Loading...
HomeMy WebLinkAboutEngineering i=- •ti PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone(772) 785 -9888 Email pwelchinc@aol.com June 7, 2016 Re: Church Re-Roof 10725 S. Ocean Drive Unit 497 Jensen Beach,FL 34957 SCOPE OF WORK: Remove existing roofing and install new 5-V Crimp Metal Roof(Gulf Coast Supply& Manufacturing FL# 11651.13) at above referenced residence address over new underlayment and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT=9'-0" A=3' MEAN ROOF HIEGHT=<20' ROOF ANGLE=3:12 SHAPE=PITCHED GABLE IMPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=D ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (ust): ZONE 1 (Field)=-44.7 ZONE 2 (Perimeter/Ridge)_-75.5 ZONE 3 (Corners)_-110.8 Paul Welch Inc. -Paul We1ch.P.E. Reg.No. 29945 -= - July 7, 2016 10725 S.Ocean Drive Unit 497 Jensen Beach,FL 34957 1 of 3 ATTACHMENT REOUMEMENTS: Metal roofing to be attached with#9- 15 x 1 %Z"long(minimum %4"penetration through plywood sheathing)Woodgrip screws with weather sealing washers spacing as follows: ALL FASTENERS IN THE FLAT OF THE PANEL ZONE 1 (Field): Fasteners-adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 2 (Perimeter/Ridge): Fasteners adjacent to ribs one side(Type 1 per product approval) at 16" O.C. ZONE 3 (Corners): Fasteners adjacent to rilis:both side(Type 2 per product approval) at 16" O.C. Zones 1 &2 Design uplift Pressure: -94.25 psf Zone 3 Design uplift Pressure: - 131.0 psf Zones 1 &2: , 94.25>75.5>44.7 Therefore O.K. Zone 3: 131.0> 110.8 Therefore O.K. NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. UNDERLAYMENT : Underlayment shall be Polyglass USA, Inc. FL#5259.1 "Polystick TU Plus". Polystick TU Plus shall be installed in compliance with the codified requirements for ASTM D 1970 underlayment in FBC Section 1507. All seal-lap seams must be firmly rolled with a minimum 281b.hand roller to ensure full contact and adhesion. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum) with 8D ring-shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL# 11651.13), (FL#5259.1), manufacturer's specifications, and the Florida Building Code 2014. Paul-Welch Inc. Paul Welch P.E. Reg.No. 29945 July 7,2016 10725S.Ocean Drive Unit 497 Jensen Beach,FL 34957 ✓ 2 of 3 2 Z 3 � i �, � ��• i It� l l f (' ;"�j" 1 ; r. t � I f SII ! 1 i'il �� '� ' �, '• ! SII ;i ! I Ili ' • ; ; � ! � (ill � �� NoY 1�I`GU1b!'�7cl� 1 pj lu u ) ll JI 2 Z ROOF ZONE PLAN A=3' 70NE DFSIGNA770N(TYPICAL) NOTE: CONTINUOUS APPROVED LAP SEALANT MUST_ BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. _ Paul.Welch Inc. Paul Welch P.E. Reg. No. 29945 July 7;2016 10725 S.Ocean Drive Unit 497 Jensen Beach,FL 34957 _/ 3 of 3