HomeMy WebLinkAboutNotice of Acceptance MIAM MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy
CertainTeed Corporation
1400 Union Meeting Road
Blue Bell,PA 19422
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Landmark,Landmark Pro,Landmark Premium,Landmark Impact Resistant,Landmark
Solaris,and Landmark Pro/Architectural 80
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA#12-1204.01 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 14-0828.04
CMIAMMADECOUNTY Expiration Date:02/28/17
Approval Date:02/12/15
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub-Category: Asphalt Shingles
Materials Dimensional
Deck Type: Wood
SCOPE
This renews CertainTeed Landmark, Landmark Pro, Landmark Premium, Landmark Impact Resistant and
Landmark Solaris Shingles as manufactured by CertainTeed Corporation described in Section 2 of this Notice of
Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Certainteed Landmark 13'/4" x 38 /4" TAS 110 A heavy weight,dimensional asphalt
Manufacturing shingle.
Locations#1,2,3,4,5,6,7,8,9
Certainteed Landmark Pro 13'/4' x 38'/4" TAS 110 A heavy weight,dimensional asphalt
Manufacturing shingle.
Locations#1,3,4,5,6,9
Certainteed Landmark Premium 13'/4' x 383/4" TAS 110 A heavy weight,dimensional asphalt
Manufacturing shingle.
Locations#1,3,4,5,6,8,9
Certainteed Landmark Impact 13'/4'x 383/4" TAS 110 A heavy weight,dimensional asphalt
Resistant shingle.
Manufacturing
Locations#1,7
Certainteed Landmark Solaris 13'/4'x 383/4" TAS 110 A heavy weight,dimensional asphalt
Manufacturing shingle.
Locations#1,8
Certainteed Landmark 13'/4'x 383/4" TAS 110 A heavy weight,dimensional asphalt
Pro/Architect 80 shingle.
Manufacturing
Locations#8
Accessory Shingles various proprietary Accessory shingles for hip,ridge and starter
strip applications.
NOA No.: 14-0828.04
MIAMFQADECOUNTY Expiration Date:02/28/17
Approval Date:02/12/15
Page 2 of 6
MANUFACTURING LOCATION(S):
1. Peachtree City,GA.
2. Ennis,TX.
3. Oxford,NC.
4. Shakopee,MN.
5. Avery(Milan),OH
6. Norwood,MA
7. Shreveport,LA.
8. Portland,OR.
9. Wilmington,CA.
EVIDENCE SUBMITTED:
Test Aeency Test Identifier Test Name ort Date
/Ren
Underwriters Laboratories,Inc. R684 UL 790 04/02/01
PRI Asphalt Technologies,Inc. PCTC-01-02-01 TAS 100 01/12/01
CTC-006-02-01 TAS 100 11/12/02
PRI Construction Materials Technologies CTC-092-02-01 TAS 100 02/23/12
CTC-091-02-01 TAS 100 02/21/12
CTC-090-02-01 TAS 100 09/02/11
CTC-087-02-01 TAS 100 07/07/11
CTC-086-02-01 TAS 100 07/07/11
CTC-101-02-01 TAS 100 10/05/11
CTC-102-02-01 TAS 100 10/05/11
CTC-109-02-01 TAS 100 01/18/12
CTC-106-02-01 TAS 100 11/02/11
CTC-105-02-01 TAS 100 10/31/11
CTC-089-02-01 TAS 100 07/18/11
CTC-088-02-01 TAS 100 07/18/11
CTC-213-02-01 TAS 100 05/20/14
CTC-212-02-01 TAS 100 05/21/14
CTC-207-02-01 TAS 100 05/20/14
CTC-206-02-01 TAS 100 05/20/14
CTC-110-02-01 TAS 100 02/13/12
CTC-109-02-01 TAS 100 02/13/12
Underwriters Laboratories,Inc. 94NK9632 Wind uplift resistance TAS 107 11/30/00
02NK42448 Wind uplift resistance TAS 107 11/08/02
09CA28873 Letter 07/23/09
11CA59020 TAS 107/ASTM D3161 01/25/12
11NK07864 TAS 107/ASTM D3161 09/29/11
07CA26696 TAS 107/ASTM D3161 09/21/07
11CA38844 TAS 107/ASTM D3161 01/28/12
11CA38844 TAS 107/ASTM D3161 01/27/12
I ICA38844 TAS 107/ASTM D3161 01/26/12
06CA02648 TAS 107/ASTM D3161 02/23/06
NOA No.: 14-0828.04
MIAMFDADE COUNTY= Expiration Date:02/28/17
Approval Date:02/12/15
Page 3 of 6
06CA28237 TAS 107/ASTM D3161 09/22/06
IONK17366 TAS 107/ASTM D3161 01/04/11
4786334383 TAS 107/ASTM D3161 05/28/14
4786307351 TAS 107/ASTM D3161/ASTM D 3462 05/13/14
11NK08333 ASTM D3462 05/15/12
l INK08333 ASTM D3462 04/15/12
11NK07864 ASTM D3462 09/29/11
11NK08333/Letter ASTM D3462/UL790 11/05/12
11NK08333/Letter ASTM D3462/UL790 11/05/12
11NK08333/Letter ASTM D3462/UL790 11/05/12
12NK13474 ASTM D3462/UL790 05/27/13
4786325932 ASTM D3462/UL790 04/04/14
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W,attached.
5. Nailing shall be in compliance with Detail W,attached.
LABELING
1. Shingles shall be labeled with the Miami-Dade Product Control approved seal as seen below or the wording
"Miami-Dade County Product Control Approved".
CM1AM=1DAD=EC0=UNTY
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 14-0828.04
MAMI-DADE COUNTY Expiration Date:02/28/17
Approval Date:02/12/15
Page 4 of 6
DETAIL A
Rake
Edge
s—�
5--j
16 3/4
6
5�
11
11
27 3/4
6—�
6 32 3AA
5 5/8 Full Starter
Shingle
Eaves
LANDMARK,LANDMARK PRO,LANDMARK PREMIUM,LANDMARK IMPACT RESISTANT,
LANDMARK SOLARIS,AND LANDMARK PRO/ARCHITECT 80
SHINGLE LAYOUT
NOA No.: 14-0828.04
MIAMMADE COUNTY Expiration Date:02/28/17
Ful Approval Date:02/12/15
Page 5 of 6
DETAIL B
1� 38 3/4"
Release Tape
Nailing area for"low and standard"slopes(from 3.5:12 to 21:12)
Nail between upper&lower nail lines.
" 12" 14 3/4" — 12" 13 1/4"
WIDE 1 1" �_
r 3�
4 0 risme`s::
NAILINGS►
AREA �7 1/2"
5 5/8" 6"
Exposure1 7
LANDMARK,LANDMARK PRO,LANDMARK PREMIUM,LANDMARK IMPACT RESISTANT,
LANDMARK SOLARIS,AND LANDMARK PRO/ARCHITECT 80
(LOW AND STANDARD SLOPE
Release Tape
Nailing area for"steep"slopes(greater than 21:12)
Nail between bottom 2 nail lines.
12" 14 3/4" 12" 13 1/4"
1" 1"
5 5/8" 61/8"
Exposure177 .
LANDMARK,LANDMARK PRO,LANDMARK PREMIUM,LANDMARK IMPACT RESISTANT,
LANDMARK SOLARIS,AND LANDMARK PRO/ARCHITECT 80
(STEEP SLOPE
END OF THIS ACCEPTANCE
NOA No.: 14-0828.04
MAMMADE COUNTY Expiration Date:02/28/17
Approval Date:02/12/15
Page 6 of 6
TRINITY ERD
APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application Type Description Page
1A-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4
3A-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5
1B Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5
1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6
1D Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6
1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 7-8
1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 8-9
1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 9
2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 30
2B Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 11-12
2C Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 13-14
3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 15-18
3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover 19-20
3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 21
4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 22-23
4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 24
4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 25-27
SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 28
5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 29
5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 30
5D CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 30
5E CWF New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 30
6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 31-32
6B Gypsum New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 33
6C Gypsum New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 33
6D Gypsum New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 33
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 34-36
78 Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 36
The followirm notes cooly to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement:
➢Wood: Minimum 0,75-inch penetration.
➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocya n u rate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the CIA
requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover.
Exterior Research and Design,LLC.d/b/a Trinity l ERD Evaluation Report P9290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of 36
TRINITY ERD
4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
5. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions.
➢ HA(HA): Full coverage at 25-30 lbs/square.
➢ Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.
➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c.
➢OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is
referenced.
➢ OlyBond Classic(OB Classic): Full coverage at 1 gal/square.
➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c.
➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
6. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick)
➢OMG OlyBond 500(OB500): MDP -45.0 psi (Min.0.5-inch thick Multi-Max FA-3)
➢OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL)
➢OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3)
➢OMG OlyBond 500(08500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II)
➢3M CR-20: MDP -117.5 psf (Min.1.0-inch thick)
7. Bonded polyisocya n u rate insulation boards shall be maximum 4 x 4 ft.
8. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29.
Assemblies marked with an asterisk'carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements.
9. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted.
10. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
11. For existing substrates in a bonded recover installation,the existing roof system shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of
resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1-52,ANSI/SPRI IA-1 or TAS 124.
12. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application.
13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck
construction and limitations. For systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,
reference is made to FBC Section 1917.4.1,Point 1.
Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 2 of 36
` TRINITY ERD
14. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications.
TABLE 1:POLYGLAss Row Cann
Reference Layer Material Application j
BP-AA Base Polyglass G2 Base,FBC Approved ASTM D4601,Type ii HA at 20-40 lbs/square
(Base and Ply sheets,Asphalt-Applied) Ply Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI
SBS AA
Base or Ply Elastobase,Elastobase Poly,Elastoflex V,Elastoflex S6,Polyglass HT Base 650(SBS,Asphalt-Applied) Cap Elastoflex 56, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G SBS(sand-backed), HA at 20-40 lbs/square
Polyfresko G SBS FR(sand-backed)
SBS-TA Base or Ply Elastoflex V,Elastoflex S6
{SBS,Torch-Applied} Cap
Elastoflex V,Elastoflex S6,Elastoflex S6 G,Elastoflex 56 G FR,Elastoshield TS-G,Elastoshield TS-G FR,Polyfresko G SBS(poly- Torch-Applied
film backed),Polyfresko G SBS FR(poly-film backed)
SBS-SA Base Elastoflex SA V Base,Elastoflex SA V FR Base,Elastoflex SA V Pius,Elastoflex SA V Plus FR
(SBS,Self-Adhering) Cap Elastoflex SA P,Elastoflex SA P FR,Polyrefiect Self-Adhering
APP-TA Base or Ply Polyglass APP Base,Polyflex,Polybond
Torch-Applied
(APP,Torch-Applied) Cap Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR
APP-SA
(APP,Self-Adhering) Cap Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool Self-Adhering
15. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings
associated with coating usage.
➢ PG200 Non Fibered Roof Coating;
➢ PG300 Fibered Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating;
> PG650 Fibered Aluminum Roof Coating;
A PG700 High Quality Elastomeric Roof Coating;
A PG800 Asphalt Emulsion Roof Coating;
➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
Y Polypius 65 Premium Fibered Aluminum Roof Coating;
➢ Polybrite 70 Premium Grade Elastomeric Roof Coating;
> Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
16. The following represent priming requirements for gypsum-based coverboards:
➢ Dens Deck and Dens Deck Prime shall be field-primed with PG140 prior to self-adhering or torch-applied membrane application. No priming is required for hot-asphalt membrane applications.
➢ SECUROCK Gypsum-Fiber Roof Board does not require field priming for any membrane application.
17. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design,LLC.d/b/a Trinity IERD Evaluation Report P9290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 3 of 36
TRINITY ERD
TABLE 1A-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP
No. (See Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap (Psf)
Polyglass G2 Base, Min.0.25-inch Dens Deck,
CertainTeed Glasbase,
32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)FBC Dens Deck Prime,SECUROCK
Approved,JM 19/32- Firestone MB Base,, inch diameter tin lap and 8-inch o.c. Gypsum-Fiber Roof Board, BP-AA (Optional) SBS-AA,
inch plywood Perma-Ply 28,Tamko ASTM 01289
W-1 caps with 11 ga. in three,equally HA Min.0.75-inch Fesco Board HA or SBS- BP-AA or SBS-TA, -60.0
Glass Base or GAFGLAS annular ring spaced,staggered polyiso (homogeneous)or min.0.5- AA SBS-AA APP-TA
#75 shank nails center rows inch Structodek High Density
Fiberboard Roof Insulation
Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c,in 4-inch (Optional)
CertainTeed Glasbase, (Optional)FBC SBS-SA,
inch diameter tin lap and 8-inch o.c. Min.0.25-inch Dens Deck, One or APP-SA,
Min.19/32- Firestone MB Base,JM Approved,
W-2 8acaps with 11 ga. in three,equally ASTM 01289 HA Dens Deck Prime,SECUROCK HA SBS-SA more SBS- SBS-TA, -60.0
inch plywood Perma-Ply 2 ,Tamko
Glass Base 8 G FG Tamko annular ring spaced,staggered polyiso Gypsum-Fiber Roof Board SA,SBS-TA, APP-TA
#75 shank nails center rows APP-TA
Polyglass G2 Base,
32 ga.,1-5/8- 8-inch o.c.in 4-Inch
CertainTeed Glasbase, (Optional)FBC (Optional)
inch diameter tin lap and 8-inch o.c. Min.0.25-inch Dens Deck,
Min.19/32- Firestone MB Base,JM Approved, Polyflex One or
W-3 inch plywood Perma-Ply 28,Tamko caps with 11 ga. in three,equally ASTM 01289 HA Dens Deck Prime, CK HA SA Base more APP- APP-TA 60.0
Glass Base or GAFGLAS annular ring spaced,staggered polyiso Gypsum-Fiber Rooff Board
oard TA
#75 shank nails center rows
32 ga.,1-5/8- 6-inch o.c.in 4-inch Min.2-inch DAS,OB500,
ACFoam ll,III, CR-20 or M- Min.0.25-inch Dens Deck, DAS,
inch diameter tin lap and 6-inch o.c. BP-AA (Optional) SBS-AA,
W-4 Min.19/32- Elastobase or caps with 12 ga. in four,equally H-Shield,H- OSFA,atop Dens Deck Prime or OBS00, or SBS- BP-AA or SBS-TA, -60.0'
inch plywood Elastobase Poly Shield CG, fastener SECUROCK Gypsum-Fiber CR-20 or
annular ring spaced,staggered 585-AA APP-TA
shank nails center rows Multi-Max FA3 rows,7-inch Roof Board M-OSFA
or ENRGY-3 O.C.
08500
2-inch D-IS, ,
32 ga.,1-5/8- 6-inch o.c,in 4-inch Min. (Optional)
O.C.Inch diameter tin lap and 6-Inch o. . ACFoam 11,111, CR-20 or M- D-IS, One or SBS-SA,
W-S caps with 12 ga. In four,equally
Min.19/32- Elastobase or H-Shield,H- OSFA atop (Optional)Additional layers OBS001 SBS-SA more SBS- APP-SA, -60.0'
inch plywood Elastobase Poly Shield CG, fastener of base Insulation CR-20 or SBS-TA,
annular ring spaced,staggered Multi-Max FA3 rows,7-Inch M-OSFA SA,SBS TA' APP-TA
shank nails center rows or ENRGY-3 O.C. APP-TA
32 ga.,1-5/9- 6-inch o.c.in flinch Min.2-Inch D-IS,06500,
Inch diameter tin lap and 6-inch o.c. ACFoam ll,111, CR-20 or M- D-IS, (Optional)
W-6 caps with 12 ga. in four,equally
Min.19/32- Elastobase or H-Shield,H- OSFA,atop (Optional)Additional layers OB500, Polyflex One or APP-TA -60.0•
inch plywood Elastobase Poly Shield CG, fastener of base insulation CR-20 or SA Base more APP-
annular ring spaced,staggered Multi-Max FA3 rows,7-inch M-OSFA TA
shank nails center rows
or ENRGY-3 o.c.
Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report P9290.02.08-R14 for FL1654-1116
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 36
TRINITY ERS
TABLE SA-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover
MDP(psf)
No. (See Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap
12-inch o.c.in 4- Min.0.25-inch Dens Deck,Dens
inch lap and 12- (Optional)FBC Deck Prime,SECUROCK Gypsum-
Min.19/32- Elastobase or inch o.c.in two, Approved,ASTM BP-AA or
OMG Flat Bottom Fiber Roof Board,Min.0.75-inch (Optional) SBS-AA,
W-7 Plates(square) olyiso-cyanSBS AA 11 HA Fesco Board(homogeneous)or HA BP-AA or SBS-TA, -60.0
inch plywood Elastobase Poly with Roofgrip#12 equally spaced, ptype urate min.0.5-inch Structodek High SBS-AA APP-TA
staggered center olyisDensity Fiberboard Roof
rows
Insulation
12-inch o.c.In 4- (Optional)
inch lap and 12- (Optional)FBC SBS-SA,
OMG Flat Bottom Min.0.25-inch Dens Deck,Dens One or
Min.19/32- Elastobase or inch o.c.in two, Approved,ASTM APP-SA,
W-8 Plates(square) HA Deck Prime,SECUROCK Gypsum- HA SBS-SA more SBS- -60.0
inch plywood Elastobase Poly equally spaced, C1289,type II APP- SBS-TA,
with Roofgrip#12 staggered center polyiso-cyanurate Fiber Roof Board SA, TA SBS-TA, APP-TA
rows
12-inch o.c.in 4-
inch lap and 12- (Optional)FBC (Optional)
OMG Flat Bottom Min.0.25-inch Dens Deck,Dens
Min.19/32- Elastobase or inch o.c.in two, Approved,ASTM Polyflex SA One or
W-9 Plates(square) HA Deck Prime,SECUROCK Gypsum- HA APP-TA -60.0
inch plywood Elastobase Poly equally spaced, C1289,type II Base more APP-
with Roofgrip#12 staggered center polyiso-cyanurate Fiber Roof Board TA
rows
TABLE 1B:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER
System Deck(See Base Insulation Layer Top Insulation Layer Roof Cover
MDP(psf)
— No. Note 1) Type Fasten Attach Type Attach Base Ply Cap
Min.1.5-inch ENRGY Dekfast Hex with Dekfast Min.0.75-Inch Fesco Board (Optional If (Optional If using AA SBS-AA,
W-10 Min.19/32- 3,H-Shield or #12 or Trufast 3"Metal 1 per 1.33 ftz (homogeneous)or min.0.5-inch HA using AA Ply) Base)One or more BP- SBS-TA, -60.0
Inch plywood Insulation Plate with Structodek High Density fiberboard BP-AA,SBS- AA,SBS-AA,SBS-TA or APP-TA
Polytherm Trufast DP Roof Insulation AA APP-TA
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 5 of 36
A6
TRINITY ERS
TABLE 1C:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
System Deck(See Top Insulation Layer Roof Cover
No. Note 1) Base Insulation Layer Type Fasten Attach Base Ply Cap MDP(psf)
Min.0.5-inch Structodek High Density
(Optional)One or more (Optional if using (Optional if using AA Base)
W-11 Min.19/32- layers,any combination, Fiberboard Roof Insulation or min.0.25- Dekfast Galvalume Steel Hex 1 per AA Ply)BP-AA SBS- One or more BP-AA,SBS- SBS-AA,SBS-TA, -82.5
inch plywood loose laid inch Dens Deck,Dens Deck Prime or with Dekfast#12 DP 1.33 ftAA AA,SBS-TA or APP-TA APP-TA
SECUROCK Gypsum-Fiber Roof Board
(Optional)One or more Dekfast Galvalume Steel Hex
W-12 Min.19/32- layers,any combination, Min.1.5-inch ENRGY 3,H-Shield or with Dekfast#12 DP or 1 per SBS-SA (Optional)One or more SBS-SA,APP-SA, -82.5
inch plywood loose laid Polytherm Trufast 3"Metal Insulation 1.33 ftSBS-SA,SBS-TA,APP-TA SBS-TA,APP-TA
Plate with Trufast DP
Dekfast Galvalume Steel Hex
Min.19/32- (Optional)One more Min.1.5-inch ENRGY 3,H-Shield or with Dekfast#12 DP or 1 per (Optional)One or more
W-13 inch plywood layers,any combination, Polytherm Trufast 3"Metal Insulation 1.33 ft' Polyflex SA Base APP-TA APP-TA 82.5
loose laid
Plate with Trufast DP
TABLE 1D:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE D:PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER
System Deck(See Insulation Layer(s) Base Sheet Roof Cover
MDP(psf)
No. Note 1) Type Attach Base Fasten Attach Ply Cap
One or more
Elastobase,Elastobase Poly,Polyglass OMG Flat Bottom Plates(square)
12-inch o.c.in 4-inch lap and 12- (Optional)One or SBS-AA,
Min.19/32- Prelim. G2 Base,CertainTeed Glasbase, with Roofgrip#14,Dekfast Hex with
W-14 layers,any inch o.c.in two,equally spaced, more BP-AA,SBS-AA, SBS-TA, -52.5
inch plywood combination Attached Firestone MB Base,1M Perma-Ply 28, Dekfast#14 or Trufast 3"Metal staggered center rows SBS-TA or APP-TA APP-TA
Tamko Glass Base or GAFG LAS#75 Insulation Plate with Trufast HD
One or more Dekfast Hex with Dekfast#14 or 12-inch o.c.in 4-inch lap and 12- SBS-SA,
Min.19/32- Prelim. Elastobase or Elastobase Poly with APP-SA, „
W-15 layers,any Trufast 3"Metal Insulation Plate inch o.c.in two,equally spaced, One or more SBS-SA -52.5
inch plywood combination Attached poly top surface with Trufast HD staggered center rows SBS-TA or
APP-TA
Min.19/32- One or more Prelim. Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or 12-Inch o.c.in 4-Inch lap and 12-
W-16 inch plywood layers,any Attached poly top surface Trufast r Metal Insulation Plate inch o.c.in two,equally spaced, Polyflex SA Base APP-TA -52.5
combination with Trufast HD staggered center rows
Min.19/32-
One or more Prelim. OMG Flat Bottom Plates(square) 12-Inch o.c.in 4-inch lap and 12- (Optional)One or SBS-AA,
Attached
W-17 layers,any Elastobase or Elastobase Poly Inch o.c.in two,equally spaced, more BP-AA,SBS-AA, SBS-TA, -60.0
Inch plywood combination with Roofgrip#12 staggered center rows SBS-TA or APP-TA APP-TA
One or more 12-inch o.c.in 4-inch lap and 12-
SBS-SA,
Min.19/32- Prelim. Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square) APP-SA,
W-18 inch plywood layers,any Attached poly top surface with Roofgrip#12 inch o.c.in two,equally spaced, One or more 585-SA SBS-TA or 60.0'
combination staggered center rows APP-TA
One or more 12-inch o.c.in 4-inch lap and 12-
W-19 Min.19/32- layers,any Prelim. Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square) inch o.c.in two,equally spaced, Polyflex SA Base APP-TA -60.0'
Inch plywood Attached poly tap surface with Roofgrip#12
combination staggered center rows
Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report P9290.02.08-1114 for FL1654-1116
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 6 of 36
TRINITY ERD
TABLE 1E-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover MDP
(Psfl
No. Note 1) Base Fasten Attach Ply Cap
Min.15/32- 9-inch o.c.at 2-inch lap and 18-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -45.0*
W-20 inch plywood Elastobase Simplex MAXX Cap two,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
W-21 Min.15/32- Elastobase Simplex MAXX Cap 9-inch o.c.at 2-inch lap and 12-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -52.5
inch plywood two,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
Original Simplex Cap Nails(1-inch metal head
Min.15/32- 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, SBS-SA,APP-SA
W-22 inch plywood Polyglass APP Base diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows (Optional)SBS-SA or APP-TA or APP-TA -52.5
grooved shank)
Min.15/32- Original Simplex Cap Nails(1-inch metal head 6-inch o.c.at 3-inch lap and 6-inch o.c.in four,
W-23 inch plywood Polyglass APP Base diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows Polyflex SA Base APP-TA -52.5
grooved shank)
Original Simplex Cap Nails(1-inch metal head SBS-SA,APP-SA,
Min.15/32- 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, (Optional)SBS-SA,SBS-TA or 585-TA or APP- -52.5
W-24 inch plywood Elastobase(with poly top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows APP-TA
grooved shank) TA
Original Simplex Cap Nails(1-inch metal head
Min.15/32- 6-inch o.c,at 3-inch lap and 6-inch o.c.in four,
W-25 inch plywood Elastobase(with poly top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows Polyflex SA Base APP-TA -52.5
grooved shank)
Original Simplex Cap Nails(1-inch metal head
Min.15/32- 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -52.5
W-26 inch plywood Elastobase(with sand top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
grooved shank)
Elastobase,Elastobase Poly,
Polyglass G2 Base,CertainTeed (Optional)One or more BP-
Min.19/32- Glasbase,FMB Base,JM 32 ga.,1-5/8-inch diameter tin caps with li ga. 8-inch o.c.in 4-inch lap and 8-inch o.c.in 565-AA,SBS-TA,
W-27 Firestone AA,5B5-AA,585-TA or APP-
inch plywood Tone Glass Base annular ring shank nails three,equally spaced,staggered center rows TA APP-TA -60.0
Perma-Ply ire
or GAFG LAS#75
Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-Inch diameter tin caps with it ga. 8-Inch o.c.in 41nch lap and 84nch o.c.In (Optional)One or more SBS- SBS-SA'APP-SA'
W-28 Inch plywood poly top surface annular ring shank nails three,equally spaced,staggered center rows SA,SBS-TA or APP-TA SBS-TA or APP- -60.0
TA
s
W-29 Min.19/32- Eiastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c.in 4-inch lap and 8-inch o.c.in Polyflex SA Base APP-TA -60.0
Inch plywood poly top surface annular ring shank nails three,equally spaced,staggered center rows
Min.15/32- 6-inch o.c.at 2-inch lap and 6-inch o.c.in two, (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -90.0
W-30 inch plywood Elastobase Simplex MARX Cap equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
W 31 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c.in 4-inch lap and 4-inch o.c.in four, (Optional)One or more SBS- SBS-SA,APP-SA,
SBS-TA or APP- 97.5
inch plywood poly top surface annular ring shank nails. equally spaced,staggered center rows SA,SBS-TA or APP-TA TA
W-32 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c.in 4-inch lap and 4-inch o.c,in four, Polyflex SA Base APP-TA -97.5
inch plywood poly top surface annular ring shank nails. equally spaced,staggered center rows
Exterior Research and Design,I.I.C.d/b/a Trinity)ERD Evaluation Report P9290.02.08-R34 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 7 of 36
TRINITY ERD
TABLE 1E-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover
MDP(psf)
No. Note 1) Base Fasten Attach Ply Cap
W-33 Min,15/32- Elastobase Simplex MAXX Cap 6-inch o.c.at 2-inch lap and 6-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -105.0
inch plywood three,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA
W-34 Min,19/32- Elastobase or Elastobase Poly 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c.in 4-inch lap and 6-inch o.c.in four, AA TA
(Optional)One or more BP-
SBS-TA or APP- SBS-AA,SBS-TA, -112.5
inch plywood annular ring shank nails equally spaced,staggered center rows TA , APP-TA
Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c.in 4-inch lap and 6-inch o.c.in four, (Optional)Elastoflex SA V SBS-SA,APP-SA,
equally spaced
W-35 annular ring shank nails. Note:Tin caps are to be Plus,Elastoflex SA V Plus FR, SBS-TA or APP- -112.5
inch plywood poly top surface primed with PG100 or ASTM D41 primer. ,staggered center rows SBS-TA or APP-TA TA
Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c.in 4-inch lap and 6-inch o.c.in four,
W-36 inch plywood annular ring shank nails. Note:Tin caps are to be Polyflex SA Base APP-TA 112.5
p y poly top surface primed with PG100 or ASTM D41 primer. equally spaced,staggered center rows
TABLE IE-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)ORRECOVER
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover
MDP(psf)
No. Note 1) Base Fasten Attach Ply Cap
Elastobase,Elastobase Poly,
Polyglass G2 Base,CertainTeed OMG Flat Bottom Plates(square)with Roofgrip (Optional)One or more BP-
Min.19/32- 12-inch o.c.in 4-inch lap and 12-inch o.c.in SBS-AA,SBS-TA,
W-37 inch plywood Glasbase,Firestone MB Base,JM #14,Dekfast Hex with Dekfast#14 or Trufast 3" two,equally spaced,staggered center rows AA,SBS-AA,SBS-TA or APP- APP-TA -52.5
Perma-Ply 28,Tamko Glass Base Metal Insulation Plate with Trufast HD TA
or GAFG LAS#75
W-38 Min.19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.in 4-inch lap and 12-inch o.c.in 585-SA,APP-SA,
One or more SBS-SA SBS-TA or APP- 52.5*
Inch plywood poly top surface Insulation Plate with Trufast HD two,equally spaced,staggered center rows TA
W-39 Min.19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.in 44nch lap and 12-Inch o.c.In Polyflex SA Base APP-TA 52.5•
Inch plywood poly top surface Insulation Plate with Trufast HD two,equally spaced,staggered center rows
W-40
Min.19/32- Elastobase or Elastobase Poly OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in AA,(Optional)One or more BP-
SBS-AA,SBS-TA or APP- SBS-AA,SBS-TA, -60.0
Inch plywood #12 two,equally spaced,staggered center rows TAAPP-TA
W 41 Min.19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in SBS-SA,APP-SA,
One or more SBS-SA SBS-TA or APP- 60.0*
inch plywood poly top surface #12 two,equally spaced,staggered center rows
TA
W-42 Min.19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in Polyflex SA Base APP-TA 60.0*
inch plywood I poly top surface #12 two,equally spaced,staggered center rows
Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report P9290.02.08-1114 for FL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 8 of 36
TRINITY ERD
TABLE 1E-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)ORRECovER
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREW$&PLATES),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover MDP(psf)
No. Note 1) Base Fasten Attach Ply Cap
OMG#12 Standard Roofgrip or OMG#14 Heavy
W-43 Min.15/32- Pol lass APP Base Duty min.1-5/8-inch Ion with OMG 3"Round three,nch equally
at 4-inch lap and 6-inch o.c.in
inch plywood yg y( g) three,equally spaced,staggered center rows (Optional)APP-TA APP-TA -90.0
Metal Plates or OMG Flat Bottom Metal Plates
OMG#12 Standard Roofgrip or OMG#14 Heavy
Min.15/32- 6-inch o.c.at 4-inch lap and 6-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA
W-44 inch plywood Elastobase(with sand top surface) Duty(min. s or OMG long)with Me l Round three,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA 90.0
Metal Plates or OMG Flat Bottom Metal Plates
W-45 Min.15/32- Elastobase(with sand top surface) Trufast#12 DP or Trufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.c.in 90.0
inch plywood long)with Trufast 3"Metal Insulation Plates three,equally spaced,staggered center rows (Optional)BP-AA or SBS-AA SBS-AA
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch lap and 6-inch o.c.in five,
W-46 inch plywood Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round equally spaced,staggered center rows (Optional)APP-TA APP-TA -120.0
Metal Plates or OMG Flat Bottom Metal Plates
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch lap and 6-inch o.c.in five, (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA
W-47 inch plywood Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA -120.0
Metal Plates or OMG Flat Bottom Metal Plates
W-48 Min.15/32- Elastobase(with sand top surface) Trufast#12 DP or Trufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.c.in five,
inch plywood long)with Trufast 3"Metal Insulation Plates equally spaced,staggered center rows (Optional)BP-AA or 585-AA SBS-AA 120.0
TABLE 1F:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER
System Deck(See Roof Cover
Primer MDP(psf)
No. Note 1) Joint Treatment Base Ply Cap
W-49 Min.15/32- (Optional)PG100 None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -90.0
inch plywood TA,APP-TA TA,APP-TA
W-50 Min.15/32- (Optional)PG100 None Polyflex SA Base (Optional)One or more APP-TA -90.0
_ Inch plywood APP-TA
s W-51 Min.15/32- (Optional)PG100 Plywood Joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled Into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS -97.5
Inch plywood place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA
Min.15/32- Plywood Joints are covered with 4-Inch wide strips of Elastoflex SA V Plus,rolled Into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W-52 inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA 135.0
W-53 Min.15/32• Polyfiex SA Base Plywood Joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled Into (Optional)One or more APP-TA 135
inch plywood (Optional)PG100 place to create continuous bond. APP-TA .0
Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-R14 for FL16S4-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 9 of 36