Loading...
HomeMy WebLinkAboutEngineering PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W.Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone(772) 785 -9888 Email pwelchinc@aol.com June 7,20 6 Re: Jones Re-Roof 10725 S. Ocean Drive Unit 261 Jensen Beach,FL 34957 SCOPE OF WORK: Remove existing roofing and install new 5-V Crimp Metal Roof(Gulf Coast Supply& Manufacturing FL# 11651.13) at above referenced residence address over new underlayment and existing-plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT=9'-0" A=3' MEAN ROOF HIEGHT=<20' ROOF ANGLE=4:12 SHAPE=PITCHED HIP IMPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=D ENCLOSURE CLASS =ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (nsf): ZONE 1 (Field)=-44.7 ZONE 2 (Perimeter/Ridge)_-75.5 ZO 3 (Corners)_-110.8 ;,>i .rr - _ ��Ful Welch Inc. "Paul,'elch P E Reg.No. 29945 '-7,2016 10725 S.Ocean Drive Unit 261 Jensen Beach,FL 34957,: ', ��!�.%11.1,�,<�. �' 1 of 3 ATTACHMENT REOUIREMENTS: Metal roofing to be attached with#9- 15 x 1 1/2"long(minimum 1/a"penetration through plywood sheathing)Woodgrip screws with weather sealing washers spacing as follows: ALL FASTENERS IN THE FLAT OF THE PANEL ZONE 1 (Field): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 2 (Perimeter/Ridge): Fasteners adjacent to ribs.one side(Type 1 per product approval) at 16" O.C. ZONE 3(Corners): Fasteners adjacent to ribs both side(Type 2 per product approval) at 16"O.C. Zones 1 &2 Design uplift Pressure: -94.25 psf Zone 3 Design uplift Pressure: - 131.0 psf Zones 1 &2: 94.25 >75.5>44.7 Therefore O.K. Zone 3: 131.0> 110.8 Therefore O.K. NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. UNDERLAYMENT : Underlayment shall be Polyglass USA,Inc. FL#5259.1 "Polystick TU Plus". Polystick TU Plus shall)be installed in compliance with the codified requirements for ASTM D 1970 underlayment in FBC Section 1507. All seal-lap seams must be firmly rolled with a minimum 281b.hand roller to ensure full contact and adhesion. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4"O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL#-11651.13), (FL# 5259.1), manufacturer's specifications, and the Florida Building Code_'L014. - Paul Welch Inc. Paul Welch P.E. Reg.No. 29945 =June 7,2016 10725 S.Ocean Drive Unit 261 Jensen Beach,FL 34957 2 of 3 � Q Z 11, v � � A A ROOF ZONE PLAN A=3' 10,Q,Q=ZONE DESIGNATION'(TYPICAL) NOTE: CONTINUOUS APPROVED LAP SEALANT_ TST DE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12: Paul Welch Inc. _ aul Welch P.E. Reg.No. 29945 .- June 7,2016 10725 S.Ocean Drive Unit 261 Jensen Beach,FL 34957 3 of 3