Loading...
HomeMy WebLinkAboutProduct approval 6/30/2015 Florida Building Code Online Professionalt 1 r ,r Rr e—.4 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links Search Busines tri Professional Pro PobliApProval Regulation Product ADDroval Menu>Product or Aoolication Search>Application List>Application Detail FL# FL2569-R9 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Soprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON-US 00000 (819)478-2400 Ext 3327 memathieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memathieu@soprema.ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 lea n-Berchmans-Michaud Drummondville, NON-US 00000 (819)478-2400 Ext 3327 memathieu@soprema.ca Quality Assurance Representative Jean-Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888) 811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert J. M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL2569 R9 COI 2015 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM D6163 2000 ASTM D6164 2005 FM 4474 2004 FRSA/TRI April 2012 (04-12) 2012 TAS 103 1995 hftps://floridabuildi ng.org/pr/pr_app_o.aspx?param=wGEVXQwtDgsKQFEnckBI08Erxl Ud3xYIX2%2f%2bLT9pl88%3d 1/2 6/30/2015 Florida Building Code Online TAS 110 2000 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/17/2015 Date Validated 04/21/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Date Revised 06/29/2015 Summary of Products . _.......-' __. -—...- — ._...._.......... .. . --...-.__ ................ ..... ... -- - .... FL# Model Number or Name Description 2569.1 Soprema Roof Self adhering roof underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL2569 R9 II 2015 04 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- Approved for use outside HVHZ:Yes R9.Ddf Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166 Design Pressure: +N/A/-90 Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Limits of Evaluation Reports Use. 2.)The design pressure noted herein FL2569 R9 AE 2015 04 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-i pertains to underlayment systems used R9.odf beneath adhesive-set tile systems. Refer to Created by Independent Third Party: Yes ER Section 5.6.4 for details. i... --- .............. _............_.---__ .....-_........ _.-.-__ ,tact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail,If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ® xccuritv+o�•:i�<�cs https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB108Erx1 U d3xYIX2%2f%2bLT9p188%3d 2J2 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY cD G1�D 353 CHRISTIAN NOXFORD, CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Soprema, Inc. Evaluation Report S18010.06.09-R7 1640 rue Haggerty FL2569-R9 Drummondville,Quebec J2C 5P8 Date of Issuance:06/15/2009 Canada Revision 7:04/17/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M.Nieminen P.E. The facsimile seal appearing was authorized byRobert Nieminen, %TF'•. C?��.•f.^;' P.E.on 04/17/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 �s.;��a�`�;•`` document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and tothe named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2004 1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009 1507.4.5.1,1507.5.3,1507.7.3 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 TAS 110 Accelerated Weathering TAS 110 2000 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007 ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007 ERD(TST6049) ASTM 01970/TAS 110 513190.02.09-R1 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-Ri 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2 10/05/2010 ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011 ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Physical Properties/Accelerated Weathering SOPC-SC8520.14 04/17/2015 M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010 M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014 ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: 4.1 Lastobond TU HT is a self-adhering,non-woven polyester fabric surfaced,SBS modified bitumen roof underlayment. 4.2 Lastobond Shield is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. 4.3 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.4 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. 4.5 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.6 Lastobond 195 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment. 4.7 Lastobond is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment. 4.8 Lastobond Eco is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment. Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R7 Certificate of Authorization#9503 FL2569-R9 Revision 7:04/17/2015 Page 2 of 6 TRINITY ERD 4.9 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment. 4.10 Resisto LB1236 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.11 PrimeSource Grip-Rite Eave &Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.12 Resisto LB1244 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with a 44-inch sheet width. 4.13 Colphene FR GR is a self-adhering,fiberglass reinforced,granule-surfaced,SBS modified bitumen roof underlayment. 4.14 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof underlayment. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are follows: TABLE 1:ROOF COVER OPTIONS Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate Shingles Shingles Lastobond TU HT Yes Yes See 555.1 YeYes Yes Yes Lastobond Shield/Pro HT-N Yes No No No Yes Yes Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes Lastobond/Lastobond 195 Yes No No No Yes Yes Lastobond ECO /Resisto L81236, Grip-Rite Eave&Valley Protector/ Yes No No No Yes Yes Resisto LB1244 Lastobond Smooth Seal HT Yes No No Yes Yes Yes Ye Colphene FR GR Yes Yes See 555.1 No Yes Yes Unilay(e) Yes Yes Yes No No No Batten Only See 5.5.1 5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. Underlayment Adhesive(s) Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBondT1 Roof Tile Adhesive(FL717) Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) Exterior Research and Design,LLC. Evaluation Report 538030.06.09-R7 Certificate of Authorization#9503 FL2569-R9 Revision 7:04/17/2015 Page 3 of 6 ­_.I' TRINITY ERD 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Lastobond Shield,Lastobond Pro HT-N,Lastobond Shield HT or Lastobond Pro HT-S applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, Resisto LB1236, Grip-Rite Eave & Valley Protector, Resisto LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OS8 or Southern Yellow Pine substrates, Soprema recommends priming with Elostocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond Pro HT-S or Colphene FR GR applied to: ➢ DensDeck DuraGuard;DensDeck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. 5.6.3 Bond to Mechanically Attached Base Laver: Lastobond Shield,Lastobond Pro HT-N,Lastobond Shield HT,Lastobond Pro HT-S or Colphene FR GR applied to: ➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems,base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5.6.4.1 Maximum Design Pressure=-45.0 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)Elastocol Stick or Elastocol 600c Underlayment: Colphene FR GR,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: Elastocol 600c Underlayment: Colphene FR GR,self-adhered. 5.6.4.3 Maximum Design Pressure=-60.0 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in three,equally spaced rows in the center of the sheet. Underlayment: Colphene FR GR,self-adhered Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R7 Certificate of Authorization#9503 FL2569-R9 Revision 7:04/17/2015 Page 4 of 6 4 1 TRINITY,ERa 5.6.4.4 Maximum Design Pressure=-90.0 Psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Underlayment: Unilay(e)mechanically attached with Soprafix Polymer Batten Bar(PBB)or Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. within the 5-inch wide, self- adhering side laps. End laps are 6-inch wide and sealed using either heat-welding or hot-air welding techniques. 5.7 Exposure Limitations: 5.7.1 Lastobond Shield,Lastobond Pro HT-N,Lastobond,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,Resisto LB1236, Grip-Rite Eave&Valley Protector or Resisto LB1244 shall not be left exposed for longer than 30-days after installation. 5.7.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation. 5.7.3 Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer than 180-days after installation. 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick or Elastocol 600c(if applicable). 6.3 Lastobond TU HT Lastobond Shield Lastobond Pro HT-N Lastobond Shield HT, Lastobond Pro HT-S, Lastobond, Lastobond 195 Lastobond Eco Lastobond Smooth Seal HT Resisto LB1236, Grip-Rite Eave & Valley Protector, Resisto L81244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not stated for installation within 24 hours. Apply sheet parallel to the roof edge. Rall out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge.Drape and press sheet into place,working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For Colphene FR GR in foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R7 Certificate of Authorization#9503 FL2569-R9 Revision 7:04/17/2015 Page 5 of 6 ;fit^ A{'TRINITYERa 6_4 Unila e : 6.4.1 Non-Tile Applications or Nail-On.Battened Tile Applications: Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if applicable). Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope, mechanically attach the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-nails spaced 36-inch o.c. Apply the second course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over- granule end-laps shall be sealed using either heat-welding or hot air welding techniques. Tile (if applicable) shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6.4.2 Foam-On Tile Applications: Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein. Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope, mechanically attach the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar (PBB) or Soprafix Metal Batten Bar (MBB)with Soprema#15-EL fasteners spaced 6-inch o.c. Apply the second course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over- granule end-laps shall be sealed using either heat-welding or hot air welding techniques. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 OA requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R7 Certificate of Authorization#9503 FL2569-119 Revision 7:04/17/2015 Page 6 of 6 9/24/2015 Florida Building Code Online llkli;;'Professionat Regulation ��;,rlo u,�G�rlr,ant,i SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications '.. FBC Staff BCIS Site Map Links Search Busines Professional ` SER °"a' Regulation Product ADDroval Menu>Product or ADolication Search>Application List>Application Detail FL# FL10758-R6 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity Miami-Dade BCCO-QUA Quality Assurance Contract Expiration Date 04/13/2018 Validated By Locke Bowden ,,' Validation Checklist- Hardcopy Received Certificate of Independence FL10758 R6 COI OCR14003 2 2014 FBC nonHVHZ Evaluation Report Owens Corning Vents 060514.pdf Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 1709.2 https://floridabuildi ng.org/pr/pr_app_c tl.aspx?param=wGEVXQwtDgvl dAviteOY0%2bC3zFtrydg9ubW M rxzLHkvl rEPVYDH9EQ°/`3d%3d 1/2 9(24;015 Florida Building Code Online Product Approval Method Method 2 Option B Date Submitted 02/23/2015 Date Validated 02/24/2015 Date Pending FBC Approval 03/01/2015 Date Approved 04/15/2015 Summary of Products FL# Model,Number or Name Description 10758.1 VentSure 4-Foot Strip Heat and Copolymer plastic low profile attic ridge vents for installation Moisture Ridge Vents in shingle roof systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758 R6 II OCR14003 2 2014 FBC nonHVHZ Evaluation Approved for use outside HVHZ:Yes Reoort Owens Corning Vents 060514 Ddf Impact Resistant:N/A Verified By: Zachary R. Priest 74021 G Design Pressure:N/A Created by Independent Third Party: Yes Other: Refer to evaluation report Evaluation Reports FL10758 R6 AE OCR14003 2 2014 FBC nonHVHZ Evaluation Report Owens Corning Vents 060514 odf -- Created by Independent Third Party: Yes 10758.2 VentSure Low Profile Slant Back Galvanized metal roof vent Roof Vent With Exterior Louver Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758 R6 It QCR14003 2 2014 FBC nonHVHZ Evaluation Approved for use outside HVHZ:Yes Reoort Owens Corning Vents 060514 Ddf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to evaluation report. Evaluation Reports FL10758 R6 AE OCR14003 2 2014 FBC nonHVHZ Evaluation Reoort Owens Corning Vents 060514 Ddf Created by Independent Third Party: Yes 10758.3 VentSure Rigid Roll Ridge Vent Ridge Ventilation System Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758 R6 11 OC'R14003 2 2014 FBC nonHVHZ Evaluation Approved for use outside HVHZ:Yes Report Owens Corning Vents 060514 Ddf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party: Yes Other: Refer to evaluation report. Evaluation Reports FL10758 R6 AE OCRI4003.2 2014 FBC nonHVHZ Evaluation Report Owens Corning Vents 060514 Ddf Created by Independent Third Party: Yes Contact Us:: 1940 North Monroe Street,Tallahassee FL 3.2399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida, :: Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1345.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: am®H] S`t`j,(`ilfltl'�<1i Itlt 11.1 https://floridabuilding,org/pr/pr app d 1.aspx?param=wGEVXQwtDgvldAviteOYO%2bC3zFtrydg9ubWMrxzLHkvlrEPVYDH9EQ%3d%3d 2l`2 R Certificate of Authorization No. 29824 17520 Edinburgh Dr CREEK Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued February 23, 2015 1 Owens Corning Parkway Toledo,OH 43657 (800)438-7465 www.owenscornino.com Manufacturing Plants: Rohnert Park,CA;Orrick, MO; Baldwyn, MS; Niles, OH Quality Assurance: Miami-Dade BCCO—QUA(QUA1591) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1709.2 Properties: Roof Ventilation REFERENCES Entit Report No. Standard Year Architectural Testing,Inc(TST1558) 01-38660.04 TAS 100(A) 1995 Architectural Testing,Inc(TST1558) 01-38660.05 TAS 100(A) 1995 Architectural Testing, Inc(TST1558) C1774.01-109-18 TAS 100(A) 1995 ASTM D 635 2006 ASTM D 1929 2001 e01 ASTM D 2843 2004e01 PRI Construction Materials Technologies(TST5878) AVIG-005-02-01 ASTM D 635 2006 ASTM D 1929 2001e01 ASTM D 2843 2004e01 PRI Construction Materials Technologies(TST5878) AVIG-006-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) OCF-1 11-02-01 ASTM D 635 2006 ASTM D 1929 2001 e01 ASTM D 2843 2004e01 PRI Construction Materials Technologies(TST5878) 0CF-112-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) OCF-116-02-01 TAS 110(A) 1995 PRI Construction Materials Technologies(TST5878) OCF-223-02-01 TAS 110(A) 1995 PRI Construction Materials Technologies(TST5878) OHI-007-02-01 TAS 100(A) 1995 PRODUCT DESCRIPTION AND APPLICATION VentSurev4-Foot Strip 1-1/4" x 14-7/8" x 48" low-profile attic ridge vent consisting of a two-layer nylon- Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for Vents: installation in shingle roof systems. 48" - 1 14-7/8" OCR14003.2 FL10758-R6 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ` . ovvswaCORNING ROOFING ANDASPHALT LLC CREEK ve"tSpmrRoof Ventilation TECHNICAL SERVICES, LLC Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck ahm|| he designed and installed in accordance with FBC requirements, Roof slope: Minimum 3:12Vomaximum 1012 Installation Height: Moxmum00'ft Attachment Method: Cut a2-inohopening (1'nchoneonhoideof#mridge)oentemdinUedeckot the ridge for ventilation. The slot shall hanninaha approximately 0'inohmofrom the rake edges. Apply o %,inch wide bead of ASTM D 4586 roofing cement along the onhna length of the outside edges of the vent to seal the vent to the field shingles, taking care to no, completely cover the weep slots in the vent, Center the vent over the opening and fasten to the deck using the 11 ga, 2Y2-inch galvanized ring shank nails (shall comply with F8CSection 15OO.5) provided with the vent. Fasteners are\obe installed nnboth sides o/the vent 1. 12. 24. 36. and 47-inohesfrom the start nfeach vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent,and fasten to the deck in the same manner as the first section. Fasten the ridge shingles over the vent tothe deck onthe marked "shingle nail line" with two (2) minimum 11 0a. 2|6'inchgalvanized ring shank roofing nails (ehd| comply with FBC Section 1586.5) pmided with the vent o/es directed by the shingle manufacturer's installation instructions. Outside edges of the shingles shall besealed with flashing cement. Allowable Roof Coverings: Asphalt shingles VontSum~Low Profile 18^x24^x2'3/18^(32^x23''flange base)static off-ridge vent composed nfASTM Slant Back Roof Vent AO53galvanized steel(available with painted finioh). Material shall conform with with Exterior Louver: F8CSection 1507.4.3. ----------r -/ ~ / | | � ' / Deck Type: Roof deck oba8 be constructed of closely fitted sheathing for now or existing construction. Roof deck nho|| be designed and installed in accordance with FBC requirements. OCR14003.2 FPage am* OWENS CORNING ROOFING AND ASPHALT LLC CREEK VentSure®Roof Ventilation TECHNICAL SERVICES, LLC Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement around inner and outer flange. Place vent directly over the hole, ensuring the vent sits flat on the roof. Fasten vent 4-inches o.c.and 1-inch from outside edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring %-inch penetration through wood deck (Minimum 18 nails per vent). Install baffle in '%-inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement. Allowable Roof Coverings: Asphalt shingles VentSure'Rigid Roll 5/8"x 11-1/4"x 20'attic ridge vent composed of high density polypropylene with a Ridge Vent: spun-bond polypropylene fabric. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12-inches from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring%-inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 12 ga. ring shank roofing nails(shall comply with FBC Section 1506.5) or as directed by the shingle manufacturer's installation instructions, ensuring%-inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles OCR14003.2 FL10758-R6 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. OWENS CORNING ROOFING AND ASPHALT LLC CREEK VentSure®Roof Ventilation TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. 3) The roof deck and deck attachment shall be designed by others in accordance with the 2014 FBC. 4) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. 5) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 7) Installation of the roof assembly is outside the scope of this evaluation. 8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. rrrrr��� p �,� 2015.02.2 tip'•• Ile No 74021 "� 3 14:48:59 .- x` -05'00' � 3 STATE OF .'4/� 00 % r-*-P,.' �: Zachary R. Priest, P.E. R •t �1� Florida Registration No.74021 S/pNA�E���` Organization No.ANE9641 �rrrrrr n � CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14003.2 FL10758-R6 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 6/30/015 Florida Building Code Online Iness ' i E Regulation i:yCa vfp3ht n ie SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff 8CIS Site Map Links Search Busines Professi I t. Product Approval ai USSR:Public User Regulation l�II� Prodlict Approval Menu>Product or Application Search>Application List>Application Detail �iiaiYWaYY!!! FL# FL10674-R10 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ,' Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Niernmen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W.Knezevich, PE ✓ Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R10 COI 2015 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code https://fforidabuilding.org/pr/Pr_app dU,aspx?param=wGE\/XQwtDgtBNbEY5V%2boQTa/o2b6w7ahReglCQ8ucR6!xEAoiMeKNJKxMw°/a3d%3d 1/2 6/3012015 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 04/22/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 summaq of Products FL# Model,Number or Name Description _ 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab, 5-tab, laminated, starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R10 II 2015 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R1O.Ddf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE- 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FI1,0674 R10 AE 2015 04 FINAL ER OC ASPHALT SHINGLES FL10674-R10.odf Created by Independent Third Party: Yes Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an WEED employer.Soovriaht 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: 65® *LMck SCNCt� https:/tfloridabuildirig.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEAoiMeKNJKxMw%3d%3d 2/2 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization 1/9503 '� 353 CHRISTIAN STREET, UNIT#13 TRINITY 1 ERD OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R5 One Owens Corning Parkway FL10674-R30 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 5: 04/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: CF Robert ib Robert J.M.Nieminen,P.E. l�3 �'``,+ The facsimile seal appearing was authorized by Robert Nieminen, ✓ s+ P.E.on 04/22/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration Designer Color Collection, TruDefinition Oakridge,Oakridge and WeatherGuard*HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge- Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vaud=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 2 of 6 TRINITY ERD 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: ➢ Berkshire*shingles require minimum five(5)nails per shingle. ➢ WeatherGuard•HP shingles require minimum six(6)nails per shingle. ➢ Devonshire'"shingles require minimum six(6)nails per shingle. ➢ Starter Strip Plus requires minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Classics&Supreme: Normal Mansard or Area para Normal Mansard or Area para Wind Areas High Wind dosvanes y Wind Areas High Wind desvanes y Area para vientos normares Areas vientos fuertes Area para vientos norma/es Areas vientos fuertes "�t• (A1 iri �� �" z"1z• t" izFtt � T S`Exposure 5 5/0"Exposure Expos icidn ExposicM 6.2.6 Minimum Nailing—Berkshires: Sealant strip Sealam strip La Nra de s4aior is gra da soitabr fir— �rr•�—� a e—t a+-----+a e�—s a�---►e e t—►a�--r e 8 Yz" 9 Vt. 9 V, 8 Yf } WISIVIP8 t9" 8 VP8 Yf Asphalt roofing cement Cemento de Who da astatto Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 3 of 6 ..• � TRINITY'ERC? 6.2.7 Minimum Nailing–Devonshire'"': —� Nails r -.-I......... Nails Ten 1"Spots of Asphalt Roof Cement 6.2.8 Minimum Nailing—Duration®,TruDefinition•Duration, Duration® Premium Cool&TruDefinition"Duration"Designer Color Collection: kbwrd and Steep slope 4 Nail Pattern 6 Nail faun between sunxara Esquama do 4 davos Pattern ana andtop or eat DIA. Esquema Umvda ape d~ Surepap®fasting area width ds 6 davosagwxxpda enaro el Area dedarosSuraNail� • • • aeeswewrarapek zpedar stl rsark. 1, 1, so Rao \ SireNai� fasteorq pdmn99 am w' � anawiUn rl^ 17 Awde 1" \ — \ Stu ab SureNaro 1T 1T 1 Sums I� - - Eva"Exposure Nails 6%"Exposure P4 pulg.de exposition davos 6 b ping.de exposkion 5W Exposure Nails W Exposure 51.4pdg.doerposkidn Claws 54pulg.doexposicfon 6.2.9 Minimum Nailing–TruDefinition"Oakridge•,Oakridge*: 4 Nail Pattern 6 Nail Pattom Esquarna con 4 clavos Esquama con 6 clavos 1" 1. r r I<- 1r �_ tr->I t— 12- —� IE— iz. 5 5/9"Exposure Naps 5 5/8"Exposure Naps Erposiddnde66/8pulg• Claves Exposicidnda66/6puig. 66/8•'Exp�n Claves 56f8 Exposure Exposicdn de 6 6/8 pu(g. Exposicida de 6 6/8 pu1g. 6.2.10 Minimum Nailing–WeatherGuard•HP: �. single IN&View View bad Faaftn rTh TOT" ::f' atw�s Nd Lie CJokm M k Ifar do 1�rJia Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R5 Certificate of Authorization 119503 FL10674-R10 Revision 5:04/22/2015 Page 4 of 6 TRINITY:ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire* Hip and Ridge Shingles, High Ridge, Hip& Ridge with Sealant, WeatherGuard*HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4)nails per shingle. Installation of DuraRldge­Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-seating for wind warranties, 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or R90S.2.5. Staples are not permitted. 63.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 9 PIrvaliftwid Fig.2 Medici. Tap'Am_T Nags Nails Top Lan*. %led piece A % 2 _j 6.3.4 Minimum Nailing—Hip&Ridge with Sealant: tem Fig. 2-Nigh W Fastwing Pattem (4 Nails) 'rim Shingle 3nd Discard Excess 2" —SI EMnt t rf P 12" ' Fastening 511,Ris 6:"Exposurme Distance I 12 6.3.5 Minimum Nailing—WeatherGuardO HP Hip and Ridge: Fig.A Fig.C Hip&Ridge Shingle Fastening P,=Irg WMd TopVlaw Will Nails maim �V' A Exposuro P, EXPOSUM 12" Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate of Authorization 119503 FL10674-RI0 Revision 5:04/22/2015 Page 5 of 6 � r TRINITY ERD 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind DirectionFastening Sealant Stripa Pattern �{ 8'Exposure Pattern it' � Seeient Fagan 71h' 71 6"Exposure Cover E=d Fastens with Roof CSM t2' 6.3.7 Minimum Nailing—DuraRidge"Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Pnreiing YAM Dir«den Top View r—Dinttion daninante dv rent Vile,en plan Dineddndel vienta pullcl"uunce I" Vista tuperwr I•H t T 0. Maim _,•_y, +' s Oratw Gorninp StteNal• • et� A i i t I I I A I i i zi$ 8 I ............. A 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 6 of 6