HomeMy WebLinkAboutProduct Approval tit.
Agiida Depaftment! BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts i Publications I FBC Staff I BCIS Site Map I Links I Search I
Busines,
ProfessitnalCOUSER:Public User l
Regulation
Product ApDroval Menu>Product or Application Search>Application List>Application History>Application Detail
Application Type Revision tL+.,�
Code Version 2014 qc
Application Status Approved JUN 0 1 2016
Comments PEPIf,9iTTENG
Archived St. Lucie County, NL
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Steve Wadding
Address/Phone/Email 150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
stevew@polyglass.com
Quality Assurance Representative James Akins
Address/Phone/Email 555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800)894-4563
jakins@polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed -
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 06/27/2016
Validated By John W. Knezevich, PE
9 Validation Checklist-Hardcopy Received
Certificate of Independence FLl_654 R16 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D6162 2000
ASTM D6163 2000
ASTM D6164 2005
ASTM D6222 2008
ASTM D6509 2009
FM 4470 1992
FM 4474 2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/17/2015
Date Validated 06/23/2015
Date Pending FBC Approval 06/28/2015
Date Approved 08/18/2015
Summary of Products
FL# Model,Number or Name Description
1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems
Bitumen Roof Systems
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL1654 R16 II 2015 06 FINAL Al ER POLYGLASS MODBIT FL1654-
Approved for use outside HVHZ:Yes R16.Ddf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party:Yes
Other: 1.)The design pressure in this application Evaluation Reports
relates to one particular assembly over concrete FL1654 R16 AE 2015 06 FINAL ER POLYGLASS MODBIT FL1654-
deck. Refer to the ER Appendix for other systems and1R 6.Ddf
deck types. 2.) Refer to ER,Section 5 for other Limits Created by Independent Third Party: Yes
of Use.
Back Next
Contact Us:: 1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please dirk here.
Product Approval Accepts:
securitym Tiug
TRINITY ERD
I.A:PPENDIX 1:ATTACHMENT.REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application Type Description Page
1A-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4
1A-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5
1B Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5
1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6
1D Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6
1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 7-8
1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 8-9
1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 9
2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 10
2B Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 11-12
2C Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 13-14
3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 15-18
3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover 19-20
3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 21
4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 22-23
4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 24
4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 25-27
SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 28
5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 29
5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 30
5D CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 30
5E CWF New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 30
6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 31-32
6B Gypsum New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 33
6C Gypsum New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 33
61) Gypsum New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 33
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 34-36
7B Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 36
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components, Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement:
➢Wood: Minimum 0.75-inch penetration.
➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the CIA
requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover.
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of 36
r)o
sf R1N1- Y J ER®
4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the AHI. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
S. Unless otherwise noted,Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions.
➢ HA(HA): Full coverage at 25-30 lbs/square.
➢ Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.
➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c.
➢ OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is
referenced.
➢ OlyBond Classic(OB Classic): Full coverage at 1 gal/square.
➢3M CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c.
➢Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing.
➢Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
6. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick)
➢OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3)
➢ OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL)
➢ OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II)
➢3M CR-20: MDP -117.5 psf (Min.1.0-inch thick)
7. Bonded polyisocyanu rate insulation boards shall be maximum 4 x 4 ft.
8. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29.
Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements.
9. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted.
10. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
11. For existing substrates in a bonded recover installation,the existing roof system shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of
resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1-52,ANSI/SPRI IA-1 or TAS 124.
12. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application.
13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck
construction and limitations. For systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,
reference is made to FBC Section 1917.4.1,Point 1.
Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report 139290.02.08-1114 for FL1654-1116
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 2 of 36
P-TrIWry ERD
14. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications.
TABLE 1:POLYGLASS ROOF COVERS,
Reference Layer Material Application
BP-AA Base Polyglass G2 Base,FBC Approved ASTM D4601,Type II
HA at 20-40 lbs/square
(Base and Ply sheets,Asphalt-Applied) Ply Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI
SBS-AA
Base or Ply Elastobase,Elastobase Poly,Elastoflex V,Elastoflex S6,Polyglass HT Base 650(SBS,Asphalt-Applied) Cap Elastoflex S6, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G SBS (sand-backed), HA at 20-40 lbs/square
Polyfresko G SBS FR(sand-backed)
Base or Ply Elastoflex V,Elastoflex S6
SBS-TA
(SBS,Torch-Applied) Cap Elastoflex V,Elastoflex S6,Elastoflex S6 G.Elastoflex 56 G FR,Elastoshield TS-G,Elastoshield TS-G FR,Polyfresko G SBS(poly-
Torch-Applied
film backed),Polyfresko G SBS FR(poly-film backed)
SBS-SA Base Elastoflex SA V Base,Elastoflex SA V FR Base,Elastoflex SA V Plus,Elastoflex SA V Plus FR
Self-Adhering
(SBS,Self-Adhering) Cap Elastoflex SA P,Elastoflex SA P FR,Polyreflect
APP-TA Base or Ply Polyglass APP Base,Polyflex,Polybond Torch-Applied
(APP,Torch-Applied) Cap Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR
APP-SA Cap Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool Self-Adhering
(APP,Self-Adhering)
15. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings
associated with coating usage.
➢ PG200 Non Fibered Roof Coating;
➢ PG300 Fibered Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating;
➢ PG650 Fibered Aluminum Roof Coating;
➢ PG700 High Quality Elastomeric Roof Coating;
➢ PG800 Asphalt Emulsion Roof Coating;
➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
➢ Polyplus 65 Premium Fibered Aluminum Roof Coating;
➢ Polybrite 70 Premium Grade Elastomeric Roof Coating;
➢ Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
16. The following represent priming requirements for gypsum-based coverboards:
➢ Dens Deck and Dens Deck Prime shall be field-primed with PG100 prior to self-adhering or torch-applied membrane application. No priming is required for hot-asphalt membrane applications.
➢ SECUROCK Gypsum-Fiber Roof Board does not require field priming for any membrane application.
17. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report 139290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 3 of 36
a�
TRINHYIER®
TABLE 3A-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP
No. (See Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap (psf)
Polyglass G2 Base, Min.0.25-inch Dens Deck,
CertainTeed Glasbase,
32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)FBC Dens Deck Prime,SECUROCK
inch diameter tin lap and 8-inch o.c. Gypsum-Fiber Roof Board, BP-AA (Optional) SBS-AA,
Min.19/32- Firestone MB Base,JM Approved,
W-1 caps with 11 ga. in three,equally HA Min.0.75-inch Fesco Board HA or SBS- BP-AA or SBS-TA, -60.0
inch plywood GlassPermBas or Tamko annular ring spaced,staggered ASTM C1289 (homogeneous)or min.0.5- AA SBS-AA APP-TA
Glass Base or GAFGLAS shank nails center rows polyiso inch Structodek High Density
#75
Fiberboard Roof Insulation
Polyglass G2 Base,
32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)
CertainTeed Glasbase, (Optional)FBC SBS-SA,
,
inch diameter tin lap and 8-inch O.C. Min.0.25-inch Dens Deck, One or
Min.19/32- Firestone MB Base,JM ApprovedAPP-SA,
W-2 caps with 11 ga. in three,equally HA Dens Deck Prime,SECUROCK HA SBS-SA more 585- -60.0
inch plywood Perma-Ply 28,Tamko ASTM C1289 SBS-TA,
Glass Base or GAFGLAS annular ring spaced,staggered polyiso Gypsum-Fiber Roof Board SA,SBS-TA, APP-TA
#75 shank nails center rows APP-TA
Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c.in 4-inch
CertainTeed Glasbase, (Optional)FBC (Optional)
inch diameter tin lap and 8-inch o.c. Min.0.25-inch Dens Deck,
Min.19/32- Firestone MB Base,JM Approved, Polyflex One or
W-3 inch plywood Perma-Ply 28,Tamko caps with 11 ga. In three,equally ASTM C1289 HA Dens Deck Prime, CK HA SA Base more APP- APP-TA 60.0
Glass Base or GAFGLAS annular ring spaced,staggered polyiso Gypsum-Fiber Rooff Board
oard TA
#75 shank nails center rows
32 ga.,1-5/8- 6-inch o.c.In 4-Inch Min.2-inch D-IS,08500,
ACFoam II,Ill, CR-20 or M- Min.0.25-inch Dens Deck, D-IS,
inch diameter tin lap and 6-inch o.c. BP-AA (Optional) SBS-AA,
W-4 caps with 12 ga. in four,equally or SBS- BP-AA or SBS-TA, -60.0
Min.19/32- Elastobase or H-Shield,H- OSFA,atop Dens Deck Prime or OB500, *
inch plywood Elastobase Poly Shield CG, fastener SECUROCK Gypsum-Fiber CR-20 or
annular ring spaced,staggered AA SBS-AA APP-TA
shank nails center rows Multi-Max FA3 rows,7-inch Roof Board M-OSFA
or ENRGY-3 O.C.
08500
2-inch D-IS, ,
32 ga.,1-5/8- 6-inch o.c,in 4-inch Min. (Optional)
One or c
inch diameter tin lap and 6-Inch o. . ACFoam II,III, CR-20 or M- D-IS, SBS-SA,
Min.19/32- Elastobase or H-Shleld,H- OSFA,atop (Optional)Additional layers OB500, APP-SA,
W-5 caps with 12 ga. In four,equally SBS-SA more SBS- -60.0*
inch plywood Elastobase Poly Shield CG, fastener of base insulation CR-20 or SBS-TA,
annular ring spaced,staggered Multi-Max FA3 rows,7-inch M-OSFA SA,SBS-TA, App-TA
shank nails center rows APP-TA
or ENRGY-3 O.C.
32 ga.,1-5/8- 6-Inch o.c.in 4-inch Min.2-inch D-IS,OB500,
inch diameter tin lap and 6-inch o.c. ACFoam Il,III, CR-20 or M- D-IS, (Optional)
W-6
Min. caps with 12 ga. in four,equally APP-TA -60.0 19/32- Elastobase or H-Shield,H- OSFA,atop (Optional)Additional layers OBSOO, Polyflex One or *
inch plywood Elastobase Poly Shield CG, fastener of base insulation CR-20 or SA Base more APP-
shankannular nailsrincenter rows spaced,staggered Multi-Max FA3 rows,7-inch M-OSFA TA
shank nails
or ENRGY-3 O.C.
Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-1114 for F1.1654-1116
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 36
TRINIh(j ERD
TABLE IA-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover
Type MDP(psf)
No.
(See Note i) T e Fasten Attach Type Attach Type Attach Base Ply Cap
12-inch o.c.in 4- Min.0.25-inch Dens Deck,Dens
inch lap and 12- (Optional)FBC Deck Prime,SECUROCK Gypsum-
Min19/32- Elastobase or inch o.c.in two, Approved,ASTM BP-AA or OMG Flat Bottom Fiber Roof Board,Min.0.75-inch (Optional) SBS-AA,
W-7 Plates(square) staggered center olyisolyis type 11o-cyanurate SBS AA HA Fesco Board(homogeneous)or HA BP-AA or SBS-TA, -60.0
inch.plywood Elastobase Poly with Roofgrip#12 equally spaced, pmin.0.5-inch Structodek High SBS-AA APP-TA
Density Fiberboard Roof
rows
Insulation
12-inch o.c.in 4- (Optional)
inch lap and 12- (Optional)FBC SBS-SA,
OMG Flat Bottom Min.0.25-inch Dens Deck,Dens One or
Min.19/32- Elastobase or inch o.c.in two, Approved,ASTM APP-SA,
W-8 Plates(square) olyiso-cyan11 SBS-TA,HA Deck Prime,SECUROCK Gypsum- HA SBS-SA more SBS- -60.0
inch plywood Elastobase Poly with Roofgrip#12 equally spaced, ptype urate Fiber Roof Board SA,SBS-TA,
staggered center olyisAPP-TA
APP-TA .
rows
12-inch o.c.in 4-
inch lap and 12- (Optional)FBC (Optional)
OMG Flat Bottom Min.0.25-inch Dens Deck,Dens
Min.19/32- Elastobase or inch o.c.in two, Approved,ASTM Polyflex SA One or
W-9 Plates(square) HA Deck Prime,SECUROCK Gypsum- HA APP-TA 60.0
inch plywood Elastobase Poly with Roofgrip#12 equally spaced, C1289,type II Fiber Roof Board Base more APP-
staggered center polyiso-cyanurate TA
rows
TABLE IB:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER
System Deck(See Base Insulation Layer Top Insulation Layer Roof Cover
MDP(psf)
No. Note 1) Type Fasten Attach Type Attach Base Ply Cap
Dekfast Hex with Dekfast Min.0.75-inch Fesco Board (Optional if (Optional if using AA
Min.1.5-inch ENRGY SBS-AA,
W-10 Min.19/32- 3,H-Shield or #12 or Trufast 3"Metal 1 per 1.33 ftz (homogeneous)or min.0.5-inch HA using AA Ply) Base)One or more BP- SBS-TA, -60.0
Inch plywood Insulation Plate with Structodek High Density Fiberboard BP-AA,SBS- AA,SBS-AA,SBS-TA or
Polytherm APP-TA
Trufast DP Roof Insulation AA APP-TA
Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report 139290.02.08-1114 for F1.1654-1116
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 5 of 36
(_�o
TRIIOIII`Y�ER®
TABLE 1C:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
System Deck(See Top Insulation Layer Roof Cover
Base Insulation Layer MDP(psf)
No. Note 1) Type Fasten Attach Base Ply Cap
Min.0.5-inch Structodek High Density
Min.19/32- (Optional)One more Fiberboard Roof Insulation or min.0.25- Dekfast Galvalume Steel Hex 1 per (Optional using (Optional if using AA Base) SBS-AA,SBS-TA,
W-11 layers,any combination, z AA Ply)BP-AA,SBS- One or more BP-AA,SBS- -82.5
inch plywood loose laid inch Dens Deck,Dens Deck Prime or with Dekfast#12 DP 1.33 ft AA AA,SBS-TA or APP-TA APP-TA
SECUROCK Gypsum-Fiber Roof Board
(Optional)One or more Dekfast Galvalume Steel Hex
Min.19/32- Min.1.5-inch ENRGY 3,H-Shield or with Dekfast#12 DP or 1 per (Optional)One or more SBS-SA,APP-SA,
W-12 inch plywood layers,any combination, Polytherm Trufast 3"Metal Insulation 1.33 ftz SBS-SA SBS-SA,SBS-TA,APP-TA SBS-TA,APP-TA 82.5
loose laid Plate with Trufast DP
(Optional)One or more Dekfast Galvalume Steel Hex
W-13 Min.19/32- layers,any combination, Min.1.5-inch ENRGY 3,H-Shield or with Dekfast#12 DP or 1 per Polyflex SA Base (Optional)One or more APP-TA 82.5
inch plywood loose laid Polytherm Trufast 3"Metal Insulation 1.33 ft APP-TA
Plate with Trufast DP
TABLE 11):WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE D:PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER
System Deck(See Insulation Layer(s) Base Sheet Roof Cover
MDP(psf)
No. Note 1) Type Attach Base Fasten Attach Ply Cap
Elastobase,Elastobase Poly,Polyglass OMG Flat Bottom Plates(square)
One or more 12-Inch o.c.in 4-inch lap and 12- (Optional)One or SBS-AA,
Min.19/32- Prelim. G2 Base,CertainTeed Glasbase, with Roofgrip#14,Dekfast Hex with
W-14 layers,any inch o.c.in two,equally spaced, more BP-AA,SBS-AA, SBS-TA, -52.5
inch plywood combination Attached Firestone MB Base,JM Perma-Ply 28, Dekfast#14 or Trufast 3"Metal staggered center rows SBS-TA or APP-TA APP-TA
Tamko Glass Base or GAFGLAS#75 Insulation Plate with Trufast HD
One or more Dekfast Hex with Dekfast#14 or 12-inch o.c,in 4-inch lap and 12- SBS-SA,
Min.19/32- Prelim. Elastobase or Elastobase Poly with APP-SA, *
W-15 layers,any Trufast 3"Metal Insulation Plate inch o.c.in two,equally spaced, One or more SBS-SA -52.5
inch plywood combination Attached poly top surface with Trufast HD staggered center rows SBS-TA or
APP-TA
Min.19/32-
One or more Prelim. Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or 12-inch o.c.in 4-inch lap and 12-
W-16 layers,any Trufast 3"Metal Insulation Plate inch o.c.in two,equally spaced, Polyflex SA Base APP-TA -52.5*
Inch plywood combination Attached poly top surface with Trufast HD staggered center rows
Min.19/32-
One or more Prelim. OMG Flat Bottom Plates(square) 12-inch o.c.in 4-Inch lap and 12- (Optional)One or SBS-AA,
W-17 inch plywood layers,any Attached Elastobase or Elastobase Poly with Roofgrip#12 inch o.c.in two,equally spaced, more BP-AA,SBS-AA, SBS-TA, -60.0
combination staggered center rows SBS-TA or APP-TA APP-TA
One or more 12-inch o.c.in 4-Inch lap and 12- SBS-SA,
Min.19/32- Prelim. Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square) APP-SA,
W-18 inch plywood layersany Attached poly top surface with Roofgrip#12 inch o.c.in two,equally spaced, One or more SBS-SA SBS-TA or 60.0*
combination staggered center rows APP-TA
FOne or more 12-inch o.c.in 4-inch lap and 12-
Min.19/32- Prelim. Elastobase or Elastobase Poly with OMG flat Bottom Plates(square)
W-19 inch plywood layers,any Attached poly top surface with Roofgrip#12 inch o.c.in two,equally spaced, Polyflex SA Base APP-TA
combination staggered center rows
Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report P9290.02.08-1114 for F11654-1116
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 6 of 36
TRINITY l ERD
TABLE 1E-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE E:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAas),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover
MDP(psf)
No. Note 1) Base Fasten Attach Ply Cap
Min.15/32- 9-inch o.c.at 2-inch lap and 18-inch o.c.in (Optional)SP-AA,SBS-AA, SBS-AA,SBS-TA -45.0*
W-20 inch plywood Elastobase Simplex MARX Cap two,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
Min.15/32- 9-inch o.c,at 2-inch lap and 12-inch o.c,in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -52.5
W-21 Inch plywood Elastobase Simplex MAXX Cap two,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
Original Simplex Cap Nails(1-inch metol head
Min.15/32- 6-inch o.c.at 3-Inch lap and 6-inch o.c,in four, SBS-SA,APP-SA
W-22 inch plywood Polyglass APP Base diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows (Optional)SBS-SA or APP-TA or APP-TA -52.5
grooved shank)
Min.15/32- Original Simplex Cap Nails(1-inch metal head 6-inch o.c.at 3-Inch lap and 6-inch o.c.in four,
W-23 inch plywood Polyglass APP Base diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows Polyflex SA Base APP-TA -52.5
grooved shank)
Original Simplex Cap Nails(1-inch metal head SBS-SA,APP-SA,
Min.15/32- 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, (Optional)SBS-SA,SBS-TA or
W-24 inch plywood Elastobase(with poly top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows APP-TA SBS-TA or APP- -52.5
grooved shank) TA
Original Simplex Cap Nails(1-inch metal head
Min.15/32- 6-inch o.c.at 3-inch lap and 6-inch o.c.in four,
W-25 inch plywood Elastobase(with poly top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows Polyflex SA Base APP-TA -52.5
grooved shank)
Original Simplex Cap Nails(1-inch metal head
MIA.15/32- 6-inch o.c.at 3-Inch lap and 6-Inch o.c.In four, (Optional)BP-AA,SBS-AA, SBS-AA,5B5-TA _52.5
W-26 Inch plywood Elastobase(with sand top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
grooved shank)
Elastobase,Elastobase Poly,
Polyglass G2 Base,CertainTeed (Optional)One or more BP-
MIn.19/32- 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c,in 4-Inch lap and 8-inch o.c.In SBS-AA,SBS-TA,
W-27 inch plywood Glasbase,Firestone MB Base,JM annular ring shank nails three,equally spaced,staggered center rows AA,SBS-AA,SBS-TA or APP- APP TA -60.0
Perma-Ply 28,Tamko Glass Base TA
or GAFGLAS#75
W 28 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c.In 4-Inch lap and 8-Inch o.c.in (Optional)One or more 585- SBS-SA,APP-SA,
SBS-TA or APP- -60.0
inch plywood poly top surface annular ring shank nails three,equally spaced,staggered center rows SA,SBS-TA or APP-TA TA
W-29 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c.in 4-Inch lap and 8-inch o.c.In Polyflex SA Base APP-TA -60.0
inch plywood poly top surface annular ring shank nails three,equally spaced,staggered center rows
Min.15/32- 6-inch o.c.at 2-inch lap and 6-inch o.c.in two, (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -90.0
W-30 Inch plywood Elastobase Simplex MARX Cap equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
Min,19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c.in 4-Inch lap and 4-inch o.c.in four, (Optional)One or more SBS- SBS-SA,APP-SA,
W-31 inch plywood poly top surface annular ring shank nails. equally spaced,staggered center rows SA,SBS-TA or APP-TA SBS-TA or APP- -97.5
TA
Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-Inch diameter tin caps with 11 ga. 4-inch o.c.in 4-Inch lap and 4-inch o.c.In four,
W-32 Inch plywood poly top surface annular ring shank nails. equally spaced,staggered center rows Polyflex SA Base APP-TA 97.5
Exterior Research and Design,LLC.d/b/a Trinity l ERD Evaluation Report P9290.02.08-R14 for F1.1654-1116
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 7 of 36
\\JTRINrry I ERD
TABLE 1E-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover
MDP(psf)
No. Note 1) Base Fasten Attach Ply Cap
Min.15/32- 6-inch o.c.at 2-inch lap and 6-inch o.c,in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA
W-33 inch plywood Elastobase Simplex MAXX Cap three,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA -105.0
W-34 Min.19/32- Elastobase or Elastobase Poly 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c.in 4-inch lap and 6-inch o.c.in four, � SBS-AA(Optional)One or more BP-
SBS-TA or APP- SBS-AA,SBS-TA, -112.5
inch plywood annular ring shank nails equally spaced,staggered center rows TA , APP-TA
32 ga.,1-5/8-inch diameter tin caps with 11 ga. (Optional)Elastoflex SA V SBS-SA,APP-SA,
W-35 Min.19/32- Elastobase or Elastobase Poly with annular ring shank nails. Note:Tin caps are to be equally
o.c.in 4-inch lap and 6-ter r o s In four, Plus,Elastoflex SA V Plus FR, SBS-TA or APP- -112.5
inch plywood poly top surface primed with PG100 or ASTM D41 primer. equally spaced,staggered center rows SBS-TA or APP-TA TA
Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c.in 4-inch lap and 6-inch o.c.in four,
W-36 annular ring shank nails. Note:Tin caps are to be Polyflex SA Base APP-TA -112.5
inch plywood poly top surface primed with PG100 or ASTM D41 primer. equally spaced,staggered center rows
TABLE 1E-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)ORRECOVER
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover
MDP(psf)
No. Note 1) Base Fasten Attach Ply Cap
Elastobase,Elastobase Poly,
Polyglass G2 Base,CertainTeed OMG Flat Bottom Plates(square)with Roofgrip (Optional)One or more BP-
W 37 Min.plywood
Glasbase,Firestone MB Base,JM #14,Dekfast Hex with Dekfast#14 or Trufast 3" 12-inch all in 4-inch lap and 12-inch r rows
i s AA SBS-AA,SBS-TA or APP- SBS-AA,SBS-TA, -52.5
inch plywood Perma-Ply 28,Tamko Glass Base Metal Insulation Plate with Trufast HD two,equally spaced,staggered center rows TA APP-TA
or GAFGLAS#75
Min.19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.in 4-inch lap and 12-inch o.c.in SBS-SA,APP-SA,
W-38 inch plywood poly top surface Insulation Plate with Trufast HD two,equally spaced,staggered center rows One or more SBS-SA SBS-TA or APP- -52.5
TA
W-39 Min.19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.in 4-inch lap and 12-inch o.c.in Polyflex SA Base APP-TA -52.5*
inch plywood poly top surface Insulation Plate with Trufast HD two,equally spaced,staggered center rows
W-40 Min.19/32- Elastobase or Elastobase Poly OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c,in AA SBS-AA(Optional)One or more BP-
SBS-TA or APP- SBS-AA,SBS-TA, _60.0
inch plywood #12 two,equally spaced,staggered center rows TA , APP-TA
W-41 One 19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in SBS-SA,APP-SA,
One or more SBS-SA SBS-TA or APP- -60.0*
inch plywood poly top surface #12 two,equally spaced,staggered center rows TA
W-42 Min.19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in Polyflex SA Base APP-TA
inch plywood poly top surface #12 two,equally spaced,staggered center rows
Exterior Research and Design,I.I.C.d/b/a Trinity(ERD Evaluation Report 139290.02.08-1114 for F1.1654-1116
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 8 of 36
ERD
TRINITY'
TABLE 1E-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)oRRECOVER
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREws&PLATES),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover MDP(psf)
No. Note 1) Base Fasten Attach Ply Cap
OMG#12 Standard Roofgrip or OMG#14 Heavy
Min.15/32- 6-inch o.c.at 4-Inch lap and 6-inch o.c.in
W-43 inch plywood Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round three,equally spaced,staggered center rows (Optional)APP-TA APP-TA -90.0
Metal Plates or OMG Flat Bottom Metal Plates
OMG#12 Standard Roofgrip or OMG#14 Heavy
Min.15/32- 6-inch o.c.at 4-inch lap and 6-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA
W-44 inch plywood Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round three,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA -90.0
Metal Plates or OMG Flat Bottom Metal Plates
W-45 Min.15/32- Elastobase(with sand top surface) Trufast#12 DP or Trufast#14 HD(min.1-5/8-Inch 6-inch o.c,at 4-inch lap and 6-inch o.c.in (Optional)BP-AA or SBS-AA SBS-AA -90.0
inch plywood long)with Trufast 3"Metal Insulation Plates three,equally spaced,staggered center rows
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-Inch o.c.at 4-inch lap and 6-inch o.c.in five,
W-46 inch plywood Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round equally spaced,staggered center rows (Optional)APP-TA APP-TA -120.0
Metal Plates or OMG Flat Bottom Metal Plates
OMG#12 Standard Roofgrip or OMG#14 Heavy
Min.15/32- 6-inch o.c.at 4-inch lap and 6-inch o.c.in five, (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA
W-47 Inch plywood Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA -120.0
Metal Plates or OMG Flat Bottom Metal Plates
W-48 Min.15/32- Elastobase(with sand top surface) Trufast#12 DP orTrufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.c.in five, (Optional)BP-AA or SBS-AA SBS-AA 120.0
inch plywood long)with Trufast 3"Metal Insulation Plates equally spaced,staggered center rows
TABLE IF:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER
System Deck(See Primer Roof Cover MDP(psf)
No. Note 1) Joint Treatment Base Ply Cap
Min.15/32- (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W 49 inch plywood PG100 None SBS-SA 90.0
p ywood TA,APP-TA TA,APP-TA
Min.15/32- (Optional)One or more
W-50 inch plywood (Optional)PG100 None Polyflex SA Base APP-TA APP-TA 90.0
Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W-51 inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA 97'5
Min,15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W-52 inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SAV Plus FR TA,APP-TA TA,APP-TA 135.0
Min.15/32- Plywood:jbints are covered with-4 mch wide strips of Elastoflex SAV Plus;-rolled mtci (Optional)One or more
N/-53 (Optional)PG100 Polyflex SA Base_ APP-TA 135.0
inch plywood placeao_create,contnuous borid:, ___-.- e ._: APP-TA
Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 9 of 36