Loading...
HomeMy WebLinkAboutWINDOW/DOOR INSTALLATION RESIDENTIAL (6) 7/29/2015 Florida Building Code Online pxg " iy-,—_• .1� - _�. _ _ _^ice::-.r=.� _ - .=.a�-- - -_ .t' �.� -_ _:� a p�,r..:�o•-i:- !_Err` ?=^ - - ir11-Y^... 1-7-iri'��i `yi c' _'u3 i~:P�iui'a,i i'7.•A'•rhf Y :,:5?�ie'c`:i.:'? -:;:,-'-.',c - 2'.'_T=`ry ...9: :: I ;s.. L=a��•-�=_w— I': '- �_nf!M4:2o/ -- _ _ _ _ _ _ __ -_ _ _:tic -• -- 7,-:+•- c �•3?r.:EI BCIS Home Log in-• User Reglstmtlen i Hot Topics Submit Surthar a Stats 6 Factr Publications-�F6C-Staff A-'BCIS`Site-Map.Y Links Search :p... Professiona I + 41 USES Public User i 1%Igul Ll(.)i s Anct Approval Menu>Product or Aoolintion Search>Anolicatlnn List>A r Ilcation notall _ ^} FL n FL15210-RS - Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440)969-9773 Ext 16 ric kw@rwbldgconsulta nts.com Authorized Signature Vivian Wright ric kw@nvbldgconsultants_com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastpminc.com Quality Assurance Representative Ron O'Connell Address/Phone/Err><atl 5200 W Century Blvd. Los Angeles, CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com Category Exterior Roors ~ Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report,from a Florida Registered Architect ora Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Nacre who developed the Lyndon F.Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan .long, P.E. •' Validation Checklist-Hardcopy Received Certificate of Independence FL15210 RS COI CERTIFICATE of INDEPENDENCE.odf Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 1998 ASTM D63B 2003 ASTM E1300 2OD4 ASTM E84 2005 ASTM G26 1995 G 155 2005 TAS 201, 202, 203 1994 Equivalence of Product Standards http://Horiclabuilding.orgiprlpr_app dt1.aspx?paranr-wGEVXQWDgv3y&MCJZlQRCFPquBgbCgp%2bzCgPjPW2002Tk"/`2fmoBUv�/`3d°/aid 1/4 7129/2015 Florida Building Code Online Certified By Florida Licensed Professiom/Engineer or Architect Sections from the Code .......... ... .........__-----_________ _ _ "mum;t Approval Method Method zOption o Date Submitted 04124/2015 Date Validated 04/26/2015 Date Pending FecApproval 04/29/2015 Date Approved 06/2312015 FIL Model,Number or Na me 1 Description 'a.SMOCIth/Wood Grain/White Wood G'B'Impact"Opaque Fiberglass Single Door- Inswing/Outswing(X Grain/Rustic/MaKogany Series 0 Configuration) Fiberglass Door Urnits of Use Installation Instructions Approved for use In HVHZ,Yes FLiS210 RS 11 Inst 15210.1,odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Created by Independent Third Party*Yes Impact Resistant:Yes Design Pressure:N/A Evaluation Reports ' ~^^-^'~~~—' ----for- --sign—P----Ratings,-�' FLIS 1.0 M AE} ;v�� ' aumtmnn|u=/m�amo,s. /n�a�tmn�sr�c,mnand vmuct c�a�muvmuepen�en, /��nanr ' �particulars._ '. _- ---------- Grain/White Wood .eo ^Opaque Fiberglass Single Door with Sidelite or xun nv Series o smelite - mswmmuvtsnino(Ox or XO; v^u-Configurations) Fiberglass Door 'u~x�"vu=° Installation InstrucApproved tions ' . / . m,"°em*vo�ws . Approved for use outsidenVHZ-*s Verified By. Lyndon F.SchmIdL,P.E.43409 ' Impact Resistant:Yes Created by ,es | Design pressure:N/A 'Evaluation Other.See INST 15210.2m,oesign Pressure additional use limitations, installation Instructions and product Created by Independent Third Party:Yes i 15210.3 1 c.Smooth/Wood Grain/White Wood 168"Irripact'Opaque Fiberglass Double Door with or without i Fiberglass Door Limits of Use 1 Installation Instructions I Approved for use In HVHZ:Yes FLIS210 R5 11 Inst 15210.3. Approved for use outside HVHZ:Yes Verified By., Lyndon F.Schmidt,P.E.43409 i Impact Resistant:Yes Created by Independent Third Pariy:Yes Design Pressure:N/A Evaluation Reports other:See INST 15210.3 for Design Pressure Ratings,any t FL15210 RS AE Eval.-15210.3-ndf additional use 11mit-ations, installation Instructions and product Z—reated by Independent Third Party:Yes i particulars. 115210.4 i d.Smooth/Wood Grain/White Wood 68"In-Epart"Glazed Fiberglass Single Door-Inswing/Outswing(X- i I Grain/Rustic/Mahogany Series 0 Configuration) I Fiberglass Door Limits Of Use Installation Instructions Approved for use In HVHZ.Yes FLIS2113 IRS IT Inst 1.5210.4. Approved for use outside HVHZ!Yes Verified By: Lyndon F.SChrridt, P.E.43409 Impact Resistant:Yes Created by Independent Third Patty:Yes Design Pressure:NIA Evaluation Reports Other*See INST 15210.4 for Design Pressure Ratings,any FI-15210 R5 AE Eval-IS210.4.p additional use limitations,Installation Instructions and product Created by Independent Third Party.Yes 210.5 e.Smooth/Wood Graln/White Wood 16'8"Impact"Glazed Fiberglass Single Door with Sidelite or Sidelites Grain/Rustic/Mahogany Series 0 Inswing/OutswIng (OX or XO; OXO-Configurations) 1 Fiberglass Door Limits of Use Installation Instructions Approved for use In 14VHZ.Yes FL15210 R5 11 Trist 15210.5.pdf Approved fbr use outside KVHZ:Yes i Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Othem See INST 15210.5 for Design Pressure Ratings, any I FLIS210 R.5 AE Eval 15210.5.pdf additional use Hiritations,installation Instructions and product Created by Independent Third Patty:Yes hup:I/Um/oauuk8no,mglpxpr_opp._OU.eapx?moan-Fv,GB0(Q\Ntoqv3yVmJZIOnoFPquBgboqvD/.obzCqAiPW20\k) aw 712212015 Florida Building Code Online 15210.6 f.Sm0DthJW0Dd Grain/White Wood i 68"Impact"Gazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites- Inswing/Outswing(XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 H Inst 15210.6.r)df Approved for use outside HVHZ:Yes i Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party.Yes Desl n Pressure:_N/ I I Evaluation-------- -qn Rep Other:See INST 15210.6 for Design Pressure Ratings,any 1 FL15210 R5 AE Eval 15210.-6.ndf additional use lirritatlons, Installation instructions and product Created by Independent Third Party:Yes particulars. 111210.7 g.Smooth/Wood Grain/White Wood BID'Impact"Glazed Fiberglass Single Door" Outswing(X- Grain/Rustic/Mahogany Series 0 1 Configuration) 1 Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 11 Inst 15210.7.f)df Approved for use outside HVHZ:Yes 1 Verified By: Lyndon F.Schmidt,P.E.43409 I Impact Resistant:Yes Created by Independent Third Party'.Yes Design Pressure:NIA i Evaluation Reports Other:See INST 15210.7 for Design Pressure Ratings,any FL15210 R5 AEEval15210.2jid . additional use limitations, installation Instructions and product I Created by Independent Third Party Yes particulars. 15210.6 h.Srraoth/Wood Grain/White Wood B'0"ImpactGlazed Fiberglass Single Door with Sidelite or Sidelites Grein/Rustic/Mahogany Series 0 Outswing(OX or XO;OXO-Configurations) I Fiberglass Door i Limits of Use Installation Instructions Approved for use in HVHZ:Yes i FL15210 R5 11 Inst 15210.8,pdf Approved for Use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See'INST 15210.8 for Design Pressure Ratings,any fLI5210 R5 AE Eval 15210.B.pcif additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15210.9 E. Smooth/Wood Grain/White Wood 810"impact"Gazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 'Sidelltes-Outswing(XX; OXXO-Configurations) Fiberglass Door Limits of Use installation Instructions FL152jo R5 11 Inst-1.5210.2,orif Approved for use In HVHZ-.Yes Approved for use outside HVHZ.-Yes s Verified By. Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other.See INST 15210.9 for Design Pressure Ratings,any ELIS210 R5 AE Eval 15210.9,r3df 1 additional use limitations, installation instructions and product 1 Created by Independent Third Party:Yes particulars. .......... 15210.10 j. Smooth/Wood Grain/White Wood 810"Impact"Opaque Fiberglass Single Door-Outswing(X- Grain/Rustic/Mahogany Series 0 Configuration) 1 Fiberglass Door Limits of Use i1ristallation Instructions Approved for use in HVHZ:YesL15210 R5 11 Inst 15210.10.pdf Approved for use outside HVHZ,Yes i Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant.Yes Created by Independent Third Party,Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.10 for Design Pressure Ratings,any i FL1S210 its AE Eval15210,10.od additional use limitations, installation Instructions and product Created by Independent Third Party:Yes particulars. 15210.11 k.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Siderite or Grain/Rustic/Mahogany Series 0 Sidelites-Outswing(OX or XO; OXO-Configurations) Fiberglass Door Limits of Use j Installation Instructions Approved for use in HVHZ:Yes FLIS21D RS 11 Inst 15210.11.i3d Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schrridt,P.E.43409 impact Resistant.,Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.11 for Design Pressure Ratings,any 1 FL15210 R5 AE Eval 152113.11.nd additional use limitations, Installation Instructions and product Created by Independent Third Party:Yes particulars. 15210.12 1,Smooth/Wood Grain/White Wood BID'Impact'Opaque Fiberglass Double Door with or without I Grain/Rustic/Mahogany Series 0 Sidelltes- Outswing(XX; OXXO- Configurations) Fiberglass Door rLimits of*Use Instructions Installation Instctions A;Epprovad for use in HVHZ:Yes FLJ5210 P-5 If Inst 15210.12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure,N/A Evaluation Reports Other:See INST 15210.12 for Design Pressure Ratings,any FL15210 R5 AE-Eva( 15210.12.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes htip://Horidabuilding.org/pripr—appjtl.aspx?paranT--v,GEVXQvADqv3y\MJZ10RCFPquBgbCqp%2bzCq.NPW2OvD2TW/`2fmQBUW%3d%3d 314 7/29/2015 Florida Building Code Online particulars. 15210.13 m. Smooth/Wood Grain/White Wood 810"Impact'Opaque Fiberglass Single Door with Surface Bolts- I Grain/Rustic/Mahogany Series O ;Outswing(X-Configuration) Fiberglass Door i -----�---------------- -— ._._._......_.... ! -_._...... Limits of Use Installation Instructions Approved for use in HVHZ:Yes { FL1S210 RS II Inst 15210.13.odf __._........ _ .-_ Approved for_use.outside HV.HZ:_Y.es.._.........._..__....__........ i.-.Verifled By:_Ly.ndon_F._Schmidt,._P.E.434pg, Impact Resistant,Yes Created by Independent Third Party:Yes I Design Pressure:N/A j Evaluation Reports Other.See INST 15210.13 for Design Pressure Ratings, any i FL15210 R5 AE Eval 15210.13.odf additional use limitations,installation instructions and product t Created by Independent Third Party:Yes particulars. i 152.10.14 n.Smooth/Wood Grain/White Wood j 810"Impact"Opaque Fiberglass Double Door with Surface Bolts on Grain/Rustic/Mahogany Series O ;Active Door panel-Outswing(XX- Configuration) i Fiberglass Door Limits f Use Installation instructions I Approved for use in HVHZ:Yes FL15210 RS It Inst 15210.14.odf j Approved for use outside HVHZ:Yes i Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports ; Other:See INST 15210.14 for Design Pressure Ratings, any FL15210 R5 AE Eval 15210.14.Ddf additional use limitations, installation Instructions and product i Created by Independent Third Party:Yes particulars. i 115210.15 I o.Smooth/Wood Grain/White Wood 810"Impact"Glazed Fiberglass Single Door utilizing the i Grain/Rustic/Mahogany Series 0 WINDSERT'" an operational window insert- Outswing(X- Fiberglass Door `Configuration) _. ... -.... . ......._...... _.__....._.............. - - _.._...__._.. ._.. — .............. Limits of Use i Installation Instructions Approved for use in HVHZ:Yes FLIS210 R5 11 Inst 15210.1.5.pdf Approved for use outside HVHZ:Yes Verified,By:.Lyndon F.Schmidt, P.E.43409 ; impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.15 for Design Pressure Ratings, any MS210 RS AE Eval 15210.15.pdf i additional use limitations, Installation instructions and product Created by Independent Third Party:Yes i particulars. ' 0 Canty ct Us;:3940 North Monroe Street.Tallahassgg FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Canvrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement;:Refund Statement Under Florida la,v,email addre53es are public records_If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F-S.must provide the Department with an email address if they have one.The erna0s provided may be used for official communication with the licensee.However email addresses are public record.If you do not vAsh to supply a personal address,please provide the Department with an email address whtch can be made available to the public.To determine If you arc a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: MFrscr occuritt'•se rx:r•':; lltp:/iflorid2builifing.orgtprlpr_app dtl.aspX?pararr>=wGEVXQvADgV3y%M{JZIQRCFPquBgbCgp%2bzCgAjPtn{20-.D2Tkl/o2fmOBUvP/o3da/aid 414 �� `� �Jl�D^��` ��0D8�l lD� ' . �~ ��� ~~ ,, Building Consultants, Inc. ` `` �� Coouu|�g�d2n�nc���3r��m������Nk�|ndum� -- Cnum%zmvnun�I-c3359x ,mm*o\zu39.o/o/ Florida Board"rrmaw""ms"wiW,=c"mnm/*orx"o`unz*iaoNo.vx/z IJ Product Category Sub Cateciory Manufacturer Product Name Swinging Plastpro,Inc. Smooth I Wood Grain I White Wood Grain Exterior Exterior Door 5200 W.Century Blvd. Rustic I Mahogany Doors Assemblies Los Angeles,CA 90045 Series 0 Fiberglass Door Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for Plastpro Inc.,based on Rule Chapter No.61 G20-3, Method I D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and isincompliance ViUhthe 5th Edition(2014)Florida Building Code structural requirements including the"HlqhVelocity Hurricane Zone^. 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3- When used inthe"HVHZ'this product complies with section 162Oof the Florida Building Code and does not require animpact resistant covofinq. 4. VVhanuaedinare0000tsideoythe"HVHZ"mquWingvNndbornedebhopmteoUon\hdspmductcomp\kesuiUnSeu8on1GOg.1.2o[tbe FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4osdefined\n ASTM E1Sg6and Section 16V3.1.2.2of the FBC. 5. For 2x stud framing construction,anchorling of these units shall be the same as that shown for 2xbuck masonry construction. 6. Site conditions that deviate from the details of drawing FL-15210.4 e4uinw further engineering analysis byalicensed engineer or �re�n�nada� t bibso 7' OutsvWngconfigurations meet water infiltration requirements fox"HVHZ!'. All other configurations dmnot meet the water infiltration requirements for the"HVHZ'and must be installed only in non-habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy oroverhang tosill isless than 45degrees. 8' See drawing FL-i521O.4for size and design pressure limitations. Supporting Documents: Testing,Laboratory Signed bV '' Test Report No. Test Standard 01390365 TAS a4&TAS 203�* les5,g�m���mLa�.Inc, Lyndonf.Schmidt,-- 05-25516776.0 ASTM osa5-su,saa-nu.1yo9-96&2o43'99 ETC Laboratories Joseph L.uuman.P.s. ASTM o26-sa ETC-06-255-17412.0 ASTM E84-oo ETC Laboratories Joseph L.Doldan.P.E. s7o-07a09'19303.0 ASTM o6asgo.aooua.1aao'ee&2843'99 ETC Laboratories Ben Meunier 2. Miami-Dade NOA Materials SaflempVoInterlayer(Eastman Chemical Company) 13'0114.05 Royal Mouldings(em.PVC) 3. No.FL-15210.4 RVxBuilding Consultants,Inc.(CA#9813) Lyndon,.Schmidt,,�� 4' '`'' . � '��` -Ined&Sealed bySic` Anchorling RW Bu8�ngCons�aNs.�o (CA#9813) w,ww/��"..""`,.= ASTM E1oouGlass Load Lyndon F.Schmidt,P.s 5' Lyndon ' � F.Suomidt,P.E. rLPENo.43*09 412412015 Sheet ImI ro 5200 W. CENTURY BLVD. 5 xe LOS ANGELES, CA 90045 .37.50FRAME'MA)(.ovERAL j•., wfoTH ••........c• Smooth / Wood Grain / White Wood Grain Rustic/Mahogany + J �l r`"'r't� a z LL e 9 z ado 5mow Series O Fiberglass Door r moa e INSWING/OUTSWING I1 °z r i rr o° as impacr GENERALNOTES \ n Ls product has been evaluated and is to comprrance with the 51h Edition 2014E Florida Building Code C structural requirements including 1he'High Velocity Hurricane Zone"(HVHZJ. � 0 z o M a oz 2. Product anchor shall be as listed and spaced os shown on details.Anchor embedment to base material A shot[be beyond wall dressing orstucco. 0 5 ?Ad 0 U WUj 6 3. When used In the"HVHT'this product complies with Section 1626 of the Florida Building Code and does not F a a 3re rrequire an Impact resistant covering. oI o O =t a a 4. When used in areas outside of the"HVHT'requiring wind borne debris protection this product complies with b a a o Section 1609.12 of the 2014 FBC and does not require an impact res'rstanl covering.This product meets C4 , missile level V and includes Wind Zone 4 as defined in ASTM E 1996 and Section'l609.1.2.2 of the FBC. `° m E 5. For 2x stud construction.anchoring of these units shall be the some as that shown for 2x buck masonry construction. �. 6. Site conditions that deviate from the details of this drawing require further engineering analysts by a licensed ; z w 0 x engineer or registered architect. Ej 7. Oulswing configurations meet water infiltration requkemenls for'HVHT'.All otherconfigurations do not meet the water infiltration requirements forlhe"HVHT'and must be installed only In non-habitable areas or of habitable locations protected by on overhang or canopy such that the angle between the edge of canopy or overhang to sill Is fess than 45 degrees. TA81E OF COMEMS CeeFhets2 SNEETd DESCRfP1fONI lypicolelevatlan,desf n ressures,8generalnotes D1MENS10lJ.2 Door panel dela is37.50" 3 Ute frame delols and glazing defals a 4` Horizontal cross section x +73.0 -75.0 oare02 16 125 Vedtcalcrosssecilans 82.00" scut: N.T.S.6 3 ointiockdetals 37.50" armm: JK7 3-pafntlackdetals X +75.0 -75.0 CHK.9Buckand frame anchoring 81.7 3"9 Components FL-15210,410 But of materialsor hardware and lite frame design pressu imitations n °r 10 a `d 0FF .7" Gi G2 _ TOP RAIL r aa• ExTERIOR 0.4" (cAMP.( .c.'�� ..•a•: �•-i• •�: - ice' z •„.�� oam�in INTERIOR CAP(PVC( CAP(PVC) N HINGE STILE(LVL( LATCH STILE{LVID .• a • E O 9Y m o HORIZONTAL CROSS SECTION ti n 5 q Gg a b :•a•• � .' c �t maa� o z. Etj -r• s •j. 35.ISDOOR :s NAADWARETi1>aLEo WIDTH MAX:DE6I.N `s MI(NUfAC1URER :' r:`;,%;.``."MODE[: ':2 :. 'ii.':.:' fRE53UAE S ay KWIKSEI KNOB: SIGNATURE SERIES *2 75 Gi a DEADBOLT: SIGNATURESERIES(4B0) a G2 ig $CHLAGE KNOB: 'f SERIES(PSI) o g DEADBOLT: -rSERM(660/62) 75 4 0l M PAMEX LEVER: Fin SERIFS }'� INTERIOR o J f� EXTERIOR a o DEADBOLL FD7S131IF5 �m a - HOPPE MULTI-POINT LOCK: 3-POINTTONGUE +50 Ell T WRF MULTI•POINTLOCK. TRIUNNIUM"30W'SERIES ±75 a Z � �Oi• w ek See sheets 6 and 7 formu8l•polnt lock detaRs. '.•• W N y SEE HARDWARE FIBERGLASS SKIN a 3 w TABLE (0,175'MIN.THK.) °'• o K FOAM CORE / 'T t SEE HARDWARE (POLYURETHANE- ✓ TABLE 1.4 PCF MIN.) �',/''xis'-•'`e•?''.i � —z n° BOTTOM RAIL }" ` anTL02j1& T2 a (COMP.) scxL N.T.S. c C cwc,et: JK m DD PANEL twc Of. LFS 4{) O 2 VERTICAL CROSS SECTION a# 2 oumiic uu: FL-15210.4 0 � MAk 0.A,FRAME HEIGHT 0 66.3S MAX.O.A.FRAME HEIGHT p HEIGHT Fr--- ci cn 90 in Tit No. -- - '--'' jr- PLASTPRO INC. P.r- 43409 F713ERGLAS!;DOOR PART OR ASSEMBLY: CONSULTANTS, INC, 41 NO DATE BY LITE FRAME 017A, REVISIONS 12— AND GI AZING VE AU Phone No.: 1313.059.9107 . . ' Mclientsttgasloto.Inc plip"NYENTV10"da(7alNtt Amma WL-15219 twtt2 fibe9tass-InpItt Qpmj-and GSamdtC-DrPwAxplft•25210(2014AFL-15220.1-6.dwg 4A A: ' A + A aAtr III t— ,A a 0 N ail 1 o � a A Nt —� Epy � \�y vu to A 3 bt N tst TtI A W l►,N X � m � � A M O7D pu g� y, a N ,tea ,. -----r let D , ' v O O O .Z1 i� i E! a T_ al V? A co 93 z D. 4� D r r ' � �/ `ttpll llltli2l f�1j.`rrr 43409 r ................. ........_....._.................... ................ ..... .._........................... .1........................................_...................../.z .. ........................ k e!r 'roy z Q PRODUCT: Doeument+pvxP-"81: •• „�� i r F Lyndon F. SChmtdt �i 'gOfODFr• 1�'� fA i x o PLAWRO INC. P.E No.43409 I FIBERGLASS coag Tulcustl o N PAR?0R A55EFiflLY, TSBUILDING CONSULTANTS.INC. VDAIE" UPDATE TO 5TH ED. 2014 fEC tfOR12tlNTAl.CRO55 SC'RONS P.O. Bo: 230. Valr(eo, FL 33595 (p 'I' i s BY Ru(Phane No.: 813.058.9197 REVISI NS FSPE CA No. 9813 �}2D 1 2 R.W.(it11CAiNa CAMAU�T+ttTd tnC. , A\t7fen61Ptasfprv,Inc PERMANENT\Florida Product Apprwals\FL•15230 NVNZ Fiberglass-Impact Opaque and Glaz4aC•Dmvwings\FL-15210(2014hh-15210.1.6 dwg,5a I e XI m a ca O o v • Y r) p�n Ln f Ln v s t a O z C'SINK — r. m {TYP.a \J EMB.CFYP m a 1-114't.ilN. m '� a , �0 ar M 3� >F a a0 m0 M � M en hS T-IMMIN. m D' p EM9,{TYP.J 0 , n �n� i •n a g enA xy to('� a IIIA , a V O q an. 1•1/4'MIN. Ld Ca Cd 0 `Txr' `aaaaa419Cf•fM�A����i ........ ......_.,._................................ ............... ... ... .. .... ..._ ....N.... 9CZ ... ..... .. PRODttCT: Wwmonts Pr.SwM1a 9y: .,.,L{�• u A Lyndon F. Sehmldt �11� r� P.E. No. 43409 �J •+I••••••• a PtASiPR4 INC. - trr QNAt- as # ratlttt N111aa 1� 1 F78ERG POOR o N y PART OR ASSEMBLY: r BUILDING CONSULTANTS, INC. to\kDAV UPDATE 711 5714 E0. 20)4 FBC JN r-'t/i! P.O. 8vk 230,Vaicicv, FL 33595 N gy VERnCA! CRASS SECTIONS lliitt// Phono No.: 813.859,9197 REVISION$ FSPE CA No. 9613 C m 4CI1 2 R.W.HCILw—OOrrn"UT..,im INC. Majant�.\pj=pna.Inc PSMtMENT\Fl.nda Product Apptovals1FLAS210 Mv"Z FWerqt4ss-ImpW Opaque and Gazc�C-Drawinqs\FL-15216(Z0I4}VL-lSZl0.1-s.dw%64 OVERALL HSGHT m HANDLE HEIGHT 0, rn G) rn ns 4.63" 3.6 T 0 az n 8,87' Q r; O 0 C= A 0 r) n am g, 43.49" No.4309 ................. .............. .. ...... QPRODUCT. Documanim Pmpo-d Dr. F1 4.tin F. E P.E. PLA57PRO INC, No. 43409 hmtdt FIBERGLASS DOOR PART OR Y` BUILS)INU CQNSULTAW�c. INC. FUC JK P.O. Box 230, VoIrlm FL 33595 --j UPE14TE TO STH ED. (2014) J—PGIMT TLOCK MAILS h3 U100ATE 8y Phan No.-813.659.9197 REVISIONS FBPE_CA No. 9813 B."o".0 C..SuLT—")... R.-AOicntslPlucipro.Inc PERMANE'M1Hoiida Product ApprmwlAFL-15710 HVHZ Fiberglass•Impaa DWPq and GIn1c11C-Draw4ngslFL-15210(20141WL-152101•Ldwg 7.4 P. T F CA 0 C 3 >r a N w X X m m n W >c � s Go 0 A >F m 0 l l�24.25' 23.0' 15.0' v•�ucE►i�••.A No.43409 ........ ............... .........._............ /i�rtl ............... .. . ... ............. ..._........ ...................... .......... .... ............. .. .. ... *. ... .. .. In y9 q Q PRODUCT• 0oeem�nta Pn 0r• ,� r x PLASTPRO Lyndon P. Schmidt �i •���•' �� to ro 2 FIBERGLASS DOOR P.E. He. 43409 PART OR ASSELIOLY: VTK HUILDING CONSULTANTS, INC. Io x cO 1 3 9/1 UPDATE TO 5TH ED, 2014 FBC JK r!L P.O. - 230, Vahrico. FL 33595 � a h1 NO DATE By 3—POINT LOCK DETAILS �1/ 13 Phone No.; 8F3.059.9197 R i510NS FHPE:GA No. 9613 2012 R.W.HIlILG1110 CGHn HLT�T,Tn Ir Ri. 1TYP'1 �. ����� t�s1,�: n fry = f� s J-ri n • O a ri ,mill 1 z t z d O d SEE HINGE L 2X BUCK tl a $"�•; d TYP.HEADa &JAMBS a DEfA1L PYP.) �, IX BUCK N Eo m _ _ ,ojUY 9011 MASONRY7 6 MASONRY &JB8D s 4+ m a a OPENING OPENINGCn ggo z R FRAME ti IJ a = 2X BUCK p z a z¢ .� 2X BUCK ppp�`nrLu o` Gt m _. O m o ' X ADA SILL o ONLYco c m H fA i BUCKANCHORING STRIKEJAMB FRAMEANCHORING HINGEJAMS w o o Mosonry conslfucllon x '_^ o � r'. CONCRETEANCHOIINOEFS: Lj 3 1.Concrete anch%locations at the comers may be adjusted to rralnfohE the mfn. 10 edge dlstonco fo morforjolnfs• 1XBUCKH a' 2.Concrefooncharfocolforumfedar MAX0NCENTErt•muffbeccWodfo 9 c mornloN the rrvr.edge dafance fo maMwfdnh.oddlflonalconaefe anchors 2X BUCK F c may be required to onnae fhe MAX.ON Cl3/W dimarulon ora not exceeded, 28 p Ix BUCK 11 IXBUCK N q o S 3 Conve r quired totue v' Mfr1 CLEARANCE. MINiIFARANCE n a ANCHOR ANCfLOR MIN _ � �$ 2X BUCK ,TYPE'; SRE'., EMBEDfjEM IOMASDNRP :.TOAQJACEM:_ 2X BUCK 58 11 2X BUCK z ........ .: :.:EDGE •....:; z U ze TAPCON` 114- 1.114- r 4-ffw IX BUCK M MTF-02/16/12 0 gg 2x BUCK 11 1 ELCOscat• N.T.S. ° ULTRACON 114' 1'11'1' 1' 4' 27 FI 1X BUCK ovm.an JK m V ro 3116' 1-114- r I.l1r OElAIL au.m3: LFS TaecON � HINGE In Wing DRAVNI"v NO.: c 1.WOODs�EWINSTAtunaNNOTE: LATCH 6DEADBOLTDEL4IL NGEDETAl1 FL-15210.4 `I 9 Malnfafn o mWmS/H' um edge d3tonco,fond Moncc.d Vo.c.spacingNL oof NGE'Dng a is ii woodsewsloprovenf the spUfing ofwood, sNEr 8 OF 10 0 O d ' Fkadua AppvWs%F1-15MD HVH tat-hpi Opque"d Gjat.AC Dmi.qskFL-j52ID(201ANFL-15210.1-64-9 SA 0 pO Q1 1.75 Ia. DAY 1z 0.15" O 0.93r 0.75" VP H0.434na .... .................... ........... PRODUCT.. Lyndon F. Schmidt 15 PLAISTFRO INC. PF- No. 434011 FIBERGLASS ODOR lfNittt PART OR ASSSA BUILDING CONSUMANTS. INC. L In P 0. Box 230.VaIrIca, FL 33595 :]W UPDATE TO SIN ED. (2014) FED JK PFBPE No.: 813.559.9197 REVISiDNS NO COMPONENTS YY QI I--R.W.au—ma,ca"u—T-ays I'm. BlU OF MATERIALS ,•g t om^ n Dg az ti IMM 4 DFSCRrP= MATERIAL 'N': *• 5 A IX BUCK SG>=0.55 WOOD �00 8 2X BUCK SG>=0.55 WOOD C I/4"MAX.SHIM SPACE •..... ' ��� :o m m D 1/4X 2-3/4"PFH ELCO OR[TW CONCRETE SCREW STEEL MASONRY-3.000 PSI MIN.CONCRETE CONFORMING TO ACI col nO •:Z E CONCRETE 30109 HOLLOW BLOCK CONFORMING TO ASTM C90 9 z o z u G 1/4"X3.3/4"PFH ELCOOR ITW CONCRETE SCREW STEEL o a z H 3/16"X 3.1/4"PFH ITW CONCRETE SCREW STEEL In r m a 1 1/4"X 1-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL L #8 X 2-1/Z'PFH WOOD SCREW STEELE z M #8 X 1-1/7'PFH WOOD SCREW STEEL o° d 1 POLY FIBER JAMB COMP./VINYL 2 FINGER JOINTED PINE FRAME WOOD 3 EXT.FRAME(ODL ALUM. 4 INT.FRAME(ODL) ALUM. o `� 5 R7-19 X 1-3/4"PPH SELF-DRILLING 5M5 51EEL F 6 #10 X 1.3/4"PPH WOOD SCREW STEEL o v, 0 7 WEATHERSTRIP FOAM 8 DOOR BOTTOM SWEEP VINYL g 9 4"X 4"BUTT HINGE STEEL a m v 11 '#9X3/4"PFH WOOD SCREW STEEL �I o 12 NON STRUCTURAL SEALANT SILICONE o c 13 STRUCTURALSIUCINE DOW 995( SILICONE a g 15 EXT.FRAME BY ROYAL MOULDINGS PVC s 16 INT.FRAME (BY ROYAL MOULDINGS) PVC m E 17 SCREW CAP (BY ROYAL MOULDINGS) PVC 22 3 POINT'TONGUE'MULTIPOINT LOCKSET(Mfg.BY HOPPE) STEEL F 23 MULTI-POINT STRIKE PLATE(TONGUESYSTEM) STEEL o 25 LATCH A14D DIADBOLT STRIKE PLATE(TONGUE SYSTEM) STEEL 27 LATCH STRIKE PLATE STEEL o 28 DEADSOLTSTRIKE PLATE(SECURITY) STEEL LA 29 ADATHRESHOLD ALUM 30 OUTSWING THRESHOLD ALUM/WOOD 31 OUTSWING THRESHOLD ALUM/WOOD 32 OUTSWING THRESHOLD ALUM/WOOD a 33 OUTSWING THRESHOLD ALUM/COMP e 34 OUTSWING THRESHOLD ALUM/WOOD 9 36 INSWING THRESHOLD ALUM/COMP 37 INSWING THRESHOLD ALUM/WOOD " o 3B INSWING THRESHOLD ALUM/COMP z " 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS DAM 02116112 55 "10 X 1-1/7'PFH SCREW STEEL sou N.T.S. 9 57 BACKING PLATE STEEL Irec.m: JK m 58 #6 X 7'PFH WS STEEL clot BY. LFS 3 g 60 MULTI-POINT STRIKE PLATE STEEL DRAM116II3ri 62LOCK ASSEMBLY STEEL FL-15210.4 0 ` 514EU 10 av 10 9 0 a