FL# FL1956-1112
v
Application Type Editorial Change
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and
ratified by the POC and/or the Commission if necessary.
Comments
Archived ❑
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency UL LLC
Validated By RobertJ. M.Nieminen,PE
® Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 09/17/2015
https:// .floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6... 6/2/2016
Florida Building Code Online Page 2 of 4
Date Validated 10/06/2015
Date Pending FBC Approval
Date Approved 10/09/2015
I
Summa of Products
FL# Model,Number Description
or Name
I
1956.1 Elite Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.1)df
HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ: Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure: N/A FL1956 R12 II Glass Seal Elite Glass Seal app inst.pdf
Other:Asphalt shingles Verified By: Robert Nieminen 59166
shall be used only on roof Created by Independent Third Party: No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.2 1 Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.od f
HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure: N/A FL1956 R12 II Glass Seal Elite Glass Seal apo inst.odf
Other:Asphalt shingles Verified By: Robert Nieminen PE 59166
shall be used only on roof Created by Independent Third Party: No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.3 Heritage A dimensional asphalt sh ingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.pd f
HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure: N/A FL1956 R12 II Heritage D F J P apo inst.pdf
Other:Asphalt shingles FL1956 R12 II Heritage F apo inst.pdf
shall be used only on roof FL1956 R12 II Heritage T apo inst.pdf
slopes of 2:12 or greater. Verified By: Robert]. M. Nieminen FL 59166
Nails must be used as the Created by Independent Third Party: No
method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.4 1 Heritage 30 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use In FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.pdf
HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.odf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure: N/A FL1956 R12 II heritage 30 app Inst aoril 10.odf
Other:Asphalt shingles FL1956 R12 II heritage 30 app inst f april 10.1)df
shall be used only on roof Verified By: Robert Nieminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party: No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
1956.5 I Heritage 50 A dimensional asphalt sh ingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.odf
HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.odf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ: Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II heritage 50 aop inst anril 10.)d
Other:Asphalt shingles FL1956 R12 II heritage 50 app inst f april 10.pdf
shall be used only on roof Verified By: Robert Nieminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party: No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
https:HYv .floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6... 6/2/2016
Florida Building Code Online Page 3 of 4
1956.6 Heritage Premium A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.odf
HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II Heritage Premium D P apo inst.pdf
Other:Asphalt shingles FL1956 R12 II Heritage Premium F app inst.pdf
shall be used only on roof FL1956 R12 II H eritaoe Premium T app inst.odf
slopes of 2:12 or greater. Verified By: Robert Nieminen 59166
Nails must be used as the Created by Independent Third Party: No
method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.7 Heritage Vintage A heavy weight dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.pdf
HVHZ: No FL1956 R12 C CAC UL shingle matrix.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ: Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II Heritage Vintage apo inst.pdf
Other:Asphalt shingles Verified By: Robert J. M. Nieminen PE 59166
shall be used only on roof Created by Independent Third Party: No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.8 Heritage Vintage Hip and ridge shingles
12 X 12 Hip and
Ridge
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.1)d f
HVHZ: No FL1956 R12 C CAC UL shingle matrix.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II TAMKOn H eritageCp) 12 x 12 Hip and Ridge Application Instructions.odf
Other:Asphalt shingles Verified By: Robert]. M. Nieminen PE 59166
shall be used only on roof Created by Independent Third Party: No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.9 Heritage A dimensional asphalt shingle.
Woodgate
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.pdf
HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.1)df
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ: Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II H eritaoe Woodoate D app inst.odf
Other:Asphalt shingles FL1956 R12 II Heritage Woodgate F apo inst.ndf
shall be used only on roof Verified By: Robert Nieminen 59166
slopes of 2:12 or greater. Created by Independent Third Party: No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
1956.10 1 Heritage XL A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.pd f
HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II heritage x I ago inst d aoril Modf
Other:Asphalt shingles FL1956 R12 II heritage x I ago inst f april 10.1)df
shall be used only on roof Verified By: Robert Nieminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party: No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
1956.11 Hip and Ridge Hip and ridge shingles
Shingles
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tam ko Sery Conf FL 1956 2015.pd f
HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf
https:HNvww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6... 6/2/2016
Florida Building Code Online Page 4 of 4
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ: Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II 12.25x1 2 Hip and Ridge.pdf
Other: Hip and Ridge FL1956 R12 II 12 x 12 Hip Ridge Application Instructions.pdf
shingles shall be used only FL1956 R12 II 12-1-4x 12 HipRidge Sealant Dab Illustrations.odf
on roof slopes of 2:12 or FL1956 R12 II 12x12 Hip Ridge Sealant Dab Illustrations.odf
greater. Nails must be used Verified By: Robert Nieminen 59166
as the method of Created by Independent Third Party: No
attachment. Evaluation Reports
Created by Independent Third Party:
Back Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone;850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement;:Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please click here
Product Approval Accepts:
s MtF
sccudtvmj,.v cs-
https://wlww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6... 6/2/2016
i
UL
September 17,2015
Tamo Building Products
i
220� 4th Street
PO Box 1404
Jopl , MO 64801
Contact Name: Kerri Eden
Email Address: Kerri Eden _tamko.com
Subject: UL Third Party Inspection Service for Florida Quality Assurance
Expiration Date: September 17, 2018
Reference: UL Order 10966260
Dear Ms. Eden:
This letter is to confirm that Tamko Building Products has an agreement with UL LLC to conduct
audits at your plant to verify Florida Quality Control requirements at the following locations:
Tamko Building Products Tamko Building Products Tamko Building Products
601 N. High St 1598 Hwy 183 2300 35h St
Joplin MO 64801 Phillipsburg KS 67661 Tuscaloosa AL 35401
Tamko Building Products Tamko Building Products
7910 S Central Expy 4500 Tamko Dr
Dal as TX 75216 Frederick MD 21704
Quality Control System and Products will be inspected according to Florida Product Approval Report
F0956 to ensure the manufacturer's quality documentation is well defined,fully documented and
effectively implemented.
A minimum of two(2)inspections per year will be conducted. This service has been established
under file R2919.
U L LLC
333 ffingsten Road,Northbrook,IL 60062-2096 USA
T:8 7.272.8800/F:847.272.8129/W:UL.com
If you have any questions,please call me at 847-664-3623.
Kind regards,
LeAnna Gradecki
Project Coordinator
Product Safety
Tel:847-6643623
Fax 847-513-7853
LeAn na.Gradecki(cD u I.com
I
UL LI LC
333 Pfingsten Road Northbrook,
IL 60062-2096 USA M:
847664-3623
LeAnna.Gradecld@ul.com
I
Application Instructions for
TAMKO HRR1TAGEO 30
BUILDING PRODUCTS LAMINATED ASPHALT SBINCLBS
Dallas,TX•Tuscaloosa,AL• Phillipsburg, KS • Joplin, MO
i
I
THESE ARE THE MANUFACTURER'S.APPLICATION'INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS MOTHER ROOFING DEFECTS RESULTING
FROM'FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN CO WEATHER(BELOWA0°F),CARE MUST BETAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
IMPORJAN T:It is not necessary to remove the plastic strip from the back of the shingles.
L ROOF DECK &FASTENERS
These shingles are for application to roof decks capable of receiving WIND CAUTION: Extreme wind velocities can damage these
and retaining fasteners,and to inclines of not less than 2 in.perfoot. shingles after application when proper sealing of the shingles
For roofs having pitches 2 in.per foot to less than 4 in.perfoot,refer does not occur.This can especially be a problem if the shingles
to special instructions titled"LowSlope Application",Shingles must are applied in cooler months or in areas on the roof that do not
be applied properly,TAMKO assumes no responsibility for leaks Or receive direct sunlight.These conditions may impede the sealing
defects resulting from improper application,or failure to properly of the adhesive strips on the shingles.The inability to seal down
prepare the surface to be roofed over. may be compounded by prolonged cold weather conditions and/
NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, or blowing dust.In these situations,hand sealing of the shingles is
dry anc!free from warped surfaces.It is recommended that metal recommended.To insure immediate sealing,apply 4 quarter-sized
drip edges be installed at eaves and rakes. dabs of TAM-PRO®Premium SBS Adhesive or TAMKO Tam-Seal
Adhesive on.the back of the shingle 1 in.(25mm)and 13 in.(330nim)
PLYWOOD:All plywood shall be exterior grade as defined by the in from each side and 1 in. (25mm) up from the bottom of the
Engineered Wood Association.Plywood shall be a minimum of 3/8 shingle.Press shingle firmly into the adhesive.For maximum wind
in.thickness and applied in accordance with the recommendations resistance along rakes,cement shingles to the underlayment and
of the iEngineered Wood Association. each other in a 4 in.(102mm)width of TAM-PRO SBS Adhesive or
SHEATHING BOARDS: Boards shall be well-seasoned tongue= TAMKO Tam-Seal Adhesive. Caution:Apply ONLY a thin uniform
and-groove boards and not over 6 in.nominal width.Boards shall layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts
be a 1 in. nominal minimum thickness. Boards shall be property can cause blistering of the shingles and may soften the asphalt_in
spat i and nailed. certain.underlayments resulting in-the asphaltflowing,dripping and
staining.Shingles must also be fastened according to the fastening
a.VENTILATION instructions described below.
Inadequate ventilation of attic spaces can cause accumulation of Correct placement of the fasteners is critical to the performance
moisture in winter months and a build up of heat in the.summer.
of the shingle. If the fasteners are not placed as shown in the
These conditions can lead to: diagram and described below,this will result.in the termination of
TAMKO's liabilities under the limited warranty.TAMKO will not be
1.Vapor Condensation responsible for damage to shingles caused by winds in excess of
2.Buckling of shingles due to deck movement. the applicable mph as stated in the limited warranty.See limited
3.Rotting of wood:members. warranty for details.
FASTENING PATTERNS Fasteners must be placed 6-1/8 in.from
4.Premature failure of roof. the bottom edge of the shingle, penetrating through the common
To insure adequate ventilation and circulation of air,place louvers bond,and located horizontally as follows:
of sufficient size high in the gable ends and/or install continuous 1)Standard Fastening Pattern.(For use on decks with slopes 2 in.
ridge and soffit vents. FHA_minimum property standards require per foot to 21 in.per foot.)One fastener 1 in.back from each end
one square foot of net free ventilation area to each 150 square feet and one 13-1/2 in.back.from each end of the shingle for a total of 4
of space to be vented,or one square foot per 300 square feet if a fasteners.(See standard fastening pattern illustrated below).
vapor,barrier is installed on the warm side of the ceiling or if at least.
one half of the ventilation is provided near the ridge.If the ventilation STANDARD FASTENING PATTERN
opern 1gs are screened,the total area should be doubled. FASTENERS NAIL ZONE
COMMON
IF— IBOND
IS PARTICULARLY IMPORTANT TO PROVIDE
ADEQUATE VENTILATION. 6-1/a" EXPOS URE S 5fa"
1-►I Ir-12-1/2"-►-12-3/8"-+-- 12-1/2" �-1"
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09
Visit Our Web Site:at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
a1f11koxoR'1 Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868
i
® (CONTINUED from page 1)
TAMKO HERITAW 30
BUILDING.PRODUCTS LAMINATED ASPHA6T SHINGLES
Dallas, TX•Tuscaloosa, AL• Phillipsburg, KS • Joplin, MO
2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for
greater than 21 in.per foot.)One fastener 1 in.back.from each end reroofing thus allowing a minimum deck penetration of 3/4 in.The
and one fastener 8-1/2 in.back from each end and.onefastener'16 crown of the staple must be parallel to the length of the shingle.
in.back:from each end.for a total of 6 fasteners per shingle.(See The staple crown.should be driven flush with the shingle surface.
Mansard and High Wind Fastening Pattern illustrated below.) Staples that are crooked,underdriven or overdriven are considered
MANSARD AND HIGH WIND FASTENING PATTERN improperly applied.
FASTENERS NAILZONE Property Driven Improperly Driven
COMMON underddven overdriven croaked
BOND SIGN
Asphalt
IShingles
6-1)8EXPOSURE 5 5 8° Deddin
E� 9
i� �-7-12'+►�7-1/Y-�-738°-►h-7-12" -7-12°-►I I.—i° -�'"n"''
3) High Wind Fastening Pattern. (For High Wind Application CAUTION:ALL FASTENERS MUST BE DRIVEN INTO THE NAIL
requirements)One fastener 1 in.back from each end.One fastener ZONE/COMMON BOND AS SHOWN 1N THE DIAGRAM ABOVE.
&1/2 in'.back from each end and one fastener 16 in:back from each
end for total of six(6)fasteners per shingle.In addition to this shingle 4.QNDlENLAYMENT
fastening patter requirement for High Wind Application,TAMKO UNDERLAYMENT An underlayment consisting of asphalt saturated
also rewires the use of the following TAMKO products:TAMKO felt must be.applied over the entire deck before the installation of
felts ori underlayments;TAMKO Moisture Guard Plus underlayment TAMKO shingles.Failure to add underlayment can cause premature
at all eaves,rakes,and valleys;TAMKO or TAM-PRO cements and failure of the shingles which is not covered by TAMKO's limited
coatings products where required;TAMKO ventilation.where required, warranty.Apply the felt When the deck is dry.On roof decks 4 in.
TAMKO starter shingles if available in area,and TAMKO Hip and Ridge per foot and greater apply thefelt parallel to the.eaves lapping each
shingles installed on all hips and ridges.Along.rakes,cementshingles course of the felt over the lower course at.least 2 in.Where ends
to the 6nderlayment and each other in a 4 in.(102 mm)width of TAM- join, lap the felt 4 in. If left exposed,the underlayment felt may
PRO SBS Adhesive or TAMKO Tam-Seal Adhesive.Also,see local be adversely affected by moisture and weathering. Laying of the
building codes for proper nailing application.High Wind Application underlayment and the shingle application must be done together.
is offered on new construction or complete tear-off applications only. Products which are acceptable for use as underlayment.are:
It is not offered for recover applications. If.High Wind Application
requirements are not followed,the High Wind Application Warranty - TAMKO No.15 Asphalt Saturated Organic Felt
MPH, as stated on Table I in the Limited Warranty,reverts to the - A non-perforated asphalt saturated organic felt which meets
Standard Application Wind Warranty MPH limit.(See Mansard and ASTM:D226,Type I or ASTM D4869,Type I
High Wind Fastening Patter illustrated above.) - Any TAMKO non-perforated asphalt saturated organic felt
- TAMKO TW Metal and.Tile Underlayment,TW Underlayment
NAILS:TAMKO recommends the use of nails as the preferred method and Moisture Guard PlusO (additional ventilation may be
of.application. Standard type roofing nails should be.used. Nail required.Contact TAMKO's Technical Services Department
shanks should be made of minimum 12 gauge wire,and a minimum for more information.)
head diameter of 3/8 in.Nails should be long enough to penetrate
3/4 in.linto the roof deck.Where the deck is less than 3/4 in.thick, In areas where ice builds up along the eaves or a back-up of water
the nails should be long enough to penetrate completely through from frozen or clogged gutters is a potential problem,TAMKO's
plywood decking and extend at least 1/8 in.through the roof deck. Moisture Guard Plus®waterproofing underlayment(or any specialty
Drive nail head flush with the shingle surface. eaves flashing product) may be applied to eaves, rakes, ridges,
valleys, around chimneys, "Skylights or dormers to help prevent
Properly A`'"`" 1IIpt0�"ro`ia water damage. Contact TAMKO's Technical Services Department
3B•rnln Cianetei_ imderdriven overdriven crooked for more information.
Asphott
_ shingles TAMKO does not recommend the use of any substitute products
5 r
Ei1Mocking as shingle underlayment.
6ffm
� � �Vd•nominal
6�!IgM snmpeae*. n Iradeqaale roodeep wi, inadequate S.APPWCATION INSTRUCTIONS.
end flush w,ith:shinglesuAaze penetration Into shingle anchorage STARTER COURSE:A starter course may consist of TAMKO Shingle
Starter,self-sealing 3-tab shingles or a 9 inch wide strip of mineral
STAPLES: If staples are used in the attaching process,follow the surface roll roofing.If self-sealing 3-tab shingles are used,remove
above instructions for placement.All staples must be driven with the exposed tab portion and install with the-factory applied adhesive
pneumatic staplers.The staple must meet the following minimum adjacent to the eaves. Attach the starter course with approved
dime�slonal requirements.Staples.must be made from a minimum fasteners along a line parallel to and 3 in.to 4 in.above the eaves
1'6 gauge galvanized wire.Crown width must be at least 15/16 in. edge.The starter course should overhang both the eaves and rake
(staple crown width is measured outside the legs).Leg length should edges 1/4 in.to 318 in.
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
amkoxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868
q r ;= �. s
® (CONTINUED from page 2)
MTAMKO HERITAGE® 30
BUILDING PROD®CTS 1rrAMINATED.ASPHALT SHINGLES
Dallas, TX•Tuscaloosa, AL• Phillipsburg, KS - Joplin, MO
SHINGLE APPLICATION:Start thefirst course with a full size shingle S.LOW SLOPE APPLICATION
and overhang the rake edge 1/4 in.Cut 10-3/8 in.from a full shingle On pitches 2 in,per foot to 4 in.per foot cover the deck with two layers
to forma shingle 29 in.long.Use this to start the second-course(see of asphalt saturated felt.Begin-by applying
the felt in a 19 in..wide strip
diagram below):Out a23 in.long shingle to start:the third course.Use along the eaves and overhanging the drip edge by 1/4 to 3/4 in.Place
the remaining 16-3/8 in.piece of shingle to startthe fourth course and a full 36 in.wide sheetover'the 19 in.wide starter piece,completely
use the remaining 10-3/8 in.piece to begin the fifth course.Continue overlapping it.All succeeding courses will be positioned to overlap the
up the�ake'in as many rows as necessary using the same formula preceding course by 19 In.If winter temperatures average 25'F or less,
as outlined above.The butt of'the shingle should be aligned with thoroughly cement the felts to each other with TAM-PRO orTAMKO
the top edge of the sawtooth of the.underlying shingle for a 5-5/8 in. Plastic Roof Cement from eaves and rakes to a point of a least 24 in.
exposure(see shingle application drawing illustrated on this panel), inside the interior wall line of the building.As an alternative,TAMKO's
When�ou make your final cut at the roof's edge;flip any pieces that Moisture Guard.Plus®self-adhering waterproofingunderlayment may
are 8 ir�.or longer back onto the roof.These pieces-can be worked be used in lieu of the cemented felts.
in anywhere without creating zippers or color variations.
NOTE:Do not align joints of-shingle courses when working in cut 7.MANSARD ROOF OR STEEP SLOPE ROOF
pieces Joints should be no closer than 4 in.from one another. If the slopeexceeds2l in.perfoot(60',each shingle must besealedwith
TAM-PRO SBS Adhesive or TAMKO-Tam-Seal Adhesive immediately
upon installation.Spots of cement must be equivalent in size to a$.25
piece and applied to shingles with a 5-5/8 in.exposure,use 6 fasteners
10-3/8" per shingle.See Section 3 for the Mansard Fastening Pattern.
8.R&ROOFINO
u 16-318 - 10-3/8° 29" Before re-roofing,.be certain to inspect the roof decks.All plywood
23" shall meet the requirements listed in Section 1..
29" Nail down or remove curled or broken shingles from the existing
_ 23" roof.Replace all missing shingles with new ones to provide a smooth
rake `s = 'Fun base.Shingles that are buckled usually indicate warped decking
10-318° or protruding nails_ Hammer down all protruding nails or remove
them and refasten in a new location. Remove all drip edge metal
5th course .
23" 1s�l8 and replace with new.
41h course 1--318"
If re-roofing over an existing roof where new flashing is required
3rd cou�e `23" to protect against ice dams(freeze/thaw cycle of water and/or the
2nd eo I 2s backup- backup of water in frozen or clogged.gutters),remove the old roofing
' as to a point at least 24 in. beyond the interior wall line and apply
lstco i 1-1318" TAMKO'sMoisture Guard Pluewaterproofing underlayment.Contact
*—eave TAMKO's Technical services Department for more information.
Measurements will vary when nesting over an existing 5 in.exposure
single roof:Call TAMKO Technical Services for further information:
Cut ywo ras course shingle m make 27 and We to 3.8'
1•length.Cyt a second shingle to make a 23•and The nesting procedure described below is the referred method for
a lf;. •1..,1h. 9 P P
1 to as. �
reroofing over existing metric size shingles with a 5=5/8 in.exposure.
See description below:
�•i ,s Starter Course:Remove the tabs and an additional portion from the
head of a full size shingle so that its height is equal to the exposure
of the existing shingles.Position the resulting strip over the existing
=, roof edge(with the factory-applied adhesive strip along the eaves).
Cut approximately 6 in.from the rake end and apply the remaining
portion at the eaves.Continue the starter strip by applying full length
shingle strips cut to height as above,evenly along the existing roof
at the eaves.The existing roof should overhang the eaves far
'n�n"
Z,,, Slytmfin wan a NV Lath sh'ugte.uryour,zs•,23•,,oaW.a„a,oara•longw enough to carry water off into the gutter.if this isnot the case,
As ycu ran sea.!Nee shingles wl!h Mn ats
makerne'caase" cut and apply the starter strip so that it witl provide.sufficient
overhang for proper drainage:
c°ns"us working'w"u,ayae'°s=the°°'. w""'"Y° " °Y°°
bnger ' First Course:Remove an amount from the butt edge of a full-size
3.final al at Bre nmfs edge,Sip elty places Vat are a'
back W.the n cf.T?pieces pan be worked"aM""ere wV-1 shingle so that the remaining portion of the shingle fits between the
croagrg zlppem wooly variadonc.
NOTE:Od naf atltpt)oints of shing10 codrses when w6rlin9 Inbutts.of the existing third course.This course must also be applied
cut pieces.Joints should be no loser than P from one—tt-.
evenly along the eaves edge of the new starter strip.
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
I Southeast District 230035th St., Tuscaloosa,AL 35401 800-228-2656
itamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3
(CONTINUED from page 3)
TAMKO HERITAGE 30
BDILDINS PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas,TX•Tuscaloosa,AL• Phillipsburg, KS • Joplin, MO
Second and Succeeding Courses: Remove 10-3/8 in.from the FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
rake end of the first shingle in the second course, and continue CONTACTTAMKO'S TECHNICAL SERVICES DEPARTMENT.
with fulwidth shingles for the remainder of the.course,,placing
the top edge of eachnew shingle against the butt.edge of the old Valle,�,;ne
Mf N.D mFt .-sl sheet
shingle in-the course above.This method should create an exposure n,Na�7 Fa:V,nnr;�
of 5-5/8 in.after the first course.When beginning the succeeding whenGuard Plus of oofir50 d end of sNn
or heavier moo maofirct ora�1 of firtmgho
course continue to follow the Heritage application instructions. I Kende dshrd.
12'-18•beyond
(See section 5), ae y uae�em
Existing shingles �
Underlaymvit ..- Notasterers.wiihin
\
61 of centerline
5 518'
.�
,\ 131/4 \ 1 !4 v
\ n 1/4
Drip edge
/�� Plar"a tip of shingle on the edge of
veanrti'ccNatg '�back Oriedge i � eaverng
-HQe.
New s75,518
es
,j
^ 5:5/8^exposure 10._HIP AND,RIDGE FASTENING DETAIL
expos
Apply the shingles with a 5 in.exposure beginning at the bottom
of the hip or from the end of the ridge opposite the direction of the
9.I►AI.LEY APPLICATION prevailing winds.Secure each shingle with one fastener on each side,
5-1'/2 in.back from the exposed end.and 1 in.up from the edge.
Overthe°shingle underlayment,center a minimum 36 in.wide sheet TAMKO recommends the use of TAMKO Hi & Ride shin le
of TAMKO Nail-Fast®,Moisture Guard Plus®or a minimum 50 lb.roll p g g
� products.Where matching colors are available,it is acceptable to
roofing n the valley.Nail the felt only where necessary to hold it in
place anthen only nail the outside edges: use.TAMKQ's Elite Glass-Seal,shingles cutdown to 12 in.pieces.
IMPORTANT:PRIOR TO INSTALLATION WARM SHINGLES TO Fastenersshould be 1Y4 in:_longer than the one used for shingles
PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING IMPORTANT. PRIOR TO INSTALLATION, CARE NEEDS TO BE
SHINGLES TO FORM VALLEY. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
Afterva�ey flashing is in place:
BENDINGSHINGLE IN COLD WEATHER.
• Ap Iy`the first course of shingles along the eaves of one of the Direction_of prevailing wind
intersecting roof planes and across the valley. start 51,exposure
Note :For proper flow of water over thetrimmed shingle,always here 1
start applying the shingles on the roof planeahat has the lower /\ \�✓�F stener
slope or less height.
'a
• Extend the end shingle at least 12 in.onto the adjoining roof. I I Start /
Ap�ply succeeding courses in the same manner-extending them here 5°exposure
acrss the valley and onto the adjoining roof.
• Press the shingles tightly into the valley: THESE ARE THE MANUFACTURER'S APPLICATION
ib INSTRUCTIONS FOR THE ROOFING CONDITIONS
Use normal shingle fastening methods. DESCRIBED:TAMKO BUILDING PRODUCTS, INC.ASSUMES
-Note.No fastener should bgwithin 6 in.of the valley centerline, NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
an -two fasteners should be placed at the end of each shingle DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
crossing the valley. MANUFACTURER'S INSTRUCTIONS.
�
• To the adjoining roof plane;apply one row of.shingles vertically
facing the valley:and 2 in.back from the valley centerline.
Ndte• For a neater installation, snap a chalkline over the TAMKOR;MoistureGuard PlusO.Nail Fast&TAWPRO�and Heritag�n are registered
• p trademmarks:ofTAMKO Building Products,Inc.
sh ng es for guance. Information included in these application instructions was current at time of printing.To
• To complete the valley, apply shingles on the adjoining roof obtain a copy of the most current ansion of these application Instructions,visit us ontine
pl a by positioning the tip.of the first shingle of each row at attamko.com orcall us at aeo-641-4691:
the 2 in.;pointfrom the centerline where the edge of the vertical
shingle has been applied,covering the vertical shingle.
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09
Visit Our Web Site-at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
t If1 ko.com Southwest District 7910 S.Central Exp., Dallas;TX 75216 .800-443-1834
Western District 5300East43rd Ave., Denver,CO 80216 800-530.8868