Loading...
HomeMy WebLinkAboutProduct Approval roll 144 1111DIL Av—�llll es ECEID JUN C76 1F tit &Pusiiness ♦ Professimall Regulation Florida Depaitmentof BCIS Home Login I User Registration I Hot Topics l Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search Busines (� Professi I 5 °+Product Approve) LE USER:Public User COPY Regulation Product Aooroyal Menu>Product or Application Search>Application List>Application Detail • FL# FL10674-R11 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Coming Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email i Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Add ress/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer C) Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W.Knezevich,PE �� Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R11 COI 2015 01 COI Nieminen.Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code EXTERIOR RESEARCH &DESIGN,I.I.C. Certificate of Authorization#9503 TRINITY� ® 353 CHRISTIAN STREET,UNIT#13 ERD OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-116 One Owens Corning Parkway FL10674-R11 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 6: 10/15/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein. 0—Me Owens Cornin As halt Roof Shinrgles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPUAKE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: olttt¢4syi" .`��C'�•VI' 'ri''a .�.tea�'�,n'=_�:�,•'T� 4�...... ^'{^�` The facsimile sea$a Robert J.M.Nieminen,P.E. ^.;rry�s:".•y�'y: appearing was snots rveasdbyRohertNieminen, ���C4L1 4��a+`:>• P.E.on 10/15/7A35.This does not serve as an electroniwly signed Florida Registration No.59166,Florida DCA ANE1983 document.signed, This hardcopies have been transmitted to the Product Approval Administrato rand to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. QTRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Enti Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. m 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireTM'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration', Duration Premium Coot, TruDefinifiion Duration® Designer Dolor Col(ecrion,TruDefinition"Oakridge;OakridgeR and WeatherGuard HP are fiberglass reinforced,laminated asphatt roof shingles. 4.2 Berkshir;7 Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard HP Hip & Ridge Shingles,ProEdge Hip&Ridge Shingles and DuraRidgem Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 Certificate ajAuthoriiatian#9503 FL10674-R11 Revision 6:10/15/2015 Page 2 of 7 TRINFY f ER® 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph (Vait=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph (V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 611320-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: ➢ Berkshire®shingles require minimum five(5)nails per shingle. ➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle. ➢ DevonshireTM'shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feltunderlayment Deck Feltundetayment geek Self-adhered Weathettockfl Self-adhered undedaymem WeatherLoclP underlayment Drip edge �Dri Drip edge Drip— ede g Nails located Nalls located 2 2"-3"from eave '-3'from eave Install first Self-searing adhesive Salkealing adhesive Starter Strip positioned along eave Insteg first Starter Strip Pin positioned along eave shingle Mf -\ wkh V removed 6"removed Starter Strip shingle overhangs eaves and rakes'W=W Starter S p Plus overhangs eaves and rakes IM-214' Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116 Certificate ofAuthor"nation#9503 FLICS74-R11 Revision 6:10/15/2015 Page 3 of 7 .t t d TRINITY I ER® 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area.para Normal Mansard or Area.pars Wind Areas High Wind desvanes y Wind Areas High Wind desvanes-y Area pare vientos nornrates Areas vierrtos faertes Area para vientos normaies Areas vientos fuerres �`��; IA) »°�• �I". z� IB z• r. sir 1A1 tz t r I r z' i61 z• r� . . , 5"Exposure 65/8"Exposure Exposicidn Exposigidn 6.2.7 Minimum Nailing—Berkshire®: SealaN strip SeaFaidstrip to tira de se" 1a lba de selladar — �t---��-'t----! � t---►-•4---->`� �f—a•�s—s• .fit--►�f---►• S Yz"' 9 Vf 9-VP 8 Yf 8-11T 8Y' 8 Yf 8 Vf 2 Asphalt roof"jCmi-ent Cemento de t060 do astafto 6.2.8 Minimum Nailing—DevonshiWm: 47 4T Nails r r s e r r r r r r Nails Ten 1"Spots of Asphaft Roof Cement Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116 Certificate ofAuthoriiation#9503 FL10674-R11 Revision 6:10/15/2015 Page 4 of 7 .I TRIM-l(!ER® 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition■ Duration'Designer Color Collection: 4 WagPattern6 Nat? tot3mardand sbepslope mstmtxtW4MSurrJa�° Esquemado4 davos Pattern arm andtap of rut a td. Esguema — t,-,,n4 opmdwgs Sureflaideda s ateavridth de6elavos a�od 19NZ_0 d Area dedar�osSLreNaOe a. • • �arswe;laa�rbya}e ' :mye:ia rxlraxrtz 1' T SuruMad° \ \ SarJait' taste. - tastmu3 arratiPdtnClam areauvi�t, Sures dQ 17 LE 5W ExposureNat7s, SW Exposure P3faptt(g,deexposidda Claws 61hputg.deexposiordn 53'e Exposure Nalls 5ye"Exposure 6%pulg.de exposici6n Davos 5+h pulp.de exMsiddn 6.2.10 ` Minimum Nailing—TruDefin tlon'OakKridge ;0akri 4 fail Pditern p k �+ r� x &Nail Pattern E.Squean toJ14 ctavos } vfV, Esquama ecn;G lavas F06P ��N_I--W_I I S5 Expasuro NaLs 'S1$"Exposute, , -. t�� Ezpesr de S;JSpra'g Cler Fspasi'a de 5 'S ga 5518 Ex rte Carr S 518"Expo3rtJa Erpas?cidu daP6lBpulg. Exposrsiu0 de 6'SfBpJa'g. 6.2.11 Minimum Nailing—WeatherGuard®HP: �■ Single Side View ,.:as .has •••,�:, :i:=:• •:• F+a—7lttnr NrlLir: L�in 6fi ra 3de tlsdin 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles,High Ridge,Hip&Ridge with Sealant,WeatherGuard'HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidgeTm Hip & Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6 Certificate ofAuthariradan✓/9503 FL10674-R31 Revision 6:10/15/2015 Page 5 of 7 1 i TRINITY!ER® 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 Fig.2 f—-Remr.9VAnd D'nedlsn A. T ToPlfiesl WeYl— Nails— ). Q. T Nals Malls 4 Top LaninaieU' 4' pil 4��\ ZK I 1 i I I JI i � r ExPoswo � I �I I I I I 1 Minimum Nailing—Hip&Ridge with Sealant; R� m 6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&.Ridge Shingle Faslening Fig.A 4 4 TopVbw pRYaoNg Wall t—Olnstbn A P 1lalls 114 4 A i i Nails HAS p I T 27 -11 I I I I r r P I I i 1 I I I I 6 EIpO:nlre BEYpO5Un3 17' I Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 Certificate of Authorization#9503 FL10574-R11 Revision 6:10/15/2015 Page 6 of 7 t i TRINITY ER® 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind Direction Sejant Strip Fastening Pattern 6°Exposure � Sealant Fasten 711? 7y:' 6"Exposure Cover Exposed 1 11 Fasteners with Roof Cement 6.3.7 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Provaiing Wind DirocSm Top VI Dirnaiondxninmta dcn uvt HII- V[sm u�eriw I'IH Dirncd8n dol vicnto pr•dwnifantu 7! cl.. 2 e � '. �Oticns Co7ri SurePlwT • QO1O cNcaik-�� s n9 n I I I I 1 I I it I�« ala OVA I a 12-- 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 20. QUALITY AssURANCE ENTITY: UL LLC—QUA9625;(414)248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116 Certificate of Authorization/19503 FL10674-R11 Revision 6:10/15/2015 Page 7 of 7