HomeMy WebLinkAboutProduct Approval Florida Building Code Online + �� i � ��`�F� V,�>L• Page 1 of 4
'J JUN 16 � n �:�
r�r ,Kn3;i 2011 i r P.
Honda�£FafITYiev' BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Stall i BCIS Site Map i Links Search
Business,-')
Professional '�� n Product Approval
USER:Public User
REgulation
Product Aooroval Menu>Product or application Search>Application List>Application Detail
,Irk.o rci _ FL# FL8228-R7
QTc:-*.•a£' y`,^.�Y�w`Ri.-e:,�
Application Type Affirmation
Code Version 2014
Application Status Approved ��
Comments
Archived ❑
Product Manufacturer Masonite International
Address/Phone/Email 1955 Powis Road
West Chicago,IL 60185
(800)663-3667
sschreiber@masonite.com
Authorized Signature Steve Schreiber
sschreiber@masonite.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute
Referenced Standard and Year(of Standard) fitandard Year
ASTM E1886 2002
ASTM E1996 2002
ASTM E330 2002
TAS 202 1994
r�
Equivalence of Product Standards
Certified By
�I affirm that there are no changes in the new Florida
Building Code which affect my product(s)and my product(s)
are in compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity OYes 0 N ON/A
Product Approval Method Method 1 Option A
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX QwtDquftCwaMPtp3 T... 6/14/2016
Florida Building Code Online Page 2 of 4
Date Submitted 04/29/2015
Date Validated 04/29/2015
Date Pending FBC Approval
Date Approved 05/04/2015
Summary of Products
FL# Model,Number or Name 4escription
8228.1 Fiberglass Side-Hinged Door Unit 6'-8"Opaque I/S and O/S Single Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.01.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure:+85.0/-85.0 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0160Dx.odf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Insti to
Zone,and where pressure requirements as determined by Created by Independent Third Party:
ASCE 7,does not exceed the design pressures listed.3'-0"x Evaluation Reports
6-8"max nominal size. Hurricane protective system L8228 R7 AE 504A. f
required in HVHZ,but not required in the Wind Borne Debris Bated by Independent Third Part s
Region.See DWG-MA-FLO160-07 for additional information.
8228.2 Fiberglass Side-Hinged Door Unit 8'-0"Opaque I/S and O/S Single Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.02.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure: +70.0/-70.0 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0161Dx.pdf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements as determined by Created by Independent Third Party:
ASCE 7,does not exceed the design pressures listed.3'-0"x Evaluation Reports
8'-0"max nominal size. Hurricane protective system FL8228 R7 AE 503A.odf
required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party:Yes
Region.See DWG-MA-FLO161-07 for additional information.
8228.3 Fiberglass Side-Hinged Door Unit 6'-8"Opaque Inswing Single or Double Door w/or w/o
Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.0l.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure:+50.5/-50.5Installation Instructions
Other:Evaluated for use in locations adhering to the FL8228 R7 II FL0160Dx.pdf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements as determined by Created by Independent Third Party:
ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports
x V-8"max nominal size. Hurricane protective system FL8228 R7 AE 502A.odf
required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party:Yes
Region.See DWG-MA-FLO160-07 for additional information.
8228.4 Fiberglass Side-Hinged Door Unit 6'-8"Opaque Outswing Single or Double Door w/or w/o
Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.01.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure: +55.0/-50.5 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0160Dx.odf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements as determined by Created by Independent Third Party:
ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports
x 6'-8"max nominal size. Hurricane protective system FL8228 R7 AE 502A.odf
required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party:Yes
Region.See DWG-MA-FLO160-07 for additional information.
8228.5 Fiberglass Side-Hinged Door Unit 8'-0"Opaque Inswing Single or Double Door w/or w/o
Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.02.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure: +50.5/-50.5 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0161Dx.odf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements as determined by Created by Independent Third Party:
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquftCwaMPtp3 T... 6/14/2016
Florida Building Code Online Page 3 of 4
ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports
x 8'-0"max nominal size. Hurricane protective system FL8228 R7 AE 501A.Ddf
required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party: Yes
Region.See DWG-MA-FLO161-07 for additional information.
8228.6 Fiberglass Side-Hinged Door Unit 8'-0"Opaque Outswing Single or Double Door w/or w/o
Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.02.Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure:+55.0/-50.5 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0161Dx.Ddf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements as determined by Created by Independent Third Party:
ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports
x 8'-0"max nominal size.Hurricane protective system FL8228 R7 AE 501A.Ddf
required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party:Yes
Region.See DWG-MA-FLO161-07 for additional information.
8228.7 Fiberglass Side-Hinged Door Unit 6'-8"Glazed Inswing Single or Double Door w/or w/o
Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.03.Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 12/31/2020
Design Pressure: +52.0/-52.0 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0162Dx.Ddf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements as determined by Created by Independent Third Party:
ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports
x 6'-8"max nominal size. Hurricane protective system FL8228 R7 AE 502A.Ddf
required in HVHZ and the Wind Borne Debris Region.See Created by Independent Third Party:Yes
DWG-MA-FLO162-07 for additional information.
8228.8 Fiberglass Side-Hinged Door Unit 6-8"Glazed Outswing Single or Double Door w/or w/o
Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.03.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 12/31/2020
Design Pressure: +55.0/-55.0 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0162Dx.pdf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements as determined by Created by Independent Third Party:
ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports
x 6'-8"max nominal size. Hurricane protective system FL8228 R7 AE 502A.Ddf
required in HVHZ and the Wind Borne Debris Region.See Created by Independent Third Party:Yes
DWG-MA-FLO162-07 for additional information.
8228.9 Fiberglass Side-Hinged Door Unit 8'-0"Glazed Inswing Single or Double Door w/or w/o
Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.04.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 12/31/2020
Design Pressure: +40.0/-45.0 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0163Dx.oddf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements as determined by Created by Independent Third Party:
ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports
x 8'-0"max nominal size. Hurricane protective system FL8228 R7 AE 501A.Ddf
required in HVHZ and the Wind Borne Debris Region.See Created by Independent Third Party: Yes
DWG-MA-FLO163-07 for additional information.
8228.10 Fiberglass Side-Hinged Door Unit 8'-0"Glazed Outswing Single or Double Door w/or w/o
Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL8228 R7 C CAC NI006900.04.Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 12/31/2020
Design Pressure: +43.0/-47.0 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0163Dx.Ddf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute
Zone,and where pressure requirements as determined by Created by Independent Third Party:
ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports
x 8'-0"max nominal size. Hurricane protective system FL8228 R7 AE 501A.odf
required in HVHZ and the Wind Borne Debris Region.See Created by Independent Third Party:Yes
DWG-MA-FLO163-07 for additional information.
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtD quftCwaMPtp 3 T... 6/14/2016
Florida Building Code Online Page 4 of 4
8228.11 Fiberglass Side-Hinged Door Unit 6'-8"Impact Glazed Inswing Single or Double Door w/or
w/o Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL8228 R7 C CAC NI006900.05.Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure:+52.0/-52.0 Installation Instructions
Other:Evaluated for use in locations adhering to the FL8228 R7 II FL0162Dx.Ddf
Florida Building Code not including the High Velocity Verified By: National Accreditation&Management Institute
Hurricane Zone,and where pressure requirements as Created by Independent Third Party:
determined by ASCE 7 do not exceed the design pressures Evaluation Reports
listed. 12'-0"x 6'-8"max nominal size.See DWG-MA- FL8228 R7 AE 502A.Ddf
FLO162-07 for additional information. Created by Independent Third Party: Yes
8228.12 Fiberglass Side-Hinged Door Unit 6'-8"Impact Glazed Outswing Single or Double Door w/or
w/o Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL8228 R7 C CAC NI006900.05.Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure:+55.0/-55.0 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0162Dx.Ddf
Florida Building Code not including the High Velocity Verified By: National Accreditation&Management Institute
Hurricane Zone,and where pressure requirements as Created by Independent Third Party:
determined by ASCE 7 do not exceed the design pressures Evaluation Reports
listed. 12'-0"x 6-8"max nominal size.See DWG-MA- FL8228 R7 AE 502A.Ddf
FLO162-07 for additional information. Created by Independent Third Party:Yes
8228.13 Fiberglass Side-Hinged Door Unit 8'-0"Impact Glazed Inswing Single or Double Door w/or
w/o Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL8228 R7 C CAC NI006900.06.Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure: +40.0/-45.0 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0163Dx.odf
Florida Building Code not including the High Velocity Verified By: National Accreditation&Management Institute
Hurricane Zone,and where pressure requirements as Created by Independent Third Party:
determined by ASCE 7 do not exceed the design pressures Evaluation Reports
listed. 12'-0"x 8'-0"max nominal size.See DWG-MA- FL8228 R7 AE 501A.Ddf
FLO163-07 for additional information. Created by Independent Third Party: Yes
8228.14 Fiberglass Side-Hinged Door Unit 8'-0"Impact Glazed Outswing Single or Double Door w/or
w/o Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL8228 R7 C CAC NI006900.06.0f
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 12/31/2020
Design Pressure: +43.0/-47.0 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0163Dx.pdf
Florida Building Code not including the High Velocity Verified By: National Accreditation&Management Institute
Hurricane Zone,and where pressure requirements as Created by Independent Third Party:
determined by ASCE 7 do not exceed the design pressures Evaluation Reports
listed. 12'-0"x 8'-0"max nominal size.See DWG-MA- FL8228 R7 AE 501A.0f
FLO163-07 for additional information. Created by Independent Third Party:Yes
Badt Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Cooyriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If
they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
a] ® aCtEck M
scLurihaurnucs
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquftCwaMPtp3T... 6/14/2016
�/ DO
� 149'MAX.OVERALL FR4ME WIDTH
/ CL: DO
cjonG�e^ o 0 0
SIDE-HINGED FIBERGLASS DOOR UNIT 21.MAX 36.375„MAX. Q CO
D.L.O. PANEL WIDTH J
6'-8"GLAZED DOUBLE DOOR WITH/WITHOUT SIDELITES VIIASTRAGAL FRAME WIDTH ci�
v,
GENERAL NOTES O
I. EVALUATED FOR USE IN LOCATIONS ADHERING TOLD
THE FLORIDA BUILDING CODE AND WHERE PRESSURE 0 U
DESIGN LOADS AS DETERMINED N ASCE 7,MINIMUM
a
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, Z _
DOES NOT EXCEED THE DESIGN PRESSURES LISTED. L_u Lr)U
2. WIZEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE(HVHZ). ug Z
HURRICANE PROTECTNE SYSTEM(SHUTTERS)IS REQUIRED. _ O
3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, co LU
EXCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ), ¢O Y
HURRICANE PROTECTIVE SYSTEM 15 NOT REQUIRED ON .i
PANELS WITH IMPACT GLASS,BUT IS REQUIRED ON PANELS h O ® SW
WITH NON-IMPACT GLASS. e O n
4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84.
POLYSTYRENE CORE FLAME SPREAD INDEX OF 15 'S
AND SMOKE DEVELOPED INDEX OF 115 PER ASTM E84. 2� o
5. PLASTICS TESTING OF FIBERGLASS FACING: �
pal
TEST DESCRIPTION DESIGNATION RESULT $JI-
SELF IGNITION 1EMP ASTM 01929 752'F>650'F I m W
RATE OF BURNING ASTM 0635 0.56 IN MIN
SMOKE DEN59Y ASTM 02843 53.47. C-2
TENSILE STRENGTH- ASTM D638 3.2%DIFF $
5. PLASM TESTING OF UTE FRAME MATERIAL'
TEST DESCRIPTION DESIGNATION RESULT DOUBDOOR NR W/ID ITS n
SELF IGNITION TEMP ASTM D1929 740'F>650'F
RATE OF BURNING ASTM D535 0.77 IN/MIN T, fItlflb HAAs 3 3 3 3}
SMOKE DENSITY ASTM D2843 13.4% CBSTi:L N)c NIT 00
TENSILE STRENGTH' ASTM D638 -7.50%DIFF
•COMPARATIVE TENSILE STRENGTH AFTER WEATHERING. 9/ A zO to
4500 HOURS XENON AN METHOD t Z Z
7. IMPACT GLAZING LAMINATE MIAMI DADE BCCO NOA 09-0127.13. a
V w
4
Barco
UaUO 0
J� O
QULW2� to
rjNZd
D�S� lY
�OOOW
�NNO1Q
SINGLE ODOR TIN R DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGIF DOOR UNIT 51N. DDDR INIT W/10 IT`; DOUBLE DOOR UNIT W/SIDELITEa
WITH SIDELITf WITH SfDIELIT o U m a z
WHERE WATER INFILTRATION PERFORMANCE IS wte 7/5 07
TABLE OF CONTENTS DESIGN PRESSURE RATING REQUIRED TO BE 15%OF DESIGN PRESSURE q
SHEEP DESCRIPTION CONFIG MAX WIDTH INSWING I OUTSWING INSWING OUTSWINC O ITSWING•
% 37.5 +52.0 -52.0 +55.0 -55.0 +t9.0 -19.0 +40.0 -40.0 +55.0 -55.0 owc.rx: SANS
1 TYPICAL ELEVATIONS&GENERAL NOTES X% 74 +52.0 -52.0 +55. -55.0 +19.0 -19.0 +40.0 -40.0 +55.0 -55.0
2 JANCHORING LOCATIONS&DETAILS OX or XO 75 +52.0 -52.0 +55.0 -55.0 +19.0 -19.0 +40.0 -40.0 +55.0 -55.0 P1K IM:
S ANCHORING LOCATIONS&DETAILS O%O 1125 +52.0 -52.0 +55.0 -55.0 +19.0 -19.0 +40.0 -40.0 +55.0 -55.0 KURT B4LTHAZOR DR.wWc Ko.:
0%XO 149 +52.0 +55.0 FLORIDA P.E DWG-da-817162-07
•High Dam Threshold Design #56533
si,m 1 a 3
SEE DETAIL J. �6' OU Q
I I I I S. 6' —8 6'—�— _ O O
3•—I .D u Z 0-
SEE
SEE DETAIL ¢ W
'D'
r �
SEE DETAIL C SEE DETAIL
'C' — o- — 6 w — — ^C'
in
G 0-
6.6'
66P J�
m a
��
ole o
-I - J'
6" 6'
SEE DETAIL N 3.t0 I^r
.E. l .All(0111�fl y V31 y N m
N9. lJ7GeL -T�7 z FN
G
//8 x 2-1/2" Dalalln' olv,li. a w�
AL RETAINER BOLT HOLE goo ti
MUST BE DRILLED THROUGH a o z
#10 x 2" THE THRESHOLD & INTO THE �� ¢ c
#8 x 2-1/2""
DETAIL "'E"ASTRAGAL STRUCTURE DEEP ENOUGH ti z o
#10 x 5/8" FOR A 1.375' THROW
#5 x 2-1/2" //10 x 3/4" ATTACH ASTRAGAL RETAINER BOLT
STRIKE PLATE TO FRAME DETAIL "F"ASTRAGAL =0 0 o w
O f/10 x 5/8" JIO x 3/4" AS SHOWN. nflNma
• 0.13A•ANN+111G (�VWAQ
NATW INSERT
110 x 2" NAQ DOW 832FRAME / DOORO.osD•srlea #6 x 1-t/3'PHS
DETAIL "D" DETAIL "C"TYPICALDAZE: 1/5/07
DDW 973DDW W20.962N.T.S.
�_, 7.75' I1.04TDwG.W. SINS
1.375.T T T E--� 1NrFinaa
TYPICAL GLAZING DETAIL -1ND.:
INSWING THRESHOLD OUTSWING THRESHOLD HIGH DAM O/S THRESHOLD IMPACT RATED GLASS TYPICAL
GLASS DWG-MA-FLO163-07
sHm 2 a 3
SEE DETAIL 3. 6" I —6• cr N
3' 6' I 3• I 3• U C)ED
I--6' 6'—I I I I I I 16' 6-j I I I o O J
6' e m Q C1
w
O-
� w a U
Z
n a SEE DETAIL - - a In U
y'D'SHT.2 Y Z Lf)
e ��
Lu
SEE DETAIL w w
'C'SHT.2
A A �
r
It 3. 3• I 3.
3. -I 3.6LLL 6" - 3• .. m ��
SEE DETAIL 6' 6' oiE
'F'SHT.2 6'- o
ATTACHMENT DETAIL woo.,
1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, '3x^'3"^m
SIGNED AND SEALED BY LUIS R. LOMAS, PE ?
(FLORIDA 062514) WITH THE LOWEST (LEAST) 0
wUO
z
FASTENER RATING FROM THE DIFFERENT FASTENERS
BEING CONSIDERED FOR USE. JAMB, HEAD, AND LLw
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE o
010 WOOD SCREWS OR 3/16" TAPCONS. A PHYSICAL d agoO z
SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR
LOCATION. TAPCON EDGE DISTANCE MIN 2-5/8". HARDWARE SCHEDULE �.0, w
2. MULLIONS TO BE 2-1/2" X 4-3/8" STRUCTURAL GRADE 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND
FJ PINE ON CONTINUOUS HEAD AND SILL UNITS. BACK TO SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED ^o
BACK JAMB UNITS JOINED WITH 1" X 1/2" LONG AT 5-1/2" CENTERLINE. �o w
CORRUGATED FASTENERS LOCATED 3" FROM EACH END 2. 4" X 4" FULL MORTISE BUTT HINGES.
AND MAXIMUM 7" O.C. OR 010 X 2" FLAT HEAD WOOD
SCREWS LOCATED 6" FROM EACH END AND MAXIMUM
12" O.C. 4
3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM 1.50' 1.25 * o U m a Z
ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT MIN —5 MIN —DMAX1
AX
OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE - SHIM > SHIM /AbBaIIbNWB wtE: 1/5/07
MINIMUM EMBEDMENT OF 1-1/4". Ce�m%., IJtaeb4�-2i-i[ scar N.T.S.
CL—I I- CL- I- „" ���
4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO �' p a „I„„ or �: Sw5
TRANSFER LOADS TO STRUCTURE. '�'� �`•'' cNK.er:
5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS. 0R01""G N0i
TYPICAL WOOD BUCK TYPICAL MASONRY oWG-w-n0I62-o7
ANCHOR INSTALLATION ANCHOR INSTALLATION
srtn 3 ar 3