Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online rage i or s i i Florida Departmentq BCIS Home Login I User Registration I Hot Topics I Submit Surcharge ; Stats&Facts I Publications FBC Staff SCIS Site Map Links Search Business -=g. Pror I nal ii°� P SE bct Approval User Regulation Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL7271-R3 '- Application Type Revision Code Version 2014 Application Status Approved Comments Archived D Product Manufacturer UNION CORRUGATING COMPANY Address/Phone/Email 701 S.KING ST. FAYETTEVILLE,NC 28301 (910)483-0479 Ext 256 jstleby@unioncorrugating.com Authorized Signature John Stieby jstleby@unioncorrugating.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer u Evaluation Report-Hardcopy Received U Florida Engineer or Architect Name who developed the Bala Sockalingam Evaluation Report Florida license PE-62240 I Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/31/2020 Validated By Yoosef Lavi,P.E. J Validation Checklist-Hardcopy Received Certificate of Independence FL7271 R3 COI CertificateIndependence.odf Referenced Standard and Year(of Standard) Standard Year ASTM E1592 2001 FM 4470 1992 UL 1897 1998 UL 1897 2004 UL 580 1994 UL 580 2006 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL7271 R3 Epuiy TestEouivalent 7271 UL.pdf FL7271 R3 Eciuiv TestEouivalent C1999 19.pdf Sections from the Code ht p://wvl vw.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvtEeYw06EIO... 5/27/2016 FL 7271.6-R3 C1999-14 3.20.15 Page 2 of 3 Manufacturer: Union Corrugating Company ' I Product Name: -Advantage-Lok 11 Panel Pane I I Description: ✓.Max. 16" wide coverage with 1" high ribs Materials: /Minimum 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 7/16" thick OSB or min./15/32" thick APA rated plywood or min. W thick wood plank (min SG of 0.42) for new and existing constructions.Designed by others and installed as per FBC 2014. New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1. Required for new construction. Exis,ing Underlayment: Vone layer of asphalt shingles over one layer of 930 felt. For reroofing (Optional) construction only. Slope: 4/2:12 or greater in accordance with FBC 2014 Section 1507.4.2 Design Uplift Pressure: /52.5 psf @ panel fastener spacing of 6" o.c. along seam (Factor of Safety=2) 112.5 psf @ seam fastener spacing of 6" o.c. along seam with 3/16" diameter bead sealant in panel seam ii Panel Attachment: #10-12 pancake head wood screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of Seam"� Iant: Sikaflex-201 Sealant. In lieu of Sikaflex, adhesive/sealant with greater or equal tensile properties may be used. Test Standards: Roof assembly tested in accordance with UL580-06 'Uplift Resistance of Roof Assemblies' & UL1897-04 'Uplift Tests for Roof Covering Systems'. Coda Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. /Fhe maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this FL 7271.6-R3 C1999-14 3.20.15 Page 3 of 3 Evaluation Report. Refer to FBC 2014 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL5 80 &UL 1897 Test Reports PRI Construction Materials Technologies UCC-006-02-1 Rev 1,Reporting Date 2/10/12 OMWN 6Y: IwEcn.BY: J.S. PLOT: BATC PANEL FASTENER NEW UNDERLAYMENT "-SEE DETAILS 1 & 2 PANEL OVERLAP 0 MAX. 6" O.C. Rr. THIS SHEET ROOF PANEL II 0 v OSB 7/16-THICK (MIN.) OR EXISTING UNDERLAYMENT EXISTING SHINGLESPLYWOOD 15/32' THICK (MIN.) (OPTIONAL) (OPTIONAL) '-DECK ATTACHMENT AND SUPPORTS MUST BE zT1 DESIGNED AND INSTALLED BY OTHERS RAFTER/JOIST/TRUSS AT MAX. 24" D.C. 0 TYPICAL PANEL INSTALLATION X—SECTION (7 ISM-IOU) Z ()�"m oz af af ;zn R_,Lj00 MIN 26 GA. PANEL 0 0 ALLOWABLE UPLIFT PRESSURE Z E;LF, #10-12 PANCAKE HEADz FASTENER SSEAM PRESSURE nti WOOD FASTENER SPACING EALANT (PSF) NEW UNDERLAYMENT EXISTING SHINGLES ALONG.RIB DIAMETER (OPTIONAL) 6' NONE 52.5 Vui/ oa 6' 3/16- 112.5 o' EXISTING UNDERLAYMEWNT (OPTIONAL) 1 OSB 7/16 THICK (MIN.) OR 3 DETAIL PLYWOOD 15/32" THICK (MIN.) oz ,A -s o SIKAFLEX 201 SEALANT OR EQUIVALENT GENERAL NOTES: MIN 26 GA. PANEL--,",,, 3/16" BEAD 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ALL ROOF PANELS ARE SHALL BE 26 GA. EFFECTIVE COVERING WIDTH OF #10-12 PANCAKE HEAD OF PANEL = 16". WOOD FASTENER 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS NEW UNDERLAYMENT SPECIFIED ON THIS DRAWING. EXISTING SHINGLES 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. (OPTIONAL) THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. _EXISTING_UNDERLAYMENT —6.RAF-TERS/iols-rS/­TRUSSES-MUST-BE—DESIGNED-TO-WITHSTAND-WIND-LOADS-AS-- (OPTIONAL) OSB 7/16-THICK (MIN.) OR REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. DETAIL 2 PLYWOOD 15/32- THICK (MIN.) 0DWINGN104 RM SHEET ND. 1 OF