Loading...
HomeMy WebLinkAboutENGERY CALC I t, " c _ Planning&Development Services Department • Building&Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance Project Name: SAVANNA CLUB HOUSE INC. Project Address: 3150 CRABAPPLE DRIVE PORT ST. LUCIE, FLORIDA Permit#: Occupancy Type: A-2 Construction Type:11-B INSTRUCTIONS FOR USE: i • This certification must be completed,signed,and sealed by the design professional of record. • Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) +',I o Residential Addition of o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#;above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as(check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 165 mph ASD X LRFD End Zone Widt1.h: 6 ft 5. Mean Roof Height 22 ft Roof Pitch: 6 :12 Parapet: ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly,label on all plan openings): Zone 1:34,-36 Zone 2: 34,-63 Zone 3: 34,-93 Zone 4:38,42 Zone 5:30,-49 Garage: X 7. Design Loads: Floor: 100 PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: x PSF X X X X �'�� X Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not: DOOR CHANGE-OUT ONLY 9. Is A Continuous Load Path Provided? Yes X Not Applicable Explain Why Not: DOOR CHANGE-OUT ONLY 10. Design Soil Bearing Pressure: NSA PSF Soil Test Reports Submitted? NSA Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,to the best of my knowledge and belief, the attached plans &specifications have been designed to comply with the applicable structural portions of the building codes currently adoptedjand enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: GARY L. KAREL P.E. f1_451406 Print Name Cert#&Co.Cert Auth. Via/ "Sign ui�D e,and Seal G. L. KAREL SOLE PROPRIETOR - - Company Name&Address Revised 07/25/2014 11 'i �I