HomeMy WebLinkAboutProduct Approval rlonda building Code Online Page 1 of 2
- a
y ' uYo.N13nt r .
rlorit-b Deparment` BCIS Home ; Log In User Registration Hot Topics I Submit Surcharge Stats&Facts Publications ? FBC Staff , BCIS Site Map Links tl.i Search
Busines.'�
Professiol _ }PERduct Approval
na
Regulation
Product Aoprovai Menu>Product or Application Search>Application List>Application Detail
� � FL# FL10674-R11
o ,�, Z
�3f Y F S Application Type PP YP Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
g reg,keeler@ owenscom 1 n g.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Emall
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M.Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W.Knezevich,PE
`j Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 RIJ COI 2015 01 COI Nieminen pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 5/12/2016
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certycate of Authorization#9503
' TRINITY
353 CHRISTIAN STREET,UNIT#13
ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02,12-R6
One Owens Corning Parkway FL20674-R11
Toledo,OH 43659 Date of issuance:02/06/2012
Revision 6: 10/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the Still Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.If the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
AOvERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in Its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or Its
distributors and shall be available for Inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by: wsctttri„rr --
or A
•+`�s•'%4=^.b�tir*�^ Thefacsimileseal appearing was authorized byRobert Nieminen,
Robert J.M.Nieminen,P.E. �,•Fssr �',�
j,+,}.�+atitip P.E.on 14(]5(2015.This does rot serve as an electronically signed
Florida Registration No.59166,Florida DCAANf190 document SIgned,sealedhardcoplesbavebeen transmitted tothe
Product Approval Administrator and tothe named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will It acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
/�
N U�IU�0 U 8 ����| �^��
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,asproduced byOwens Corning,have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing hmaccordance with the following Standards. Compliance issubject to the Installation Requirements
and Limitations/Conditions ofUse set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM Ds4s2 3009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM Do1a1 200e
1507.2.7.1,R905.2.6.2 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Entity Examination Referenc Date
ULLLC ycEn9aaa> Physicals&Wind Resistance File na4sa,Vol.a 02/15/2007
uLuc(CEe9626) physicals&Wind Resistance 20120516-R24S3 05/16/2012
UL LLC(TST9628) Physical Properties 06Cx24263 04/18/2006
uLLLC OSJg6zg> Wind Resistance zIcA34308 02/18/2012
VL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
ULLLC(TST96l8) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL Luc(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER15A2) FaCHVHICompliance VoriouoNOAo Various
uLLLC (4Vxgaa5) Quality Control Service Confirmation,Ra4ss sxp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic*and Supreme*are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire*are fiberglass reinforced,4-tohasphalt roof shingles.
4.1.3 Devonshine`°are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration*, Tr Definkion" Duration*, Duration' Premium Cool, TYuDefinhYon" Duration* Designer Color
Collection,Trul)eOn|tkon°Oahrid °,Oakridge°an6WeathenGuora=HParefibemQ|msureinforced,|ominate6
asphalt roof shingles.
4.3 Berkshire* Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, VVeatherGuand° HP Hip & Ridge
Shingles,ProEdge Hip&Ridge Shingles and DuraRidge'"Hip&Ridge Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is o building code evaluation. NeitherTdnky(ERD nor Robert Nienineu P.E. are, in any vmay, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
E2 This Evaluation Report|ynot for use|nthe HVH2.
5.3 Fire Classification is not part of this Evaluation Report refer to current Approved Roofing Materials
Directory for fire ratings ofthis product.
Exterior Research and Design,I.I.C. Evaluation Report mavo4n.02.zems
ordfimte of Authaukaffonu950m pu067+RII
Revision 6:10815/u015
Pap aof 7
TRINITY ER®
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for
us in all wind zones up to Vasd=150 mph(Vuft= 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasd= 150 mph (Veit= 194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire'shingles require minimum five(5)nails per shingle.
WeatherGuard`HP shingles require minimum six(6)nails per shingle.
Devonshire'shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Feltunderlayment Deck Felt underhymem: Deck SO-odhered
Self-adhered Weatherlock?.
WeatherLocka underloymem
underlayment
Drip_, Drip edge Drip— Drip edge
edge edge
Nails locatedNess located
2'-3"from eave 2-3'fiomeave
Install first Self-sealing adhesive Sdtseal g adhesive
Starter Strip positioned along eave with6're removed 5tripPlus positionedlongcave
shingle with
vrith8'romoved
6"removed
Starter Strip shingle overhangs eaves and rakes 7i=rh" Starter Strip Plus overhangs eaves and rakes 1/4'-3/4'
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
CertlJhate afAuthorizatlon#9503 FL10674-R31
Revision 6:10/15/2015
Page 3 of 7
'J TRIN11Y,ERS
6.2.6 Minimum Nailing—Classic"&Supreme:
Normal Mansard or Area para Normal Mansard or Area pars
Wind Areas High Wind de- a,y Wind Areas High Wind deavanee y
Arae para vlantoe norm.lee Anas vfantos fuart.. Area pare vfamtos normstes Areas W tea!..rtes
4. z. .8: 4.
t
171.4
t
5"Exposure a 6/8'Exposure
Exposleldrr Expoeftf6n
6.2.7 Minimum Nailing—Berkshire*:
&eabnt strip saalant strip
is tka de"Aador to tka da ralfador
8Yi' t � 8 Yf 8 Yf' S'fti'' S 1t4'
L I
r
i
2" Asphaaroofing oamost
0anr¢ata de trctw da a#elf
6.2.8 Minimum Nailing—Devonshire':
Nails
Nails Ten 1'Spots of Asphalt Roof cement
Exterior Research and Design,LLC. Evatuation Report 037940.02.12-116
CeMficote ofAvikarftortan#9503 F110674-Rll
Revision 6:10/15/2015
Page 4 of 7
- ,' TRINIW!ERD
�j
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition
Duration*Designer Color Collection:
4 Nag Pattern 6 Nag
Esquama do 4 clavos Pattern
Esparne
su us ama W th db 6efavos
M BU
I-d-- ir Amid/
SLUMP
' E
War ExPMM ST Etimure
Naps
Wpuly.da-posfabn cbm R5pu1g.deW*skfdn SWEXPasure Naps W Uposure
SlApdo.&orposkft VaVos Ss pulp.do vVo0d6n
6.2.10 Minimum Nailing—TruDefinition"OakridgeO,OakridgeO:
4 Mail Pattern 6 Nail Pattern
EWow con 4 clavas Esquerna con 6 dams
14t 14— tr Ir
Ir
65/8"Exposure5 5/r Exposure Nags Naps E:VWWftde66j8Pdg. 56,W'EXPOSUM Sir Exposure
Clam Expos1ddndA6518ptdg SEXPWWh&5V8Pdi;.
6.2.11 Minimum Nailing—WeatherGuard"HP:
1111111211111111'itsltw View
X lilmom IhnPiOW11,11in
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge,Hip&Ridge with Sealant,WeatherGuardo HP
Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current
published instructions, using four(4) nails per shingle. Installation of DuraRldge T", Hip & Ridge Shingles
shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer
to Owens Corning published information on wind resistance and installation limitations,Including the use
of hand-sealing for wind warranties.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-116
cenVcate of Authorisation 89503 FL10674-R11
Revision 6:10/15/2015
Page 5 of 7
ti
�RINITER®
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
t— PtevMYnaYgna
Dlredfon A TopVlew SlaeNew
Naae�i4 ANails Nails
I �� Tap LaNnated
� 7
p I 4- Pima
14 A I
\\ A I $1
�%►E%pObtlraLA
�I
i
�I�
6.3.4 Minimum Nailing—Hip&Ridge with Sealant:
em Fig.2-High Wind Fastening Pattern
rim Shingle--r K Nails
nd Discard
Excess 21. 2"
1„ 1,.
Sealant --�
Stripa 12"
"Fastening 55/e" 5"Exposure
Distance
12"
6.3.5 Minimum Nailing—WeatherGuard" HP Hip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A wraungwlnxibn ma �4 Tapvavi
Do
A
Nulls
Nails Naps
7. z..
ja
Fr[powm
S" Erposula
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6
CerWicvte oJAuthorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 6 of 7
9. I'---JTRINITYIIERD
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard .---11"=
Wind Direction Sealait1 Strip P tt*:. g
. "" 6-Exposure 1` I f'{ �'� �•1'
* 1ftE Sealant
Fasten Ph- 6"Exposure
CovorExpNod
Fasteners with
Roof Cement (•--12"
6.3.7 Minimum Nailing--DuraRidgeT"Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens
Corning published installation Instructions for their minimum requirements.
x__ Praraii�WindtJi►otdm Vate�plwan
Qiraimdornimntodiaane li. visvtuperiar {`1N
Di►acdorl dddo�oo pradorniiunta
Ck
a 2 - i Onvmto,tinq SdtaNtx'-- • tkw
Mill
�"t► y (y
f
ir i
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall Indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC--QUA9625;(414)248-6409;karen.buchmann@ul.com
END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116
certifimte of Mthorttotton#9503 FL10674-PAI
Revision 6:10/15/2015
Page 7 of 7