Windows & Sliding Glass Door Replacement Certification:
July 09,.2416
Bill Laprade
Glass Professionals
Stuart,Florida
Cell: 772-475-3459
Email: glassprofessionals@gmail.com
Project: (1)Picture Window Replacement:
Chwalone Residence,Treasure Cove Danes,4100 N AlA Apt 132 Fort Pierce,FL 34949 '
Dear Mr. Laprade:
Please know I personally completed the wind load analysis for the picture window,NOA's, 15-0512.15 by CGI,
Impact rated aluminum.
The glass Type 2,with%4"diameter tapcons,6"from the corners& 17"o.c.maximum with minimum 1.5"
embedment in to concrete-of filled CMU.
Using the ASCE740,,The following parameters were used:
Picture Windows height is less than 12 feet;
Exposure D;Wind speed 170 mph;Enclosed Structure,wind zones 4 and 5;
When taking into account the external and internal pressure coefficients and adjustments per the ASCE7-10,the
resulting and governing applied wind pressure comes to+49.3 psf/-54.1 psf for the governing Zone S.
With the tapcon type,spacing,edge distances and embedment and window installation completed per the
respective NOA,the allowable.loads of+66.6psf for the window exceeds the applied loads in this application,
and is acceptable to my office.'
Itis recommended that all fasteners be of high quality stainless steel.