Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit Application
ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 6.10.16 Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial X Residential PERMIT APPLICATION FOR: Mechanical PROPOSED IMPROVEMENT LOCATION: Address: 2180 Mariposa Ave Port St Lucie FI 34952 Legal Description: St Lucie Gardens 12 37 40 Bilk 4 N 200ft of lot 1less in 20 It and less E 20 ft and less of that part of lot 1 Property Tax ID #: 3414.501.5001.020.6 Site Plan Name: Project Name: United Rentals Setbacks Front Back: Supply / install replacement 5 ton unit Right Side: Left Side: Lot No. Block No. Aa amonaiworxcooe nerTormea unaermispermn— cnecrcau appry: ❑✓— HVAC _ Gas Tank E]Gas Piping _ Shutters Windows/Doors 11 Electric Plumbing []Sprinklers Generator Roof Total Sq. Ft of Construction: SqI -Ft�. of First Floor: Cost of Construction: $ 6300.00 Utilities:nSewer ESeptic Building Height: OWN ER/LESSEE: US Rentals Inc CONTRACTOR: Stryker Electric & Air Inc Name US Rentals Inc Name: Alfonse Santoro Address: 2180 SE Mariposa Ave Company: Stryker Electric & Air Inc City: Port St Lucie State: A Zip Code: 34952 Fax: Phone No. 772.398.9788 Address: 4241 SW High Meadows Ave City: Palm City State: FI Zip Code: 34990 Fax: 772.219.3242 Phone No. 772.219.3389 x 121 E -Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E -Mail: service@stryker-electric.com State or County License: CAC1813250 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: x Not Applicable Name: MORTGAGE COMPANY: x Not Applicable Name: Address: Address: City: State: Zip: Phone: City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: x Not Applicable Name: BONDING COMPANY: X Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording vour Notice of Commencement. _ Sigy(ature of Owner/ Lessee/Agent STATE OF FLORIDA COUNTY OF Mahn The f oing instr nt w acknowledge before me this ray of , 20 = (Signature of Notary Personally Known \ Type of Identification Commission No. Revised 07/15/20 OR Produced Identification MY COMMISSION # EE863426 STATE OF FLORIDA COUNTY OF Mahn The f oing instr ment as acknowledged ' before me this 11 day of , 20 l 1 O by of person of ng ) ry Public- State of Florida ) Personally Known OR Produced Identification Type of Identification Commission No. MY COMMISSION 4 EE863426 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS � CERTIFIED0 Certificate of Product Ratings AHRI Certified Reference Number: 7482178 Date: 6/7/2016 Product: Split System: Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 4TTR406OLl Indoor Unit Model Number: TEM4AOC6OS51+TDR Manufacturer: TRANE Trade/Brand name: TRANE Region: All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015, are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016, central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. Series name: XR14 Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240.2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 54500 EER Rating (Cooling): 11.70 SEER Rating (Cooling): 14.00 IEER Rating (Cooling): ' Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridlrectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; .■ ' entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridlrectory.org, click on "Verify Certificate" link we make lite better^° and enter the AHRI Certified Reference Number and the dale on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. 131097973904169157 CERTIFICATE NO.: ©2014 Air-Conditioning, Heating, and Refrigeration Institute TRAM' Product Specifications OUTDOOR UNIT(.) (b) 4TTR406OL1000A POWER CONNS.—V/PH/HZW 208/230/1/60 MIN. BRCH. CIR. AMPACITY 31 BR. CIR. PROT. RTG. — MAX. (AMPS) 50 COMPRESSOR CLIMATUFFO-SCROLL NO. USED — NO. STAGES 1-1 VOLTS/PH/HZ 2084ZILl 60 R.L. AMPS (a)—L.R. AMPS 23.7-152.5 FACTORY INSTALLED START COMPONENTS (e) NO (Uses BAYKSKT263) INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOORFAN PROPELLER DIA. (IN.) — NO. USED 27.5-1 TYPE DRIVE— NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. (0 4340 NO. MOTORS — HP 1-1/5 MOTOR SPEED R.P.M. 835 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 1.05 OUTDOOR COIL—TYPE SPINE FIN— ROWS —F.P.I. 1-24 FACE AREA (SQ. FF.) 24.93 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. —R -410A(0. D. UNIT)(9) 7LBS., 10 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.) 42.4 x 35.1 x 38.7 WEIGHT SHIPPING (LBS.) 246 NET (LBS.) 211 Bl�I:C frI:Ir]IQg�1=b1-��01 (a) Certified In accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (e) Rated in accordance with AHRI standard 270. W Calculated in accordance with Nati. Elec. Codes. Use only HACR circuit breakers or fuses. (a) This value shown forcompressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse we. The value shown is the branch circuit selection current. W No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. M Standard Air — Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (n) Max. linear length 60 ft.; Max. lift — Suction 60 R.; Max. lift—Liquid 60 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0* (* denotes latest revision). k TRANE' Product Specifications MODEL TEM4AOC60551SA RATED VOLTS/PH/HZ 208-230/l/60 RATINGS(0 See O.D. Specifications INDOOR COIL — Type Plate Fin Rows — F.P.I. 4.14 Face Area (sq. f.) 5,91 Tube Size (in.) 3/8 Refrigerant Control TXV Drain Conn. Size(ln.)(e) 3/4 NPT DUCTCONNECTIONS See Outline Drawing INDOOR FAN—Type Centrifugal Diameter -Width (In.) 11X10 No. Used 1 Drive - No. Speeds Direct -3(0 CFM vs. in. w.g. See Fan Performance Table No. Motors— H.P. 1-3/4 Motor Speed R.P.M. 1050 Volts/Phi 208-230/1/60 F. L. Amps 6.3 FILTER BAYHTR1510PDC, Filter Furnished? (d) No REFRIGERANT R -410A Ref. Line Connections Brazed Coupling or Conn. Size— In. Gas 7/8 Coupling or Conn. Size— In, Llq, 3/8 TEM4A0C60-SUB-IA-EN DIMENSIONS H x W x D Crated (In.) 52-1/2 x 26 x 24 Uncrated 51-3/8 x 23-1/2 x 21-1/8 WEIGHT Pump Shipping (Lbs.)/Net (Lbs.) 145/138 0) These Air Handlers are A.H,R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. (a) 3/4" Male Plastic Pipe (Ref: ASTM 1785-76) I-) ECM Motor (a) Remote filter required. Minimum Airflow CFM 7EM4A0C60SS1SA Heater Minimum Heat Speed Tap With Heat Without Heat Pump Pump BAYHTR1504BRK, BAYHTR1504PDC, BAYHTR1504LUG, Low Law BAYHTR1505BRK, BAYHTR1505PDC, BAYHTR1505LUG BAYHTR1508BRK, BAYHTR1508PDC, BAYHTR1508LUG, BAYHTR1510BRK, Low Low BAYHTR1510PDC, BAYHTR1510LUG, SAYHTR351OLUG BAYHTR1515BRK, BAYHTR3515LUG, Low Low BAYHTR1520BRK Low = Taps 1-3 Ash-, TIA E' Performance and Electrical Data Table 2. Electrical Data TEM4AOC60S51SA 240 Volt 208 Volt No. of Capacity Capacity Mink Heater Model No. Circuits/ Heater Minimum Maximum Heater mum Maximum Phases Amps Circuit Overload Amps Circuit Overload kW Biper Ampaclty Protection kW BTU per Ampacl- Protection R CIrrcuit circuit ty No Heater 6.0- 8 15 6.0- S 15 BAYHTR1504BRK 131- BAYHTR1504PDC 1/1 3.84 16.0 28 30 2.88 9800 13.8 25 25 BAYHTR1504LUG 00 BAYHTR1505BRK_ 10604 _ 100 BAYHTR1505PDC 1/1 4.8 20.0 33 35 3.6 17.3 30 30 BAYHTR1505LUG BAYHTR1508BRK 20602_ 100 _ BAYHTR1508PDC 1/1 7.68 32.0 48 50 5.76 27'7 42 45 BAYHTR1508LUG BAYHTR1510BRK 1/1 9.6 _ 3Q� 40.0 58 60 7.2 24600-34.6 51 60 BAYHTR1510PDC BAYHTR1510LUG BAYHTR1515BRK- 328 246 Circuit 1 W 2/1 9.6 00 40.0 58 60 7.2 00 34.6 51 60 BAYHTR1515BRK- 4.8 164- 20.0 25 25 3.6 123 17.3 22 25 Circuit 2 00 00 BAYHTR3520BRK- 328 246 Circuit 1 f•) 9.6 00 40.0 58 60 7.2 00 34.6 51 60 2/1 SAYHTR15206RK- 328 246 Circuit 2 9.6 00 40.0 50 50 7.2 00 34.6 43 45 1/3 328 246 BAYHTR351OLUG 9.6 00 23.1 36 40 7.2 00 20.0 32 35 BAYHTR3515LUG 1/3 14.4 9134.6 50 50 10.8 300 69- 30.0 44 45 BAYHTR1515BRK with single circuit 1/1 14.4 491 60.0 83 90 10.8 369-51.9 73 80 power source kit 00 00 BAYSPEKT201A BAYHTR1520BRK with single circuit 1/1 19.2 655- 80.0 108 110 14.4 491 69.2 94 100 power source kit 00 00 BAYSPEKT201A * = Motor Amps 0) MCA and MOP for circuit 1 contains the motor amps. TEM4A0C60-SUB-1A-EN