HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
�� ,� w��•� Iff
i ■
Florida DFpatt0lfiliof SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff 1 BCIS Site Map Links Search
Busines
Professi I SER PubuApproval
Regulation
Product Approval Menu>Product or Application Search>Application List>Application Detail
I FL# FL16305-R4
Application Type Revision
Code Version 2014
Application Status Approved
Comments
i
Archived ❑
Product Manufacturer Atlas Roofing Corporation
Address/Phone/Email 2000 RiverEdge Parkway
Suite 800
Atlanta,GA 30328
(770)946-4571
mcollins@atlasroofing.com
Authorized Signature Meldrin Collins
mcollins@atlasroofing.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
® Validation Checklist-Hardcopy Received
Certificate of Independence FL16305 R4 COI ATL13002.4 2014 FBC Product Evaluation
Shingles.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 3161 2009
ASTM D 3462 2009
ASTM D 7158 2008
TAS 100 1995
TAS 107 1995
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquJBMj gU 1 j 3N 1... 7/7/2016
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 06/28/2015
Date Validated 06/29/2015
Date Pending FBC Approval 07/05/2015
Date Approved 08/19/2015
Summary of Products
FL# Model,Number or Name Description
16305.1 Atlas Shingles Fiberglass reinforced laminated asphalt shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16305 R4 II ATL13002.4 2014 FBC Product Evaluation
Approved for use outside HVHZ:Yes Shingles.pdf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use Evaluation Reports
FL16305 R4 AE ATL13002.4 2014 FBC Product Evaluation
Shingles.pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click hgce_.
Product Approval Accepts:
Credit Card
Safe
http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDquJBMjgU1j3N1... 7/7/2016
I
s�
Certificate of Authorization No.29824
CREEK17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 5TH EDITION(2014)
Manufacturer: ATLAS ROOFING CORPORATION Issued June 29, 2015
2000 Riveredge Parkway, Suite 800
Atlanta, GA 30328
(770)612-6267
Manufacturing Plants: Hampton, GA
Meridian, MS
Dangerfield,TX
Ardmore, OK
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties,Wind Resistance,Wind Driven Rain
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST5878) ATL-079-02-01 ASTM D 3161 2009
TAS 107 1995
PRI Construction Materials Technologies(TST5878) ATL-083-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) ATL-086-02-01 Rev 1 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATL-104-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATL-106-02-01 ASTM D 3161 2009
TAS 107 1995
PRI Construction Materials Technologies(TST5878) ATL-106-02-01 Rev 1 ASTM D 3161 2009
TAS 107 1995
PRI Construction Materials Technologies(TST5878) ATLA 07-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) ATL-107-02-01.1 TAS 100 1995
PRI Construction Materials Technologies(TST5878) ATLA 09-02-01 ASTM D 7158 2008d
PRI Construction Materials Technologies(TST5878) ATLA 16-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATLA 18-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATLA 19-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) ATLA 23-02-01 ASTM D 7158 2008d
PRI Construction Materials Technologies(TST5878) ATLA 25-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) ATL-127-02-01 Rev 1 ASTM D 7158 2008d
PRI Construction Materials Technologies(TST5878) ATL-132-02-01 ASTM D 3161 2009
i TAS 107 1995
PRI Construction Materials Technologies(TST5878) ATLA 33-02-01 ASTM D 3161 2009
TAS 107 1995
PRI Construction Materials Technologies(TST5878) ATL-135-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATLA 36-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATLA 37-02-01 Rev 1 ASTM D 7158 2008d
PRI Construction Materials Technologies(TST5878) ATL-138-02-01 Rev 1 ASTM D 7158 2008d
PRI Construction Materials Technologies(TST5878) ATL-143-02-01 ASTM D 3161 2009
TAS 107 1995
PRI Construction Materials Technologies(TST5878) ATL-144-02-01 ASTM D 3161 2009
TAS 107 1995
PRI Construction Materials Technologies(TST5878) ATL-151-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATL-162-02-01 TAS 100 1995
PRI'Construction Materials Technologies(TST5878) ATL-167-02-01 ASTM D 3161 2009
PRI'Construction Materials Technologies(TST5878) ATLA 68-02-01 ASTM D 3161 2009
TAS 107 1995
PRI'Construction Materials Technologies(TST5878) ATL-169-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATL-170-02-01 ASTM D 3462 2009
ATI-13002.4 FL 16305-R4 Page 1 of 9
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
1
ATLAS ROOFING CORPORATION
CREEKAsphalt Shingles
TECHNICAL SERVICES,LLC
PRI Construction Materials Technologies(TST5878) ATLA 71-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATL-172-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATLA 74-02-01 ASTM D 3462 2009
PRI Construction Materials Technologies(TST5878) ATL-179-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) ATL-184-02-01 ASTM D 3161 2009
TAS 107 1995
PRI Construction Materials Technologies(TST5878) ATL-185-02-01 ASTM D 7158 2008d
PRI Construction Materials Technologies(TST5878) ATL-186-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) ATLA 87-02-01 ASTM D 3462 2009
PRODUCT DESCRIPTION
GlassMaster@30 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed,
(Ardmore&Hampton) thermally-activated,self-sealing sealant stripe that complies with ASTM D 3462.
Tough-Master®20 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed,
(Ardmore&Hampton) thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462.
Pro-Cut®Hip&Ridge ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle with a
(Ardmore&Hampton) dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D
3462.
Pro-Cut®Starter Strip ASTM D 3161, Class F fiberglass reinforced,starter asphalt shingle with a dashed,
(Hampton) thermally-activated,self-sealing sealant stripe that complies with ASTM D 3462.
ProLAMTm Architectural ASTM D 3161, Class F&ASTM D 7158, Class H fiberglass reinforced, laminated
(Hampton&Meridian) architectural asphalt shingle with a dashed,thermally-activated, self-sealing sealant
stripe that complies with ASTM D 3462.
Pinnacle@ Pristine, ASTM D 3161, Class F&ASTM D 7158, Class H fiberglass reinforced, laminated
Pinnacle@ Pristine architectural asphalt shingle with two, dashed,thermally-activated,self-sealing sealant
Lifetime w/Scotchgard stripes that complies with ASTM D 3462.
(Darigerfield,Hampton&
Meridian)
StormMaster@ Shake ASTM D 3161, Class F&ASTM D 7158, Class H fiberglass reinforced, laminated
(Dangerfield) architectural modified asphalt shingle with two, dashed,thermally-activated,self-sealing
sealant stripe that complies with ASTM D 3462.:
StormMaster@ Slate ASTM D 3161, Class F&.ASTM D 7158, Class H fiberglass reinforced, laminated
(Ardmore) architectural modified asphalt shingle with two,dashed,thermally-activated, self-sealing
sealant stripe that complies with ASTM D 3462.
I
I
ATI-13002.4 FL 16305-R4 Page 2 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.
ATLAS ROOFING CORPORATION
CREEKAsphalt Shingles
TECHNICAL,SERVICES,LLC
INSTALLATION
GlassMaster@ 30& Basic Wind Speed(Vint): Max. 194 mph
Tough-Master@ 20 Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Contact
the Atlas Roofing Corporation when installing at slope
greater than 21:12.
Installation(HVHZ): Installed with 5-inch exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using T Nail Pattern" detailed
below.
Installation (Non-HVHZ)-. Installed with 5-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
36' -
j Nails
12" ■ a . . A
Y v
Figure 1. GlassMaster@ 30&Tough-Master@ 20
4 Nail Pattern (Non-HVHZ only)
36" -1
I- "1
Nails
J-
12"
■
5518"
Figure 2. GlassMaster@ 30 8Tough-Master@ 20
6 Nail Pattern
I
ATL13002.4 FL 16305-R4 Page 3 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
GDEEK ATLAS ROOFING CORPORATION
j� Asphalt Shingles
TECHNICAL SERVICES,LLC
ProLAMTm Architectural Basic Wind Speed(Vw,): Max. 194 mph
Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Contact
the Atlas Roofing Corporation when installing at slope
greater than 21:12.
Installation(HVHZ): Installed with 6 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 6 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
39 M"
Min.12 go gaba ked roofing nal
wiM min.3B'head
1" 12112° 1"
TVP
0 =1 � 14"
6' 61114"
I
Figure 3. ProLAMTm Architectural Shingle
I
4 Nail Pattern (non-HVHZ only)
39 319-
Mln.12ge.plar f. 6.9 shank rooing nal
wlh mfn.W head
,• 7 1(C
T1'P 1.
Figure 4. Pro-LAMTm Architectural Shingle
6 Nail Pattern
ATL13002.4 FL 16305-R4 Page 4 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
G ATLAS ROOFING CORPORATION
Asphalt Shingles
TECHNICAL,SERVICES,LLC
Pinnacle®Pristine& Basic Wind Speed(Vwt): Max. 194 mph
StormMaster®Shake Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Contact
the Atlas Roofing Corporation when installing at slope
greater than 21:12.
Installation(HVHZ): Installed with 6 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 6 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
39 316'
Nen.12 ga.gah ardzed roaMg nae
1111"In.3R•head
r 12112•� r
TYP
C�D0 0 0 0 0 =1 F--1 0 Ll 13•
6• 6 7/e'
Figure 5. Pinnacle®Pristine and StormMaster®Shake
4 Nail Pattern (Non-HVHZ only)
3938'
I
MM,12 ga.g3Mdntrea Ong shank nad
wdh In,39'hell
/1• 717 t'
0 0 Oo0 O O Oa CD-CD O 0 0 0 C� O O O Oo 14.
O O O O O O O O O O O O O O �O C3 O O O O
6, 6 716'
I L
Figure 6. Pinnacle®Pristine and StormMaster®Shake
6 Nail Pattern
ATI-13002.4 FL 16305-R4 Page 5 of 9
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK ATLAS ROOFING CORPORATION
Asphalt Shingles
TECHNICAL SERVICES,LLC
StormMaster@ Slate Basic Wind Speed(V„ic): Max. 194 mph
Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Contact
the Atlas Roofing Corporation when installing at slope
greater than 21:12.
Installation(HVHZ): Installed with 8.5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 8.5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
9"
1 J
Figure 7.StormMaster@)Slate
4 Nail Pattern
9"
Figure 8. StormMaster@ Slate
6 Nail Pattern
ATI-13002.4 FL 16305-R4 Page 6 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
ATLAS ROOFING CORPORATION
CREEKAsphalt Shingles
TECHNICAL SERVICES,LLC
Pro-Cut®Starter Strip Basic Wind Speed(Vwt): Max. 194 mph
Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Contact
the Atlas Roofing Corporation when installing at slope
greater than 21:12.
Installation(HVHZ): Installed in accordance with RAS 115 and manufacturer's
published installation instructions. Shingles shall be
attached as shown below.
Installation (Non-HVHZ): Installed in accordance with FBC requirements and
manufacturer's published installation instructions. Shingles
shall be attached as shown below.
>z-
H pron
12 ga.1-W-,Ing shank nail
o c
i yr-3-
Figure 9. Pro-Cut®Starter Strip
ATI-13002.4 FL 16305-R4 Page 7 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Cp ATLAS ROOFING CORPORATION
IZ K Asphalt Shingles
TECHNICAL SERVICES,LLC
Pro-Cut®Hip&Ridge Basic Wind Speed(V,wt): Max. 194 mph
Basic Wind Speed`V asd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements.
Installation(HVHZ and Installed with 5-5/8 inch exposure in accordance with RAS
non-HVHZ): 115 (HVHZ only) and manufacturer's published installation
instructions. The direction of the exposed end shall be
away from the prevailing wind.
I 12" 1
12 ga.1-1/2"ring
I
shank nail
j -- - - _— _^— 12„
6"
i
i
Figure 10. Pro-Cut®Hip&Ridge
ATL13002.4 FL 16305-R4 Page 8 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
DEEK ATLAS ROOFING CORPORATION
j'j Asphalt Shingles
TECHNICAL SERVICES,LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 33-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 5v'Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer.
%0. . R.•%Z 2015.06.2
No 74021 �,.
9 12:55:48
�cc_ :_ w _04'00'
:�•• STATE OF .'4U
0 P•:��;
I �`•••4 O R 1�.• �`� Zachary R. Priest, P.E.
%`, Florida
Registration
No. No.74021 21
Organization
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
i
END OF REPORT
ATI-13002.4 FL 16305-R4 Page 9 of 9
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.