• FL# FL10674-R11
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email i Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Add ress/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
C) Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W.Knezevich,PE
�� Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R11 COI 2015 01 COI Nieminen.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
EXTERIOR RESEARCH &DESIGN,I.I.C.
Certificate of Authorization#9503
TRINITY� ® 353 CHRISTIAN STREET,UNIT#13
ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-116
One Owens Corning Parkway FL10674-R11
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 6: 10/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein.
0—Me Owens Cornin As halt Roof Shinrgles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPUAKE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the
referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by: olttt¢4syi"
.`��C'�•VI' 'ri''a
.�.tea�'�,n'=_�:�,•'T�
4�...... ^'{^�` The facsimile sea$a
Robert J.M.Nieminen,P.E. ^.;rry�s:".•y�'y: appearing was snots rveasdbyRohertNieminen,
���C4L1 4��a+`:>• P.E.on 10/15/7A35.This does not serve as an electroniwly signed
Florida Registration No.59166,Florida DCA ANE1983 document.signed, This
hardcopies have been transmitted to the
Product Approval Administrato rand to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
QTRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Enti Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
m
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 DevonshireTM'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration', Duration Premium Coot, TruDefinifiion Duration® Designer Dolor
Col(ecrion,TruDefinition"Oakridge;OakridgeR and WeatherGuard HP are fiberglass reinforced,laminated
asphatt roof shingles.
4.2 Berkshir;7 Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard HP Hip & Ridge
Shingles,ProEdge Hip&Ridge Shingles and DuraRidgem Hip&Ridge Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6
Certificate ajAuthoriiatian#9503 FL10674-R11
Revision 6:10/15/2015
Page 2 of 7
TRINFY f ER®
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for
us in all wind zones up to Vasd=150 mph (Vait=194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasd=150 mph (V„it=194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 611320-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following
exceptions:
➢ Berkshire®shingles require minimum five(5)nails per shingle.
➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle.
➢ DevonshireTM'shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Feltunderlayment Deck Feltundetayment geek Self-adhered
Weathettockfl
Self-adhered undedaymem
WeatherLoclP
underlayment
Drip edge
�Dri Drip edge Drip—
ede
g
Nails located Nalls located
2
2"-3"from eave '-3'from eave
Install first Self-searing adhesive Salkealing adhesive
Starter Strip positioned along eave Insteg first Starter Strip Pin positioned along eave
shingle Mf -\ wkh V removed
6"removed
Starter Strip shingle overhangs eaves and rakes'W=W Starter S p Plus overhangs eaves and rakes IM-214'
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116
Certificate ofAuthor"nation#9503 FLICS74-R11
Revision 6:10/15/2015
Page 3 of 7
.t
t
d
TRINITY I ER®
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard or Area.para Normal Mansard or Area.pars
Wind Areas High Wind desvanes y Wind Areas High Wind desvanes-y
Area pare vientos nornrates Areas vierrtos faertes Area para vientos normaies Areas vientos fuerres
�`��; IA) »°�• �I". z� IB z• r. sir 1A1 tz t r I r z' i61 z• r�
. . ,
5"Exposure 65/8"Exposure
Exposicidn Exposigidn
6.2.7 Minimum Nailing—Berkshire®:
SealaN strip SeaFaidstrip
to tira de se" 1a lba de selladar
— �t---��-'t----! � t---►-•4---->`� �f—a•�s—s• .fit--►�f---►•
S Yz"' 9 Vf 9-VP 8 Yf 8-11T 8Y' 8 Yf 8 Vf
2 Asphalt roof"jCmi-ent
Cemento de t060 do astafto
6.2.8 Minimum Nailing—DevonshiWm:
47 4T
Nails
r r s e r r r r r r
Nails Ten 1"Spots of Asphaft Roof Cement
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116
Certificate ofAuthoriiation#9503 FL10674-R11
Revision 6:10/15/2015
Page 4 of 7
.I TRIM-l(!ER®
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition■
Duration'Designer Color Collection:
4 WagPattern6 Nat? tot3mardand sbepslope
mstmtxtW4MSurrJa�°
Esquemado4 davos Pattern arm andtap of rut a td.
Esguema — t,-,,n4 opmdwgs
Sureflaideda s ateavridth de6elavos a�od 19NZ_0 d
Area dedar�osSLreNaOe a. • • �arswe;laa�rbya}e
' :mye:ia rxlraxrtz
1' T SuruMad° \ \ SarJait'
taste. - tastmu3
arratiPdtnClam
areauvi�t,
Sures dQ 17
LE
5W ExposureNat7s, SW Exposure
P3faptt(g,deexposidda Claws 61hputg.deexposiordn
53'e Exposure Nalls 5ye"Exposure
6%pulg.de exposici6n Davos 5+h pulp.de exMsiddn
6.2.10 ` Minimum Nailing—TruDefin tlon'OakKridge ;0akri
4 fail Pditern p k �+ r� x &Nail Pattern
E.Squean toJ14 ctavos } vfV, Esquama ecn;G lavas
F06P
��N_I--W_I I
S5 Expasuro NaLs 'S1$"Exposute, , -. t��
Ezpesr de S;JSpra'g Cler Fspasi'a de 5 'S ga 5518 Ex rte Carr S 518"Expo3rtJa
Erpas?cidu daP6lBpulg. Exposrsiu0 de 6'SfBpJa'g.
6.2.11 Minimum Nailing—WeatherGuard®HP:
�■
Single Side View
,.:as .has •••,�:,
:i:=:• •:• F+a—7lttnr NrlLir:
L�in 6fi ra 3de tlsdin
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles,High Ridge,Hip&Ridge with Sealant,WeatherGuard'HP
Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle. Installation of DuraRidgeTm Hip & Ridge Shingles
shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer
to Owens Corning published information on wind resistance and installation limitations,including the use
of hand-sealing for wind warranties.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate ofAuthariradan✓/9503 FL10674-R31
Revision 6:10/15/2015
Page 5 of 7
1 i
TRINITY!ER®
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
f—-Remr.9VAnd
D'nedlsn A. T ToPlfiesl WeYl—
Nails— ). Q. T Nals Malls
4
Top LaninaieU'
4' pil
4��\
ZK
I 1 i
I I JI
i � r
ExPoswo � I
�I
I
I
I
I
1
Minimum Nailing—Hip&Ridge with Sealant;
R� m
6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.C Hip&.Ridge Shingle Faslening
Fig.A 4 4 TopVbw
pRYaoNg Wall t—Olnstbn A
P
1lalls 114 4
A i i Nails HAS
p I T
27
-11
I I I I r r
P I I i 1
I I I I
6
EIpO:nlre
BEYpO5Un3
17' I
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6
Certificate of Authorization#9503 FL10574-R11
Revision 6:10/15/2015
Page 6 of 7
t
i
TRINITY ER®
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard
Wind Direction Sejant Strip Fastening
Pattern
6°Exposure �
Sealant
Fasten 711? 7y:'
6"Exposure
Cover Exposed 1 11
Fasteners with
Roof Cement
6.3.7 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens
Corning published installation instructions for their minimum requirements.
Provaiing Wind DirocSm Top VI
Dirnaiondxninmta dcn
uvt HII- V[sm u�eriw I'IH
Dirncd8n dol vicnto pr•dwnifantu
7!
cl..
2 e � '. �Oticns Co7ri SurePlwT • QO1O
cNcaik-��
s n9
n I
I I
I 1
I I it I�«
ala
OVA
I
a 12--
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
20. QUALITY AssURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT-