HomeMy WebLinkAboutbuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
j Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X
PERMIT APPLICATION FOR: Roof I
PROPOSED.:IMPROVEMENT LOCATION
Address: 10851 S OCEAN DR #59
Legal Description:
WINDMILL VILLAGE BY -THE -SEA CONDOMINIUM NO 1 UNIT 59 AND PRO -RATA SHARE IN COMMON ELEMENTS (OR 459-1637)
Property Tax ID #: 4511-810-0066-000-8 Lot No.
Site Plan Name: Block No
Project Name: REGAN RESIDENCE
Setbacks Front Back: Right Side: Left Side:
DETAILED DESCRIPTION OF WORK:
REROOF/REMOVE EXISITNG SHINGLE ROOF AND INSTALL A NEW SHINGLE ROOF
PITCH 4/12 1800SQFT
4,500$
CONSTRUCTION INFORMATION:
Additional work
RGas Tank Gas Pip[ check all _ Shutters Wind C
ork to be ertormed under this permit — the
_ _ ❑ p g Windows/Doors
11 Electric ❑ Plumbing 11 Sprinklers FIGenerator 1-7 Roof
Total Sq. Ft of Construction: 1800 Sq.
of First Floor:
Cost of Construction: $ 4,500 Utilities: L _I Sewer Septic Building Height:
OWNER/LESSEE:
Name JEAN HALEY
Address: 3916 GATWICK DR,
City: TROY State: Ml
Zip Code: 48083 Fax:
Phone No. 248-709-9281
E -Mail:
Fill in fee simple Title Holder on next page (if different
from the Owner listed above)
CONTRACTOR: ' , �
Name: JOSEPH KOLINOSKI
Company: ONSHORE ROOFING SPECIALISTS, INC
Address: 4401 SE COMMERCE AVE I
City: STUART State: FL
Zip Code: 34996 Fax:
Phone No. 772-283-1505
E -Mail: INFO@ONSHOREROOFING.COM
State or County License: CCC1328994
if value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
ENTALtONSTRLI
C®SVS
EN LAW INFORMATION-.
CTIC��i LI -
DESIGNER ENGI pp MORTGAGE COMPANY: _ Not Applicable
/ NEER: _ Not Applicable cable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone: Zip: Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and ted on the jobsite
before the first inspectl.ot�,„1f_.you intend to obtain financing, consult with len t oat
torney before
commencing work or rotor rng�yaur Notice of Commencement. Ir'f /
Agent
The forgoing instrument was acknowledg d before me
tl i ay of 201 by
(Name of person acknowled in )
dd
�i
(Signature of Notary Public:,5taf-e of Florida )
Personally Known OR Produced Identification
Type of Identification Produced
Commission No.(Seale"j``l��9
Mors?
%U!J
Revised 07/15121014_"`^
REVIEWS FRONT ZONING
COUNTER REVIEW
DATE
COMPLETE
INITIALS
- s
Signature of / 'ydc cense Holder
The orgoing instrum nt was acknowledged before me
thi day of 20 by
_ C (d A
(N me�f p_rs n acknowledgidl�
(Signature of Notary Public State of Florida )
Personally Known OR Produced Identification
Type of Identification Produced -
Commission No. (Se�l!)'u 'a_,w G ;-1
i.°
SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE
REVIEW REVIEW REVIEW REVIEW REVIEW
MIS [
: , ` 1' ""`""
MIAMI-iDADE COUNTY
PRODUCT CON'T'ROL SECTION
(DEPARTMENT OF RE, GULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
TICS OF ACCEPTANCE (NOA)
itiivw.miamidade.Eiov/economv
Iko Industries Ltd.
40 Hansen Tad. S.
Brampton, Ontario CANADA
L6W3H4
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Cambridge, Cambridge III), and Biltmore AR Asphalt Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA #11-0517.09 and consists of pages 1 through 4
The submitted documentation was reviewed by Alex Tigera.
fMI�AM COUNT
110MU&M4
NOA No.: 14-0603.02
Expiration Date: 05/05/16
Approval Date: 01/22/15
Page 1 of 4
Categorv:
Roofing
Sub -Cate o .
Asphalt Shingles
Materials
Laminate
Deck Tvme:
Wood
SCOPE
This approves a roofing system using Cambridge AR, Cambridge FID, and Biltmore AR asphalt shingles
manufactured by IKO Industries Ltd. as described in Section 2 of his Notice of Acceptance.
aMITIMTE"'T.T-7177T17,
Product
Cambridge
Mand. Loc. #1, 2, 3
Cambridge FID
Manzif Loc. #1, 2, 3
Biltmore AR
Manuf. Loc. #1, 2
1. Kankakee, IL
2. Wilmington, DE
3. Sylacuaga, AL.
Dimensions Test Product DeseriDtion
SDecifications
13 3/4" x 40'/8" TAS 110 A heavy weight, fiberglass reinforced laminate
asphalt shingle.
13 3/4" x 40'/8" TAS 110 A heavy weight, fiberglass reinforced laminate
asphalt shingle.
13 '/4" x 40'/8" TAS 110 A heavy weight, fiberglass reinforced laminate
asphalt shingle.
Test Agency
Test Identifier
Test Name/Renori
Date
PRI Construction Materials Inc.
IKO-050-02-01
TAS 100
12/21/09
M0-076-02-01
TAS 100
02/21/12
IKO-114-02-01
TAS 100
09/25/14
IKO-099-02-01
TAS 100
05/12/14
IKO-096-02-01
ASTM D 3462
09/27/13
IKO-095-02-01
ASTM D 3462
09/27/13
IKO-121-02-01
ASTM D 3462
09/25/14
II,,' -O-100-02-01
ASTM D 3161 (TAS -107)
05/21/14
IKO-115-02-01
ASTM D 3161 (TAS -107)
09/25/14
FM Approvals
3041689
ASTM D 3462
02/23/11
3036971
ASTM D 3161 (TAS -107)
01/04/09
3042673
ASTM E 108
04/12/11
�iAr��•®auE N®A No.: fl4-0603.02
couN-ry
® , Expiration Date: 05/05/16
Approval Date: 01/22/15
Page 2 of 4
I . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
5. Nailing shall be in compliance with Detail W, attached.
1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product Control Approved".
°'��� 9ifPlj'llr�`111�1`ii(S�LMIg!'
PilAldlI•DADE COUNTY
®r o
Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 14-0603.02
MIAMI•®ADE COUNTV
®r 1 Expiration Date: 05/05/16
Approval Date: 01/22/15
Page 3 of 4
DETAIL A
CAMBRIDGE, CAMBRIDGE HD, BILTMoRE AR COURSE LAYOUT
,,—EDGE OF ROOF
------------
'4"
------------
------ MIN,
4"
------------
iiii
=IRST COURSE ",';',;;%;) (� / /
Note: Roofing Cement not shown in this layout.
This drawing is for course layout only. See Detail B
for nailing and cement placement details.
THIRD COURSE
11
13
SECOND
COURSE
6 31t
8
DETAIL B
CAMBRIDGE, CAMBRIDGE HD, BILTMoRE AR
34
11
13
6 31t
8
40 7u
8
01
5$" EXPOSURE
1
NOA No.: 14-0603.02
�MIAWIDAJDE C
® 1u, Expiration Date: 05/05/16
=11Approval Date: 01/22/15
Page 4 of 4
Florida Building Code Online Page 1 of 4
-
,.w.wg�-
��.'
a i v , sf � r � D a h� 5'„ �`�''"'��f G T �ti' �.k�.`" '-�_�='�` • --_-
?��5, MN
�Ofida Departmewd BCIS Home Log In { User Registration Hot Topics i Submit Surcharge Stats & Pacts Publications �, FBC Staff •i BCIS Site Map I Linla; j •Search
Busines�� OUSER:'rofessiA�')I Product Approval
Public User
Regulation
t Product AnDraval Menu > Product or Arellmtion Search > Application List > Application Detail
FL # FL12328-R3
Application Type Editorial Change
Code Version 2010
Application Status Approved
Comments
Archived 10
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamlco.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerrj_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Test Report
Testing Lab PRI Construction Materials Technologies, LLC
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 02/26/2016
Validated By Robert J. M. Nieminen, PE
2 Validation Checklist - Hardcopy Received
Certificate of Independence FL12328 R3 COI PRI CMT Cert of IndeDendence.Ddf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2001
ASTM D226
2006
ASTM D4869
2005
ASTM D6380
2003
Equivalence of Product Standards
Certified By
Product Approval Method
Method 1 Option B
h"://www.floridabuildin2.orR/Dr/nr ap-o dtl.asbx?naram=wGEVXOwtDatF2Aezuarig0l_.. 5/15/2014
Florida .Building Code Online
Date Submitted
03/04/2013
Date Validated
03/11/2013
Date Pending FBC Approval
04/15/2013
Date Approved
06/11/2013
Summary of Products
FL ## I Model, Number or Name Description
12328.1 I ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use on roofs with slopes greater than 2:12. Not
approved for use in HVHZ. Refer to FRSA/TRI 07320/8 for
underlayment options with tile roof systems.
12328.2 I ASTM Tile Underlayment
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use under discontinuous roofing systems i.e.
asphalt shingles with slopes greater than 2:12. Not
approved for use in HVHZ. Refer to FRSA/TRI 07320/8 for
underlayment options with tile roof systems. Maximum 30
day exposure.
12328.3 I Master Smooth
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use under discontinuous roofing systems i.e.
asphalt shingles with slopes greater than 2:12. Not
approved for use in HVHZ. Not for use as a substrate for
adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for
underlayment options with tile roof systems. Maximum 30
day exposure.
12328.4 ( Moisture Guard Plus
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use under discontinuous roofing systems i.e.
asphalt shingles with slopes greater than 2:12. Not
approved for use in HVHZ. Not For use as a substrate for
adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for
underlayment options with tile roof systems. Maximum 90
day exposure.
12328.5 1 Nail Fast
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use under discontinuous roofing systems i.e.
asphalt shingles with slopes greater than 2:12. Not
approved for use in HVHZ. Not for use as a substrate for
adhesive -set roof tile. Refer to FRSA[TRI 07320/8 for
underlayment options with tile roof systems. Maximum 30
day exposure.
Page 2 of 4
Installation Instructions
FL12328 R3 II sl surf aoo ins.odf
Verified By: Robert]. M. Nieminen 59166
Test Reports
FL12328 R3 TR 2010 Referenced Standards Evaluation for
TAMKO 10 03 2011.ndf
FL12328 R3 TR astm slate surfaced roll rfo.odf
Coated organic underlayment
Installation Instructions
FL12328 R3 II UNDERLAYMENT.odf
Verified By: Robert 3. M. Nieminen 59166
Test Reports
FL12328 R3 TR 2010 Referenced Standards Evaluation for
TAMKO 10 03 2011.odf
FL12328 R3 TR astm tile underlavment reoort.DdF
Asphalt saturated organic underlayment.
Installation Instructions
FL12328 R3 II UNDERLAYMENT.Ddf
Verified By: Robert 3. M. Nieminen 59166
Test Reports
FL12328 R3 TR 2010 Referenced Standards Evaluation for
TAMKO 10 03 2011.Ddf
FL12328 R3 TR master smooth reoort.odf
A self -adhering modified bitumen underlayment.
Installation Instructions
FL12328 R3 II moo aoo inst.odf
Verified By: Robert 3. M. Nieminen 59166
Test Reports
FL12328 R3 TR moisture ouard olus reoort.odf
SBS modified utility underlayment
Installation Instructions
FL12328 R3 I1 nailfast aoo ins.odf
Verified By: Roberti. M. Nieminen 59166
Test Reports
FL12328 R3 TR 2010 Referenced Standards Evaluation for
TAMKO 10 03 2011.odf
FL12328 R3 TR nail Fast reoort.odf
12328.6 I No. 15 ASTM D4869 Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL12328 R3 II UNDERLAYMENT.odf
Approved for use outside HVHZ: Yes Verified By: Robert J. M. Nieminen 59166
Impact Resistant: N/A Test Reports
Design Pressure: N/A FL12328 R3 TR no 15 astm d4869 reoort.odf
Other: For use under discontinuous roofing systems i,e.
asphalt shingles with slopes greater than 2:12. Not
littp://www.floridabuildinR.or2/pr/pr app dtl.asnx?naranl=wGEVXOwtDatF2Ae7,Ilarig0l._. 5/15/7014
Florida Building Code Online
approved for use in HVHZ. Not for use as a substrate for
adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for
underlayment options with tile roof systems. Shall be
covered as soon as possible after installation; exposure for
more than 24 hours could affect performance.
12328.7 I No. 15 UL
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use under discontinuous roofing systems i.e.
asphalt shingles with slopes greater than 2:12. Not
approved for use in HVHZ. Not for use as a substrate for
adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for
underlayment options with the roof systems. Shall be
covered as soon as possible after installation; exposure for
more than 24 hours could affect performance.
12328.8 I No. 30 ASTM
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use under discontinuous roofing systems i.e.
asphalt shingles with slopes greater than 2:12. Not
approved for use in HVHZ. Not for use as a substrate for
adhesive -set roof tie. Refer to FRSA/TRI 07320/8 for
underlayment options with tile roof systems. Shall be
covered as soon as possible after installation; exposure for
more than 24 hours could affect performance.
12328.9 I No. 30 ASTM D4869
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use under discontinuous roofing systems i.e.
asphalt shingles with slopes greater than 2:12. Not
approved for use in HVHZ. Not for use as a substrate for
adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for
underlayment options with tile roof systems. Shall be
covered as soon as possible after installation; exposure for
more than 24 hours could affect performance.
12328.10 1 No. 30 UL
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use under discontinuous roofing systems i.e.
asphalt shingles with slopes greater than 2:12. Not
approved For use in HVHZ. Not for use as a substrate for
adhesive -set roof tile. Refer to FRSA/TRI 07320/8 for
underlayment options with tile roof systems. Shall be
covered as soon as possible after Installation; exposure for
more than 24 hours could affect performance.
Page 3 of 4
Asphalt saturated organic felt
Installation Instructions
FL12328 R3 II UNDERLAYMENT.odf
Verified By: Robert J. M. Nieminen 59166
Test Reports
FL12328 R3 TR no 15 ul reoort.odf
Asphalt saturated organic felt
Installation Instructions
FL12328 R3 II UNDERLAYMENT.odf
Verified By: Robert J. M. Nieminen 59166
Test Reports
FL12328 R3 TR no 30 astm renort.odf
Asphalt saturated organic felt
Installation Instructions
FL12328 R3 II UNDERLAYMENT.odf
Verified By: Robert J. M. Nieminen 59166
Test Reports
FL12328 R3 TR no 30 astm d 4869 reoort.odf
Asphalt saturated organic felt
Installation Instructions
FL12328 R3 II UNDERLAYMENT.odf
Verified By: Robert J. M. Nieminen 59166
Test Reports
FL12328 R3 TR no 30 ul reoort.odf
E- -9 Next
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Privacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
m E -
redIN Wk.
htti)://www.floridabuildine.ora/Dr/nr anti dtl.asiux?naram=wC7FVXnwtT)otF2Ae7,IlariPF01_.. 5/15/?n74
Florida Building Code Online
Page 4 of 4
litt-p://www.floridabuildinR.orR/Dr/Draoo dd o(] '. 5/15/2014
UNDERLAYMENT: An underlayment consisting of asphalt saturated felt must be
applied over the entire deck before the installation of TAMKO shingles. Apply the felt
when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the
eaves lapping each course of the felt over the lower course at least 2 in. Where ends join,
lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by
moisture and weathering. Laying of the underlayment and the shingle application must be
done together.
CORPORATE HEADQUARTERS
220 W. FOURTH STREET P.O. BOX 1404 JOPLIN, MO 64802-1404 800-641-4691
tamko.com