Loading...
HomeMy WebLinkAboutNotice of Acceptance TRINITY ERD APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4 1A-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5 18 Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5 1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6 1D Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6 1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 7-8 1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 8-9 1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 9 2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Mech.Attached Base insulation,Bonded Top Insulation,Bonded Roof Cover 10 2B Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 11-12 2C Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 13-14 3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 15-18 3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover 19-20 3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 21 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 22-23 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 24 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 25-27 SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 28 5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 29 5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 30 5D CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 30 5E CWF New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 30 6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 31-32 6B Gypsum New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 33 6C Gypsum New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 33 6D Gypsum New,Reroof(Tear-Off)or Recover E Non-Insulated,Mach.Attached Base Sheet,Bonded Roof Cover 33 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 34-36 78 Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 36 The folkawlna notes aooW to the systems outNned herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: ➢Wood: Minimum 0.75-inch penetration. ➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the CIA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. Exterior Research and Design,U.C.d/b/a Trinity l ERD Evaluation Report P9290.02.08-R14 for FL1654-R16 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of 36 TRINITY ERD 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FEC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ HA(HA): Full coverage at 25-30 lbs/square. ➢ Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢ Millennium One Step Foamabie Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢ OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢OlyBond Classic(OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. ➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing. ➢Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya n u rate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) ➢OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) ➢OMG OlyBond 500(013500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL) ➢ OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II) ➢ 3M CR-20: MDP -117.5 psf (Min.1.0-inch thick) 7. Bonded polyisocya n u rate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk`carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 10. For mechanically attached components over existing decks,fasteners shall be tested In the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover InstaAation,the existing roof system shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1-52,ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. 13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,LLC.d/b/a Trinity l ERD Evaluation Report P9290.02.08-1114 for FL1654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 2 of 36 TRINITY ERD 14. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. TABLE 1:PoLyGiAss RooF CovERs Reference Layer Material Application BP-AA Base Polyglass G2 Base,FBC Approved ASTM D4601,Type 11 HA at 20-40 lbs/square (Base and Ply sheets,Asphalt-Applied) Ply Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI SBS-AA Base or Ply Elastobase,Elastobase Poly,Elastoflex V,Elastoflex S6,Polyglass HT Base 650 Elastoflex S6, Elastoflex S6 G,Elastoflex S6 G FR, Elastoshield TS-G,Elastoshield TS-G FR, Polyfresko G SBS(sand-backed), HA at 20-40 lbs/square (SBS,Asphalt-Applied) Cap Polyfresko G SBS FR(sand-backed) SBS-TA Base or Ply Elastoflex V,Elastoflex S6 (SBS,Torch-Applied) Cap Elastoflex V,Elastoflex S6,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield TS-G FR,Polyfresko G SBS(poly- Torch-Applied film backed),Polyfresko G SBS FR(poly-film backed) SBS-SA Base Elastoflex SA V Base,Elastoflex SA V FR Base,Elastoflex SA V Plus,Elastoflex SA V Plus FR Self-Adhering (SBS,Self-Adhering) Cap Elastoflex SA P,Elastoflex SA P FR,Polyreflect APP-TA Base or Ply Polyglass APP Base,Polyflex,Polybond Torch-Applied (APP,Torch-Applied) Cap Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR APP-SA Cap Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool Self-Adhering I (APP,Self-Adhering) I I 15. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance, Refer to current Roofing Materials Directory for fire ratings associated with coating usage. > PG200 Non Fibered Roof Coating; )o PG300 Fibered Roof Coating; > PG600 Non-Fibered Aluminum Roof Coating; > PG650 Fibered Aluminum Roof Coating; > P6700 High Quality Elastorneric Roof Coating; > PG800 Asphalt Emulsion Roof Coating; > Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; > Polypius 65 Premium Fibered Aluminum Roof Coating; > Potvbrite 70 Premium Grade Elastomeric Roof Coating; > Potybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating. 16, The following represent priming requirements for gypsum-based coverboards: > Dens Deck and Dens Deck Prime shall be field-primed with PG100 prior to self-adhering or torch-applied membrane application, No priming is required for hot-asphalt membrane applications. > SECUROCK Gypsum-Fiber Roof Board does not require field priming for any membrane application. 17. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design,U.C.d/b/a Trinity l ERD Evaluation Report P9290.02,08-1114 for FI-1654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nierninen,PE-59166 Appendix 1,Page 3 of 36 TRINITY ERD TABLE 3A-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP No. (See Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap (Psf) Polyglass G2 Base, Min.0.25-inch Dens Deck, CertainTeed Glasbase, 32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)FBC Dens Deck Prime,SECUROCK 1M 19/32- Firestone MB BaseApproved, Min. , inch diameter tin lap and 8-inch o.c. Gypsum-Fiber Roof Board, BP-AA (Optional) SBS-AA, inch plywood Perma-Ply 28,Tamko ASTM 01289 W-1 caps with 11 ga. in three,equally HA Min.0.75-inch Fesco Board HA or SBS- BP-AA or SBS-TA, -60.0 Glass Base or GAFGLAS annular ring spaced,staggered polyiso (homogeneous)or min.0.5- AA SBS-AA APP-TA #75 shank nails center rows inch Structodek High Density Fiberboard Roof Insulation Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional) CertainTeed Glasbase, (Optional)FBC SBS-SA, inch diameter tin lap and 8-inch o.c. Min.0.25-inch Dens Deck, One or Min.19/32- Firestone MB Base,1M Approved, APP-SA, W-2 inch plywood Perma-Ply 28,Tamko caps with li ga. in three,equally HA Dens Deck Prime,SECUROCK HA SBS-SA more 565- SBS-TA, -60.0 Glass Base 8 G TamkoFG annular ring spaced,staggered polyiso ASTM 01289 Gypsum-Fiber Roof Board SA,SBS-TA, APP-TA #75 shank nails center rows APP-TA Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c,in 4-inch CertainTeed Glasbase, (Optional)FBC (Optional) inch diameter tin lap and 8-inch o.c. Min.0.25-inch Dens Deck, Min.19/32- Firestone MB Base,1M Approved, Polyflex One or W 3 inch plywood Perma-Ply 28,Tamko caps with SI ga. in three,equally ASTM 03289 HA Dens Deck Prime, CK HA SA Base more APP- APP-TA 60.0 Glass Base or GAFGLAS annular ring spaced,staggered polyiso Gypsum-Fiber Rooff Board oard TA #75 shank nails center rows 32 ga.,1-5/8- 6-inch o.c.in 4-inch Min.2-inch D-IS,OB500, ACFoam II,III, CR-20 or M- Min.0.25-inch Dens Deck, D-IS, inch diameter tin lap and 6-inch o.c. BP-AA (Optional) SBS-AA, W-4 Min.19/32- Elastobase or caps with 12 ga. in four,equally H-Shield,H- OSFA,atop Dens Deck Prime or OB500, or SBS- BP-AA or SBS-TA, -60.0* inch plywood Elastobase Poly Shield CG, fastener SECUROCK Gypsum-Fiber CR-20 or annular ring spaced,staggered AA SBS-AA APP-TA shank nails center rows Multi-Max FA3 rows,7-inch Roof Board M-0SFA or ENRGY-3 O.C. 08500 2-inch D-IS, , 32 ga.,1-5/8- 6-Inch o.c.in 4-Inch Min. (Optional) Inch diameter tin lap and 6-inch O.C. CFoam 11,111, CR-20 or M- D-IS, SBS-SA, Min.19/32- Elastobase or c. One or H-Shleld,H- OSFA,atop (Optional)Additional layers 08500, APP-SA, W-S caps with 12 ga. in four,equally SBS-SA more SBS- -60.0• Inch plywood Elastobase Poly annular ring spacedstaggered SA,SBS-TA,Shield CG, fastener of base Insulation CR-20 or SBS-TA, _ , shank nails center rows Muni-Max FA3 rows,7-inch M-0SFA APP-TA APP-TA or ENRGY-3 O.C. Min.2-Inch D-IS,OBS00, In ga., met lap an o.c.in o.ch ACFoam II,III, CR-20 or M- D-IS, (Optional) Inch diameter tin lap and 6-inch o.c. Min.19/32- Elastobase or H-Shield,H- OSFA,atop (Optional)Additional layers OB500, Polyflex One or W-6 caps with 12 ga. in four,equally APP-TA -60.0* inch plywood Elastobase Poly Shield CG, fastener of base insulation CR-20 or SA Base more APP- annular ring spaced,staggered Multi-Max FA3 rows,7-inch M-0SFA TA shank nails center rows or ENRGY-3 O.C. Exterior Research and Design,LLC.d/b/a Trinity l ERD Evaluation Report P9290.02.08-1114 for FL1654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 36 TRINITY ERD TABLE 1A-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP(psf) No. (See Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap 12-inch o.c.in 4- Min.0.25-inch Dens Deck,Dens inch lap and 12- (Optional)FBC Deck Prime,SECUROCK Gypsum- Min.19/32- Elastobase or inch o.c.in two, Approved,ASTM BP-AA or OMG Flat Bottom Fiber Roof Board,Min.0.75-inch (Optional) SBS-AA, W-7 Plates(square) olyiso-cyanSBS-AA 11 HA Fesco Board(homogeneous)or HA BP-AA or SBS-TA, -60.0 inch plywood Elastobase Poly with Roofgrip#12 equally spaced, ptype urate min.0.5-inch Structodek High SBS-AA APP-TA staggered center olyisDensity Fiberboard Roof rows Insulation 12-inch o.c.in 4- (Optional) inch lap and 12- (Optional)FBC SBS-SA, Min.19/32- Elastobase or OMG Flat Bottom inch o.c.in two, Approved,ASTM Min.0.25-inch Dens Deck,Dens One or APP-SA, W-8 inch plywood Elastobase Poly Plates(square) equally spaced, C1289,type II HA Deck Prime,SECUROCK Gypsum- HA SBS-SA more SBS-rd SA,SBS-TA, SB5-TA, 60.0 with Roofgrip#12 staggered center polyiso-cyanurate Fiber Roof Boa APP-TA APP-TA rows 12-inch o.c.in fl- inch lap and 12- (Optional)FBC (Optional) OMG Flat Bottom Min.0.25-inch Dens Deck,Dens Min.19/32- Elastobase or inch o.c.in two, Approved,ASTM Polyflex SA One or 60.0 W-9 inch plywood Elastobase Poly Plates(square) equally spaced, C1289,type 11 HA Deck Prime,SECUROCK Gypsum- HA Base more APP- APP-TA with Roofgrip#12 staggered center polyiso-cyanurate Fiber Roof Board TA rows TABLE 1B:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER System Deck(See Base Insulation Layer Top Insulation Layer Roof Cover MDP(psf) No. Note 1) Type Fasten Attach Type Attach Base Ply Cap Min.1.5-inch ENRGY Dekfast Hex with Dekfast Min.0.75-inch Fesco Board (Optional if (Optional If using AA SBS-AA, W-10 3 H-Shield or 1 per 1.33 ftz Min.19/32- #12 or Trufast 3"Metal HA(homogeneous)or min.0.5-inch using AA Ply) Base)One or more BP- S85-TA, -60.0 Inch plywood Po,lytherm Insulation Plate with Structodek High Density Fiberboard BP-AA,SBS AA,SBS-AA,SBS-TA or APP TA Trufast DP Roof insulation AA APP-TA Exterior Research and Design,LLC,d/b/a Trinity(ERD Evaluation Report P9290.02.08-R34 for FL3654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 5 of 36 4 TRINITY ERD TABLE 1C:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck(See Top Insulation Layer Roof Cover Base Insulation Layer MDP(psf) No. Note 1) Type Fasten Attach Base Ply Cap Min.0.5-inch Structodek High Density (Optional)One or more (Optional if using (Optional if using AA Base) W-il Min.19/32- Fiberboard Roof insulation or min.0.25- Dekfast Galvalume Steel Hex 1 per AA Ply)BP-AA,SBS- One or more BP-AA,SBS- SBS-AA,SBS-TA, -82.5 la ers,any combination, inch plywood loose laid inch Dens Deck,Dens Deck Prime or with Dekfast#12 DP 1.33 ft' AA AA,SBS-TA or APP-TA APP-TA SECUROCK Gypsum-Fiber Roof Board Dekfast Galvalume Steel Hex Min.19/32- (Optional)One or more Min.1.5-inch ENRGY 3,H-Shield or with Dekfast#12 DP or 1 per (Optional)One or more SBS-SA,APP-SA, W-12 inch plywood layers,any combination, Polytherm Trufast 3"Metal Insulation 1.33 ft2 SBS-SA SBS-SA,SBS-TA,APP-TA SBS-TA,APP-TA 82.5 loose laid Plate with Trufast DP Dekfast Galvalume Steel Hex Min.19/32- (Optional)One or more Min.1.5-inch ENRGY 3,H-Shield or with Dekfast#12 DP or 1 per (Optional)One or more W-13 layers,any combination, 2 Polyflex SA Base APP-TA 82.5 inch plywood loose laid Polytherm Trufast 3"Metal Insulation 1.33 ftAPP-TA Plate with Trufast DP TABLE 11):WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D:PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck(See Insulation Layer(s) Base Sheet Roof Cover MDP(psf) No. Note 1) Type Attach Base Fasten Attach Ply Cap Elastobase,Elastobase Poly,Polyglass OMG Flat Bottom Plates(square) 12-inch o.c.in 4-inch la and 12- (Optional)One or SBS-AA, One or more p ( P ) Min.19/32- Prelim. G2 Base,CertainTeed Glasbase, with Roofgrip#14,Dekfast Hex with inch o.c.in two,equally spaced, more BP-AA,SBS-AA, SBS-TA, -52.5 W-14 inch plywood layers,any Attached Firestone MB Base,JM Perma-Ply 28, Dekfast#14 or Trufast 3"Metal q y p combination staggered center rows SBS-TA or APP-TA APP-TA Tamko Glass Base or GAFGLAS#75 Insulation Plate with Trufast HD SBS-SA, 52.5 One or more Dekfast Hex with Dekfast#14 or 12-inch o.c.in 4-inch lap and 12- Min.19/32- Prelim. Elastobase or Elastobase Poly with APP-SA, „ W-15 layers,any Trufast 3"Metal Insulation Plate inch o.c.in two,equally spaced, One or more SBS-SA SBS-TA or inch plywood combination Attached poly top surface with Trufast HD staggered center rows APP-TA One or more Dekfast Hex with Dekfast#14 or 12-inch o.c.in 4-Inch lap and 12- W-16 inch plywoywo Min.19/32- Prelim. Elastobase or Elastobase Poly with Trufast 3"Metal Insulation Plate Inch o.c.in two,equally spaced, Polyflex SA Base APP-TA -52.5' plywood combination Wpm,any �� poly top surface with Trufast HD staggered center rows Min.19/32- One or more PrelimOMG Fist Bottom Plates(square) 12-inch o.c.In 4-Inch lap and 12- (Optional)One or SBS-AA, . W-17 inch plywood layers,any Attached Elastobase or Elastobase Poly with Roofgrip#12 Inch o.c.in two,equally spaced, more BP-AA,SBS-AA, SBS-TA, -60.0 combination staggered center rows SBS-TA or APP-TA APP TA One or more 12-inch o.c.in 4-inch lap and 12- SBS-SA, APP-SA Min.19/32- Prelim. Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square) inch o.c.in two,equally spaced, One or more SSS-SA -60.0` W-18 inch plywood layers,any Attached poly top surface with Roofgrip#12 q y P , combination staggered center rows SBS-TA or APP-TA One or more 12-inch o.c.in 4-inch lap and 12- Min. Prelim. Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square) inch o.c.in two,equally aced, Pol lex SA Base APP-TA 60.0' W-19 inch plywood layers,any Attached poly top surface with Roofgrip#12 combination r y sp staggered center rows Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-1114 for F1,1654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 6 of 36 TRINITY ERD TABLE 1E-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover MDPsf (P ) No. Note 1) Base Fasten Attach Ply Cep W-20 Min.15/32- Elastobase Simplex MAXX Cap 9-inch o.c.at 2-inch lap and 18-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -45.0* inch plywood two,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA Min.15/32- 9-inch o.c.at 2-inch lap and 12-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA 52.5 W-21 inch plywood Elastobase Simplex MAXX Cap two,equally y spaced,staggered ered center rows 585-TA or APP-TA or APP-TA Min.15/32- Original Simplex Cap Nails(1-inch metal head 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, SBS-SA,APP-SA W-22 Polyglass APP Base diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows (Optional)SBS-SA or APP-TA or APP-TA -52.5 inch plywood grooved shank) q y P Min.15/32- Original Simplex Cap Nails(1-inch metal head 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, W-23 inch plywood equally spaced,staggered center rows Polyglass APP Base diameter,11 gauge x min.1.25-inch long annular Polyflex SA Base APP-TA -52.5 grooved shank) Original Simplex Cap Nails(1-inch metal head SBS-SA,APP-SA, Min.15/32- 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, (Optional)SBS-SA,SBS-TA or SBS-TA or APP- -52.5 W-24 inch plywood Elastobase(with poly top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows APP-TA grooved shank) TA Min.15/32- Original Simplex Cap Nails(1-inch metal head 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, 52.5 W-25 inch plywood Elastobase(with poly top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows Polyflex SA Base APP-TA grooved shank) Min.15/32- Original Simplex Cap Nails(1-inch metal head 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, (Optional)BP-AA,SBS-AA, SBS-AA,SB5-TA W-26 Elastobase(with sand top surface) diameter,I gauge x min.1.25-inch long annular -52.5 inch plywood grooved shank) equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA Elastobase,Elastobase Poly, Polyglass G2 Base,CertainTeed (Optional)One or more BP- W 27 Min.19/32- Glasbase,Firestone MB Base,JM 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c.in 4-inch lap and 8-inch o.c.in AA 585-AA,SBS-TA or APP- SBS-AA,SBS-TA, -60.0 inch plywood Permase, ire toneTamkGlass Base annular ring shank nails three,equally spaced,staggered center rows TA APP-TA or GAFGLAS#75 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-Inch diameter tin caps with 11 ga. 84nch o.c.in 41nch lap and&inch o.c.in (Optional)One or more SBS- SBS-SA'APP-SA' W-28 inch plywood poly top surface annular ring shank nails three,equally spaced,staggered center rows SA,SBS-TA or APP-TA SBS-TA or APP- 60.0 TA W-29 Min.19/32- Elastobase or Elastobase Poly with 32&a.,1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c.in 4-Inch lap and 8-inch o.c.in Polyflex SA Base APP-TA -60.0 Inch plywood poly top surface annular ring shank nails three,equally spaced,staggered center rows Min.15/32- 6-inch o.c.at 2-Inch lap and 6-Inch o.c.in two, (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -90.0 W-30 inch plywood Elastobase Simplex MARX Cap equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA W 31 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c.in 4-inch lap and 4-inch o.c.in four, (Optional)One or more SBS- SBS-SA,APP-SA, SBS-TA or APP- 97.5 inch plywood poly top surface annular ring shank nails. equally spaced,staggered center rows SA,SBS-TA or APP-TA TA W-32 in.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-Inch diameter tin caps with 11 ga. 4-inch o.c.in 4-inch lap and 4-inch o.c.in four, Polyflex SA Base APP-TA -97.5 inch plywood poly top surface annular ring shank nails. equally spaced,staggered center rows Exterior Research and Design,I.I.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-R14 for FL1654-1136 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 7 of 36 _{ TRINITY ERS TABLE 1E-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover MDPs 1p fl No. Note 1) Base Fasten Attach Ply Cap W-33 Min.15/32- Elastobase Simplex MAXX Cap 6-inch o.c.at 2-inch lap and 6-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -105.0 inch plywood three,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA (Optional)One or more BP- W-34 Min.19/32- Elastobase or Elastobase Poly 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c.in 4-inch lap and 6-inch o.c.in four, � SBS-AASBS-TA or APP- SBS-AA,SBS-TA, -112.5 inch plywood annular ring shank nails equally spaced,staggered center rows TA , APP-TA 32 ga.,1-5/8-inch diameter tin caps with it ga. (Optional)Elastoflex SA V SBS-SA,APP-SA, W-35 Min.19/32- Elastobase or Elastobase Poly with annular ring shank nails. Note:Tin caps are to be 6-inch o.equally spp in ,inch lap and 6-inch o staggered center rows in four, Plus,Elastoflex SA V Plus FR, SBS-TA or APP- -112.5 inch plywood poly top surface primed with PG100 or ASTM D41 primer. acedd, SBS-TA or APP-TA TA W-36 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular ring shank nails. Note:Tin caps are to be 6-inch o.c.in 4-inch lap and 6-inch o.c.in four, polyflex SA Base APP-TA -112.5 inch plywood poly top surface primed with PG100 or ASTM D41 primer. equally spaced,staggered center rows TABLE 1E-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)ORRECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover MDP(psf) No. Note 1) Base Fasten Attach Ply Cap Elastobase,Elastobase Poly, Polyglass G2 Base,CertainTeed OMG Flat Bottom Plates(square)with Roofgrip (Optional)One or more BP- W 37 Min.19/32- Glasbase,Firestone MB Base,JM #14,Dekfast Hex with Dekfast#14 or Trufast 3" 12-inch all in 4-inch lap and 12-inch r roo.cws in AA SBS-AA,SBS-TA or APP- SBS-AA,SBS-TA, -52.5 inch plywood Perma-Ply 28,Tamko Glass Base Metal Insulation Plate with Trufast HD two,equally spaced,staggered center rows TA APP-TA or GAFGLAS#75 SBS-SA,APP-SA, W-38 Min.19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.in 4-inch lap and 12-inch o.c.in One or more SBS SA SBS-TA or APP- 52.5* Inch plywood poly top surface Insulation Plate with Trufast HD two,equally spaced,staggered center rows TA W-39 Min.19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.In flinch lap and 12-inch o.c.in Polyflex SA Base APP TA -52.5* Inch plywood poly top surface Insulation Plate with Trufast HD two,equally spaced,staggered center rows Min.19/32- OMG Flat Bottom Plates(square)with Roofgrip (Optional)One or more BP- 12-Inch o.c.in 4-inch lap and 12-inch o.c.in SBS-AA,SBS-TA, W-40 Inch plywood Elastobase or Elastobase Poly #12 two,equally spaced,staggered center rows Aa SBS-AA,SBS-TA or APP- APP TA -60.0 TA 585-SA,APP-SA, W-41Min.19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in One or more SBS-SA SBS-TA or APP- 60.0* inch plywood poly top surface #12 two,equally spaced,staggered center rows TA W-42 Min.19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in Polyflex SA Base APP-TA 60.0* inch plywood poly top surface #12 two,equally spaced,staggered center rows Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1114 for FL1654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 8 of 36 TRINITY ERS TABLE 1E-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)ORRECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover MDP (per No. Note 1) Base Fasten Attach Ply Cap OMG#12 Standard Roofgrip or OMG#14 Heavy W-43 Min.15/32- Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round three,nch o.c.at 4-inch lap and 6 inch o.c.in (Optional)APP-TA APP-TA 90.0 inch plywood Metal Plates or OMG Flat Bottom Metal Plates three,equally spaced,staggered center rows OMG#12 Standard Roofgrip or OMG#14 Heavy Min.15/32- 6-inch o.c.at 4-inch lap and 6-inch o.c.in (Optional)BP-AA,SBS-AA, 565-AA,585-TA -90.0 W-44 inch plywood Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round three,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA Metal Plates or OMG Flat Bottom Metal Plates Min.15/32- Trufast#12 DP or Trufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.c.in O W-45 inch plywood Elastobase(with sand top surface) long)with Trufast 3"Metal Insulation Plates three,equally spaced,staggered center rows (Optional) 90.0 )BP-AA or S85-AA SBS-AA Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch lap and 6-inch o.c.in five, W-46 inch plywood Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round equally spaced,staggered center rows (Optional)APP-TA APP-TA 120.0 Metal Plates or OMG Flat Bottom Metal Plates OMG#12 Standard Roofgrip or OMG#14 Heavy Min.15/32- 6-inch o.c.at 4-inch lap and 6-inch o.c.in five, (Optional)BP-AA,585-AA, SBS-AA,SBS-TA _120.0 W-47 inch plywood Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA Metal Plates or OMG Flat Bottom Metal Plates Min.15/32- Trufast#12 DP or Trufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.cin five, (Optional)BP-AA or SBS-AA SBS-AA 120.0 W-48 inch plywood Elastobase(with sand top surface) long)with Trufast 3"Metal Insulation Plates equally spaced,staggered center rows (O p TABLE 1F:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck(See Primer Roof Cover MDP(psf) No. Note 1) Joint Treatment Base Ply Cap Min.15/32- (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- W�t9 inch plywood (Optional)PG100 None SBS-SA 90.0 TA,APP-TA TA,APP-TA W-50 Min.15/32- (Optional)PG100 None Polyflex SA Base (Optional)One or more APP-TA -90.0 _ Inch plywood APP-TA Min.15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus,rolled Into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-Sq,APP-SA,585- 97 5 W-51 inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA Min.15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus,rolled Into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -135.0 W-52 inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA W-43 Min.15/32- Polyflex SA Base Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled Into (Optional)One or more APP-TA 135.0 inch plywood (Optional)PG100 place to create continuous bond. APP-TA Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-1114 for FL1654-R16 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 9 of 36 TRINITY ERD APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4 1A-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5 1B Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5 1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6 1D Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6 1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 7-8 1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 8-9 1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 9 2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 10 2B Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 11-12 2C Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 13-14 3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 15-18 3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover 19-20 3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 21 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 22-23 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 24 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 25-27 5A CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 28 5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 29 5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 30 5D CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 30 5E CWF New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 30 6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 31-32 6B Gypsum New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 33 6C Gypsum New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 33 61) Gypsum New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 33 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 34-36 78 Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 36 The folkawina notes apply to the systems outbned herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: ➢Wood: Minimum 0.75-inch penetration. ➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the QA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-R34 for FL1654-R16 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of 36 TRINITY ERD 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ HA(HA): Full coverage at 25-30 lbs/square. ➢ Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢ OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic(OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. ➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing. ➢Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya nu rate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) ➢OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) ➢OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL) ➢OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3) ➢OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II) ➢ 3M CR-20: MDP -117.5 psf (Min.1.0-inch thick) 7. Bonded polyisocyanu rate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk'carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 10. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation,the existing roof system shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1-52,ANSI/SPRi IA-1 or TAS 124. 12. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. 13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC Is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,LLC.d/b/a Trinityl ERD Evaluation Report P9290.02.08-1114 for FL1654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 2 of 36 d N O r� J� d W� w � K d+ O G 7 y� o U �O 0. a t' A O u a °7t� a d a b -iY ✓A y A o a ✓ p A �D Q Y , G d 0 0 o0 V" 6 4 a x 'ya 0 a O � G 0 J O O Z G ps J, d J dYO � a 6 W0. d O S X. O N ? �O O u J 9A Z Y y 7 O 6 N % m O O 9 p0 'O �' N G d u' m D N D d o U O N p, '-o Zj O 'N T s p o uA+ x - O°. ,Opp. LL o- m 'NO o- C 6 7 O o>a s K O N d N N a 9 N p � fr S N O y� j. X p� V ✓ �i 'o �D S O y y l7 G A N O m --o % R01 Ndi+ X b 0.tNAJ~O O4•a'y NAT 0._0.N N y"' t 7 N%i✓%d A 6%N p .rO 0,--- m0. y -O N0 O uO %O yOd -00 �y A i oD O S O d N X N fr O 9 u+ R O 0. QR o o y " 7 N A d y d N 0. J A J R ��S Yy1 0 6 O d N D S G N O J 6y2 O cn y0- SO.l o oNu o$ a co 3 0 o u CAW. d `ot d 6 y d Q N U 6.d d 0 9 •3 N m m W N p 9 N N $•4 g 'a 0 3o y d d a° ° o. o- ° o sa o a a s y o 4 � o. o s o r cs• .r. m \ d a m Nk c a ERD TRINITY TABLE 1A-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP No. (See Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap (Psf) Polyglass G2 Base, Min.0.25-inch Dens Deck, CertainTeed Glasbase, 32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)FBC Dens Deck Prime,SECUROCK Approved,1M 19/32- Firestone MB Base,, inch diameter tin lap and 8-inch o.c. Gypsum-Fiber Roof Board, BP-AA (Optional) SBS-AA, inch plywood Perma-Ply 28,Tamko ASTM 01289 W-1 caps with 11 ga. in three,equally HA Min.0.75-inch Fesco Board HA or SBS- BP-AA or SBS-TA, -60.0 Glass Base or GAFGLAS annular ring spaced,staggered polyiso (homogeneous)or min.0.5- AA SBS-AA APP-TA #75 shank nails center rows inch Structodek High Density Fiberboard Roof Insulation Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional) ) SBS-SA, CertainTeed Glasbase, (Optional)FBC inch diameter tin lap and 8-inch o.c. Min.0.25-inch Dens Deck, One or APP-SA, Min.19/32- Firestone MB Base,JM Approved, W 2 inch plywood Perma-Ply 28,Tamko caps with 11 ga. in three,equally ASTM 03289 HA Dens Deck Prime,SECUROCK HA SBS-SA more SBS- SBS-TA, 60.0 Glass Base or GAFGLAS annular ring spaced,staggered polyiso Gypsum-Fiber Roof Board SA,SBS-TA, APP-TA #75 shank nails center rows APP-TA Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c.in 4-inch CertainTeed Glasbase, (Optional)FBC (Optional) inch diameter tin lap and 8-inch o.c. Min.0.25-inch Dens Deck, Min.19/32- Firestone MB Base,JM Approved, Polyflex One or W-3 inch plywood Perma-Ply 28,Tamko caps with 11 ga. in three,equally ASTM 01289 HA Dens Deck Prime, CK HA SA Base more APP- APP-TA 60.0 Glass Base or GAFGLAS annular ring spaced,staggered polyiso Gypsum-Fiber Rooff Board oard TA #75 shank nails center rows 32 ga.,1-5/8- 6-inch o.c.in 4-inch Min.2-inch D-IS,OBSOO, ACFoam 11,III, CR-20 or M- Min.0.25-inch Dens Deck, D-IS, inch diameter tin lap and 6-Inch o.c. BP-AA (Optional) SBS-AA, W-4 Min.19/32- Elastobase or caps with 12 ga. in four,equally H-Shield,H- OSFA,atop Dens Deck Prime or 08500, or SBS- BP-AA or SBS-TA, -60.0' inch plywood Elastobase Poly Shield CG, fastener SECUROCK Gypsum-Fiber CR-20 or annular ring spaced,staggered SBS-AA APP-TA shank nails center rows Multi-Max FA3 rows,7-inch Roof Board M-OSFA or ENRGY-3 O.C. — 32 ga.,i-5/& Min.2-inch D-IS,6-inch o.c.in 4-inch OB500, (Optional) Inch diameter tin lap and 6-Inch O.C. One or ACFoam Il,III, CR-20 or M- D-IS, SBS-SA, W-5 caps with 12 ga. in four,equally Min.19/32- Elastobase or H-Shield,H- OSFA,atop (Optional)Additional layers OB500, SBS-SA more SBS APP-SA, -60.0' Inch plywood Elastobase Poly Shield CG, fastener of base Insulation CR-20 or SBS-TA, annular spaced,staggered Shield FA3 rows,7-Inch M-OSFA SBS-TA, APP-TA shank nails ls center rows or ENRGY-3 O.C. APP-TA 32 ga.,1-5/8- 6-inch o.c.In flinch Min.2-Inch D-IS,08500, inch diameter tin lap and 6-inch o.c. ACFoam Ii,111, CR-20 or M- D-IS, (Optional) W-6 caps with 12 ga. in four,equally Min.19/32- Elastobase or H-Shield,H- OSFA,atop (Optional)Additional layers 08500, Polyflex One or APP-TA -60.0' inch plywood Elastobase Poly Shield CG, fastener of base insulation CR-20 or SA Base more APP- shankannular nails spaced,staggered Multi-Max FA3 rows,7-inch M-OSFA TA APP- shank nails center rows or ENRGY-3 O.C. Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report P9290.02.08-1114 for FL1654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 36 TRIt�{1TY ERD TABLE IA-2;WOOD DECKS—NEW CONSTRUCTION,REROOF{TEAR-OFF)OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base insulation Top Insulation Roof Cover MDP(psf) No. (See Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap 12-Inch o.c,in 4- Min.0.25-inch Dens Deck,Dens inch lap and 12- (Optional)FBC Deck Prime,SECUROCK Gypsum- OMG Flat BottomFiber Roof Board,Min.0,75-inch (Optional) SBS-AA, Min.19/32- Elastobase or inch o.c.in two, Approved,ASTM BP-AA or W-7 Plates(square) HA Fesco Board(homogeneous)or HA BP-AA or S85-TA, -60.0 inch plywood Elastobase Poly with Roofgrip#12 equally spaced, C1289,type 11 min.0.5-inch Structodek High SBS-AA SBS-AA APP-TA staggered center polyiso-cyanurate Density Fiberboard Roof rows Insulation 12-Inch o.c.in 4- (Optional) inch lap and 12- (Optional)FBCc.in twoASTM Prim SBS-SA, Min.19/32- Elastobase or OMG Flat Bottom inch o. , Approved, Min. ,S APP-SA Dens Deck,Dens One or , W-8 Plates(square) HA peck Prime, ECUROCK Gypsum- HA SBS-SA more SBS- -60.0 inch plywood Elastobase Poly with Roofgrip#12 equally spaced, 01289,type 11 Fiber Roof Board SA,SBS-TA, SBS-TA, staggered center polyiso-cyanurate APP-TA APP-TA rows 12-inch o.c.in 4- inch lap and 12- (Optional)FBC (Optional) OMG Fiat Bottom Min.0.25-inch Dens Deck,Dens Min.19/32- Elastobase or inch o.c.in two, Approved,ASTM Polyflex SA One or W 9 inch plywood Elastobase Poly Plates(square} equally spaced, C1289,type 11 HA Deck Prime,oaCUROCK Gypsum- HA Base more APP- RPP-TA 60.0 with Roofgrip#12 staggered center polyiso-cyanurate Fiber Roof Board TA rows TABLE 16:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER System Deck(See Base Insulation Layer Top Insulation Layer Roof Cover MDP(psf) — No. Note 1) Type Fasten Attach Type Attach Base Ply Cap Belfast Hee with Dekfast Min.0.7S-inch Fesco board {Optional if (Optional if using AA Min.1.5-Inch ENRGY 585-AA, Min.19/32- #12 or Trufast 3"Metal (homogeneous)or min.0.5-lnch using AA Ply) Base)One or more BP- W-14 3.H-Shield or 1 per 1.33 ftz HA SBS-TA, -60.0 Inch plywood Polytherm Insulation Plate with Structodek High Density fiberboard BP-AA,SBS AA,SBS-AA,SSS-TA or APP-TA Trufast DP Roof insulation AA APP-TA Exterior Research and Design,LLC.d/b/a Trinity IERD Evaluation Report P9290.02.08-R14 for FL1654-R16 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 5 of 36 TRINITY ERS TABLE 1C:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck(See Top Insulation Layer Roof Cover No. Note 1) Base Insulation Layer Type Fasten Attach Base Ply Cap MDP(psf) Min.0.5-inch Structodek High Density if using (Optional if using AA Base (Optional)One or more (Optional 6 ( P� B ) Min.19/32- Fiberboard Roof Insulation or min.0.25- Dekfast Galvalume Steel Hex 1 per AA PI BP-AA,SBS- One or more BP-AA,SBS- SBS-AA,SBS-TA, -82.5 W-11 inch plywood layers,any combination, inch Dens Deck,Dens Deck Prime or with Dekfast#12 DP 1.33 ftz y) APP-TA loose laid SECUROCK Gypsum-Fiber Roof Board AA AA,585-TA or APP-TA (Optional)One or more Dekfast Galvalume Steel Hex W-12 Min.19/32- layers,any combination, Min.1.5-inch ENRGY 3,H-Shield or with Dekfast#12 DP or 1 per SBS-SA (Optional)One or more SBS-SA,APP-SA, 82 5 inch plywood loose laid Polytherm Trufast 3"Metal Insulation 1.33 ft SBS-SA,SBS-TA,APP-TA SBS-TA,APP-TA Plate with Trufast DP Dekfast Galvalume Steel Hex Min.19/32- (Optional)One more Min.1.5-inch ENRGY 3,H-Shield or with Dekfast#12 DP or 1 per (Optional)One or more W-13 inch plywood layers,any combination, Polytherm Trufast 3"Metal Insulation 1.33 ftz Polyflex SA Base APP-TA APP-TA 82.5 loose laid Plate with Trufast DP TABLE 1D:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D:PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck(See Insulation Layer(s) Base Sheet Roof Cover MDP(psf) No. Note 1) Type Attach Base Fasten Attach Ply Cap Elastobase,Elastobase Poly,Polyglass OMG Flat Bottom Plates(square) One or more 12-inch o.c.in 4-inch lap and 12- (Optional)One or SBS-AA, Min.19/32- Prelim. G2 Base,CertainTeed Glasbase, with Roofgrip#14,Dekfast Hex with inch o.c.in two,equally spaced, more BP-AA,SBS-AA, SBS-TA, -52.5 W-14 inch plywood layers,any Attached Firestone MB Base,1M Perma-Ply 28, Dekfast#14 or Trufast 3"Metal q y P combination staggered center rows SBS-TA or APP-TA APP-TA Tamko Glass Base or GAFGLAS#75 Insulation Plate with Trufast HD One or more Dekfast Hex with Dekfast#14 or 12-inch o.c.in 4-inch lap and 12- SBS-SA, Min.19/32- Prelim. Elastobase or Elastobase Poly with APP-SA, * W-15 layers,any Trufast 3"Metal Insulation Plate inch o.c.in two,equally spaced, One or more SBS-SA -52.5 inch plywood combination Attached poly top surface with Trufast HD staggered center rows SBS-TA or APP-TA Min.19/32- One or more Prelim. Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or 12-Inch o.c.in flinch lap and 12- W-16 layers,any Trufast 3"Metal Insulation Plate Inch o.c.In two,equally spaced, Polyft SA Base APP-TA -52.5 Inch plywood combination Attached poly top surface with Trufast HD staggered center rows One or more 12-inch o.c.in 4-inch lap and 12- (Optional)One or SBS-AA, W-17 Min.19/32- layers,any Prelim.Attached Elastobase or Elastobase Poly OMG Flat Bottom Plates(square) Inch o.c.in two,equally spaced, more BP-AA,SBS-AA, SBS-TA, -60.0 Inch plywood combination with Roofgrip#12 staggered center rows SBS-TA or APP-TA APP-TA One or more 12-inch o.c.in 4-inch lap and 12- 585-SA, Min.19/32- Prelim. Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square) APP-SA, W-18 inch plywood layers,any Attached poly top surface with Roofgrip#12 inch o.c.in two,equally spaced, One or more SBS-SA SBS-TA or 60.0* combination staggered center rows APP-TA One or more 12-inch o.c.in 4-inch lap and 12- Min.19/32- Prelim. Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square) inch o.c.in two,equally spaced, Pol lex SA Base APP-TA W-19 layers,any q Y P Yf inch plywood combination Attached poly top surface with Roofgrip#12 staggered center rows Exterior Research and Design,I.I.C.d/b/a Trinity)ERD Evaluation Report P9290.02.08-R14 for FL1654-R16 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 6 of 36 I TRINITY ERD TABLE 1E-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover MDP(psi) No. Note 1) Base Fasten Attach Ply Cap Min.15/32- 9-inch o.c.at 2-inch lap and 18-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA _45.0* W-20 inch plywood Elastobase Simplex MAXX Cap two,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA Min.15/32- 9-inch o.c.at 2-inch lap and 12-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA _52.5 W-21 inch plywood Elastobase Simplex MARX Cap two,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA Original Simplex Cap Nails(1-inch metal head Min.15/32- 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, SBS-SA,APP-SA W-22 inch plywood Polyglass APP Base diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows (Optional)SBS-SA or APP-TA or APP-TA -52.5 grooved shank) Original Simplex Cap Nails(1-inch metal head Min.15/32- 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, W-23 inch plywood Polyglass APP Base diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows Polyflex SA Base APP-TA -52.5 grooved shank) Original Simplex Cap Nails(1-inch metal head SBS-SA,APP-SA, W-24 Min.15/32- Elastobase(with poly top surface) diameter,11 gauge x min.1.15-inch long annular equally o.c.at 3-inch lap and enter r o s in four, (Optional)SBS-SA,SBS-TA or SBS-TA or APP- -52.5 inch plywood grooved shank) equally spaced,staggered center rows APP-TA TA Original Simplex Cap Nails(1-inch metal head Min.15/32- 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, W-25 inch plywood Elastobase(with poly top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows Polyflex SA Base APP-TA -52.5 grooved shank) Min.15/32- Original Simplex Cap Nails(1-inch metal head 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA W-26 inch plywood Elastobase(with sand top surface) diameter,11 gauge x min.1.25-inch long annular equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA -52.5 grooved shank) Elastobase,Elastobase Poly, Polyglass G2 Base,CertainTeed (Optional)One or more BP- Min.19/32- 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c.in 4-inch lap and 8-inch o.c.in SBS-AA,SBS-TA, W-27 inch plywood Glasbase,Firestone MB Base,JM annular ring shank nails three,equally spaced,staggered center rows AA,SBS-AA,SBS-TA or APP- APP-TA -60.0 Perma-Ply 28,Tamko Glass Base TA or GAFG LAS#75 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,i-5/84nch diameter tin caps with 11 ga. 8-Inch o.c.in 44rich lap and 8-Inch o.c.in (Optional)One or more SBS- SBS-SA,APP-SA' W-28 inch plywood poly top surface annular ring shank nails three,equally spaced,staggered center rows SA,SBS-TA or APP-TA SBS-TA or APP- -60.0 TA W-29 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c.in 4-inch lap and 8-inch o.c.in Polyflex SA Base APP-TA -60.0 inch plywood poly top surface annular ring shank nails three,equally spaced,staggered center rows Min.15/32- 6-inch o.c.at 2-inch lap and 6-inch o.c.in two, (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -90.0 W-30 inch plywood Elastobase Simplex MARX Cap equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA W-31 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c.in 4-inch lap and 4-inch o.c.in four, (Optional)One or more SBS- SBS-SA,APP-SA, SBS-TA or APP- 97.5 inch plywood poly top surface annular ring shank nails. equally spaced,staggered center rows SA,SBS-TA or APP-TA TA W-32 in.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-Inch diameter tin caps with 11 ga. 4-inch o.c.in 4-inch lap and 4-inch o.c.in four, Polyflex SA Base APP-TA -97.5 inch plywood poly top surface annular ring shank nails. equally spaced,staggered center rows Exterior Research and Design,U.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1114 for FL1654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 7 of 36 1 TRINITY'ERS TABLE 1E-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover MDP(psf) No. Note 1) Base Fasten Attach Ply Cap W-33 Min.15/32- Elastobase Simplex MAXX Cap 6-inch o.c.at 2-inch lap and 6-inch o.c.in (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA -105.0 inch plywood three,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA Min.19/32- 32 ga.,1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c.in 4-inch lap and 6-inch o.c.in four, (Optional)One or more BP- SBS-AA,SBS-TA, W-34 inch plywood Elastobase or Eiastobase Poly annular ring shank nails equally spaced,staggered center rows AA,SBS-AA,SBS-TA or APP- APP TA -112.5 TA 32 ga.,1-5/8-inch diameter tin caps with 11 ga. (Optional)Elastoflex SA V SBS-SA,APP-SA, equally spaced,W-35 Min.19/32- Elastobase or Elastobase Poly with annular ring shank nails. Note:Tin caps are to be 6-inch o.c.in ,inch lap and enter o s in four, Plus,Elastoflex SA V Plus FR, SBS-TA or APP- -112.5 inch plywood poly top surface primed with PG100 or ASTM D41 primer. staggered center rows SBS-TA or APP-TA TA W-36 Min.19/32- Elastobase or Elastobase Poly with 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular ring shank nails. Note:Tin caps are to be 6-inch o.c.in 4-inch lap and 6-inch o.c.in four, polyflex SA Base APP-TA -112.5 inch plywood poly top surface primed with PGS00 or ASTM D41 primer. equally spaced,staggered center rows TABLE 1E-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)ORRECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover MDP(psf) No. Note 1) Base Fasten Attach Ply Cap Elastobase,Elastobase Poly, Polyglass G2 Base,CertainTeed OMG Flat Bottom Plates(square)with Roofgrip (Optional)One or more BP- W 37 Min.19/32- Glasbase,Firestone MB Base,JM #14,Dekfast Hex with Dekfast#14 or Trufast 3" 12-inch o.c.in 4-inch lap and 12-inch o.c.in AA SBS-AA,SBS-TA or APP- 585-AA,SBS-TA, -52.5 inch plywood Perma-Ply 28,Tamko Glass Base Metal Insulation Plate with Trufast HD two,equally spaced,staggered center rows TA APP-TA or GAFG LAS#75 SBS-SA,APP-SA, W-38 Min.19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.in 4-inch lap and 12-inch o.c.in One or more SBS-SA SBS-TA or APP- 52.5" Inch plywood poly top surface Insulation Plate with Trufast HD two,equally spaced,staggered center rows TA W-39 Min.19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.in 4-Inch lap and 12-inch o.c.in Polyflex SA Base APP-TA -52.5' Inch plywood poly top surface Insulation Plate with Trufast HD two,equally spaced,staggered center rows (Optional)One or more BP- W-40 Min.19/32- Elastobase or Elastobase Poly OMG Flat Bottom Plates(square)with Roofgrip 12-Itwo,eh all in flinch lap and 12-inch r rows In AA SBS-AA,SBS-TA or APP- SBS-AA,SBS-TA, -60.0 Inch plywood #12 two,equally spaced,staggered center rows TA APP-TA W-41 Min.19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in SBS-SA,APP-SA, One or more SBS-SA SBS-TA or APP- 60.0' inch plywood poly top surface #12 two,equally spaced,staggered center rows TA W-42 Min.19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in Polyflex SA Base APP-TA inch plywood I poly top surface #12 two,equally spaced,staggered center rows Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report 139290.02.08-1114 for F1.1654-1116 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 8 of 36 , TRINITY ERD TABLE SE-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)ORRECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover MDP(psf) No. Note 1) Base Fasten Attach Ply Cap OMG#12 Standard Roofgrip or OMG#14 Heavy W-43 Min.15/32- Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round 6-inch o.c.at 4-inch lap and 6-inch o.c.in (Optional)APP-TA APP-TA -90.0 inch plywood Metal Plates or OMG Flat Bottom Metal Plates three,equally spaced,staggered center rows OMG#12 Standard Roofgrip or OMG#14 Heavy Min.15/32- 6-inch o.c.at 4-inch lap and 6-inch o.c.in (Optional)BP-AA,SBS-AA, 585-AA,SBS-TA W-44 inch plywood Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round three,equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA -90.0 Metal Plates or OMG Flat Bottom Metal Plates Min,15/32- Trufast#12 DP or Trufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.c,in W-45 inch plywood Elastobase(with sand top surface) long)with Trufast 3"Metal Insulation Plates three,equally spaced,staggered center rows (Optional)BP-AA or SBS-AA SBS-AA 90.0 Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch lap and 6-inch o.c.in five, W-46 inch plywood Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round equally spaced,staggered center rows (Optional)APP-TA APP-TA -120.0 Metal Plates or OMG Flat Bottom Metal Plates OMG#12 Standard Roofgrip or OMG#14 Heavy Min.15/32- 6-inch o.c.at 4-inch lap and 6-inch o.c.in five, (Optional)BP-AA,SBS-AA, SBS-AA,SBS-TA W-47 Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round -120.0 inch plywood Metal Plates or OMG Flat Bottom Metal Plates equally spaced,staggered center rows SBS-TA or APP-TA or APP-TA W-48 Min.15/32- Elastobase(with sand top surface) Trufast#12 DP or Trufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.c.in five, (Optional)BP-AA or SBS-AA SBS-AA -120.0 inch plywood long)with Trufast 3"Metal Insulation Plates equally spaced,staggered center rows TABLE 1F:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck(See Primer Roof Cover MDP(psi) No. Note 1) Joint Treatment Base Ply Cap — W-49 Min.15/32- (Optional)PG100 None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -90.0 Inch plywood TA,APP-TA TA,APP-TA W-50 Min.15/32- (Optional)PG100 None P°lyflex SA Base (Optional)One or more App TA -90.0 _ Inch plywood APP-TA Min.15/32- Plywood joints are covered w(th 4-Inch wide strips of Elastoflex SA V Plus,rolled Into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS W-51 Inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA 97.5 Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Pius,rolled into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- W-52 inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA 135.0 W-53 Min.15/32- Polyflex BasePlywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled Into (Optional)One or more APP-TA inch plywood (Optional)PG100 place to create continuous bond. APP-TA 135.0 Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report P9290.02.08-R14 for FL1654-R16 Certificate of Authorization#9503 Revision 14:06/17/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 9 of 36