HomeMy WebLinkAboutSTORM SHUTTERS COMMERCIAL (3) BUIL DING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR MAWONEur__s & CLADDING (PIF-) FOR ASCE 7-10 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET BASIC WINO SPEED 170 mph RISK CATEGORY N BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS& COMMERC14L BUILDINGS(RETAIL, WHOLESALE) PEAK L-LESS THAN 7'-9' L-•GREATER OR EQUAL THAN 7'-9'AND L-•GREATER OR EQUAL THAN 12'-J' ROOF LESS THAN 12'-J' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE PoSBIVE NEGATIVE (h) IRTVArE ASO. ULTIMATE ASD. ULTIMATE ASO. ULTYATE ASO. ULTIMATE ASO. ULHMATE A.S.D. /NDICAIED DESIGN WIND PRESSURES * o'- 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 57.3 68.5 41.1 CORRESPOND TO THE MAXIMUM ENO 86.4 51.8 ZONE AND INTERIOR ZONE CONOITONS > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 AND FOR ALL ROOF >20'-25' 83.6 50.2 111.9 67.1 79.8 47.9 104.4 62.6 74.8 44.9 SLOPES 94.4 56.6 **L-STORM PANEL LENGTH, L50�60' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3 46.4 97,4 58.4 ACCORDION SHUTTER 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 8}.2 48.7 102.4 61.4 SHUN HEIGHT ENM OR�l 94.3 56.6 126.2 75.7 90.0 54.0 1177 70.6 84.4 50.6 106.5 63.9 *** PRODUCTS WHICH Blies A 97.3 58.4 130.3 78.2 92.9 557 121.5 72.9 87.2 52.J 109.9 65.9 MAUI-OADE COUNTY OR A STATE OF FLORIDA APPROVAL r _aUl�n/N_r._c PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS& CLADDING (P.S.FJ FOR ASCE 7-10 - PEAK ROOF HEIGHT GREATER THAN 60 FEET* BASIC WIND SPEED - 170 mph RISK CATEGORY Il BUILDINGS RESIDENTIAL,APARTMENT BUILDINGS& COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) ?S00f lft f S`G�S c PEAK L••LESS THAN 12-J' L-GREATER OR EQUAL THAN 12'-3' U) ROOF HEIGHT POSITIVE NEGATIVE POSITIVE NECA71VC (h) ULTIMATE I A.S.D. ULUYATE I A.S.D. ULTIMATE ASD. ULTIMATE i A.S.D. C -0 C= J J In >60'-70' 91.5 54.9 167.7 100.6 84.3 50.6 1 148.4 89.0 n. �e ,BUILDING SCHEMATIC >70'-80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 -y >80'-9a' 956 574 175.2 105.1 88.0 52.8 155.0 930 O >90'- 97.3 5 178.4 1 89.7 53.8 157.9 94.7 C zs=❑ > roD'- 120' 100.5 0.3 0.5 184.2 1 92.5 55.5 163.0 97.8 J C:� j44E4aiuii•�� > 120 - 140' 1032 61.9 189.2 1135 95.1 57.1 167.4 100.4 Kn _ 11(1 A rr > 140'- 160' 1056 63.4 193.6 116.2 97.3 58.4 171.3 102.8 -LI F, ti L,P�� ... ���✓L > 160'- 180' 107.8 64.7 197.6 118.6 99.3 59.6 174.9 104.9 •vGENSF•••':9 z 11 B 0. 65.9 201.3 120.8 101.1 60.7 176.1 106.9 _ 0'-250' 114 68.5 209.2 125.5 105.2 63.1 185.1 111. >20 �`, :' No.44167 - >250'-J00' 117.8 70.1 216.0 129.6 108.5 65.1 191.1 114.7 * * >300'-.750' 121.0 72.6 221.9 133.1 111.5 66.9 196.3 1178 STATE OF >400'-40500' 126.4 75.8 231.8 139.1 116.5 69.9 1 205.1 123.1 � .<�:•';A[ORIOP >45o'-500' 128.8 77J 236.7 141.7 8.6 71.2 208.9 1253 11This is Not A Master Drawing. .ss�onA�E�'�,�1� Valid Only For One Time Permifr NO I.)THIS CER77RM SIGNED AND SEALED WIND LOAD CHART,PREPARED BY THIS ENGINEER,&LSfD ON ASCE 7-10,FOR A BL-4C 1WN0 SPEED OF 170 MPH.,AND 2014(5th EDITION)FLORIDA BUILDING CODE-BROWARD,PALM BEACH, MARTIN,Sr.LUCIE&INDIAN RIVER COUNTIES APPUC49L.E RISK CATEGORY BUILDING&EXPOSURES IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPfC/RC PROJECT. ASCE 7-10/ WIND PRESSURE CHART AS SHOWN 2.)MIS WIND LOAD CHART MUST BE SIGNED,SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT STORM PANELS,ACCORDION&BAHAMA SHUTTERS soy SCALE J.)CONTRACTOR OR PERMIT HOLDER to BE RESPONSIBLE FOR THE SELECRON OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. RISK GT. lI SLOGS 06/1//15 WINO PRESSURES ARE ULTIMATE AND ASO.PRESSURES. MT[ 4.)THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS I L E CO 1 N e, WINQ PRESSURE CHART TBLIT TESTING&ENGINEERING COMPANY BASIC WIND SPEED- 170 mph 15-188 5.)DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE IND/CA7EO ON A SEPARATE DOCUMENT'PREPARED BY e7as nes,sew srLsv.sas,hAVUu Ov+xxs n agree EXPOSURE O,Kd-CBS ME CONTRACTOR OR PERMIT HOLDER(e.g.,SPREADSHEET,OPENING SCHEDULE/TAKE OFF SHEET,ETC.). DRAWING No EB-0006719 WALTER A. TLLT Jr.P.E. aA rr-m n u a - - FLORIDA Lic.1 44167 s miMrce a _ SHEET ] OF 1