HomeMy WebLinkAboutWINDOW/DOOR INSTALLATION RESIDENTIAL (3) .pz �� �-v.''� „k �'�._::r-� ..�,"% ..� "•�- ���^ ,: ;.,'�;�"�t& ., ,��-.�,,xX` Grp -� -:,., ,.t c
tq
7
lig
Y
r
s
rS.
8
p
-
j(
L
M .
3 L•, � {j _ �'{� ...,,,tet jj
IT
fill
r
"� •m V .r 3 -...mow.«.. ` �� `*u •' �; {
pawn
o
}
t ,
V
..
- r777'-'
+sma
`Florida Building Code Online Page 1 of 5
r
BCIS Home } Log In ? User Registration Hot Topics i Submit Surcharge i Stats&Facts Publications FBC Staff BCIS Site Map Links 'i. Search
Businesy
Professit,e(A`�lA�_ USER: cUserAppa�
USER:Public User
Regulation
Product Approval Menu>Product or Application Search>Application List>Application Detail
asx FL# FL157 � '
Hi%4`3 „a �sawk
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Trinity Glass International
Address/Phone/Email 33615 1st Way S
Federal Way,WA 98003
(253) 875-7300
andrewn@trinityglass.com
Authorized Signature Vivian Wright
rickw@rwbldgconsuitants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative COPY
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
® Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2016
Validated By Ryan J. King,P.E.
0 Validation Checklist- Hardcopy Received
Certificate of Independence FL15255 R1 COI CERTIFICATE of INDEPENDENCE.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1929 1996
ASTM D2843 1999
ASTM D635 2003
ASTM G155 2004
TAS 201, 202, 203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL15255 R1 Eouiv Eauivalencv Of Standards.odf
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI Q... 6/28/2016
'Florida Building Code Online Page 2 of 5
Product Approval Method Method 1 Option D
Date Submitted 04/30/2015
Date Validated 05/01/2015
Date Pending FBC Approval 05/09/2015
Date Approved 06/23/2015
Date Revised 12/11/2015
Summary of Products
Go to Page f d AL1 Page 1/2
FL# Model, Number or Name Description
15255.1 a. Fiberglass Door 6'8 Single Opaque"Impact" Fiberglass Door-Outswing
Configuration(X)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst'15255.1.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.1 for Design Pressure Ratings,any FL15255 R1 AE Eval 15255.1.pdf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.2 b. Fiberglass Door 6'8 Single Opaque"Impact" Fiberglass Door with"Impact"
Sidelite or Sidelites-Outswing Continuous Head and Sill
Configurations(OX or XO; OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.2.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.2 for Design Pressure Ratings,any FL15255 R1 AE Eval 15255.2.pdf
additional use limitations,installation instructions and Created by Independent Third Parry:Yes
product particulars.
15255.3 c.Fiberglass Door 6'8 Single Opaque"Impact"Fiberglass Door with"Impact"
Sidelite or Sidelites-Outswing Configurations(OX or XO;
OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.3.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.3 for Design Pressure Ratings,any FL15255 R1 AE Eval 15255.3.odf
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15255.4 d. Fiberglass Door 6'8 Double Opaque"Impact"Fiberglass Door with or without
"Impact"Sidelites-Outswing Configurations(XX; OXXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.4.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.4 for Design Pressure Ratings,any FL15255 R1 AE Eva[ 15255.4.pdf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.5 e.Fiberglass Door 68 Single Glazed"Impact"Fiberglass Door-Outswing
Configuration(X)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.5.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.5 for Design Pressure Ratings,any FL15255 R1 AE Eva[ 15255.5.pdf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.6 f. Fiberglass Door 6'8 Single Glazed"Impact"Fiberglass Door with"Impact"
Sidelite or Sidelites-Outswing Continuous Head and Sill
Configurations(OX or XO; OXO)
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI Q... 6/28/2016
'Florida Building Code Online Page 3 of 5
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.6.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See-INST 15255.6 for Design Pressure Ratings,any FL15255 R1 AE Eva[ 15255.6.pdf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.7 g. Fiberglass Door 6'8 Single Glazed"Impact"Fiberglass Door with"Impact"
Sidelite or Sidelites-Outswing Configurations(OX or XO;
OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.7.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15255.7 for Design Pressure Ratings,any FL15255 R1 AE Eval 15255.7.pdf
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15255.8 h.Fiberglass Door 6'8 Double Glazed"Impact"Fiberglass Door with or without
"Impact"Sidelites-Outswing Configurations(XX; OXXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.8.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15255.8 for Design Pressure Ratings,any FL15255 R1 AE Eval 15255.8.pdf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.9 i.Fiberglass Door 6'8 Single Opaque"Non-Impact"Fiberglass Door-
Outswing/Inswing Configuration(X)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.9.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15255.9 for Design Pressure Ratings,any FL15255 R1 AE Eval 15255.9.pdf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.10 j.Fiberglass Door 6'8 Single Opaque"Non-Impact"Fiberglass Door with"Non-
Impact"Sidelite or Sidelites-Outswing/Inswing
Continuous Head and Sill Configurations(OX or XO; OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.10.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.10 for Design Pressure Ratings, FL15255 RI AE Eval 15255.10.pdf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.11 k.Fiberglass Door 6'8 Single Opaque"Non-Impact" Fiberglass Door with"Non-
Impact"Sidelite or Sidelites-Outswing/Inswing
Configurations(OX or XO;OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.11.1)df
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.11 for Design Pressure Ratings, FL15255 R1 AE Eval 15255.11.odf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.12 I. Fiberglass Door 6'8 Double Opaque"Non-Impact"Fiberglass Door with or
without"Non-Impact"Sidel[tes-Outswing/Inswing
Configurations(XX; OXXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.12.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.12 for Design Pressure Ratings, FL15255 R1 AE Eval 15255.12.pdf
any additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI Q... 6/28/2016
Florida Building Code Online Page 4 of 5
15255.13 m.Fiberglass Door 6'8 Single Glazed"Non-Impact"Fiberglass Door with"Non-
Impact"Sidelite or Sidelites-Outswing/Inswing
Continuous Head and Sill Configurations(OX or XO; OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.13.1)df
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15255.13 for Design Pressure Ratings, FL15255 RI AE Eval 15255.13.pdf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.14 n.Fiberglass Door 6'8 Single Glazed"Non-Impact"Fiberglass Door with"Non-
Impact"Sidelite or Sidelites-Outswin g/Inswing
Continuous Head and Sill Configurations(OX or X0; OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.14.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15255.14 for Design Pressure Ratings, FL15255 R1 AE Eval 15255.14.pdf
any additional use limitations, installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.15 o. Fiberglass Door 6'8 Single Glazed"Non-Impact"Fiberglass Door with"Non-
Impact"Sidelite or Sidelites-Outswing/Inswing
Configurations(OX or XO;OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.15.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15255.15 for Design Pressure Ratings, FL15255 R1 AE Eva] 15255.15.odf
any additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15255.16 p. Fiberglass Door 6'8 Double Glazed"Non-Impact"Fiberglass Door with or
without"Non-Impact"Sidelites-Outswing/Inswing
Configurations(XX;OXXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.16.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15255.16 for Design Pressure Ratings, FL15255 R1 AE Eva] 15255.16.pdf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.17 q. Fiberglass Door 8'0 Single Opaque"Non-Impact"Fiberglass Door-
Outswing/Inswing Configuration(X)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.17.1)df
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.17 for Design Pressure Ratings, FL15255 R1 AE Eval 15255.17.pdf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.18 r. Fiberglass Door 8'0 Single Opaque"Non-Impact"Fiberglass Door with"Non-
Impact"Sidelite or Sidelites-Outswing/Inswing
Continuous Head and Sill Configurations(OX or XO; OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FLI5255 R1 II Inst 15255.18.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15255.18 for Design Pressure Ratings, FL15255 R1 AE Eval 15255.18.pdf
any additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15255.19 s.Fiberglass Door 8'0 Single Opaque"Non-Impact"Fiberglass Door with"Non-
Impact"Sidelite or Sidelites-Outswing/Inswing
Configurations(OX or XO; OXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 RI II Inst 15255.19.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI Q... 6/28/2016
`Florida Building Code Online Page 5 of 5
Design Pressure: N/A Evaluation Reports
Other:See INST 15255.19 for Design Pressure Ratings, FL15255 R1 AE Eval 15255.19.Ddf
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15255.20 t. Fiberglass Door 8'0"Double Opaque"Non-Impact"Fiberglass Door with or
without"Non-Impact"Sidelites-Outswing/Inswing
Configurations(XX; OXXO)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15255 R1 II Inst 15255.20.Ddf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15255.20 for Design Pressure Ratings, FL15255 RS AE Eval 15255.20.odf
any additional use limitations, installation instructions and Created by Independent Third Party:Yes
product particulars.
Go to Page Page 1/2
Back Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click bgrr.
Product Approval Accepts:
01 RW @`heck rim.
�6`C.Itt'I tyA1.T'1t if.'S"
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZ IQ... 6/28/2016
; 3
TRINITY GLASS '`x&• � % AC3I,
INTERNATIONAL �_ z �
37-V MAX.O.A. �' GJ: a n
FRAME WIDTH �i�� '•.........
J O 0 m
pf,�% o CID n i
U N••
v 9 C1 0Zd
9m�w
GLAZED FIBERGLASS DOOR a SOL,
LL
O
INSWING / OUTSWI G E 9?
o �a
( NON-IMPACT' z z
3 in �o
in z
GENERAL NOTES 0 z o �.
1• This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building w o z
Code(FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). w w X O "
m Ad
" 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base
material shall be beyond wall dressing or stucco. y
3. When used in the"HVHZ"this product is required to be protected with an impact resistant covering o w
that complies with Section 1626 of the FBC. ¢ a
iso � a a
4. When used In areas outside of the"HVHT'requiring wind borne debris protection this product is Y}
required to be protected with an impact resistant covering that complies with Section 1609.1.2 of the 'm
FBC.
G �
5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck la
masonry construction.
N
6, Site conditions that deviate fromthe details of this drawing require further engineering analysis.by a m
z
licensed engineer or registered architect. 0
7. Outswing configuration using threshold item 05 meet water infiltration requirements for"HVHT',
0
B. Inswing configurations and outswing configuration using threshold item#27 do not meet the water
Infiltration requirements for the"HVHT'and shall be installed only in non-habitable areas or at o
3 habitable locations protected by an overhang or canopy such that the angle between the edge of o
canopy or overhang to sill is less than 45 degrees.
c TABLE OF CONTENTS MaX DESIGN PRESSURE(PS� DESIGN PRESSURE(PSf) o o
8 TItAME JAN18 TYPE FLUSH GLA3Eb KRAAAE LIP LRE GLAZED FIJAME o
SHEET# DESCRIPTION o 0
1 Typical a evotlons,des gn pressures&generol notes DIMENSION POSRIVE NEGAT/VE POSffIVE NEGAT►V . -z o
s 2 Door panel dela is-Itush glazing - - - DATE: 2 2 z
z 3 Door panel details-Up fde gkmng WOOD +70.0 -70.0 +47.0 -47.0 SCAM N.T.S. D
4 Horizontal cross sections
5 Verfical'cross sections 37.50"x 81.88" PVC DWG.BY: JK m
6 Buck and frame anchoring +60.0 -60.0 +47.0 -47.0 GHIC BY: LFS 3
7 Components FIBERGLASS/COMP DRAWING NO.: It
BI Bill of materials FL-15255.13 0
SHEET 1 OF S N
a
a
G3 GI LOCKBLOCK PVC STILE CAP PVC COMPOSITE
DOOR SKIN
CAP
TOP RAIL
PVC STILE EXTERIOR
2.48" 1-5�—_I Ij
6
z Z
Cl!
o
Z 000
LVL STILE 0 z
0.10, INTERIOR SEE NOTE 2 LVL STILE 0.10, LVL RAIL 6 0 C4
0 -z
FOAM CORE
z.0 v
pal /"�1 HORIZONTAL CROSS SECTION -0 !3
Q-t 0 IL
6 'w
zn
25� daLL
DOOR SKIN
NOTES:
1!7'GLASS BITE Spacing for lite frame screws Is as follows:
o cLq
35.75"MAX. •
Top/Bottom:2-3147 from each comer and 3.0.
PANEL WIDTH HOT MELT SEALANT I"O-A.THKGLASS
equally spaced thereafter[4 total)
EXTERIOR LITE FRAME
21.00' 1/9-TEMPERED Sides:2-3/,f'from each comer and
GLASS equally spaced thereafter(8 total)
MAX.D.L.O.
AIR SPACE
En ON
(n
G3 G1 Ed
1/8"TEMPERED
GLASS Q.:v)
c )
#8 X I-I/z,PPH SMS t:Ej
ALUMINUM EXTERIOR INTERIOR
[SEE NOTE 1) BUTYL SPACER
INTERIOR LITE FRAME
GLAZING DETAIL ti C7 o
�E
(Gllur—shUte Frame I p I
M in
BYTE QO
I/Z'GLASS
HOT MELT SEALANT I"O.A.THK GLASS
EXTERIOR LITE FRAME
T
SEE NOTE I
I/8"TEMPERED GLASS
SEE
AL INU
BUTYL
C
4*S1A. B LUSMPA El
*-N111-A
DETAIL I AIR SPACE
c; 0
Z
Fn
1/8"TEMPERED GLASS w
#8 X I-]IT PPH SMS, ALUMINUM&BUTYL 12
I) SPACER SYSTEM
(SEE NOTE 1)
GLAZING AIL
C,,�GLAZING DETAIL. u
G3 _�"NG,Lit.
INTERIOR gl—�ah.g.ny Lite Frame z.
LVL RAIL
e15" DETAIL I z
.
m
PVC COMPO., z
BOTTOM RAIL E3
RBERGLASSLDOOR AIL
"i OR
FLUSH ...................
(40 -;wAH'Fh FLUSH GLAZING N DATE: 2/27/12
D
.............
.............
scum: N.T.S.
z ........
...........
DWG.BY.
< ..... ..... ................. JK
FIBERGLASS DOOR SK(N�MIN. .079"THK. ............
VERTICAL CROSS SECTION
IB r2
FOAM CORE MATERIAL POLYURETHANE cw-BY: LFS
KNOB: SIGNATURE SERIES OWING NO,
MAHOGANY LITE FRAME FLUSH LITE FRAME KWIKSEr DEADBOLT: SIGNATURE SERIES(980) FL—15255.13
ABS or PC/ASA ABS or PC/ASA -EEr M2 ., 8
61
PVC STILE EXTERIOR LOCK BLOCK PVC STILE CAP
CAP —0.32, DOOR SKIN 2.48' 1.58"
PVC TOP RAILko
_ �N39 z' * O1z�m
LVL RAIL o � ` o>a>nN_ri
G
LVo z
0.10,
FOAM CORE G2 SEE NOTE 1 o v z o zG o
INTERIORS u 9 m o a
0.31" 1 HORIZONTAL CROSS SECTION 1.51" DOOR SKIN M a a T
3
_ E ,z
35.7S'MAX. g as
PANEL WIDTH zo
tn
21.00"
MAX.D.L.O. a N
UP UTE FRAME
ABS or PC/ASA w a C
I/2"GLASS BYTE z ^ a
d3 HOTMELTSFALANT EXTERIOR INTERIOR o o
1"O.A.THK GLASS
o EXTERIOR LITE FRAME G2 0
f12
3 � 1/8"TEMPERED GLASS a a
_ ^o AIR SPACE m
io
1/WTEMPEREDGLASS ,eN
m
d X
COODErAlL
#8 X 1-1/2'PPH SMS ALUMINUM&BUTYL SEE NOTE I
SPACER SYSTEM(SEE NOTE 1)SEE INTERIOR UTE FRAME FOAM CORE o zo
1 G2 GLAZING DETAIL U)� UP LRE FRAME
AB.S or PC/ASA
G
0
DETAIL 1
� z
e HARDWARE CHART P
MANUFACTURER MOpE4 LVL RAIL a o
a 2 KNOB SIGNATURE SERIES "z o
3 KWIKSEf —DA 2 27 12 i
DEADBOLT: SIGNATURE SERIES(980) PVC BOTTOM RAIL
z 40 FIBh tIES DOOR PANEL l�.Y,_ 5 N.T.S. 9
¢ with UP LBE GLAZING NOTE: DWG.sr: JK m
w 1.Spacing for lite frame screw is as follows: ^^`°'
FIBERGLASS DOOR SKIN:MIN.0.079"THK. Top and Bottom:7'from each comer and at centerline(3 total) CHK.on LFS 3
y DRAWING ND.:
F FOAM CORE MATERIAL POLYURETHANE Sides:Z'from each comer grid equally spaced thereafter(8 total) 3 VERTICAL CROSS SECTION FL-15255.13 0
SHEET 3 or 8
V
C
PAClients\Trinity PERMANENT\Florida Product Approvals\FL-15255\C-Drawings\FL-15255\FL-1525513-15,dwg,4.5
A
.V3
. z
v
a `
0 M W
V
� 0
?� N
g^ A �0
H
rn
a
�C) A�
a]
'-Y
Q Q
A
0
NA. AN
01 0
N N
A BE N
A W
o O m rT
A
X A o
X� A
qA
�n
n� N
�O w
tq 03
T N
n W
_ F A
rn
o m g °z
p h A
A N
y O a d.
N
f0 Q
f a A n
g�A
In
(O//yam♦
O
po e
D c J
0 v.
M a�
0
� `♦```V,••••�yGEN8�i.0�,ice.
�z
No.43409 _
f,7� N'o PRODUCT: Documents Pmparad By:TRINITY GLASS 1NT'L iP, Lyndon F. Schmidtitem 'P.E. No. 43409z 111111111%
IPART OR ASSEMBLY: /%�( BUILDING CONSULTANTS, INC.
iq03 02 15 UPDATEi05THED. (2014) FBCJK ' WP.O. Box 230, Valrieo, FL 33595
0° DATE BY HORIZONTAL CROSS SECTIONS phone No.: 813.659.9197
REVISIONS FBPE C.A. No. 9813
0 2131 Z R.W.BUILDING CONSULTANTS INa.
R:\Clients\Trinity PERMANENT\Florida Product Approvals\FL-15255\C-Drawings\FL-15255\FL-15255.13-16,dwg,5.5
m
m �n m
A m
no A
O¢
y v0 r)
n
0
(D H
_n CL m °q
70
m Q.
N
m O.1S'
w C'SINK
(TYP.) a ,
A
1-1/4'MIN.
EMB.(TYP.) °
p m
1-1/4MIN.
EMB.(TYP.)
N.
-n
V m
rn
1-1/4"MIN. w N a
EMB.(TYP.) O
> o m
C
No
CD
tr
n Q O ti!
�1 C3 -n °
° 7tm1 0 'n
7Op N
1-114 MIN. 1-1/4"MIN.
EMB.(TYP.) to EMB.(TYP.)
No.43409
.� PRODUCT: Document. Pr.parod By:
I o \ TRINfTY GLASS INTI P.E. No F 43409 Lyndon . fdt ////S,S,O�
.o, to r- •ZI v PART OR ASSEMBLY: /%�{p,//BUILDING CONSULTANTS, INC.
U :N ... 1 03 02 15 UPDATE TO 5TH ED. (2014 FHC JK t/vl/1/ P,O. eox 230, Valrico, FL 33595
NO DATE BY VERTICAL CROSS SEC71ONS VY phone No.: 813.659.9197
w
REVISIONS FBPE CA No, 9813
®201 2 R.W.BUILDING CONSULTANTS INC.
4.. SEE HINGE IT m \i�
e DETAIL I ��•�...............
.. ,
a
GJ+ of ro
r L 2X BUCK '��i�� '•-...... ��`
TYP.HEAD F 1X BUCK rrrrrr �� \\\\� o,o,m=
AND JAMBS u`q o a
TYP.HEAD — P E a z x o ci
AND JAMBS �+
2X BUCK 8 2X BUCK y m a a
OM
o
�•
E Z ^,
I
'Td v,
m DOOR
u FRAME 22
O ^O
Lu
SEE
MASONRY HINGE MASONRY
OPENING DETAIL 2 OPENING m �_
— — U
N Y�
TYP.SILL *�M
2X BUCK m
P o
a1X BUCK o
m a a
�m
23 4
LL BUCK ANCHORING HINGE JAMB FRAME ANCHORING STRIKE JAMB STRIKE PLATE DEWL yLn
CONCRETEANCHOR NOTES: Masonry construction W a
° 1.Concrete anchor locations at the comers may be adjusted to maintain the min.
edge distance to mortarjoints.
2. Concrete anchor locations noted as"MAX,ON CENTER"must be adjusted to
maintain the min.edge distance to mortor joints,additional concrete anchors
may be required to ensure the"MAX.ON CENTER"dimension are not exceeded.. J 2X BUCK J 2X BUCK � o
3 Concrete anchor table 3
a ANCHOR ANCHOR MIN.. M►N CLEARANCE MIN-CLEARANCE: H 1X BUCK H 1X BUCK i
w
TO MASONRY TO,ADJACENT • o
a' TYPE SIZE fMBEDMENi26 •` 26 n
2 EDGE.:...r........ANCHOk....
• • o a
z
ITW ® 1/4" 1-1/4" 2" N, 24 24 z
TAPCON a4Tc 2/27/12 i
€ ELCO ® 1/4" 1-1/4" 1" V, 18 18 SCALE 18
ULTRACON
a owc.BY: JK mm
2 ITW ® 3/16" 1-1/4" 3" 1.1/2" WK fry. LFS 3
TAPCON
WOOD SCREW INSTALLATION NOTES: HINGE DETAIL 1 HINGE DETAIL 2 °BMIN—NO.-
1.Maintain a minimum 518"edge distance,1"end distance,&1"o.c.spacing of FL-15255.13 "-
wood screws to prevent.the splitting of wood. sHEa 6 of 8 N
S
R:\ClientATrinity PERMANENT\Florida Product Approvals\FL-15255\C•Drawings\FL•15255\FL-15255.13-16.dwg,7.5
1.25'
m
?O
toN
CL K7
Gn
p -:' y"` 0.75' Av P
n 31
Z '..•S. N t7
—0.81"
IV
.i I
O
a I 1.37' N i
2
y:0'.
O 1•'' =t 3
7 a > =�4 €fit+l a
Po
F
1.34"
O
O
P
2
0
n
p
0 4
FF-
1-0.76-
oD
0 c
Co N
z
P ZO A
Z Gl
O m
SCHA
�o v• eF .T
No.43409
r..
PRODUCT: Document. Prepared By:
TRINITY GLASS INT'L Lyndon F. Schmidt moi,
z •,•
IV cn N P.E. No. 43409
$ Ln �— '—zj PART OR ASSEMBLY: BUILDING CONSULTANTS, INC.
I� fn N 1 03 02 IS UPDATE i0 57N ED. (2074) FSC JK COMPONENTS P.O. Box 230, VDIrIco, FL 33595
w NO DATE BY Phone No.: 813.659.9197
REVISIONS FBPE C.A. No. 9813
®2012 R.W.BUILDING CDNSULTANTG IND.
i
�: o t:
BILL OF MATERIALS n=�'�'
ITEM 4 DESCRIPTION MA1ERIAL z° � d of
A IXBUCK.SG> .055 WOOD
V.', :6j:z o w p
B 2X BUCK SG> 055 WOOD �i��'•.. ���\ �0roto
C 1/4 MAX SHIM SPACE
D 114'X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL Il'�I��+,� o M°O z°
MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI
�+I N•:
o a. U' 0 z°
E 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE \' h a t'o m c w
F 114'X 3-3/4"PFH ITW CONCRETE SCREW STEEL V a O v Q c
H 114'X 3-1/4"PFH ITW CONCRETE SCREW STEEL < m a o
� �
J 49 X 2-1/4"PFH WS STEEL E `o z°
L #8 X 2-1/2"PFH WS STEEL o° 3a
M 3/16"X3-1/4" PFH ITW CONCRETE SCREW STEEL
P 1/4'X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL _.
_1 JAMB(FINGER-JOINT PINE-SG>=0.42) WOOD
2 JAMB PVC ti
3 JAMB FIBERGLASS/COMP w
5 INSWING THRESHOLD ALUMINUM W/COMPOSITE SUBSTRATE ALUMINUM
Q
6 DOOR BOTTOM SWEEP PVC
m
8 #6 X 1-1/4PFH DRYWALL SCREW STEEL N
12 WEATHER STRIP QEBD650 Q-LON a m
18 3.9B3"X 4.0"HINGE MIN 0.098"THICK STEEL o
m 19 SILLKEY PC/ASA
22 DEADBOLT STRIKE PLATE STEEL a a
23 LATCH STRIKE PLATE STEEL m
24 #9 X 5/8"PFH WS STEEL
25 OUTSWING HIGH-DAM THRESHOLD ALUMINUM W/COMPOSITE SUBSTRATE ALUM./COMP.
N 26 #9 X 1.0"PFH WS STEEL
27 OUTSWING THRESHOLD ALUMINUM W/COMPOSITE SUBSTRATE ALUM./COMP, a
40` DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS $
64 #8 X 2"PFH WOOD SCREW STEEL a o
w
LD
V
O
0
Z
a W =
a
n 0 ?
B =
O O
^Z O
o GATE: 2/27/12 i
F SCA=E: N.T.S. 9
a z DWG.BY. JK 'm
c CHIC.BY: LFS 3
DRAWING NO.:
.E FL-15255.13 ro
SHEET $ OF S N
V
C