampton, Ontario CANADA L6W3H4 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Cambridge, Cambridge III), and Biltmore AR Asphalt Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-0517.09 and consists of pages 1 through 4 The submitted documentation was reviewed by Alex Tigera. fMI�AM COUNT 110MU&M4 NOA No.: 14-0603.02 Expiration Date: 05/05/16 Approval Date: 01/22/15 Page 1 of 4 Categorv: Roofing Sub -Cate o . Asphalt Shingles Materials Laminate Deck Tvme: Wood SCOPE This approves a roofing system using Cambridge AR, Cambridge FID, and Biltmore AR asphalt shingles manufactured by IKO Industries Ltd. as described in Section 2 of his Notice of Acceptance. aMITIMTE"'T.T-7177T17, Product Cambridge Mand. Loc. #1, 2, 3 Cambridge FID Manzif Loc. #1, 2, 3 Biltmore AR Manuf. Loc. #1, 2 1. Kankakee, IL 2. Wilmington, DE 3. Sylacuaga, AL. Dimensions Test Product DeseriDtion SDecifications 13 3/4" x 40'/8" TAS 110 A heavy weight, fiberglass reinforced laminate asphalt shingle. 13 3/4" x 40'/8" TAS 110 A heavy weight, fiberglass reinforced laminate asphalt shingle. 13 '/4" x 40'/8" TAS 110 A heavy weight, fiberglass reinforced laminate asphalt shingle. Test Agency Test Identifier Test Name/Renori Date PRI Construction Materials Inc. IKO-050-02-01 TAS 100 12/21/09 M0-076-02-01 TAS 100 02/21/12 IKO-114-02-01 TAS 100 09/25/14 IKO-099-02-01 TAS 100 05/12/14 IKO-096-02-01 ASTM D 3462 09/27/13 IKO-095-02-01 ASTM D 3462 09/27/13 IKO-121-02-01 ASTM D 3462 09/25/14 II,,' -O-100-02-01 ASTM D 3161 (TAS -107) 05/21/14 IKO-115-02-01 ASTM D 3161 (TAS -107) 09/25/14 FM Approvals 3041689 ASTM D 3462 02/23/11 3036971 ASTM D 3161 (TAS -107) 01/04/09 3042673 ASTM E 108 04/12/11 �iAr��•®auE N®A No.: fl4-0603.02 couN-ry ® , Expiration Date: 05/05/16 Approval Date: 01/22/15 Page 2 of 4 I . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W, attached. 5. Nailing shall be in compliance with Detail W, attached. 1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". °'��� 9ifPlj'llr�`111�1`ii(S�LMIg!' PilAldlI•DADE COUNTY ®r o Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 14-0603.02 MIAMI•®ADE COUNTV ®r 1 Expiration Date: 05/05/16 Approval Date: 01/22/15 Page 3 of 4 DETAIL A CAMBRIDGE, CAMBRIDGE HD, BILTMoRE AR COURSE LAYOUT ,,—EDGE OF ROOF ------------ '4" ------------ ------ MIN, 4" ------------ iiii =IRST COURSE ",';',;;%;) (� / / Note: Roofing Cement not shown in this layout. This drawing is for course layout only. See Detail B for nailing and cement placement details. THIRD COURSE 11 13 SECOND COURSE 6 31t 8 DETAIL B CAMBRIDGE, CAMBRIDGE HD, BILTMoRE AR 34 11 13 6 31t 8 40 7u 8 01 5$" EXPOSURE 1 NOA No.: 14-0603.02 �MIAWIDAJDE C ® 1u, Expiration Date: 05/05/16 =11Approval Date: 01/22/15 Page 4 of 4 Florida Building Code Online Page 1 of 4 - ,.w.wg�- ��.' a i v , sf � r � D a h� 5'„ �`�''"'��f G T �ti' �.k�.`" '-�_�='�` • --_- ?��5, MN �Ofida Departmewd BCIS Home Log In { User Registration Hot Topics i Submit Surcharge Stats & Pacts Publications �, FBC Staff •i BCIS Site Map I Linla; j •Search Busines�� OUSER:'rofessiA�')I Product Approval Public User Regulation t Product AnDraval Menu > Product or Arellmtion Search > Application List > Application Detail FL # FL12328-R3 Application Type Editorial Change Code Version 2010 Application Status Approved Comments Archived 10 Product Manufacturer TAMKO Building Products, Inc. Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kerri Eden kerri_eden@tamlco.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerrj_eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Test Report Testing Lab PRI Construction Materials Technologies, LLC Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/26/2016 Validated By Robert J. M. Nieminen, PE 2 Validation Checklist - Hardcopy Received Certificate of Independence FL12328 R3 COI PRI CMT Cert of IndeDendence.Ddf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D4869 2005 ASTM D6380 2003 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option B h"://www.floridabuildin2.orR/Dr/nr ap-o dtl.asbx?naram=wGEVXOwtDatF2Aezuarig0l_.. 5/15/2014 Florida .Building Code Online Date Submitted 03/04/2013 Date Validated 03/11/2013 Date Pending FBC Approval 04/15/2013 Date Approved 06/11/2013 Summary of Products FL ## I Model, Number or Name Description 12328.1 I ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use on roofs with slopes greater than 2:12. Not approved for use in HVHZ. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. 12328.2 I ASTM Tile Underlayment Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Maximum 30 day exposure. 12328.3 I Master Smooth Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Maximum 30 day exposure. 12328.4 ( Moisture Guard Plus Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not For use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Maximum 90 day exposure. 12328.5 1 Nail Fast Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA[TRI 07320/8 for underlayment options with tile roof systems. Maximum 30 day exposure. Page 2 of 4 Installation Instructions FL12328 R3 II sl surf aoo ins.odf Verified By: Robert]. M. Nieminen 59166 Test Reports FL12328 R3 TR 2010 Referenced Standards Evaluation for TAMKO 10 03 2011.ndf FL12328 R3 TR astm slate surfaced roll rfo.odf Coated organic underlayment Installation Instructions FL12328 R3 II UNDERLAYMENT.odf Verified By: Robert 3. M. Nieminen 59166 Test Reports FL12328 R3 TR 2010 Referenced Standards Evaluation for TAMKO 10 03 2011.odf FL12328 R3 TR astm tile underlavment reoort.DdF Asphalt saturated organic underlayment. Installation Instructions FL12328 R3 II UNDERLAYMENT.Ddf Verified By: Robert 3. M. Nieminen 59166 Test Reports FL12328 R3 TR 2010 Referenced Standards Evaluation for TAMKO 10 03 2011.Ddf FL12328 R3 TR master smooth reoort.odf A self -adhering modified bitumen underlayment. Installation Instructions FL12328 R3 II moo aoo inst.odf Verified By: Robert 3. M. Nieminen 59166 Test Reports FL12328 R3 TR moisture ouard olus reoort.odf SBS modified utility underlayment Installation Instructions FL12328 R3 I1 nailfast aoo ins.odf Verified By: Roberti. M. Nieminen 59166 Test Reports FL12328 R3 TR 2010 Referenced Standards Evaluation for TAMKO 10 03 2011.odf FL12328 R3 TR nail Fast reoort.odf 12328.6 I No. 15 ASTM D4869 Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R3 II UNDERLAYMENT.odf Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166 Impact Resistant: N/A Test Reports Design Pressure: N/A FL12328 R3 TR no 15 astm d4869 reoort.odf Other: For use under discontinuous roofing systems i,e. asphalt shingles with slopes greater than 2:12. Not littp://www.floridabuildinR.or2/pr/pr app dtl.asnx?naranl=wGEVXOwtDatF2Ae7,Ilarig0l._. 5/15/7014 Florida Building Code Online approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Shall be covered as soon as possible after installation; exposure for more than 24 hours could affect performance. 12328.7 I No. 15 UL Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with the roof systems. Shall be covered as soon as possible after installation; exposure for more than 24 hours could affect performance. 12328.8 I No. 30 ASTM Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tie. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Shall be covered as soon as possible after installation; exposure for more than 24 hours could affect performance. 12328.9 I No. 30 ASTM D4869 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved for use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Shall be covered as soon as possible after installation; exposure for more than 24 hours could affect performance. 12328.10 1 No. 30 UL Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: For use under discontinuous roofing systems i.e. asphalt shingles with slopes greater than 2:12. Not approved For use in HVHZ. Not for use as a substrate for adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for underlayment options with tile roof systems. Shall be covered as soon as possible after Installation; exposure for more than 24 hours could affect performance. Page 3 of 4 Asphalt saturated organic felt Installation Instructions FL12328 R3 II UNDERLAYMENT.odf Verified By: Robert J. M. Nieminen 59166 Test Reports FL12328 R3 TR no 15 ul reoort.odf Asphalt saturated organic felt Installation Instructions FL12328 R3 II UNDERLAYMENT.odf Verified By: Robert J. M. Nieminen 59166 Test Reports FL12328 R3 TR no 30 astm renort.odf Asphalt saturated organic felt Installation Instructions FL12328 R3 II UNDERLAYMENT.odf Verified By: Robert J. M. Nieminen 59166 Test Reports FL12328 R3 TR no 30 astm d 4869 reoort.odf Asphalt saturated organic felt Installation Instructions FL12328 R3 II UNDERLAYMENT.odf Verified By: Robert J. M. Nieminen 59166 Test Reports FL12328 R3 TR no 30 ul reoort.odf E- -9 Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Privacv Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: m E - redIN Wk. htti)://www.floridabuildine.ora/Dr/nr anti dtl.asiux?naram=wC7FVXnwtT)otF2Ae7,IlariPF01_.. 5/15/?n74 Florida Building Code Online Page 4 of 4 litt-p://www.floridabuildinR.orR/Dr/Draoo dd o(] '. 5/15/2014 UNDERLAYMENT: An underlayment consisting of asphalt saturated felt must be applied over the entire deck before the installation of TAMKO shingles. Apply the felt when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the eaves lapping each course of the felt over the lower course at least 2 in. Where ends join, lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by moisture and weathering. Laying of the underlayment and the shingle application must be done together. CORPORATE HEADQUARTERS 220 W. FOURTH STREET P.O. BOX 1404 JOPLIN, MO 64802-1404 800-641-4691 tamko.com