Loading...
HomeMy WebLinkAboutProduct Approval 61612016 Florida&nldinn Code Ordine Florida Departmentif BQS Home I Log m User Reghn tian I Hot Topic I Submit SmI.,ge I Stats&Fads Iublicatic. I FBC Staff I BOS Site Map I Lima Seanch Businesi,?,U) -°- SER� U �'Professnal 0Public Regulation Product Approval Menu>Product or Application Search>Application List>Application Detail -a_• FL# FL10674-R11 Application Type Revision Code Version 2014 Application Status Approved Comments Archived f.1 Product Manufacturer Owens Corning Address/Phone/Email One Owens Coming Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@!Dwenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com hi Quality Assurance Representative JUIV Address/Phone/Email PEPfhi St. Lucie TTf,,,qG County, FL Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich, PE �_✓.✓.. Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R11 COI 2015 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code httpsJifloridabtfildingorgJpr/pr a O.aspx?param=wGE1/XQwtDgIBNbEY51J%2boQT%2b6w7ahReglCQ8LIcR6ixEAQdgbcUj3osQ°/p3d%3d 112 66/1016 Florida Buildng Cade Ondine Product Approval Method Method 1 Option D Date Submitted 10/15/2015 Date Validated 10/19/2015 Date Pending FBC Approval 10/20/2015 Date Approved 12/15/2015 Date Revised 04/18/2016 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab, 5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FI 10674 R11 II 2015 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R11.Ddf Impact Resistant-N/A Verified By: Robert 1. M. Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other.Refer to ER,Section S. Evaluation Reports .FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT SHINGLES FL10674-R11.pdf Created by Independent Third Party:Yes Baclk Next Conrad Us::1940 North Monme Street.Tallahassee FL 32399 Phone:856.487-1824 The State of Florida is an AA/ri0 employer.Couvrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida larv,email addresses are public records.If you do riot want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.InsWad,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must pmvhle the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 4S5,F.S.,please dick hemi. Product Approval Accepts: sccuritv.%u:ritics htips:/Moridabuildi%org/pr/pr app�M.aspC?param=wGEVXQwtDgiBNbEY5V%2boQT%2b6w7ahReg1CQ&xR6ixEAOd&Uj3osQ%3d%3d 2/2 --`----- r' EXTERIOR RESEARCH&DESIGN, LLC. { � :. Cer�cate ofAuthorization#9503 � � .1 � ER® 353 CHRISTIAOXFORD,STR ,CT 06478 I 0 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R6 One Owens Coming Parkway FL10674-R11 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 6: 10/15/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 51h Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning P g Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation_changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. .ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: `sort:�yrrvn,�rr �� �+'-... Thefacscniesealappearingvrasauthorized byRobert Nieminen, Robert J.M.Nieminen P.E. s -ti; c 'i;rrr `'iQ ,a` P.E.on 20/15/7015.This does not serve az an electronically signed t'✓�JJ/Nrgrf Nal Florida Registration No.59166,Florida DCA ANE1983 daotmerrG sgned,sealed hardmpies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinityJERD is not owned,operated or controlled by any company manufacturing or distributing.products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product- 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. �JTRINITYJERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Coming Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06WO263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34808 02/18/2012 UL LLC(TST9628) Physicals.&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireT"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition DurationDuration Premium Cool, TruDefinition' Duration' Designer Color Collection TruDefinition'Oakridgn,Oakridge and WeatherGuard'HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuardo HP Hip & Ridge Shingles,ProEdge Hip&Ridge Shingles and DuraRidgel Hip &Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are,,in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116 CertiTicvte ofAuthariration#9503 FL10674-R11 Revision 6:10/15/2015 Page 2 of 7 \J TRINrry i ER® 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM.D3161,Class F and/or ASTM D7158, Class H,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(Vnit= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd= 150 mph (V„It= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Coming published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 611320-3. 6. INSTALLATION: 6.1 Underiayment: 6.1.1 Underlayment shall be acceptable to•Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation.of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: ➢ Berkshire®shingles require minimum five(5)nails per shingle. WeatherGuard*HP shingles require minimum six(6)nails per shingle. ➢ Devonshire' shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Coming published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck Fe[vndertayment Deck Sdfadhered Weatheslm" Self-adhered undedaymem WeatherLocV underlaymenY Drip edge Drip— edge Drip edge edge Q g Na Nails located 2"-r lasted T-3'from save 2"-3"from eave Install first Self-sealing adhesiveSxilsearrog adhesive Starter Strip positioned along eave [m�®r�Starter Strip I'M positioned along eave shingle with \ vrith6"rcmaved 6"removed Starter Strip shingle overhangs eaves and rakes'!i-'/i' Star[erStrip Mrs overhangs eaves and rakes 1/41-3W Exterior Research and Design,I.M. Evaluation Report 037940.02.12-116 Certificate oJAuthadzotion#9503 FL10674-R11 Revision 6:10/15/2015 Page 3 of 7 TRINITY j ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area para Normal Mansard or Area para Wind Areas High Wind desvenes y yyind Areas High Wind desvanes y Area para vientos normades Areas vientos fuertes Area para vfentos normales Areas vientos fuertes fA) r 9" 2- ti; 2' �� '929 �� z• r r 99" 99" a 5"Exposure 5 51ti"Exposure Expoaioion Eriposicibn 6.2.7 Minimum Nailing—Berkshire®: Seabnt slip Seahrt strip La tira de seem to tira de 5dk-&r ,�— ®� '� • t--► •—e Nit•i---------D• 94 3 a t---')e 8 Vi" 9V 9 Vf 8Yt f 8 Yt' 8 pit 8 Yt° 8 11;rr - t Asphalt woofing cement Ceoxofo de rerho de agOo 6.2.8 Minimum Nailing—DevonshireTM': i–k- L 4 Nails r r r e• e• r r r r t r Sue Us Ten 1"Spots of Asphalt Roof Cement Exterior Research and Design,Ut Evaluation Report 037940;0232-R6 Certificate ofAuthorizotlon#9503 FL10674-R11 Revision 6:10/15/2015 Page 4 of 7 TRIM 'ER® 6.2.9- Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinitionm Duration Designer Color Collection: 4 Nail Mom 6 Nag Wen he n nswcf�� Espawdo4 davos Pattern amandtopueuto e. Esipema Ybrs-.rda eer5as Su rea EastaiogaieawidtBi da 6davos a;oahpda ertfa et Adl�dB daFDS.�Ir2Na�' • • • 7reaSmet4ad>ybpvfe —1 s�riac�lraore. SureNai°� \ SurRfk31P � �• P$1RrAr� � ffi$M0 arp�AN ` areaxi�h _ TC T! _ RRdde t' \ Rra• SurRkaiP LE • r y 5V Exposure Flogs SS"15tim re 65/pulp.de expasfcbvn Cbvos 5%prig.de expask2n 535"Exposure PJais 5%Exporse 5'A ptdg.de a po"a Clavas 5'.5 pufg.de exposfd6n 6:2.10 Minimum Nailing—TruDefinition Oakridge®,Oakridge®: 4 Nail Pattem 6 Nail Pattem Esquema con 4 clavas Esguema con 6 shwas r r r r rr—� 5518"Exposure nags5 578"ExposuaeNaas Exposie da de 6518 prlg. Cfavos Egan d6a de 5518pdS 5 57"8Eapmie Cbz 5 578"Exposme Expadcfdn de 5518prtlg ExpaskOw de 5618pufg. 6.2.11 Minimum Nailing—WeatherGuard® HP: y■ �� � 'Png1s ids View s :' :•;s• 3P.wii9� 6.3 Hip&Ridge Shingles: m 6.3.1 Installation'of Berkshire Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,WeatherGuard HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4) nails per shingle. Installation of Dura Ridge'"' Hip & Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6 CeAftmte of Authorization#9503 FL10674-R11 Revision 6:10/15/2015 Page 5 of 7 \4 TRIM Y I ER® 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—BerkshireO Hip&Ridge and High Ridge: Fig.7 4 F19.2 E— Dicectt¢p1d a D�-vevmn A YOPYIew Sideviea Hats p.. i Bites fiats 4 9- r TOPLaI T Piece 4 I I I I I j I 1 `y d ♦ • cl ®• —rI of e =I VI I 1 I I 1 I 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: ern Fig.2'- Nigh Wind Fast6ning Pattern R �l1S�. rim Shingle D! 2 7B 28►. EX StInp T s • ���8 B F4S`te,®DM4, VARP "Expo mIJl�E Distance - 12 ar. 6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.d Fig.C Hip&Ridge Shingle Fastening 4 4 X%zl gL1L�tl TopVkvr �-Otnstbn p A tial9s 4 4 A i i Raps bans p I I r 4 7 V I I I T 1° A I I P 1 I I I �• t.. s1 aPomre Exterior Research and Design,LLC. Evaluation Reoort 037940.02.12-116 Certificate of Authorization#9503 FL10674-Rll Revision 6:10/15/2015 Page 6 of 7 TRINITY{ERD 6.3.6. Minimum Nailing-ProEdge Hip.&Ridge Shingles: Prevailing Standard X11•—. Wind Direction Fastening � Exposure sure ScStrip Pattem� 6° Exposure 1'~I I"� IaI lY2" 12° 1 fI Sealant Fastenh°7'J,• , } 7 6°Eapasars Cover Exposed 1- FasteM,%vith Raaf Cemm 6.3.7 Minimum Nailing—DuraRidge"°Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Ibm�r3nglYari llise=um Top view `t—tl"sragi®adrsnecaxesgh�rvnt I- VVM®�mupev�{or 1'I QirnaScs�dul riae�pradosniear+tm N 2 Na" ® QL'JEfgM Cma' SNseldid° s Claw Itai6------- toua —t i' ' b $ a a° dlo` 8 I' 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.71/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on,which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: ULLLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116 CerbTicate of Authorizadon#9503 FL10674-R11 Revision 6:10/15/2015 Page 7 of 7