HomeMy WebLinkAboutMisc Letters (2) 1
r
SH UTTE R CO n P O n ATI 0 N
8881-B SE ROBWYN ST. HOBE SOUND, FL 33455
PH: (772)-545-3300 FAX: (772)-545.3297
Property Information Building Information
Owner: Roger Wendell Wind Zone: 160 MPH.
Address: 9308 Scarborough Ct Exposure Category: B
Port St.Lucie,FL 34986 Minimum Building Dimension: 35 ft.
Mean Roof Height: 20 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 160 112 7 23.1 -25.4
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code.
Page 1 of 1