Loading...
HomeMy WebLinkAboutProduct Approval 102016 Florida Building Code Online jig T. ®r� —' I; BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search Busines , r ei��1'. _3 JUN ? 79" W Product Approval Professional USER:PublicUsser FILE Product Anoroval Menu>Product or Application Search>Application List>Application Detail _ FL# FL10674-R41 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Coming Address/Phone/Email One Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Coming PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory "t Ing es F Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL10674 R11 COI 2015 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D http://Mmfloridabuilding.org/pr/pr app o.aspx?pararrFwGEVXQvADgtBNbEY5V%2boQT°/p2b6w7ahReglCQ8ucR6i)EAOdgtAJj3osQ`/`3d`/pad 1/2 1/812016 Florida Building Code Online Date Submitted 10/15/2015 Date Validated 10/19/2015 Date Pending FBC Approval 10/20/2015 Date Approved 12/15/2015 Summary ofproducts_---I FL# i Model,Number or Name Description 10674.1 I Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles i Shingles and Starters I 1 Limits of Use Installation Instructions i Approved for use in HVHZ:NO FL10674 Rll If 2015 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-Rll.ndf Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE- 59166 Design Pressure:N/A Created by Independent Third Party: Yes j Other:Refer to ER,Section 5. I Evaluation Reports I FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT I !SHINGLES FL10674-Rll.odf Created by Independent Third Party: Yes Contact Us::1940 North Monroe Street.Tallahassee Fl 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: E Z__ ®h sccurih-%:i i;uk http://voAfw.floridabuilding.org/pr/pr app Od.asplC?parafrt=wGEVXQvADgtBNbEY5Va/a2boQTa/o2b6w7ahReglCQ8ucR6i)EAOdgbdJj3osQ`/o3d%3d 212 6si3 i u�`p E R D ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category., Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R90S.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Enti Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration®, TruDefinitione Duration', Duration' Premium Cool, TruDefinitione Duration' Designer Color Collection,Tru Definition'Oakridge",Oakridge and WeatherGuard®HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard HP Hip & Ridge Shingles,ProEdge Hip &Ridge Shingles and DuraRidge'"Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 Certificate of Authorization#9503 FL10674-RSI Revision 6:10/15/2015 Page 2 of 7 R D 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(V.1,=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph (V„It= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 611320-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard'HP shingles require minimum six(6)nails per shingle. ➢ Devonshirerm shingles require minimum six(6)nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlavnrent Deck Feltunderhyment %; Deck SaE�dhered WeatherLockt Ti. SElladhered undedayment !� �YeatherLock= ?�. (:. gtlfiErlayntent Drip edge Drip_ Drip edge Drip— edge " :. edge Nalslocated -Nails located --T-3"from cave V-X"froin gave Install first Self-sealing adhesive Sd!cealing adhesive Starters,si, rositiuneilalunrcave hste�firstStartarStripPlus pos"rtonedalong cave shingler,it�r I J svdh6'removed ---c G'rerttoverl \ r r Starter Strip Plus overhangs eaves and rakes 1/41-3W Starter Strip shingle overhangs eaves and rakes "'—,a' Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 Certificate of Authorization#9503 FL10674-R11 Revision 6:10/15/2015 Page 3 of 7 4NIT ER 6.2.6 Minimum Nailing—Classic'&Supreme: Normal Mansard or Arae pare Normal Mansard or Area para Wind Areas High Wind desvanes y Wind Areas High Wind desvanes y Area para vientos normales Areas vientos fuertes Area para vientos normales Areas vientos fuertes t" IA► 1,, rt., z•Z f6 �z" t°� 1° iAl 1° �1• z IB► rz• 1" •—t1• 1Y 1Z7 —121 5"Exposure 6 9/8•Exposure Exposicidn Exposici6n 6.2.7 Minimum Nailing—Berkshire®: Soatard strip Sealant strip La tira de selkdbr La lira da sellador ill--D t----► • l--- 0 •4 • 0 t P 0 4---------i• • ->94 ;;• vt 9 IT R vt" } R V/' R y!' R'17' S YT r 1 - •{tee 2" Asphah rooting minent cemento de Who ire WOO 6.2.8 Minimum Nailing—Devonshire": —�— -`- Nails - _ - I Nails Ten 1"Spots of Asphalt Roof Cement Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 certificate ofAuthorization#9503 FL10674-R31 Revision 6:10/15/2015 Page 4 of 7 JyRI iia 9 ) '"_R`'.` 0 6.2.9 Minimum Nailing — Duration®, TruDefinition° Duration, Duration® Premium Cool & TruDefinition 0 Duration Designer Color Collection: e 4 Nail Pattern 6 Nail .n d�.•n Sucna Esquema de4clavos Pattern _za 1o,ctora=:.. Esquema +•`.mr ,Av F�=S SuRNallIfastening ar vAlth de6tlavos 3^.35kP.aEnd2i( Area dedavosSureNaiP • • • ra3si aaa"rhrrr'- -1 voscr�_trs:r:a. �r �rva,a�ln \ -rt�wn�n —1iLL LZ N..f� • •y • 54'a'Exposure fags 5+a'Erposure r .nn,patg.de exposidbr? Cfavos 5;;pufg.de exposfclon 54<'•Expr.,,ure Nail. 5"ro"Exprsurn 151A pufg.de expos,-bin tlavos 6:;puAg.de exnosfdorr 6.2.10 Minimum Nailing—TruDefinition•Oakridge®,Oakridge®: 4 Nail Pattern 5 Nail Pattern Esquema con 4 tlavos Esquema con 6 tlavos 1- V t' t IF- r<• —>I l� tr—il l 5516"ExposureNails 5 518 Expoaure Nag, Expos iciarde5518pufg. Clavos Exposfcd6nde5518pafg. 5518"Exposure Clavus 5518"Exposure Expm1don de 5518pulg. Exposhron de 5518Pula. 6.2.11 Minimum Nailing—WeatherGuard®HP: 1• 1Side View Stl►Peb hHWW Hr— Y 7 =J►{ •:Ms's ;a•► Fitanw7Fatwa�r Ndl Ci•v�•a 1a fisc�i!lFeirin 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire'Hip and Ridge Shingles,High Ridge,Hip&Ridge with Sealant,WeatherGuard®HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidgel Hip & Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 Certiftwte of Authorization#9503 FL10674-R11 Revision 6:10/15/2015 Page 5 of 7 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: i Fig.1 Fig.2 �— P+evdIm9lMnU n; ^§edion :i"� _ �:�o', Top>hw+ SiUeViea bail" --y Y ` •�� �•.� I Nat" Nal" t IT Tap Lana atW 1 2"�'—} v " IExposure li ,2., 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: em Fig. 2 - High Wind Fastening Pattem (4 Nails) rim Shingle— and Discard Excess —Sealant Strip . T l2" ' Fastening 5 5 Exp®sum Distance 12 6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A Y TOPVtav Prevaping YiiaU i:;:� �—Dlrectbn P` flails`--------)qq 1 .✓� .�,,o�. I ( I balls palls I t r 1i4* I -KIII 0 I I d Y Exposura Y Y Y Y —� Eaposurc �2�\ ` Exterior Research and Design,I.L.C. Evaluation Report 037940.02.12-R6 Certificate of Aathori:atfon#9503 FL10674-R11 Revision 6:10/15/2015 Page 6 of 7 - - �3.6 Minimum Nailing'PmEdgeHip&Ridge Shingles: 7revaillint; Standard 411ind Di Fastening Sealant Fasten 71,V 6"ExposuCre Caiier Exposed Fasteners with XRoof Cement 6.3.7 Minimum Nailing—DumRidgelHip&RNge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. PrQ,-ai!nEN*AndDir Top Vic- Vi.suptricr 1-1.* 2 Its' 7' LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein' 72 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in F8C Table 1SO7.2J.1/R9D5.Z'6.1' 0' Bu/Lo/mG PERMIT REQUIREMENTS: Aarequired bythe Building Official orAuthority Having Jurisdiction inorder toproperly evaluate the installation of this product. 9' MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY AssummN«E ENTITY: Vt.LLC—QUAg635;(414)Z48'6409;__ ' ' - END OFEVAWATION REpORT' Exterior Research and Design,I.I.C. Evaluation Report om79wumm.z2-ns ru�an�n�� u����xv�u��x�n Revision 6:10/15/2015 Page 7car