Loading...
HomeMy WebLinkAboutProduct Approval (2)Florida Building Code Online http : //w ww. floridab ui l ding. org/pr/pr_app_dtl. aspx?param=wGE V X... Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Testing Lab Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By IKO Industries, Ltd 40 Hansen Road South Brampton, NON -US L6W 3H4 (708)496-2800 Ext 200 rmetzOO1@tampabay.rr.com Robert Metz rmetzOO1@tampabay.rr.com Bob Metz REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 (727) 776-5261 rmetzOO1@tampabay.rr.com Don Shaw IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 (717) 579-6706 don.shaw@iko.com Roofing Underlayments Test Report PRI Construction Materials Technologies, LLC Keystone Certifications, Inc. 06/26/2025 Zachary R. Priest, P.E. VValidation Checklist - Hardcopy Received 1 of 2 3/1/2016 1:26 PM BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications ; FBC Staff ; BCIS Site Ma Business1 _ Professional ttProduct �*r USER: Public User equiaton, ` Product Approval Menu > Product or Aoolication Search > Aoolication List > Application Detail FL # FL15529-R1 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Testing Lab Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By IKO Industries, Ltd 40 Hansen Road South Brampton, NON -US L6W 3H4 (708)496-2800 Ext 200 rmetzOO1@tampabay.rr.com Robert Metz rmetzOO1@tampabay.rr.com Bob Metz REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 (727) 776-5261 rmetzOO1@tampabay.rr.com Don Shaw IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 (717) 579-6706 don.shaw@iko.com Roofing Underlayments Test Report PRI Construction Materials Technologies, LLC Keystone Certifications, Inc. 06/26/2025 Zachary R. Priest, P.E. VValidation Checklist - Hardcopy Received 1 of 2 3/1/2016 1:26 PM Florida Building Code Online Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products http://www.floridabuildinc,.org/pr/pr app_ dtl.aspx?param=wGEVX... FL15529 R1 COI FL12838 R2 COI PRI CMT Cert of Ind FL15529 R1 COI FM - Certificate of Independence 3-25-2C Standard D1970 Method 1 Option B 06/29/2015 07/14/2015 07/23/2015 10/16/2015 FL # I Model, Number or Name I Description 15529.1 StormShield Standard Ice andI #7910033 Water Protector Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Year 2009 Installation Instructions FL15529 R1 II SShieldIW0806 Application 2012.pdf Verified By: PRI Construction Materials Tech Test Reports FL15529 R1 TR IKO-081-02-01 Report AS StormShield Standard Ice and Water Protect PRI.pd FL15529 R1 TR IKO-143-02-01 FBC 2014 FL15529.pdf Back Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: $i Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records req electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487. Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wi they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. Ii supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if yo Chapter 455, F.S., please click herr. Product Approva I Accepts. ® Ek secu ritv.,-, .;. 2 of 3/1/2016 1:26 PM CONSTRUCTION MATERIALS TECHNOLOGIES Brad Grzybowski Managing Director July 9, 2015 Dear Sir/Madam, PRI -CMT tested several products for IKO Industries and subsequently issued Laboratory Test Reports. These reports have been utilized to support FL15529. This letter serves to establish compliance of legacy test reports to FBC 2014. FL15529 — StormShield Standard Ice and Water Protector Product Specification • Applicable product specification: ASTM D1970 • FBC 2014 referenced standard year: ASTM D1970-09 • Test Report: PRI Project/Report Number IKO-081-02-01 states compliance to ASTM D1970-08. • Action: Establish equivalency between ASTM D1970-08 and ASTM D1970-09. • Conclusion: Compliance to FBC 2014 established. Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Signed: Signed: Brad Grzybo*ki Duc T N uyen Managing Director Florida Regist6fed Professional Engineer P.E. Number: 65034 Date: July 9, 2015 Date: July 9, 2015 I KO -143-02-01 PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materiaistesting@pricmt.com WebSite: hfp://www.pricmt.com APPLYING IKO'S STORMSHIELD ICE & WATER PROTECTOR Caution • Read all instructions before proceeding with application. • Membrane must always be covered by shingles or other roofing materials. It must not be left exposed to the weather. • This product is a vapour retardant. Space under roof deck must be properly ventilated to avoid moisture condensation. • In cool temperatures membrane should be tacked in place with mechanical fastenings. • Installation is not recommended when air and substrate surface temperatures are less than 5°C (40°F) APPLICATION DIRECTIONS Surface Preparation • The roof deck must be clean, smooth, dry and free of sharp protrusions. • Metal and masonry surfaces must be primed. Installation 1. Cut the membrane into 3 m to 4.5 m (10 ft. to 15 ft.) lengths. 2. Unroll and align with the lower edge of roof. Tack top edge with four equally -spaced temporary fasteners. 3. Lift the lower half and remove the lower release film, exposing the adhesive surface. 4. Carefully reposition the membrane down onto the deck and press firmly in place. Avoid wrinkles. Remove temporary fasteners. 5. Fold top half down and remove release film. 6. Carefully reposition the membrane up onto the deck and press firmly in place. Avoid wrinkles. • If two courses are required, the top course should overlap the selvage tape on the lower course by 75 mm (3"). • End laps must be at least 15 cm (6") and rolled to ensure adhesion and should be located at least 61 cm (24°) from those in the previous course. • Apply each course carefully. • Best suited for low sloped roof areas. Cover entire area with StormShield Standard Ice and Water Protector, lapped as outlined above, and then shingle as per normal shingle exposures. Valleys and Ridges • Cut the membrane into 1.2 m to 1.8 m (4 ft. to 6 ft.) lengths. In the valley, start at the low point and work upwards, overlapping each sheet at least 15 cm (6"). Peel off the release film and centre the sheet over the valley or ridge. Drape and press in place working from the centre outward toward the edges. • Membranes must not be left exposed in an open valley. Ice Dam Protection • Membrane must be applied to reach above the highest expected level of ice dams, and at least 61 cm (24") up the roof from the vertical projection of the interior surface of the outside wall. Drip Edge • Drip edges must be located under the membrane at the eaves, and over the membrane at rake edges. Note Do not remove selvage tape. Storage • Store rolls in their carton until application. Store inside or under cover not over 40°C (104°F) SShield]W 08-06 4. SShieldlW 08-06